Models: A5LCY 30 ER A5LCY 40 ER A5LCY 50 ER A5LCY 60 ER A5LCY - II Inverter Y Single Split Series II

Similar documents
Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

INVERTER Y SINGLE SPLIT SERIES II

FWC02AAFNMV1 FWC03AAFNMV1 FWC04AAFNMV1 FWC05AAFNMV1 FWC06AAFNMV1

Models: A5HDC20AR A5HDC25AR. Horizontal Ducted Condensing Unit

INSTALLATION MANUAL AIR COOLED, DUCTED SPLIT TYPE AIR-CONDITIONERS SPLIT TYPE. Part No.:R IM-MHSB-0806-DAIKIN

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Installation Instructions

R407C TECHNICAL MANUAL. Packaged Air Conditioner Rooftop A series. UATP-A and UATYP-A Series. Cooling only & Heatpump [50Hz]

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

42PHW / 42PHQ 42PHQ...K

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Inverter Wall Mounted Series

Inverter Wall Mounted

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

DESIGN & TECHNICAL MANUAL

Installation Instructions

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

INVERTER SPLIT - TYPE

Installation Instructions

Installation Instructions

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

Installation Instructions

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

AIR CONDITIONER CONSOLE

Wall Mounted Split Systems

Wall Mounted Split Systems

Contents. 1. Features Specifications Noise Level Operating Range Refrigeration Cycle Diagram...

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

CENTRAL AIR CONDITIONER SPLIT SYSTEM

DESIGN & TECHNICAL MANUAL

CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Self Cleaning decoration panel

HEAT & COOL MODEL (REVERSE CYCLE)

Installation Instructions

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Air Conditioner CONTENTS CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU. Order No: MAC C1

Room Air Conditioner Service and Parts Manual

HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM

DESIGN & TECHNICAL MANUAL

Split Water Source Heat Pump And Cooling Only Unit

INSTALLATION MANUAL. Model UAT150CGXY1 UAT180CGXY1 UAT240CGXY1 UAT300CGXY1 UAT150CGXY19 UAT180CGXY19 UAT240CGXY19 UAT300CGXY19.

Installation Instructions

technical data Fan coil unit FWB small duct unit

OPERATION MANUAL AND INSTALLATION MANUAL

TECHNICAL & SERVICE MANUAL

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

Installation Instructions

Operating Instructions

DESIGN & TECHNICAL MANUAL

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

DAIKIN AIR CONDITIONER

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

TABLE OF CONTENTS. Air Conditioner CS-MRE12MKE

Installation Instructions

AIR CONDITIONER FLOOR CEILING

TABLE OF CONTENTS. Air Conditioner CS-E24GKES CU-E24GKE CS-E28GKE CU-E28GKE

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

HEAT PUMP INSTALLATION MANUAL

AIR CONDITIONER CASSETTE

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

DESIGN & TECHNICAL MANUAL

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

CU-3E23CBPG, CU- 4E27CBPG,

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

FAN COIL USER MANUAL TC18C2DWB1 TC24C2DWB1 TC37C2DWB1 TC48C2DWB1 TC60C2DWB Innovair Corporation. All Rights Reserved.

AIR CONDITIONER (SPLIT TYPE)

II PCV1 Features

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

YC ON-OFF SERIES. Service Manual

Compact Cassette Type

APPLICATION GUIDE FLATAIR FMC - H FIC - H FSC - H. Horizontal packaged air conditioners kw FLATAIR AGU-MSL E. lennoxemeia.

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

C&H NORDIC Commercial 4 SERVICE MANUAL

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B

FAN COILS wall mounted

INSTALLATION MANUAL Duct Type Series MH FECA

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Owner s Manual Super-Slim Four-Way Cassette

2. FEATURES. Gold aluminum fin is offered as standard material of the condenser heat exchanger of this series of chiller.

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use. Indoor unit 42TVU010, 012, Outdoor unit 38TVU010, 012, ENGLISH

Installation Instructions

INSTALLATION MANUAL For authorized service personnel only.

Installation Instructions

Air Conditioner. user installation & manual manual. imagine the possibilities

BEFORE USING THE APPLIANCE SAFETY PRECAUTIONS AIR CONDITIONER PRECAUTIONS

Horizontal Water Source Heat Pumps And Cooling Only Unit

5) Do not start or stop the unit by inserting or pulling out the power plug.

