Battery Powered Digital Mass Flow Meters for Gases

Similar documents
Battery Powered Digital Mass Flow Meters for Gases

Battery Powered Digital Mass Flow Meters for Gases

Instruction manual red-y compact series

CATALOGUE Controls/Networks STRACK LIFT AUTOMATION. MULTiBUS -Coupler

Engineering Guideline. pac- Carriers Type Universal

FLAME AMPLIFIER MODULE 3001D

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Gas cylinder scale Model GCS-1

PowerRouter application guideline

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

max C 15 minutes other types on request 3 x 0,25 mm2 or plug M8, other types on request

GMH 285 / GMH 285-BNC

Danfoss gas detection units

SUPREMATouch. Modular Fire & Gas Detection System

3500/61E & 3500/67E Temperature Monitor

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Oxygen (O2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

CTT8 TEMPERATURE MONITOR DEVICE

Temperature Controllers

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

PolyGard 2-channel Gas Controller MGC-03

HOBO U14 Data Logger User Manual

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

SHAKING WATER BATHS ENGLISH

MO n : 12JMC rév A

SUPREMATouch. Modular Fire & Gas Detection System

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

Sensirion Sensor Solutions. Humidity and Temperature Liquid Flow Gas Flow Differential Pressure

Gas Controller Module GC-06

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Danfoss gas detection unit Type GD Heavy Duty

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

Speed and Frequency Seite 1 von 7

FCCP 200: Fume-cupboard indicator and monitor

FLAME AMPLIFIER MODULE 3001

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Two-Channel Gas Controller

ESSEX ENGINEERING CORPORATION

Flostop TS D7E and A8E. Operation Manual

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Multi-Gas-Controller MGC2

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

I/A Series 716C 1/16 DIN Temperature Controller

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

HydroFlex 3-in-1 microplate strip washing. Flexible and reliable microplate strip washing and vacuum filtration in a compact, modular platform

THE CHANGE IN GEAR ENGINEERING

Analog Room Pressure Monitor RPC Series

MCS 4000 Control Panel

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

UDC 700 Universal Digital Controllers and Indicator Specifications

Model OEM-2 INSTRUCTIONS FOR USE

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Process Alarm Module RTA 421

APPLICATION DATA SHEET

U5700 Submersible Liquid Level Pressure Transducer

Danfoss gas detection units

M5200 Industrial Pressure Transducer

Level gauges Series LS Level indicator, switch and transmitter for liquids

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Series Temperature Controller Instruction Sheet

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

More Precision. thicknesssensor // The sensor for precise thickness measurements

U5300 Industrial Pressure Transducer

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

Panel Mounted Fault Annunciator Series

D5100 Industrial Differential Pressure Transducer

K 100 (W) DES. Disinfectant measurement. Applications. Description. Intuitive and simple menu Safety by password function. Disinfection.

Altanium Temperature Controllers

2-wire Passive Intelligent Loop (LED) Display Meter

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

intelligent solutions

Sitron s CF Line of Flow Switch Monitors

Parameterisable compact fault annunciator with permanent display

Thermal mass fl owmeter Precise and dynamic gas measurement with Sensyfl ow

Dew point set DS 400

D5100 Industrial Differential Pressure Transducer

Flopurge TS. Operation Manual

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

EC3-X33 Stand-alone Superheat Controller Technical Data

DATA SHEET CS8100 CS8100_IT_EN_DS049REV02_IS

Touchpoint Pro Flexible Gas Control System

SIARGO MEMS FLOW SENSING PRODUCTS MEMS Mass Flow/Clog Sensors VC Siargo Ltd. ISO 9001 ISO OHSAS 18001

Synova TM product catalog.

Control and Indicating Equipment

MICROSYSTEMS FOR SELECTIVE GAS SENSING. Ulrike Lehmann, MICROSENS. Gas Sensor Microsystems U. Lehmann, A. Grisel, MICROSENS 1

Transcription:

Next Generation red-y compact: AA Battery Powered Touch Interface Micro-USB Port Alarm Option red-y compact 2 series product information Battery Powered Digital Mass Flow Meters for Gases

