Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

Similar documents
Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

Tankless On Demand Electric Water Heater

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

Tankless Electric. Model JTX Tankless Booster. Features. Tankless Booster Heater For Commercial Kitchen Use

Indirect Fired Water Heater

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

ASME Packaged Electric Water Heater

Shipboard Electric Water Heater

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

Light Duty Commercial Electric Water Heater

Semi-Instantaneous Indirect Fired Water Heater

Tepid Water Delivery System

Packaged Semi-Instantaneous Steam Fired Water Heater

Shipboard Electric Water Heater

Shipboard Electric Water Heater

Heat Pump Water Heater

Packaged Steam Fired Water Heater

ASME Packaged Indirect Fired Water Heater

High Capacity Instantaneous Steam Fired Water Heater

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL MODEL TX / HX TANKLESS WATER HEATER

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

DI/RO GAS TANKLESS WATER HEATER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL MODEL JTX / JHX TANKLESS BOOSTER HEATER

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL MODEL JTX TANKLESS BOOSTER HEATER ELECTRIC HEATER COMPANY

SECTION DOMESTIC WATER HEATERS

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL TANKLESS WATER HEATER

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Control and power circuit fusing to meet N.E.C.

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

INSTANT-FLOW C-MICRO WATER HEATER

TRONIC 6000C WH17 & WH27 Electric Tankless Water Heaters

CLE SERIES Fluid heating for emergency eyewash stations

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

Easy Installation & Service

INSTANT-FLOW C-MICRO WATER HEATER

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

The water heater evolved. Hot water. Perfected.

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

Electric Tankless Water Heaters

RQE Series Temperature Controllers

Tempra / DHC-E. Simply the Best. The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control ENGINEERING EXCELLENCE

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

Installation and Operation Guide

Shop Online Eccotemp.com/products. Store Locator Eccotemp.com/locator. Product Support support.eccotemp.com.

Flexible Heaters W A T L O W. Temperature Sensors and Controllers SERIES EHG

HWD-2110 Hot Water Dispenser

Electric Tankless Water Heaters. Most Advanced Line of Residential & Commercial Instant Heaters. Series

S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

HEATING WATER FOR OVER 50 YEARS

TABLE 1 Electrical Specifications

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

The Finest Tankless Electric Water Heaters Available! Commercial Application Point-of-Use Tankless Electric

96% COMMERCIAL INDUSTRIAL HEATER. Condensing Gas Water Heating System. Thermal Efficiency

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

HIGH-EFFICIENCY COMMERCIAL GAS WATER HEATER 3-Year Tank Warranty 1-Year Parts Warranty

HOT WATER WITH THE SNAP OF A FINGER. Mini Tanks. Basic Heaters. High Capacity Heaters. Model CMT. Model SR, M & E. Model ER Series

TABLE 1 Electrical Specifications. Phase

5 (34) 10 (69) 45 (170) 64 (242) 65 (246) 92 (348) 90 (341) 127 (481) 85 (322) (227) 80 (303) 113 (428) 148 (560) 105 (397) 141 (534) 100 (379)

POINT-OF-USE WATER HEATERS

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

HL SERIES Fluid heating for commercial applications

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Tempra TM / DHC-E Simply the Best. Engineering Excellence. The Finest Tankless Electric Water Heater Available!

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

FOR SERVICE TECHNICIAN S USE ONLY

SYSTEM DESIGN REQUIREMENTS

OPERATION & INSTALLATION MANUAL

Installation and Troubleshooting Instructions for Electric Tankless Commercial Water Heaters CE 12 KW, CE 15 KW, CE 18 KW CE 24 KW CE 27 KW CE 48 KW

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Installation and Operation Guide

C1N & C2N SERIES Fluid heating for light industrial applications

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

AT SERIES C ELECTRIC BOILERS ABSOLUTE EFFICIENCY. TOTAL COMFORT! Save Money, Save Space, Save the Environment! RESIDENTIAL / LIGHT COMMERCIAL

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

Models. Options. Standard Features. LoH 2 O

INSTALLATION GUIDE AND OWNER S MANUAL. AccuMix II ELECTRIC INSTANTANEOUS WATER HEATER WITH ASSE 1070 APPROVED MIXING VALVE

HWD-2105 Hot Water Dispenser. NOTICE TO INSTALLER: Please leave this book with the machine.