INSTALLATION INSTRUCTION

Transcription:

Models: A5LCY 30 ER A5LCY 40 ER A5LCY 50 ER A5LCY 60 ER A5LCY - II - 2010 Inverter Y Single Split Series II

Table of Contents A5LCY-II-2010 Table of Contents Nomenclature...1 Indoor Unit...1 Outdoor Unit...2 Product Line-Up...3 Features...6 Application Information...7 Operating Range...7 Refrigerant Circuit Diagram...8 Controller...9 Installation Guideline...12 Sound Data...30 NC Curves...33 Blower Curves...37 Engineering & Physical Data...41 General Data...41 Components Data...47 Safety Devices Data...53 Outline and Dimension...55 Electrical Data...60 Wiring Diagram...63 Service and Maintenance...69 Troubleshooting...71 Exploded View and Part List...80

Nomenclature A5LCY-II-2010 Nomenclature Indoor Unit A 5 CK Y 30 E R Brand A : Acson Refrigerant 5 : R410A Model Name CK CC CM : Ceiling Cassette : Ceiling Concealed : Ceiling Mounted Inverter System Type Y : Y series Capacity Index 28 38 / 40 50 60 / 62 : 24,000 27,000 Btu/h : 34,000 38,000 Btu/h : 42,000 47,000 Btu/h : 47,000 54,000 Btu/h Chassis E : E Series Model Type R : Omitted if cooling only : Heatpump 1

A5LCY-II-2010 Nomenclature Outdoor Unit A 5 LC Y 30 E R Brand A : Acson Refrigerant 5 : R410A Model Name LC : Single Split Condensing Unit Inverter System Type Y : Y series Capacity Index 30 40 50 60 : 24,000 27,000 Btu/h : 34,000 38,000 Btu/h : 42,000 47,000 Btu/h : 47,000 54,000 Btu/h Chassis E : E Series Model Type R : Omitted if cooling only : Heatpump 2

Product Line-Up A5LCY-II-2010 Product Line-Up Indoor Unit A5CKY-E Series Classifi cation Handset PCB Air Purifi cation Marking Others A5CKY Nomenclature APGS02 C_2_01A_M Saranet Filter Negative Ionizer Nano Technology Air Filtration CE Auto Restart HEATPUMP 28ER ACOA X X X 40ER ACOA X X X 50ER ACOA X X X PLCKYER NGS02 X X X A5CCY-C Series Classifi cation Handset PCB Air Purifi cation Marking Others A5CCY Nomenclature Netware 3 C_2_01A_M Saranet Filter Negative Ionizer Nano Technology Air Filtration CE Auto Restart HEATPUMP 28CR ACPA X X X X X 38CR ACPA X X X X X 50CR ACPA X X X X X 60CR ACPA X X X X X 3

A5LCY-II-2010 Product Line-Up Indoor Unit A5CMY-E Series Classifi cation Handset PCB Air Purifi cation Marking Others A5CMY Nomenclature APGS02 C_2_01A_M Saranet Filter Negative Ionizer Nano Technology Air Filtration CE Auto Restart HEATPUMP 28ER ACAA X X X X X 40ER ACAA X X X X X 50ER ACAA X X X X X 62ER ACAA X X X X X 4

Product Line-Up A5LCY-II-2010 Outdoor Unit A5LCY-E Series Classifi cation A5LCY Nomenclature DAIKIN CONTROLLER PCB Refrigerant Control Cap Tube EXV Gold Coated Fin Blue Coated Bare Fin Contactor Safety Devices HP LP DC Inverter Swing Compressor Compressor DC Inverter Scroll Compressor CE Marking Others HEATPUMP 30ER ACDA X X X X X 40ER ACDA X X X X X 50ER ACDA X X X X X 60ER ACDA X X X X X 5

A5LCY-II-2010 Features Features Self Diagnosis The microprocessor provides the possibility to detect and diagnose any fault or malfunction that occurs in the system. The error will be reflected by the blinking of the LED lights and by wireless or wired handset 7-segment display. On top of that, in order to improve serviceability, outdoor unit is also equipped with built in 7-segment display for error code and operating parameters. Technology Incorporate Fuzzy Logic control to achieve more precise temperature control, faster and smoother response. Enhanced design using Electronic Expansion Valve to achieve optimum refrigerant control as compared to capillary tube. Discharge pipe temperature control, high pressure limit control, input current control and heat sink temperature control to improve reliability. On / Off Button on Indoor Unit On/Off button is provided on the unit. It can be used when the remote controller is missing or if its battery has run out. (Note: This button can also be used for forced operation mode) Auto Random Restart Auto random restart function allows the unit to automatic restart as the last setting condition when the power supply is resumed after power failure. However, the compressor will restart randomly if more than one unit is installed and sharing the same phase of power. Wireless Remote Controller The compact LCD transmitter is able to operate the air conditioner unit within the distance of 8 meters. Fan speed can be set at high / medium / low / super low or automatic. Sleep mode auto control will gradually increase or decrease the setting temperature to provide a comfortable surrounding for sleeping. Air fl ow direction can be controlled automatically. Room temperature is controlled by electronic thermostat. The real time timer allows the air conditioner to be switched On and Off automatically based on user settings. Energy Efficiency Using a more effi cient compressor and superior R410A refrigerant, AWM-J series achieves the highest European Energy Rating of A/A. This ensures higher energy savings is accomplished especially during daily usage. A5WM-J series participates in the Eurovent Certifi cation Programme under category of Comfort Air Conditioners rated below 12kW cooling capacity (AC1). The certifi ed data for the certifi ed models are listed in the Eurovent Directory. 6

