Panther Fan Coil Unit

Similar documents
INTRODUCTION Flexibility Is The Key Simple Access For Maintenance

Efficient Cooling and Heating. Flexibility Is The Key

Panther Fan Coil Units

Installation, Operation and Maintenance Instructions Document Ref:

Installation, Operation and Maintenance Instructions Document Ref:

Installation, Operation & Maintenance Instructions Document Ref:

WIRING DIAGRAMS AND OTHER RELAVENT LITERATURE WITH THE END USER. access panel Fan speed and on/off switches. Discharge spigot. Fan/motor.

Ocelot Fan Coil Units

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Actionair Hydropac Waterside Control Fan Coil Units For Horizontal and Vertical Applications

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

FAN COIL UNITS IMPORTANT NOTE ABOUT EC FAN SPEED CONTROL

Installation, Operation & Maintenance Instructions Document Ref:

Aegean Range. A new range of fan coils for heating and cooling commercial applications

Series CM. Cased fan convector Sill-Line 600mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW C heating medium

S E R I E S B M C O M F O R T, A V A N T - G A R D E & L S T F A N C O N V E C T O R S

SERIES BM. Concealed Fan Convector

Caice Attenuator Selector - Specifier Edition

TOSHIBA AIR CONDITIONING

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

Caice Attenuator Selector - Specifier Edition

BELGRAVIA Classic (Vertical Units) - Technical Data Sheet

TopVent Design Handbook

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Technical Data Ducted Three Phase Split System Air Conditioner

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

EC Motor Fan Coil Units. IMD-Y Series l/s

EHH SERIES DRAW THROUGH FAN COILS CFM

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

FAN COIL UNITS. The optimal solution for limited space

Blower-YEFB-020-3R-1maxVel

Caice Attenuator Selector - Specifier Edition

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Condensing Units CUS 15-60

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

The new Xcell EC High Efficiency Range Fresh air pure and simple

QTS SELECTION TECHNICAL BOOKLET

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Lo-Carbon Sentinel Kinetic Horizontal

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

FCC Fan-Coil Units High-Performance, Vertical

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

KOMFORT EC DB Suspended heat recovery air handling units

SIMPLICITY FULL MODULARITY?

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

Metropolitan high output natural and powered trench heaters

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

Lo-Carbon Sentinel Kinetic Range Overview

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

(UK) Date : February 2016 NOTE: PLEASE LEAVE COPIES OF THESE INSTRUCTIONS AND ANY DRAWINGS WITH THE END USER.

LZT High efficiency air to water heat pumps with E.V.I. compressors

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

The Sentinel Kinetic Horizontal Range

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

ROOFTOP PACKAGED AIR CONDITIONERS

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

WXC R134a. Nominal Cooling Capacity from 224 to 692kW

Neosys Product catalogue

Units for suspended ceilings

Lo-Carbon Sentinel Kinetic Range Overview

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

LZA High efficiency air to water heat pumps with HP compressor

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

High temperature air-to-water heat pumps

Chilled Water DOAS Fan Powered Terminal Units

INDUSTRIAL AIR CURTAIN. IndAC 2

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Direct Fired Heater Model AD Specification

H Y D R O C O U R S E T R E N C H H E A T I N G

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

The ultimate fresh air solution.

TOSHIBA AIR CONDITIONING

BRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING

OPUSXBOX - SMALL COMMERCIAL HEAT RECOVERY SYSTEM LOW DEPTH, HEAT RECOVERY UNIT WITH MULTIPLE SPIGOTS AND ECOSMART CONTROLS.

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

SIMPLICITY OR FULL MODULARITY?

Specification Data. General:

Sentinel Demand Energy Recovery Ventilation

Transcription:

Panther Fan Coil Unit Energy Efficient EC Motors 280mm Deep Chassis Horizontal Fan Coil Unit