ASME and Non-ASME Storage Vessels

PRO SERIES IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

FOR SERVICE TECHNICIAN S USE ONLY

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Transcription:

Point-of-Use Tankless Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Features Heavy Duty Construction Reliability Constructed with high grade materials to ensure long operating life Simple to install and operate Compact space saving design Engineered to ensure reliable operation Wide selection of sizes High Efficiency On demand heating eliminates costly and cumbersome storage tanks Instantaneous design reduces stand-by heat loss and significantly lowers operating costs compared to traditional storage tanks Electric Tankless Water Heater ND FRIE LY O C Point-of-Use Single or Multiple Lav Sinks Condos & Apartments Whole House EFFICIENT SAVING E ER 8% ERGY & WA T EN 9 Applications ANSI/NSF 5 The Hubbell Tankless is a highly efficient and compact electric tankless water heater that is easy to install, operate and maintain. Products marked with the Lead-Free logo comply with the Safe Drinking Water Act (SDWA) requirements of a weighted average of less that 0.25% lead content on wetted surfaces of pipes, pipe fittings, plumbing fittings and fixtures. Tankless Water Heater For Residential and Commercial Use The Hubbell Tankless electric water heater is a highly reliable and easily maintained heater designed for pointof-use or whole house operation. The Hubbell Tankless electric water heater is compact, extremely efficient, takes up minimal space and reduces operating costs. Hubbell s vast experience, meticulous engineering and advanced technology ensure that you can rely on the Hubbell Tankless heater for your water heating needs in even the most demanding applications. The Hubbell Tankless is the right choice for your water heating needs and provides you with an energy efficient, trouble-free and long lasting heater. High Efficiency Compact Electric Tankless Heater

How It Works Hubbell Tankless Features The Hubbell tankless electric water heater contains high powered heating elements that heat water only when there is demand for hot water. When hot water is needed, a built in flow sensor measures the exact flow rate, and that data combined with temperature readings at the heater s inlet and outlet are processed by the electronic temperature controller. This data is continuously transmitted to the temperature controller, which constantly calculates the precise amount of power (kw) needed to achieve the desired temperature. A zero cross over firing signal is sent to the fast acting triacs in order to modulate the heating elements to the precise level needed to meet demand. The Hubbell tankless heater uses only as much power as is needed, while delivering accurate and consistent hot water temperature. Heater Overview - 3 Element Model Shown Commercial Quality Heating Elements Incoloy sheathed for long life Safety Thermostats Auto resetting Hi-Limit thermostats protect against over heating Stainless Steel Exterior Sleek design and corrosion resistant for long life Heating Chamber All copper and bronze construction Outlet Thermistor Provides feedback to ensure consistent outlet temperature HOT WATER OUT Drain Port Simplifies winterization process for seasonal installations COLD WATER IN Inlet Thermistor Senses cold water temperature Numeric Digital Display Electronic Temperature Controller is adjustable in 1 increments in either F or C Solid State Switching Triac Modulates heating elements 0-100% to ensure accurate temperatures and long element life Power Terminal Block Universal electrical connection point Flow Meter Measures the flow rate precisely to accurately control hot water temperature Push Fit Connections Simplifies plumbing installation Tankless Standard Specifications Heating Chamber: Copper and Bronze Hi-Limit: 150 F (65 C) Capacities: 3 thru 27 kw Design WP: 150 psi Orientation: Wall Mounted Design TP: 300 psi Voltage: 240 / 220 /208 Volt Elements: Incoloy 800 Phase: 1 Φ Standby Power: < 3 Watts Power Factor: 0.999 Thermal Efficiency 98% + Chamber Warranty: Electrical Warranty: Residential: Commercial: Residential: Commercial: 5 Years 5 Years 1 Year 1 Year Inlet/Outlet Size: 3 /4" Push Fit Enclosure: Stainless Steel Brushed Finish Min/Max Flow: 0.2 GPM Min, 8.0 GPM Max Approvals: culus, UL EPH ANSI/NSF5 Thermostat Range: 32-140 F / 0-60 C Max Inlet Temp.: 150 F 2

