Instruction manual red-y compact series

Similar documents
Battery Powered Digital Mass Flow Meters for Gases

Battery Powered Digital Mass Flow Meters for Gases

Battery Powered Digital Mass Flow Meters for Gases

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

GMH 285 / GMH 285-BNC

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Analog Room Pressure Monitor RPC Series

EC3-X33 Stand-alone Superheat Controller Technical Data

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents

Software Version 2.01 LEVEL MONITOR MODEL 220

R1000 / R1040 / R1080

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

testo 316-EX gas leak detector Instruction manual

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

MANUAL Oil Level Sensor

OPERATING MANUAL Enertronic Control System 2

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

Advance Optima Module Magnos 17

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

89BSD Digital Output

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Standard SPECIFICATIONS FEATURES APPLICATIONS

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

OPTISENS TUR 2000 Technical Datasheet

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

Operating Instructions

U5600. Wireless Pressure Transducer SPECIFICATIONS

IMR IX176 Portable Gas Detector User Manual

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

Energy management function at adsorption dryer PDAD

LABORATORY ILLUMINATED FLOTATION BATH

TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Flameproof Manual Call Points

MANUAL Overflow sensor NVF-104/34-PF

FIRERAY 5000 range USER GUIDE

86BSD Digital Output

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Dissolved Oxygen Measurement liquisys S COM 223 / 253

HIn3550 Magnetic Field Monitor User's Manual

U5700 Submersible Liquid Level Pressure Transducer

OIL COOLER INSTRUCTION HANDBOOK

USER S MANUAL INTERSYSTEM PRESSURE TRANDUCER TYPE PM-22

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

MCS 4000 Control Panel

HOBO U14 Data Logger User Manual

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH.

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

Precision Infrared Thermometer. Users Manual

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

U5300 Industrial Pressure Transducer

Class 1 laser beam sensor safe for your eyes

BME680 Self-test application note

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Technical Manual. LeakFilm Sensor. Film Type Liquid Leak Detection Sensor

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

Model gffoz Process Ozone Sensor (In-Line)

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

Operating instructions

Service package PDAD- -SP (en) Assembly instructions d [ ]

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

SEC Signature Process Gas Analyzer

Air Comfort. Installation instructions (English) A

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Instruction manual. Analyt 2 / Analyt 3

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Sub psi SPECIFICATIONS

LIGHTING TEF 9980 STATUS LIGHT, MAIN LIGHT & REPEATER LIGHT ZONE 1, ZONE 2 & SAFE AREA USER MANUAL

LABORATORY OVENS MODELS INCLUDE: TO-152G & TOH-152G TO-152F & TO-235F DEHYDRATING OVENS MODELS INCLUDE: TD-150F TD-330F TD-500F

Netbiter Tank Sensor

CASSETTE UNIT. Comfort Circle

Airflow Sensors Line Guide

Chargebuster Ion Gun Installation, Operation and Maintenance

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

DP86 Constant Voltage with Fitting

Snifter ATEX22 VERSION. User Manual. Distributor

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Rules for Classification and Construction Additional Rules and Guidelines

Airflow Sensors Line Guide

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

M7100 Pressure Transducer

Transcription:

Instruction manual compact regulator GCR compact all-in GCA compact meter GSM & compact switch GCS Vögtlin Instruments AG flow technology Langenhagstrasse 1 4147 Aesch (Switzerland) Phone +41 (0)61 756 63 00 Fax +41 (0)61 756 63 01 www.voegtlin.com info@voegtlin.com

Instruction manual compact meter GCM compact regulator GCR compact switch GCS compact all-in GCA Copyright 2005 Vögtlin Instruments AG, Switzerland : Editing: Daniel Walliser, Christian Mahrer Design: Michael Huber You will find up-to-date information on our products on the Internet at www.red-y.com 00 2