INTRODUCTION The Panther, manufactured by Dunham-Bush is an adaptable, easy to use fan coil unit, that performs quietly and powerfully, with inherent quality. Panther fan coil units are built to no-compromise engineering standards using only the most modern and reliable components available. Combined with the very latest design and manufacturing technology, the Panther provides the ideal solution to achieve exact thermal and noise criteria. Careful consideration has been given to safe site handling, fast / simple installation and ease of access for maintenance. Designed to offer maximum site flexibility, the Panther is one of the most versatile and user-friendly products available in today s market. Flexibility Is The Key The Panther uses a non-handed, dual-purpose coil block covered by a stainless steel V formed condensate pan, terminating with a central drain point at the lowest end of the tray. This universal design is used on both RH and LH configurations and allows the complete coil and condensate pan assembly to be site reversible without the need for any additional parts. The discharge plenum is supplied with a combination of spigots and blanking plates that can be interchanged on site. The added facility to re-locate the controls box from one side of the unit to the other gives the Panther the flexibility to accommodate site layout changes and client fit-outs. If required it can even be used for underfloor applications. Simple Access For Maintenance Removing large panels secured by 10-20 screws and then getting them through a 600mm x 600mm ceiling grid, all whilst stood on a stepladder, has made life difficult for the maintenance engineer in the past. Special consideration has been given to overcoming these problems and the resultant Panther now brings a breath of fresh air to maintenance tasks. The main unit access panel is secured by quarter turn quick release fasteners and gives access for inspecting the fan motor assemblies. Each fan motor is mounted separately onto the main bulkhead plate with an in-line plug and socket to facilitate easy removal. Filters are simple to remove for cleaning, they withdraw from either the rear or side of the unit without the use of tools or need to remove panels. On model sizes 4-7 both the filters and fan access panels are split into two smaller sections for easier removal and handling. Electrical and controls work can be easily carried out via two hinged covers giving access to all components. The stainless steel condensate pan can also be easily removed for cleaning via its own separate access panel. Energy Efficient EC Fan Motors The Panther incorporates high efficiency EC (electronically commutated) fan motors. Fan speed is controlled via an external 2-10VDC signal which can be provided by a manual, pre wired or remotely supplied speed control potentiometer. Alternatively, the signal can be supplied directly from the BMS (Building Management System). High Quality Fan Motor Assemblies The fan motor assemblies are individually mounted on to a floating bulkhead plate, isolating them from the rest of the unit chassis, reducing resonance and casing breakout noise. Use of the highest quality components available is never more important than in the case of the fan motor assemblies to ensure that quiet and powerful operation is consistently achieved year after year. Adaptable Controls Box Panther fan coil units are supplied with a wellventilated controls box supplied with a one metre flying lead for connection to an adjacent fused spur. The box has been designed to accommodate most temperature controllers and associated electrical components. The complete controls box can be disconnected from the unit for any major electrical / controls refurbishment, this design also enables the controls box to be retrofitted after the unit has been installed. Long Life Stainless Steel Condensate Pan Panther fan coil units incorporate stainless steel condensate pans as standard. By using stainless steel, cleaning is made easier whilst the resistance to corrosion is increased, vastly improving the longevity of the pan. The fully welded V formed pan creates a positive seal against the coil preventing any air bypass. The pan is mounted to provide a positive fall in two directions to the central outlet at the lowest end of the pan. The 22mm O.D. stainless steel outlet is finished flush with the bottom of the pan ensuring that condensate drains completely.

FEATURES Electrical control & connections box Repositionable spigots (Ø 150mm to Ø 250mm) Repositionable spigot blanking plates Condensate drain connection (Ø 22mm plain) Removable fan motor & plenum access panels Coil connections (heating & cooling) G2 polyester inlet filter Removable condensate pan & coil access

DIMENSIONS 90 70 437 M10 Fixing Centres 437 M6 Fixing Centres 280 140 Direction of Air Flow 815 22mm Drain Connection LH Unit shown, RH opposite Unit handings are viewed looking against the direction of air flow, in plan view Dimension "A" 203.0 178.0 Dimension "B" Fixing Centres Control Box Plenum Access Fan Access Drip Tray Access Filter Access Unit view from below Model 1 2 3 4 5 6 7 Dimension A (mm) 675 1075 1075 1475 1475 1875 1875 Dimension B (mm) 641 1041 1041 1441 1441 1841 1841 Dry weight (kg) 37 51 56 70 74 92 96 4

Models Panther 6 & 7 View from below F E D C B A 350 350 413 350 413 E D C B A Models Panther 4 & 5 View from below 350 388 388 350 D C B A Models Panther 2 & 3 View from below 350 363 363 C B A Model Panther 1 View from below 338 338 Standard discharge options available for all models: Octangonal plenum circular spigots (above) Rectangular plenum circular spigots Rectangular plenum rectangular spigot Standard Spigot Sizes (mm) Ø 250 Ø 225 Ø 200 Ø 150 Direction of Air Flow Direction of Air Flow 76 40 12 133 HTG CLG R F HTG CLG R F 133 40 76 12 166 166 199 199 LH Pipework detail Ø 22mm Drain Connection RH Pipework detail 5