Temperature Controller A sophisticated electronic temperature controller with LED digital display provides the user interface. The temperature controller processes all flow and temperature data and calculates the precise amount of power needed to meet demand. Operator Control Capabilities Technical Features Power Limiting: Allows the operator to reduce the power consumption by any percentage to provide installation and operational flexibility and savings. Diagnostics: Display inlet and outlet temperatures, flow rate and error codes to assist in troubleshooting. Cost Calculator: Determine the exact cost of operating the heater. Input your cost per KW Hr and the controller displays total KW HRs consumed, total cost of operation, and total hot water usage (shown in gallons or liters). Temperature Control: Set the digital display to the desired water temperature in F or C. Fully adjustable in 1 increments from 32-194 F (0-90 C). A user adjustable +/- 3 calibration feature provides additional control for superior accuracy. Full Heater Modulation Each heating element is switched on/off using a fast acting solid state triac with zero cross over firing control. This switching schema provides full modulation of each heating element, ensuring that the precise amount of heat is added to meet demand. To improve operating efficiency and component longevity, each triac is mounted to a heat sink located on the incoming supply piping so that heat generated by the triac during the switching process is dissipated into the water. Proper Power Integrity All Hubbell tankless water heaters are engineered to operate as a balanced load and operate at 0.999 Power Factor. All load switching in Hubbell tankless models is performed as zero cross over, eliminating phase angle firing interference and associated EMI issues. Full Resource Staging The Hubbell tankless control schema ensures that usage is equalized across all heating circuits. To achieve this, once the controller has calculated the precise amount of kw required, all circuits are energized in a staggered fashion such that each circuit is proportionally and independently energized and then time staggered between circuits. This Full Resource Staging Schema reduces EMI output, increases component longevity and provides highly accurate and consistent hot water temperatures. Building Management Integration Remote Control: Ability to remotely enable or inhibit the heating operation of the unit using one of the following two methods: 1. Customer supplied 24VDC signal is user configu ed for either Inhibit Mode or Normal Operation Mode. 2. Customer supplied volt free contact is user configu ed for either Inhibit Mode or Normal Operation Mode. Priority Control: An integrated SPDT potential free dry contact (NO/NC 10A @ 240VAC) energizes when the unit is heating and de-energizes when not heating. This feature is useful when it is desirable to give the water heater priority over another electrical load to ensure that both are not operational at the same time. A. Inlet and Outlet Valve assembly simplifies installation and includes unions, shut offs, check valve, drain ports and pressure relief valve. B. Air Separator to clear the incoming cold water of micro air bubbles, sand, dirt and rust. Recommended for use with well water systems. C. Descaler kit simplifies the process of cleaning the heater and removal of mineral deposits. D. For heaters suitable for operation with 3 phase voltages please see Hubbell model TX brochure. Liters x 0.2641 = Gallons Gallons x 3.79 = Liters Gallons x 0.003785 = m 3 m 3 x 264.2 = Gallons 1 C T = 1.8 F T Options Metric Conversions F = ( C x 1.8) + 32 C = ( F - 32) x 0.556 psi x 0.06896 = Bar Bar x 14.5 = psi psi x 6.86 = kpa E. Special construction features available. Please consult factory. F. Remote Control Display allows the heater to be installed in a remote location. The 3" x 5" NEMA 4 display enclosure can be located up to 250' from the heater and gives the operator full remote control and monitoring capabilities. G. An ASSE 1070 code compliant Thermostatic mixing valve to increase the amount of hot water available. Valve is 1/2" (-UT) size and adjustable from 80-120 F. Typically used when supplying hot water to multiple lavs from a single water heater. Please note: optional equipment may impact overall dimensions and weight. Please request submittal drawing from factory. kpa x 0.1456 = psi Kg / cm 2 x 14.28 = psi psi x 0.07 = Kg / cm 2 Lbs x 0.4536 = Kg Kg x 2.2 = Lbs 3