Table of Contents 01 Introduction 4 Operator Benefits Service and Quality Guarantee 02 Mode of Operation 6 Measurement principle CMOS Technology 03 Technical Information 8 General Specifications of the Device Mechanical Specifications Electrical Data Display Measurement Ranges Connector Assignment Conversion Factors for other Gases Loss of Pressure Temperature Compensation Pressure Compensation 04 Mounting & Installation 11 General Tips Installation Position/Location Mechanical Piping Electrical Connection / Power Supply Gas Supply 05 Operation & Service 13 Warm-Up Time Zero Point Check Service Cleaning in the Event of Soiling Replacement of Battery Returns 06 Alarm & Switch Function 15 Individual Functions in Detail Diagram of Function Settings Alarm situations 07 Totalizer 18 General Function Reset 08 Dimensions 19 09 Annex 21 Drop of Pressure Type Code Contamination Statement 00 3

Introduction 01 Welcome With red-y you get the latest, most modern CMOS sensor technology. CMOSens TM is a technology label and stands for a modern process in which the sensor and the signal processing are combined on a highly integrated chip. This manual will familiarize you with the installation and operation of your red-y. We therefore ask you to read this manual carefully and to contact your sales partner with any questions or doubts. We have prepared this manual very carefully in order provide you with appropriate and precise information and instructions. However, no liability is assumed for any errors. Operator Benefits Ultimately, a technology only represents a means to an end. Therefore all of our efforts are aimed at the requirements and wishes of the user of this instrument and his measurement and regulation tasks: - Battery-operated thermal mass flow meters - Optional alarm function - Compact, easy-to-install measurement or regulation unit - CE approved - Easy maintenance and service - Easy expansion of functionality - 3-year guarantee - Top performance in response, dynamics and accuracy - Matching options and accessories Service and quality We continuously improve the quality of our products and services. Only with use does it ultimately become clear whether the right product has been selected. Thus, we attempt not only to propagate good service and high quality, but to live it every day. Guarantee The guarantee for red-y for gasflow products extends to material defects and production flaws. The guarantee maximum is the replacement of the equipment at no cost. Claims are omitted in the case of inappropriate use, external effects in general, excessive heat or dropping. We are always grateful for information on existing defects, for suggestions for improvements, and for critiques. 01 4

Introduction Tips and Warnings Before putting the instrument into use, these operating instructions should be read thoroughly. Improper use, errors for lack of understanding and the consequences arising from this, can lead to the destruction of the instrument or even the endangerment of personnel. The equipment should be put into operation and serviced by appropriately qualified personnel only. The proper handling of the products is an absolute requirement for its trouble-free operation. Electrostatic discharges can destroy the electronic components of this measurement and regulation unit. 01 5

Mode of Operation 02 A bit of theory Measuring principle The measuring principle of thermal flow measurement is perfectly suited for the measurement of gas flows. One of the significant advantages is that the measurement is largely independent of pressure and temperature. By contrast to volumetric principles, pressure and temperature do not have to be additionally measured. Although the principle yields mass as a measurement result (e.g. g/min), most devices are calibrated to standard volumes (e.g. ln/min). One possible explanation is the fact that the comparability of the measurement results with other principles is given with this. Since the thermal flow measurement depends on the type of gas, in addition to the specific heat, the standard density (0 C, 1,01325 bar a) for the conversion to standard volume is also used. With all design options of the measuring principle, there is always a heater and one or more temperature-measurement points and the gasflow draws heat from the heater. With the red-y mass flow meter, a constant heating power ensures a temperature difference that is directly proportional to the gas flow rate. In the flume, a temperature measurement is followed by a heater, and then a temperature measurement again. The figure below illustrates this process. If the flow rate=0, the heater H uniformly distributes the heat, for which the temperature difference T1-T2 equals zero. Two effects occur with the flow rate that lead to a temperature difference: First, the temperature sensor T1 at the entrance detects a lower temperature. This happens because of the cooling of the entering gas, which theoretically drops to the ambient temperature respective of gas. Secondly, the gas flowing over the heater carries heat to the temperature sensor T2, located after the heater, and thus increases this temperature. The temperature difference is in direct proportion to the mass flow. T2 T1 H T2 ΔT flow ΔT T1 Tenvironment Figure 2: Schematic illustration of how thermal mass measurement functions CMOS Technology Red-y measurement and regulation units feature a new basic technology that sets standards for maximum precision sensor systems. The fusion of a semi-conductor chip with sensor technology results in a highly integrated system solution that is impressive for its excellent sensor precision, as well as digital intelligence and reliability. The most notable advantages to the customer are the outstanding precision of the sensor, the rapid response time and a dynamic measuring range that no system has attained up until now. Thanks to the compact single chip design, CMOSens TM -based sensors are extremely resistant to electromagnetic interference (EMI), a significant technical advantage of this ultra modern sensor technology. With CMOSens TM, the sensor element, amplifier and A/D converter form a unit on the same silicon chip. 02 6