CONTROLS & ACCESSORIES Standard Thermal Controls Panther fan coil units can be supplied with a number of standard factory fitted control packages. These packages typically consist of a setpoint controller with return air sensor, 2 or 4 port valves and actuators. Speed control dial and switches can be mounted to the control box or supplied loose for remote installation. Other control options available upon request. Optional fitted condensate pump Ancillary Components A range of optional ancillary components for the Panther fan coil unit are available, including: Condensate pumps Fan monitoring devices Control relays Electric heating elements Acoustic attenuation Inlet plenums Pressure independant control valves Extended condensate pans Standard 4 port valves and actuators For any special requirements, please contact the Dunham-Bush sales department for further information and availability. Dunham-Bush Zone Flow Fully Communicating Control The Zone Flow system by Dunham-Bush includes a fully functional communicating controller, enabling FCUs to communicate with external networks. The system allows individual control of FCUs via a router or gateway, communicating to any network such as BACnet, Echelon, Modbus networks as well as BMS networks. Alterations to the control strategy can be made using a web-serving graphical user interface, allowing the user to edit control software and algorithms. The controller is fitted with an enhanced range of analogue, digital and universal inputs/outputs as well as sensors for monitoring FCU status. Panther control box with fitted speed potentiometer Free Issued Controls A service to fit non-standard free issued controls is available. The Panther control box has been designed to accommodate most temperature controllers and associated electrical components. Please note: Factory fitting of free issued controls is subject to component compatibility and suitability. Dunham-Bush Zone-Flow control software 6