Outline Dimensions and Model Selection 3-18 KW Models (2 Element) 13 1 2 " 12 1 2 " Withdrawal Space 12" Model Number KW Selection Chart KW Ratings 240V 220V 208V R003-2S 3 2.5 2.2 R005-2S 4.5 3.7 3.3 R007-2S 7 5.8 5.2 R009-2S 9 7.5 6.7 R0011-2S 11 9.2 8.2 R0014-2S 14 11.7 10.5 R0016-2S 16 13.4 12 R0018-2S 18 15.1 13.5 16 3 16 " 14 1 4 " Side View 11 9 16 " 3 9 16 " 1 3 16 " 2 5 16 " Hot Water Outlet Cold Water Inlet 3" 6" Electrical knockout 3 /4" x 1" x 1 1 /4" Pressure Drop: 3 psi @ 4 GPM Dry Weight: 16 Lbs Wet Weight: 16.5 Lbs Shipping Weight: 17 Lbs 21-27 KW Models (3 Element) KW Selection Chart 17" 16" Withdrawal Space 12" KW Ratings Model Number 240V 220V 208V R021-3S 21 17.6 15.7 R024-3S 24 20.1 18 R027-3S 27 22.6 20.2 16 3 16 " 14 1 4 " Side View 15 1 16 " 3 9 16 " 1 3 16 " 3" 3" 6" Electrical knockout 3 /4" x 1" x 1 1 /4" 4 1 8 " 2 5 16 " Hot Water Outlet Cold Water Inlet Pressure Drop: 3 psi @ 4 GPM Dry Weight: 20 Lbs Wet Weight: 20.5 Lbs Shipping Weight: 21 Lbs 4

Heating Capacity and Amperage Chart Model No. R003-2S R005-2S R007-2S R009-2S R011-2S R014-2S R016-2S R018-2S R021-3S R024-3S R027-3S KW Ratings at Various Voltages Heating Capability in GPM at o F Temperature Rise ( F ( o FΔT) T) Max Amps at 100% output 1 Phase Voltages 240V 220V 208V 40 F T 60 F T 80 F T 100 F T 240V 220V 208V 3 0.51 0.34 0.26 0.20 12.5 2.52 0.43 0.29 0.21 0.17 11.4 2.25 0.38 0.26 0.19 0.15 10.8 4.5 0.77 0.51 0.38 0.31 19 3.78 0.64 0.43 0.32 0.26 17.1 3.37 0.57 0.38 0.29 0.23 16.2 7 1.19 0.80 0.60 0.48 29 5.88 1.00 0.67 0.50 0.40 26.7 5.2 0.89 0.59 0.44 0.35 25 9 1.54 1.02 0.77 0.61 37.5 7.56 1.29 0.86 0.64 0.52 34.3 6.7 1.14 0.76 0.57 0.46 32.2 11 1.88 1.25 0.94 0.75 46 9.24 1.58 1.05 0.79 0.63 42 8.2 1.40 0.93 0.70 0.56 39.4 14 2.39 1.59 1.19 0.96 58 11.76 2.01 1.34 1.00 0.80 53.4 10.5 1.79 1.19 0.90 0.72 50.4 16 2.73 1.82 1.36 1.09 67 13.44 2.29 1.53 1.15 0.92 61 12 2.05 1.36 1.02 0.82 57.6 18 3.07 2.05 1.54 1.23 75 15.12 2.58 1.72 1.29 1.03 68.7 13.5 2.30 1.54 1.15 0.92 64.9 21 3.58 2.39 1.79 1.43 87.5 17.64 3.01 2.01 1.50 1.20 80.1 15.75 2.69 1.79 1.34 1.07 75.7 24 4.09 2.73 2.05 1.64 100 20.16 3.44 2.29 1.72 1.38 91.6 18 3.07 2.05 1.54 1.23 86.5 27 4.61 3.07 2.30 1.84 112 22.68 3.87 2.58 1.93 1.55 103 20.25 3.45 2.30 1.73 1.38 97.3 Note: Alternate voltages including 277, 380, 415, 440, 575 and 600 volt available. Please consult factory for exact KW availability in these voltages. For 3 phase voltages please reference Hubbell model TX brochure. Sizing Formulas Step 1 Solve for the unknown using formulas below. Variables To Solve For: KW Requirement: GPM x o F T x 0.1465 = KW Temperature Rise: KW x 6.824 GPM o F T Flow Rate: KW x 6.824 o F T = GPM Voltage De-Rating Factors Rated Voltage Applied Voltage De-Rating Factor 240 V 230 V 92% 240 V 220 V 84% 240 V 208 V 75% When the actual supply voltage (applied voltage) is different than the design voltage (rated voltage) the resulting KW output will be affected. Please see the chart for typical voltage de-rating factors, or use the following formula. Step 2 Choose the Tankless model with the KW rating which meets the peak demand (GPM) and required temperature rise ( o F T) for your application. Step 3 Choose the supply voltage available. Note the total amperage draw of the unit and verify availability. Applied Voltage 2 Rated Voltage 2 X Rated KW = KW output at applied voltage 5