Mode of Operation The digital intelligence linked with the CMOSens TM sensor permits the emission of a fully calibrated, temperature-compensated output signal. The CMOSens TM intelligence integrated onto the chip thus facilitates an extremely simple processing of the emitted measurement data. CMOS is a standard technology for the manufacture of integrated circuits. CMOS chips are generally known as semi-conductor chips, silicon chips or computer chips. They are widely used in PCs, mobile telephones and many other information technology devices. 20.0 Battery LCD Power Supply / Alarm contact or SPI μp EEPROM NEXT SET Push-buttons Sensor μp Manual Control Valve Sensor Flow rectifier Flow divider Figure 2: Block diagram of the hardware 02 7

Technical Information 03 Technical Information General Specifications of the Device Accuracy +/- 1% of full scale Dynamics Standard measurement range 2 100 % within the specification Signal suppression less than 2% of full scale +/- 1% from measurement value < 1% from measurement value / year Repeatability Long-term stability Temperature coefficient - Pressure coefficient < 0,2% / bar (typical N2) Operating pressure up to 10 bar g Temperature range 0 50 C Leak rate 1 x 10-8 mbars l/s He Heat-up period 30 minutes for maximum accuracy Mechanical specifications Materials Design Code A (Alu) Design Code S (high-grade steel) Sensor Sealing material Process connection Protection category Aluminum, nickelized brass, stainless steel Stainless steel PBT, epoxy FKM, optional EPDM or PTFE Inside thread G1/4", G1/2 on both sides, optional with compression fittings (see accessory annex) IP-50, front side IP-65 Electrical data Supply voltage Battery operation With battery module, useful life ca. 2 years External feed + 24 V dc +/- 10% Alarm contact (switch and all-in) Function Max voltage Max current Display LC Display Floating change-over contact 24 Vdc 1 A For present flow rate with bar graph and the corresponding unit. Configuration parameters for the alarm function 03 8

Technical Information Measurement Ranges Red-y measurement and control devices are supplied with standard measurement ranges for air. As an option, the devices are available with individual measurement ranges and, upon request, can be calibrated with other gases. Standard Measurement Ranges Code Meas. range Unit Code Meas. range Unit A4 200 mln/min C4 20 ln/min A5 500 mln/min C5 50 ln/min B4 2000 mln/min D3 100 ln/min B5 5000 mln/min D4 200 ln/min Connector Assignment Instruments with the switch or external power supply are fitted with a cable (2m length) with the following assignment: Color Assignment Color Assignment white + 24 Vdc grey AL1 normal open brown 0 Vdc pink not assigned grenn AL1 common blue not assigned yellow AL 1 normal closed red not assigned Conversion Factors for other Gases Every instrument is fully and automatically calibrated on an ultra modern calibration system. The internal conversion to the defined medium is done according to the application. Should you change the mass medium, this may be corrected via conversion factors. For this, contact your Insentys sales partner. Depending on the medium, these conversion factors generate an additional measurement error. Note In the case of plant calibration with a gas other than air, an increased zero offset may be displayed when the device is not operated with the calibrated gas. Pressure Loss The thermal mass flow meters feature little pressure loss. This essentially depends upon the medium, operating pressure and the flow rate. In the annex (chapter 08/page 19) you will find a table that shows the typical course of pressure loss in air, 20 C, 1,013 bar a for the three measurement devices. The pressure loss for other gases can be calculated using the formula. Δ required P = ρ required Δ P 1. 250 Please note that pipes that are two small and unsuitable fittings are often the cause of excessive pressure loss in the system. For trouble-free operation, devices with manual control valve require a certain pressure differential, which is specified on the nameplate. 03 9