Application Information A5LCY-II-2010 Application Information Operating Range Ensure the operating temperature is in allowable range. Heatpump Heating Standard point Cooling 18 Outdoor temp. ( CWB) 10 6 STD Outdoor temp. ( CDB) 46 43 35 STD -15-10 15 20 21 27 Indoor temp. ( CDB) 14 19 23 Indoor temp. ( CWB) Caution : The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. 7

A5LCY-II-2010 Application Information Refrigerant Circuit Diagram Model: A5LCY 30ER - A5CKY 28ER / A5CMY 28ER / A5CCY 28CR A5LCY 40ER - A5CKY 40ER / A5CMY 40ER / A5CCY 38CR A5LCY 50ER - A5CKY 50ER / A5CMY 50ER / A5CCY 50CR A5LCY 60ER - A5CCY 60CR / A5CMY 62CR 70034108870 8

Application Information A5LCY-II-2010 Controller GS02 1 2 3 6 7 9 SWING TURBO QUIET MODE SLEEP FAN 4 5 13 12 11 ON TIMER OFF 8 CANCEL CLOCK CANCEL 10 9

A5LCY-II-2010 Application Information Operation Guide 1 Transmission source The source where the signal will be transmitted. 2 Signal transmission indication Blink to confi rm that the last setting has been transmitted to the unit. 3 ON/OFF Button Press once to start the air conditioner unit. Press again to stop the unit. 4 Fan Speed Selection Press the button continuously will toggle the fan speed in the following order: Low p Med p High p Auto Stop pressing when the desired fan speed appears on the display screen. 5 Operation mode Press the MODE button to select the type of operating mode. For cooling only unit, the available modes are: COOL ( ), DRY ( ) and FAN ( ). For heat pump unit, the available modes are: AUTO ( ), COOL ( ), DRY ( ), FAN ( ) and HEAT ( ). The AUTO ( ) mode is unavailable for chilled water system. 6 Automatic air swing Press the SWING button to activate the automatic air swing function. To distribute the air to a specifi c direction, press the SWING button and wait until the louver move to the desired direction and press the button once again. Swing mode selection method (for CK-E model) Press SWING ( ) button for 4 seconds to enter fi eld setting mode. While in fi eld setting mode, it will only show SWING MODE ( ). Press temperature and button to select SWING MODE ( ) rotation from Swing Mode 1 to Swing Mode 3. There are 3 different SWING MODE, which are: Swing mode 1 Swing mode 2 Swing mode 3 SWING MODE will not activate unless SWING is activated. Swing is indicated by the logo: If no mode changes within 4 seconds, unit will operate according to the selected SWING MODE ( ). 7 Turbo function (model dependent) Press for fast cooling or heating operation. Fan speed turn to maximum speed. Press again to deactivate the function. Available under HEAT, COOL and DRY modes only. Any change of fan speed will deactivate this function. The Turbo function ( ) is unavailable for chilled water system and remote control with SWING MODE ( ) function. 8 OFF timer setting Press the TIMER OFF button will activate the off timer function. Set the desired off time by pressing the TIMER OFF button continuously. Press the CANCEL button to cancel the off timer setting. 9 Quiet function (model dependant) Press for quiet operation. Fan speed turn to minimum speed. Press again to deactivate the function. Any change of fan speed will deactivate this function. The Silent function ( ) is unavailable for chiller water system. 10 Clock time setting Press and hold button to set the clock time. 11 ON timer setting Press the TIMER ON button will activate the on timer function. Set the desired on time by pressing the TIMER ON button continuously. If the timer is set to 7.30am, the air conditioner will turn on at 7.30am sharp. Press the CANCEL button to cancel the on timer setting. 12 Sleep mode setting Press the button will activate the sleep mode function. This is an energy saving option. When the unit is operating under cooling mode, the set temperature is increased by 0.5 C after the fi rst half an hour, another 0.5 C after the second half an hour and 1 C after the following 1 hour. When the unit is operating under heating mode, the set +2 C +1 C -1C -2C -3C 0 0.5 1 1.5 2 temperature is decreased by 1 C after the fi rst half an hour, another 1 C after the second half an hour and 1 C after the following 1 hour. This function is available under COOL, HEAT and AUTO mode. 13 Temperature setting To set the desired room temperature, press the * or * button to increase or decrease the set temperature. The temperature setting range is from 16 C to 30 C (Optional setting 20 C to 30 C). Press both buttons and simultaneously to toggle from C to F setting. 10