Master Specification: Point-of-Use Tankless Job Name eng ineer / Architect Representative contractor GENERAL Provide a quantity of packaged type instantaneous electric tankless water heater(s) Model No. as manufactured by HUBBELL Electric Heater Co., Stratford, CT. The entire unit is packaged ready for plumbing and electrical service connections and shall bear the culus listing mark certifying the entire unit to UL499, CSA C22.2 No. 64-M91 and UL EPH Sanitation listed to ANSI/NSF Standard 5. HEATING CHAMBER The heating chamber shall be all Sil-brazed copper and bronze construction. A plastic heating chamber shall not be acceptable. Water heater heating chamber shall be rated for a maximum allowable working pressure of 150 psi. The heating chamber and all electrical controls shall be completely enclosed in a stainless steel case. HEATING CAPACITY The tankless heater shall be rated at KW which will heat GPM of water at F rise ( to F ). Heaters that require the use of a flow estrictor or specialized aerator shall not be acceptable. ELECTRICAL The heater shall be designed to operate at volts, single phase, 50/60Hz and will draw amps only when operating at full power. The immersion heating elements shall be high quality incoloy sheathed and sized to obtain the rated capacity. Each element is to be operated using zero cross over solid state controls. The heating elements shall be fully modulated from 0-100% to provide precise temperature control through the full range of flows. A Hi-Limit thermostat with automatic reset shall be factory installed to disconnect each heating element in the event of an over-temperature condition. An electronic digital display temperature controller shall be user adjustable in 1 increments in either F or C and shall display flow rate, outlet temperature, inlet temperature and provide error indication. A turbine-type flow meter shall be factory installed to provide precise temperature control for water flows as low as 0.2 GPM up to a maximum flow of 8 GPM. Heaters that require greater than 0.2 GPM flow for actuation or restrict flow shall not be acceptable. WARRANTY Hubbell shall warranty all electrical components against defects in workmanship and material for a period of one (1) year from date of start-up and the heating chamber for a full five (5) years from date of start-up (for residential service, five (5) years heating chamber and one (1) year electrical), provided that the unit is started within three (3) months of date of shipment and installed and operated within the scope of the heater's design and operating capability. Labor is not covered under warranty. Each heater shall be shipped with a complete set of installation and operating instructions including spare parts list and approved drawings. All fabrication and assembly shall be performed in the U.S.A. OPTIONS In addition, the tankless electric water heater shall be supplied with the following options: Option Option Option ISO 9001:2008 ISO Committed to continuous improvement... Continuing research results in product improvement; therefore specifications are subject to change without notice. For the most updated information, consult the factory directly. Made in the U.S.A. The Electric Heater Company P.O. Box 288 Stratford, CT 06615-0288 Phone: 203-378-2659 Fax: 203-378-3593 info@hubbellheaters.com www.hubbellheaters.com [REV D]