Technical Information Temperature Compensation Thermal mass flow meters measure the flow of gases to a large extent independent on pressure and temperature. Varying temperatures are automatically compensated by the measurement device. The sensor measures gas temperature and automatically calculates a correction value using a three-dimensional value table. Pressure Compensation With the calibration, the operating pressure specified with the order is also taken into consideration. With pressure changes, an additional error can occur. Please note that the operation of the manual control valve cannot be guaranteed if the pressure differential is too low or too high. 03 10

Mounting & Installation 04 Mounting & Installation General Tips Check the packet for external damage and contact us immediately in the case of visible damage. Compare the contents of the packet with the delivery slip and check for completeness and technical compliance. This product is a high-precision measuring instrument. We advise you to select the installation site carefully and to follow the instructions and suggestions below. Before installation, be sure that the data on the nameplate corresponds to the use, and that the maximum pressure occurring in the system are lower than the specified test pressure of the device. Installation Position/Location We recommend a horizontal installation position. With higher pressure(> 5 bars), depending on the medium, an additional offset error can occur with a vertical installation position. Check that no heat sources or electrical sources with strong emissions are found near the measuring device. Avoid constant vibrations or other disturbing mechanical effects (stress). If there is a risk of fluid backflow during malfunction, then you should not mount the measuring device at the lowest point of the pipe. Mechanical Pipes The pipe work is very important, and this is often underestimated. Inlet paths, dead volume of the correct amount, proper grounding, clean pipes and leak-free connections have a decisive effect on the quality of the measurement. Be sure that the piping used is absolutely clean. Use suitable pipe materials (compressive strength, durability). With permanent pipes, it is also recommended that the device be fixed with the mounting holes provided for this. Avoid, when possible, a 90 angle directly at the inlet. If there is no other possibility, consult your sales partner. Use appropriate fittings, which are preferably sealed with o-rings on the front side against the body of the device. Please do not hold on the housing while tightening the fittings. Never use liquid sealant! If it has not hardened, it can spread all through the measuring device during flow. Optimize the pipe length between pressure reducing unit and flow meter. A certain dead volume must be available with high flow rates in particular. The pipe diameter must likewise be adapted to the flow rate. Pipe sections that are too small cause high pressure loss and can impair the operation of the device. Check the piping for any leaks. The measuring devices have a flow rectifier. Nevertheless, with high flow rates (> 50 ln/min), we recommend that you install an inlet path (10 times pipe diameter). With critical applications (e.g. consumption metering with gas supply), we recommend the installation of a bypass system with which you can continue to draw gas in the case of service or repairs. 04 11

Mounting & Installation Electrical Connection / Power Supply With the battery-operated devices, mount the battery module. Then the measuring device is ready for use. The useful life of the battery module is about 2 years, but this depends on use. With constantly changing flow rates, the useful life may be shorter. We advise you to use only original battery modules. With the external power supply and alarm options, you receive a connector cable with loose ends. The assignment is printed on the cable. You have the option of turning the cable outlet by 180º. To do this, you open the cover in back by hand and turn the plastic block to the desired direction. Turning the cable outlet by 180 The supply voltage must be + 24 Vdc (+/-10%) and have the lowest possible residual ripple. Please note that voltage drops may occur with longer connecting cables. Likewise, be aware of possible earth loops when you ground electrically conductive pipes. Gas Supply We recommend that you pay close attention to the gas supply line. Contamination in the form of water, oil or dust are harmful to any measurement principle. Particularly in the case of air supply with compressor systems, cleanliness cannot always be guaranteed. In case of doubt, install the appropriate filter. If use-related backflows are to be expected, this filter should also be installed at the outlet. Please monitor possible pressure loss due to the filter elements. The gas supply should be oversized and have the capacity of at least twice the flow rate of the attached measuring device. Monitor the performance of the pressure-reducing unit, as well. Never install the pressure regulator directly in front of the measuring device. Check for possible pressure loss along the pipeline system. Flow regulators especially require defined pressure ratios for proper functioning. With very low flow rates, pressure reduction is oversized and gas is only periodically fed (on-off regulation). This becomes evident in the form of periodic fluctuations in the regulation or changes in the flow rate. Avoid abrupt pressure buildup in the system. This can lead to damage. Charge the system with pressure only after establishing the electrical connections. Be sure to have an inert gas (e.g. nitrogen) available for flushing in the case of dangerous, abrasive or corrosive gases. 04 12