Independent digital convenience: Thermal Mass Flow Meters for Gases The red-y compact 2 series mass flow meters are characterized by powerful technology, intelligent functions and innovative design. This latest generation offers a new level of ease of use: compact design with battery power and touch display for great flexibility. Touch Interface The touch display offers intuitive navigation. The many variables that make the unit flexible are easily accessible. Automatic display alignment thanks to position sensor Independent Operation The flow meters are powered with a standard AA battery or Micro-USB power supply. Optional 24 Vdc power supply available Modular Extensions The instruments can be extended and retrofitted with different modules: battery module, power module and alarm module High Accuracy & Dynamics The devices offer high accuracy & a wide dynamic range: Accuracy up to ±1% of full scale Turndown ratio up to 1 : 100 (depending on application/measuring range) Totalizer In addition to the actual 4674 flow, the total consumption is displayed. Ideal for gas 4674 consumption measurements Instrument versions red-y compact 2 series 1 Device Multiple Gases One measuring device can be used for up to 3 different gases or gas mixtures Power supply Version Touch Display 1 Auto display alignment (position sensor) Choose between multiple home screens Totalizer Multigas (up to 3) Manual valve Alarm functions Mirco-USB power supply (DIN62684) Battery power 24 Vdc supply Password Protection To avoid unauthorised change of settings, the menu of the new red-y compact can be locked with a password compact meter GCM compact regulator GCR compact switch GCS compact all-in GCA 3-Year Warranty* High-quality components ensure long and trouble-free operation *does not apply to calibration, battery, options and accessories Standard Option 1 backlight not available for battery use; backlighted only with external power supply (Micro-USB or 24 Vdc)

The new red-y compact 2 series Even more stunning features: Wide Choice of Flow Units: Choose between a large number of standardized and normalized flow units of the Imperial, US customary and SI measuring systems (with user adjustable reference conditions). The units are selectable from the integrated menu both for the actual flow and the totalized flow Extended Alarm Functions: The red-y compact 2 series provides 3 configurable alarms. The following triggers are available: Low alarm, high alarm, window alarm and totalizer alarm The alarms can be configured with different parameters: Normally open, normally closed, hysteresis, auto/manual/remote reset, delay and alarm duration Device Information & Notifications Display of complete device information including all configuration settings. Alerts and notifications show up on the home screen Upgrade Device Features New device features will be available and can be updated through the built-in USB interface. Stay informed on latest releases at twitter.com/vogtlinmassflow or www.voegtlin.com VA-Meters vs. Massflow Meters Many applications require a higher accuracy together with pressure and temperature compensation which cannot be realized with conventional variable area flow meters. VA-meters are extremely sensitive to pressure and temperature changes. 1 bar change in pressure can generate an error of 50% in your measurement. Our mass flow meters generate repeatability! The electronic alarm module offers many options over a single VA-meter alarm. Autonomy, precision and comfort for your application Through the application of high-precision MEMS technology (CMOS sensors), the thermal flow meters and controllers from Vögtlin Instruments GmbH set new standards in terms of response characteristics and measuring accuracy, and are characterized by maximum convenience: The devices are very compact, can be installed in any position, and are immediately ready for operation The built-in touch display with an intuitive navigation offers various settings The devices measure real mass flow, independent of changes in pressure and temperature. This provides high accuracy and repeatability to the measuring results In addition to the actual value, the total consumption is displayed. This creates transparency in supply systems The autonomous operation with a standard AA battery makes the compact a high-precision alternative to variable area flow meters High quality: All flow meters are produced and calibrated at our European production center in Germany Our specialists will be happy to advise: +41 61 756 63 00 or www.voegtlin.com

Alarm option red-y compact 2 series The models GCS (red-y compact 2 switch) and GCA (red-y compact 2 all-in) provide 3 configurable alarm relays. The following triggers are available: High alarm, low alarm, window alarm and totalizer alarm. The alarm module can be retrofitted on existing red-y compact 2 meters & regulators. Features: 3 alarm contacts (relays that can switch up to 1 amp, 30 Vdc) 2 optical isolated input channels (to optionally reset an alarm remotely) Every alarm contact separately settable as high, low, window or totalizer alarm Hysteresis, delay and alarm duration time all customer configurable Built-in 8 30 Vdc power supply, polyfuse protected 2 meter fly lead cable included All variables adjustable locally through touch screen Pin assignements Pin Color Assignement 1 Power red PWR+ 2 black PWR- Input 2 3 white IN2 Input 1 4 brown IN1 Input GND 5 green IN.GND 6 yellow OUT3.NO Alarm 3 7 grey OUT3.NC 8 pink OUT3.COM 9 Alarm 2 blue OUT2.A 10 violet OUT2.B 11 Alarm 1 grey-pink OUT1.A 12 red-blue OUT1.B Functions Logic functions High alarm, low alarm, window alarm, totalizer alarm Reset functions Auto, manual, external input 1 / input 2 Power input Voltage supply range 8...30 Vdc (power supply hereafter refered to as the 24 Vdc power supply) Max. current 300 ma Protection input Polyfuse (trip current > 500 ma) and reverse polarity protected Switch ratings switch 1 + 2 (SPST hard contact) / switch 3 (SPDT contact) Maximum voltage 30 Vdc Relais lifetime > 5 million cycles Maximum current Switch 1 + 2 (SPST hard contact): 0.5 A / Switch 3 (SPDT contact): 1 A Inputs 1 + 2 (opto-couplers) Voltage range (polarity sensitive) 5 30 Vdc (@ 5 ma max.) Min. recommended pulse width 100 msec (sample interval 20 msec) Dimensions red-y compact 2 series Length (mm) Length of fitting Type / Body A B C D P GCM G¼" GCR G¼" GCS G¼" GCA G¼" 114 44 25 44 We offer a range of different inlet/outlet fittings. 18.5 26.5* * only valve units (GCR+GCA) GCM G½" GCS G½" 160 54 35 54 GCR G½" GCA G½" 207 54 35 54 C D Micro-USB Interface (DIN 62684) Find more detailed drawings in the red-y compact 2 series manual available on www.voegtlin.com/downloads