SPECIFICATION The Panther Series Fan Coil Units shall be manufactured by Dunham-Bush Limited, Downley Road, Havant, Hampshire, PO9 2JD. Units shall be selected to achieve the required performance data whilst operating against the specified design parameters. Panther units shall be of a draw through design and comprise a washable air filter, multi-block coil with separate connections for cooling and heating, stainless steel condensate pan, low noise external rotor EC fan motors, integral multi-outlet discharge plenum and an electrical / controls enclosure. Unit Chassis - Chassis shall be of a rivetted construction manufactured from a minimum thickness of 1.2mm galvanised steel. Stiffeners and strengthening folds shall be used to form a solid robust structure. Recessed, reinforced mounting slots able to accept M6, M8 or M10 drop rods or mounting bolts are provided for installation whilst the panel design and use of dutch folds produce a flush external finish with no sharp edges. Fan/Motor assemblies shall be mounted on a 1.6mm floating bulkhead plate, isolated from the rest of the unit to reduce noise resonation through the unit casing. Panels shall be designed to allow separate unhindered access to the serviceable items, namely filters, condensate pan, coil, fans / motors and controls. Discharge (Supply Air) Plenums - Mitred corner or rectangular, integral acoustically lined discharge plenum shall form part of the unit chassis with multi-outlet spigots with various size options available to match most ductwork configurations. Use of interchangeable circular spigots and blanking plates, secured to the plenum by screws allow outlet positions to be easily moved or extra spigots to be added in the event of a site layout changes or client fit-out. Access - Access for inspection and service to the fans/motors shall be via an insulated panel secured with 1/4 turn captive quick release fasteners. On model sizes 4-7 this panel is to be split into two sections to allow easy removal by a single engineer through a standard ceiling grid. Access to the condensate pan / coil, filters and discharge plenum are via separate insulated panels by M6 setscrews into nutserts. All access panels form a positive airtight seal against the main unit chassis Insulation - Unit chassis and panel work shall be both thermally and acoustically insulated with 95kg/m 3, CFC & HFC free, Class 'O' open cell expanded foam insulation, having a maximum thermal conductivity of 0.047 W/mK, fully complying with London Borough and CAA flammability and toxicity requirements. The adhesive is a modified acrylic, light and ageing resistant synthetic resin with high temperature tolerance. Air Filters - Filters shall be fully framed, washable, polyester G2 media to BS EN779. Filters shall be easily removable from either the rear or side of the unit without the need to remove any panel work. Coils - Coil shall be multi-block, dual purpose type, divided into two sections to provide both cooling and heating. To be constructed from 3/8 seamless copper tube mechanically expanded into aluminium fins and brazed into copper headers. Aluminium fins shall have die formed collars to maximise contact with the tubes and provide maximum heat transfer. Coils shall be circuited to provide low hydraulic pressure drops under normal operating conditions whilst being designed to prevent air locks, ensuring positive venting and draining via easily slotted hexagonal vent plugs. Coils to terminate with 15mm O.D. copper tails, spaced at 40mm centres to accept most standard 4-port valves. Tails are to terminate within a restraining plate providing adequate support to the control valves and adjoining pipework. Coils shall be tested by dry air under water to 30 bar. Condensate Pan - The condensate pan shall be of a one-piece construction manufactured from 1.2mm 304L stainless steel with fully brazed corners. Pans to be 'V' formed and mounted to provide a positive fall in two directions ensuring the free flow of condensate to the 22mm diameter stainless steel end connection. Pans shall be externally insulated with 3mm closed cell class 'O' thermal insulation. Pans to be enclosed within a galvanised steel carriage providing both protection against damage and easy removal for cleaning. EC Fan Motors - Fan motors shall be high efficiency, low noise, electronically communtated 3-core dc, external rotor type with resilient mounts to minimise noise and vibration. Winding insulation shall be rated to Class B and bearing shall be sealed for life. Units require a 200/277V 50 or 60Hz single phase power supply. Each fan shall be DIDW forward curved and shall be statically and dynamically balanced. Fan Motor Assemblies - Fan motor assemblies shall be mounted separately onto a 'floating' bulkhead to isolate noise resonation from the rest of the unit and facilitate easy removal of an individual fan motor for replacement. Alternatively the complete 'floating' bulkhead can be removed from the unit for major attention. Fan Motor Speed Control - Fan speed control shall be affected by a 2-10VDC control signal to the motor(s). An infinitely adjustable potentiometer fitted within the controls box, or supplied loose for remote mounting, enabling selection of the desired fan speed to be achieved. Alternatively the motors can be controlled directly by a BMS signal, or other source. Controls Box - Each unit shall be provided with a well-ventilated electrical box complete with two hinged lids for ease of access. The control box shall contain a speed control potentiometer (if not supplied loose for remote fitting), harmonic filter, on/off switch (if not supplied loose for remote fitting) and terminal connection block. Each will also contain a mains fuse whilst also providing space to accommodate most available temperature controllers along with any associated relays (if required). The control box shall be provided with a 1 metre flying lead for site connection to an adjacent fused spur outlet. Temperature Controls - Temperature controls shall be provided in accordance with the project specification. Standard temperature controls will comprise of modulating 2 or 4 port valves and actuators, acting in conjunction with a return air sensor wired into an electronic stand alone controller. For special or non standard control packages a service to factory fit free issued control components is also available, further information about this service is available upon request. 7