Operation & Service 05 Operation & Service Heat-Up Time Right when the device is turned on, red-y is ready for use. For the most precise measurements, however, red-y is ready in 30 minutes (option of external feed). Before turning on, please be sure that the wiring is correct and is installed according to the installation plan, and that the gas connections are also mounted in accordance with the installation instructions of the manufacturer. Zero Point Check Without any special specifications for the installation position of the device, the zero point is aligned at operating temperature and horizontal installation position before delivery. If the device is installed vertically, a value can be read out at a zero flow rate according to operating pressure. During the check, be completely sure that no gas is flowing. In the case of a shift in the zero point, please contact your sales partner. Service With proper operation, red-y does not require any routine service at all. If the measurement value is in a quality-relevant range (e.g. ISO 9001), we recommend a periodic check of calibration. The interval depends strongly on use. Cleaning in the Case of Contamination Should there be suspicion of contamination (sudden deviation of measurement value in familiar processes, visible traces in the piping, etc.), try flushing the device with a dry inert gas. Depending on the contamination, it may be necessary to dismantle the device. Tips - Use only designated tools. - Handle the device and individual components with extreme care. - Ensure that the dismantling area is clean. - The guarantee lapses at all events with the dismantling of the device. - Never loosen a torx screw. - Do not touch the electronic circuit board or electronic components under any circumstances. - After the cleaning, you should have the device checked by your sales partner at the first opportunity. Dismantling Flow Module - Disconnect the gas and electrical connections. - On the inlet side, carefully unscrew the flow rectifier together with the flow divider. With this design, there are no o-rings in this area. You can now clean the entire flow module with a mild solution (e.g. IPA). Afterwards, ensure that the bored holes are absolutely clean, dry and cleared. 05 13

Operation & Service Battery Replacement If low bat appears in the display, we recommend that you change the battery or at least have a new battery module available (Art. Nr. 328-2211). This module can be obtained from your Insentys sales partner. We recommend the following procedure with the replacement of the battery: Changing the battery requires no tools at all. The battery module snaps into two lateral housing clips. Hold the measuring device firmly with one hand on the main body (metallic part) and pull the battery module out toward the back, keeping it as level as possible. Then, place the new module in as straight as possible from the back, and press in the direction of the measuring device until it snaps into the clips. After the battery is changed, the device goes through a self-test and is then ready for use. Replacement of battery module Verbrauchte Batterien gehören aufgrund ihres hohen Schwermetallgehaltes nicht in den Hauskehricht. Bitte übergeben Sie diese den entsprechenden Sammelstellen, damit sie dem Recycling-Prozess zugeführt werden können. Returns With the return of a measurement or regulation device, use the original packaging if possible, or other appropriate packing. Please inform us of the reason for the return in order to spare any unnecessary callbacks and delays. Should the device come in contact with dangerous substances, please clean the device carefully, notify us and pack the device tightly. Please fill out the contamination statement. You will find this in the annex on page 21 or on the enclosed CD. If you have any further questions, please contact your sales partner. 05 14