Technical data red-y compact 2 series Instrument types compact meter GCM Mass Flow Meter compact switch GCS Mass Flow Meter with Alarm Functions Measuring ranges compact regulator GCR Mass Flow Meter with manual Valve compact all-in GCA Mass Flow Meter with Alarm Functions & Valve compact G½" versions For 1/2" size with manual valve, the valve is flange mounted (full scale freely selectable) Type Measuring range (air) Process connection Performance data Media (real gas calibration) GCX-A from 0... 50 mln/min to 0... 600 mln/min G¼" GCX-B from 0... 600 mln/min to 0... 6000 mln/min G¼" GCX-C from 0... 6 ln/min to 0... 60 ln/min G¼" GCX-D from 0... 60 ln/min to 0... 450 ln/min G½" Air, O2*, N2*, He, Ar, CO2, H2, CH4, C3H8 (other gases and gas mixtures on request) *O2 & N2 are calibrated with air Accuracy (air & equivalents) Eco: ± 2.0% of full scale; ranges > 200 ln/min ± 3.0% of full scale Special: ± 1.0% of full scale up to 50 ln/min Turndown ratio Eco: 1 : 50 Special: 1 : 100 Response time Max. 300 msec (depending on filter settings) Flow update by sensor 40 msec (battery mode 500 msec) Display update 240 msec (battery mode 500 msec) Repeatability ± 0.5% of full scale Longterm stability < 1% of measured value / year Power supply Meter GCM & Regulator GCR Standard AA battery (lifetime in months depending on operation) or Micro-USB power supply (DIN 62684) Option: External power +8...30 Vdc (power consumption max. 120mA) Power supply Switch GCS & All-in GCA Operation pressure External power +8...30 Vdc (power consumption max. 300mA) or Micro-USB power supply (DIN 62684) 0.2 11 bar a Temperature (environment/gas) 0 50 C Materials Seals Anodized aluminium, optional stainless steel electropolished FKM, optional EPDM (FDA) Pressure sensitivity < 0.2% / bar of reading (typical N2) Temperature sensitivity < 0.025% FS measuring range type / C Warm-up time Integration Display Process connection Inlet section Mounting orientation < 1 sec. for full accuracy Touch display (128x64 px) with automatic position adjustment (position sensor) Backlighted only with external power supply (Micro-USB or 24 Vdc) G¼" (BSPP* female) up to 60 ln/min, G½" (BSPP* female) up to 450 ln/min *British Standard Pipe Parallel None required Any position, consult manufacturer above 5 bar or vertical mounting Connection cable For external power supply or alarm module: 2 m with fly leads Safety Test pressure 16 bar a Leak rate < 1 x 10-6 mbar l/s He Environmental protection IP-50 EMC EN 61326-1 Options Panel Mounting Kit Vacuum Fittings Various Inlet and Outlet Fittings

Worldwide Flow Network Vögtlin Sales & Service Hub North America: International Headquarter: Vögtlin Sales & Service Hub China: AW-Lake Company 2440 W. Corporate Preserve Dr. #600 Oak Creek, WI 53154, USA Phone +1 414 574 4300 Fax +1 414 574 4301 info@aw-lake.com www.aw-lake.com Vögtlin Instruments GmbH Langenhagstrasse 1 4147 Aesch BL, Switzerland Phone +41 61 756 63 00 Fax +41 61 756 63 01 info@voegtlin.com www.voegtlin.com KEM flow technology (Beijing) Co., Ltd. Rm. 906, Block C, Ruipu Office Bldg, No. 15, HongJunYingNan Road, Chaoyang District, Beijing 100012, China Phone +86 10 849 29567 info@kem-kueppers.cn www.voegtlin.cn Find your local Vögtlin sales partner on our website: www.voegtlin.com Vögtlin Instruments GmbH gas flow technology Langenhagstrasse 1 4147 Aesch (Switzerland) Phone +41 61 756 63 00 Fax +41 61 756 63 01 www.voegtlin.com info@voegtlin.com 2017 Vögtlin Instruments GmbH Switzerland subject to technical change 329-2017_en_infocompact V171019