COOLING DATA Chilled Water Flow/Return Temperature 5.5/11ºC 6/12 C 8/13ºC 10/14ºC Model Fan Speed EC Input Voltage (V) Air Volume (l/s) Sens Total Sens Total Sens Total Sens Total Pan 1 Pan 2 Pan 3 Pan 4 Pan 5 Pan 6 Pan 7 Ultra Low 5.2 85 1.46 1.90 1.38 1.74 1.25 1.46 1.11 1.20 Extra Low 5.7 97 1.62 2.08 1.53 1.90 1.38 1.60 1.24 1.33 Low 6.2 122 1.95 2.46 1.82 2.21 1.66 1.89 1.50 1.60 Medium 7.2 146 2.27 2.82 2.10 2.51 1.92 2.17 1.75 1.87 Ultra Low 5.9 117 2.04 2.67 1.92 2.43 1.74 2.05 1.55 1.68 Extra Low 6.7 2.40 3.10 2.26 2.79 2.05 2.37 1.84 1.98 Low 7.9 168 2.76 3.51 2.56 3.13 2.33 2.68 2.11 2.27 Medium 8.4 181 2.94 3.72 2.72 3.31 2.48 2.84 2.25 2.42 Ultra Low 5.1 147 2.56 3.36 2.40 3.04 2.18 2.57 1.96 2.12 Extra Low 5.8 200 3.36 4.32 3.12 3.86 2.85 3.30 2.57 2.77 Low 6.7 248 4.06 5.16 3.77 4.61 3.45 3.96 3.11 3.34 Medium 7.5 294 4.72 5.96 4.39 5.34 4.02 4.59 3.63 3.89 Ultra Low 5.3 180 3.13 4.10 2.91 3.67 2.66 3.12 2.38 2.58 Extra Low 5.9 230 3.88 5.01 3.59 4.45 3.28 3.80 2.97 3.20 Low 6.8 280 4.61 5.88 4.26 5.22 3.91 4.49 3.54 3.80 Medium 7.8 332 5.34 6.75 4.96 6.03 4.55 5.19 4.11 4.41 Ultra Low 4.7 185 3.33 4.43 3.12 4.00 2.83 3.38 2.52 2.74 Extra Low 5.3 244 4.26 5.58 3.97 5.02 3.62 4.26 3.25 3.52 Low 6.2 319 5.40 6.97 5.04 6.28 4.59 5.34 4.14 4.46 Medium 7.2 394 6.48 8.27 6.09 7.51 5.55 6.40 4.99 5.36 Ultra Low 5.0 230 4.06 5.34 3.77 4.77 3.43 4.05 3.09 3.35 Extra Low 5.6 307 5.23 6.78 4.85 6.05 4.44 5.17 4.00 4.32 Low 6.3 375 6.23 7.98 5.79 7.15 5.30 6.12 4.78 5.14 Medium 7.2 446 7.24 9.18 6.76 8.26 6.18 7.08 5.56 5.97 Ultra Low 5.1 282 5.05 6.69 4.71 6.03 4.29 5.11 3.84 4.18 Extra Low 5.3 324 5.71 7.51 5.34 6.78 4.86 5.75 4.36 4.73 Low 6.1 412 7.04 9.14 6.61 8.29 6.02 7.04 5.40 5.83 Medium 6.8 499 8.27 10.58 7.84 9.74 7.13 8.26 6.35 6.83 Maximum cooling performance data is based on an entering air condition of 23ºC dry bulb and 16ºC wet bulb, airflow rates based on external static pressure drop of 30Pa. Dunham-Bush can offer a selection service for any conditions not stated above. Please contact the Dunham-Bush sales department. 8

HEATING & ELECTRICAL DATA Hot Water Flow/Return Temp. 82/71ºC 60/50ºC 50/40ºC Electrical Data Model Fan Speed EC Input Voltage (V) Air Volume (l/s) Duty Duty Duty SFP (W/l/s) Norminal Max Running Current (A) Ultra Low 5.2 85 2.27 1.30 0.64 0.21 Pan 1 Extra Low 5.7 97 2.47 1.42 0.72 Low 6.2 122 2.88 1.65 0.93 0.22 0.24 0.64 Medium 7.2 146 3.28 1.86 1.15 0.29 Ultra Low 5.9 117 3.48 2.06 1.38 0.23 Pan 2 Extra Low 6.7 3.95 2.33 1.57 Low 7.9 168 4.39 2.59 1.73 0.27 0.33 0.64 Medium 8.4 181 4.61 2.72 1.82 0.37 Ultra Low 5.1 147 4.02 2.37 1.59 0.20 Pan 3 Extra Low 5.8 200 4.94 2.91 1.94 Low 6.7 248 5.73 3.37 2.24 0.22 0.25 1.28 Medium 7.5 294 6.43 3.77 2.51 0.29 Ultra Low 5.3 180 5.05 2.93 1.58 0.20 Pan 4 Extra Low 5.9 230 5.92 3.43 2.09 Low 6.8 280 6.76 3.90 2.54 0.22 0.27 1.28 Medium 7.8 332 7.59 4.37 2.84 0.32 Ultra Low 4.7 185 5.14 2.98 1.63 0.20 Pan 5 Extra Low 5.3 244 6.15 3.56 2.23 Low 6.2 319 7.38 4.26 2.77 0.21 0.25 1.92 Medium 7.2 394 8.53 4.90 3.17 0.30 Ultra Low 5.0 230 6.58 3.87 2.59 0.20 Pan 6 Extra Low 5.6 307 7.94 4.66 3.10 Low 6.3 375 9.10 5.32 3.53 0.21 0.24 1.92 Medium 7.2 446 10.26 5.99 3.97 0.29 Ultra Low 5.1 282 7.50 4.41 2.94 0.21 Pan 7 Extra Low 5.3 324 8.23 4.83 3.21 Low 6.1 412 9.70 5.67 3.76 0.21 0.25 2.56 Medium 6.8 499 11.06 6.45 4.27 0.27 Maximum heating performance data is based on an entering air condition of 20ºC, airflow rates based on external static pressure drop of 30Pa. Dunham-Bush can offer a selection service for any conditions not stated above. Please contact the Dunham-Bush sales department. 9