Alarm & Switch Function 06 Alarm & Switch Function Individual Functions in Detail Resetting the Alarm Condition AL CLR In the case of alarm condition, the alarm can be reset. This is only possible if the manual option is selected in the corresponding menu (resetting the alarm AL res). The alarm condition is shown in the display. Setting the Alarm Setpoint ALSETP The desired threshold can be set with the +/- keys. This value can be between 0 and the maximum possible measurement value. The threshold unit corresponds to the measurement value. Alarm Functions ALFUNC Measurement values greater (AL hi) or lower (AL lo) than the threshold value that are considered an alarm condition can be defined. In addition, the alerter function can be deactivated (AL off). Failsafe Mode FAILSA If this function is activated, the switching logic of the outlet is operated in such a way that alarm conditions, as well as device failure and line break can be detected. In the examples, you will find the switching manner of the contact in the case of activated function. Setting the Alarm Delay Time DELAY An adjustable time of 0 180 sec., during which the alarm condition should last until the alarm contact is appropriately activated. If the upper or lower threshold is surpassed, the triggering of the alarm is prevented. Setting the Alarm Hysteresis HYST Should the momentary flow rate and the established threshold be close to one another, setting the hysteresis prevents the alarm from constantly going on and off. The value can be from 0 to 10% of the maximum possible target value. Setting the Low Alarm Suppression losupr If a minimum alarm (AL lo) is configured, and if the flow rate is at zero from the start, this triggers the alarm immediately. With the low suppression function, this can be avoided. Here, the alerter function is only activated if the flow rate is over the threshold. Alarm Reset Mode Al res There are two options: Auto: The alarm automatically resets after the flow rate returned to normal condition. Manu: Manual reset with the function AL clr. 06 15

Alarm & Switch Function Diagram of Function Settings Measuring 20.0 both button pressed for 2s no button pressed for 2s Alarm reset al clr one button pressed for 2s Alarm Setpoint alsetp no button pressed for 10s SET no button pressed for 2s adjustable with +/- 1200 0 - max. Flow 2s NEXT Alarm Functions alfunc NEXT Failsafe Mode Failsa no button pressed for 10s SET no button pressed for 2s no button pressed for 10s SET no button pressed for 2s adjustable with +/- AL LO AL hi al off adjustable with +/- on off NEXT Alarm Delay Time Delay no button pressed for 10s SET no button pressed for 2s adjustable with +/- 000 s - 180 s NEXT Alarm Hysteresis Hyst no button pressed for 10s SET no button pressed for 2s adjustable with +/- 0-10 % of full scale NEXT Low Alarm Suppression Losupr no button pressed for 10s SET no button pressed for 2s adjustable with +/- on off NEXT NEXT Alarm Reset Mode al res no button pressed for 10s SET no button pressed for 2s adjustable with +/- Auto manu no button pressed for 10s 06 16

Alarm & Switch Function Alarm situations Situation 1 / Parameters: Function Value Function Value Function Value ALSEtP 2.5 DELAY 10s AL res AUto ALFUNC AL LO HYST 0.5 FAILSA Off LoSUPr On Setpoint Hysteresis Range Situation 2 / Parameters: Function Value Function Value Function Value ALSEtP 2.5 DELAY 10s AL res MAnu ALFUNC AL HI HYST 0.5 FAILSA On LoSUPr OFF Range Setpoint Hysteresis 06 17

Totalizer 07 Totalizer General The Totalizer function can be activated by the manufacturer. Function The instrument calculates the integrated value of the gas volume. The added up value is periodically displayed and stored in intervals of 15 minutes in the non-volatile storage (EPROM). In the event of a power disruption, the Totalizer therefore displays the correct total volume. It is, however, possible that the gas volume for the past 15 minutes may be lost. The added-up volume of the Totalizer and the flow value are alternatively displayed. The display intervals are adjusted by the manufacturer as follows: Flow: 5s Total: 3s The unit of the Totalizer volume is adjusted by the manufacturer. Reset The Totalizer function can be activated by the manufacturer in two different modes: 1. Totalizer without reset In the event of a power disruption the most recently registered value from the non-volatile storage (EEPROM) is loaded and added up further. 2. Totalizer with reset In the event of a power disruption, the Totalizer volume is set to zero and from then on resumes adding-up. 07 18

Dimensions 08 Dimensions Dimensions smart controller G1/4 12,5 14 25 43.3 25.5 69 (25.5) 43.5 25 ø19 (12.7) 88.6 12.7 114 25 8.7 ø4.8 ø6.8 31.8 25 8.7 3 (25.5) 69 43.5 G1/4 x 12 12,5 17 A 4xM4 x 7 (inlet and outlet) 17 Mit externer Speisung / With external power supply / Avec alimentation externe 30 B 43.3 ø19 25.5 (12.7) 12.7 Befestigungsgewinde / Mounting threads / Filets de fixation Ansicht A / View A / Vue A Ansicht B / View B / Vue B 15 M4x5.5 M4x5.5 15 M4x5.5 M4x5.5 23.5 67 23.5 67 08 19

Dimensions Dimensions smart controller G1/2 1.3 13 ø4.8 ø6.8 53.3 35 B 17.5 41.8 27 A 4xM4 x 7 (inlet and outlet) 27 G1/2x15 36 53.5 1.3 35 (52.7) 88.6 18.7 160 Befestigungsgewinde / Mounting threads / Filets de fixation Ansicht A / View A / Vue A 25 G1/2x15 M4x5 M4x5 15 130 Ansicht B / View B / Vue B 25 M4x5 M4x5 15 130 08 20

Annex 09 Annex Pressure Loss Pressure Loss 500 mln/min (Air) Pressure Loss mbar 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 0 100 200 300 400 500 Flow mln/min Pressure Loss 5 ln/min (Air) Pressure Loss mbar 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 1 2 3 4 5 Flow ln/min Pressure Loss 50 ln/min (Air) Pressure Loss mbar 120 100 80 60 40 20 0 0 10 20 30 40 50 Flow ln/min 09 21

Annex 180 Pressure Druckverlust Loss Typ 200ln/min - 160 140 Pressure Druck (mbarü) g) Druckverlust in mbar Pressure in mbar 120 100 80 60 40 20 0 0 50 100 150 200 250 Q in ln/min 09 22

Annex Type Code Main function G gasflow Series C compact series Function M Meter R Regulator S Switch A All-in Measuring Range (Air) A3 100 mln/min G1/4", 25x25 A4 200 mln/min A5 500 mln/min A9 Custom range B3 1'000 mln/min B4 2'000 mln/min B5 5'000 mln/min B9 Custom range C3 10 ln/min C4 20 ln/min C5 50 ln/min C9 Custom range D3 100 ln/min D4 200 ln/min G1/2", 35x30 D9 Custom range Class S Standard, +/-1% of full scale, 1:50 K Custom Materials A Aluminum, FKM * B Aluminum, EPDM S SS, FKM * T SS, EPDM K Custom Power Supply B Battery F External Supply 24 Vdc Standard T External Supply 24 Vdc Totalizer K Custom Materials Valve regulator & all-in A Nickelized brass, FKM B Nickelized brass, EPDM S SS, FKM T SS, EPDM K Custom N No valve Valve 10 NS 1.0 15 NS 1.5 20 NS 2.0 25 NS 2.5 30 NS 3.0 35 NS 3.5 88 Valve not defined 99 Custom 00 No manual valve Code G S C - B2 S A - A N 05 * = Standard 09 23

Annex Contamination Statement With return of devices, please fill out the following statement completely, especially the reason for the return, the type of residue and cleaning in the case of soiling, as well as indication of hazards. Devices Type Code: Serial number: Reason for the return: Type of contamination Device came in contact with: Cleaned by us with: For the protection of our employees and for general safety during transport, proper cleaning and the use of an appropriate packing are mandatory. Can you provide any further information on the contamination? inert (no danger) corrosive caustic must not come in contact with moisture oxidizing other hazard Legal Declaration We hereby affirm the accuracy and completeness of the above information. Company: Address: Telephone: Contact person: Date: Signature: On behalf of the entire red-y for gasflow team, we thank you for your understanding. 09 24