ACOUSTIC DATA Radiated Sound Power Levels (SWL) db ref.10-12 W Model Pan 1 Pan 2 Pan 3 Pan 4 Pan 5 Pan 6 Pan 7 Discharge Radiated (db) Inlet / Case Radiated (db) Fan Speed Frequency (Hz) Frequency (Hz) 125 250 500 1k 2k 4k 125 250 500 1k 2k 4k Ultra Low 42 45 39 29 11 14 45 44 47 36 30 26 Extra Low 43 46 41 31 12 16 46 46 49 38 32 29 Low 45 48 42 34 14 18 47 47 50 40 34 31 Medium 47 50 45 39 17 23 50 50 51 44 37 35 Ultra Low 44 46 38 29 12 14 48 46 47 38 34 29 Extra Low 45 48 41 32 13 16 49 48 48 40 36 32 Low 47 51 42 38 16 20 52 52 51 44 40 36 Medium 48 51 43 37 17 21 53 52 52 45 41 37 Ultra Low 41 44 39 27 10 12 45 46 47 36 29 24 Extra Low 44 47 43 32 14 15 47 49 50 40 34 30 Low 47 49 44 34 16 19 49 50 51 43 36 33 Medium 48 52 46 36 19 22 51 53 53 45 39 36 Ultra Low 41 43 40 30 13 15 47 44 46 37 31 26 Extra Low 44 46 43 35 17 21 49 47 49 43 37 33 Low 47 48 45 39 21 25 50 49 51 45 39 36 Medium 49 49 47 40 24 28 53 52 53 48 42 39 Ultra Low 43 44 39 30 14 12 44 44 45 35 28 23 Extra Low 45 47 42 34 16 15 47 47 47 38 32 28 Low 48 51 45 38 19 19 51 51 51 42 37 34 Medium 51 54 48 41 23 23 55 54 53 46 41 39 Ultra Low 41 43 39 27 12 13 46 45 45 35 30 24 Extra Low 42 45 41 31 14 16 48 48 47 38 33 28 Low 44 48 43 34 16 20 50 50 50 42 36 33 Medium 47 51 45 35 20 23 53 53 52 45 39 37 Ultra Low 42 45 41 32 16 14 44 45 46 37 31 27 Extra Low 43 46 42 33 17 15 45 46 47 38 32 28 Low 46 49 45 37 19 19 48 50 50 42 36 34 Medium 48 51 47 39 21 22 51 52 52 45 40 37 End Reflection Losses Frequency/Hz 125 250 500 1k 2k 4k 8 4 1 0 0 0 The above Sound Power Levels have been derived using the Real Room test method. All units were tested using two 250mm supply ducts with an extenal static resistance / pressure drop of 30 Pa applied to the low speed setting. To obtain In-Duct sound Power levels, the end reflection losses shown in the above table should be added to the discharge levels. 10

HYDRAULIC DATA Cooling Coil Pressure Drops 60 Pressure Drop (kpa) 55 50 45 40 35 30 25 20 Pan 1 Pan 3 & 4 Pan 4 & 5 Pan 6 & 7 15 10 5 0 0 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 Flow Rate (l/s) Heating Coil Pressure Drops 60 55 Pressure Drop (kpa) 50 45 40 35 30 25 20 Pan 3 & 4 Pan 1 Pan 4 & 5 Pan 6 & 7 Water Content of Model Coil (litres) Clg Htg Panther 1 1.70 0.2 Panther 2 & 3 2.55 0.28 Panther 4 & 5 3.68 0.40 Panther 6 & 7 4.53 0.51 15 10 5 0 0 0.05 0.10 0.15 0.20 0.25 0.30 0.35 Flow Rate (l/s) 11

Manufacturer reserves the right to change any product specification without notice Dunham-Bush Ltd Downley Road Havant Hampshire PO9 2JD Tel. 023 9247 7700 Fax. 023 9245 3601 Email: fancoils@dunham-bush.com www.dunham-bush.co.uk 12 PDS-1000-F-0213-07 Nov 2013