Application Information A5LCY-II-2010 Controller Netware 3C 1 ON/OFF Button Starting Operation: When the unit is turned off, press the ON/OFF button. The operation LED lights and the unit is turned on. Stopping Operation: When the unit is turned on, press the ON/OFF button. The operation LED is extinguished and control are turned off. 2 SLEEP Button Press SLEEP button to activate the sleep mode or energy saving mode. 3 FAN Button Press FAN button to select AUTO, HIGH, MEDIUM or LOW fan speed. 4 MODE Button Press the MODE button to switch operation from COOL, HEAT, DRY, FAN. Check the display to see in which mode the control is set. 5,6 or Set Temperature Button Press the temperature button and set the temperature of your choice. By pressing the or button once, temperature changes by 1 C [or 1 F]. Temperature can be set within the range 16 C~30 C (61 F~86 F) During fan mode, temperature cannot be set. If pressing and together, the unit of temperature will change from C to F and vice-versa. 7 SWING button Press SWING button to activate the air sweep function. 8 ON TIMER Button Enable/disable the Event 1, 2 and 3 ON TIMER setting mode 9 OFF TIMER Button Enable/disable the Event 1, 2 and 3 OFF TIMER setting mode 10 Timer Active Button These timers will not triggered if the timer is not active. To activate the timers, press the TIMER ACTIVE key unit TIMER ACTIVE appears on LCD. This symbol is to indicate Event 1, Event 2 and/or Event 3 timers are active. Pressing the same steps will deactivate the timers and TIMER ACTIVE symbol will disappear. Another method to cancel the timers setting is changed all the hour setting of the timers to null one by one. When the setting is null, the LCD display --:--, then this respective timer will be disable. 11 CLOCK Button Enable/disable the Real Time Clock (RTC) setting mode 12 DAY Button a) Select the day for RTC or timer setting b) Enable/disable FAN Key lock 13 HOUR Button a) Select the hour for RTC or timer settings b) Set Override function for 1, 2 or 4 hours 14 MINUTE Button a) Select the minute for RTC or timer settings b) Enable/disable key lock 11

A5LCY-II-2010 Application Information Installation Guideline Safety Precautions WARNING CAUTION Installation and maintenance should be performed by qualifi ed persons who are familiar with local code and regulation, and experienced with this type of appliance. All fi eld wiring must be installed in accordance with the national wiring regulation. Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram. The unit must be GROUNDED to prevent possible hazard due to insulation failure. All electrical wiring must not touch the refrigerant piping or any moving parts of the fan motors. Confi rm that the unit has been switched OFF before installing or servicing the unit. Disconnect from the main power supply before servicing the air conditioner unit. DO NOT pull out the power cord when the power is ON. This may cause serious electrical shocks which may result in fire hazards. Keep the indoor and outdoor units, power cable and transmission wiring, at least 1m from TVs and radios, to prevent distorted pictures and static. {Depending on the type and source of the electrical waves, static may be heard even when more than 1m away}. Please take note of the following important points when installing. Do not install the unit where leakage of flammable gas may occur. If gas leaks and accumulates around the unit, it may cause fi re ignition. Ensure that drainage piping is connected properly. If the drainage piping is not connected properly, it may cause water leakage which will dampen the furniture. Do not overcharge the unit. This unit is factory pre-charged. Overcharge will cause over-current or damage to the compressor. Ensure that the unit s panel is closed after service or installation. Unsecured panels will cause the unit to operate noisily. Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from being in contact with these places. Before turning off the power supply, set the remote controller s ON/OFF switch to the OFF position to prevent the nuisance tripping of the unit. If this is not done, the unit s fans will start turning automatically when power resumes, posing a hazard to service personnel or the user. Do not operate any heating apparatus too close to the air conditioner unit. This may cause the plastic panel to melt or deform as a result of the excessive heat. Ensure the color of wires of the outdoor unit and the terminal markings are same to the indoors respectively. IMPORTANT : DO NOT INSTALL OR USE THE AIR CONDITIONER UNIT IN A LAUNDRY ROOM. Do not use joined and twisted wires for incoming power supply. NOTICE Disposal requirements Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste. Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of other parts must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. Please contact the installer or local authority for more information. Batteries must be removed from the remote controller and disposed of separately in accordance with relevant local and national legislation. 12

Application Information A5LCY-II-2010 Installation Diagram Hanger Indoor unit Return duct Supply duct Ceiling Drain piping Wrap the insulated pipe with the finishing tape from bottom to top Thermal insulation Outdoor unit Caution Before installing the unit, ensure that the power supply matches the power requirement of the air conditioner. Installation Indoor Unit Ceiling Cassette Preliminary Site Survey Be sure to read this manual before installing the air-conditioner indoor unit. Electrical supply and installation is to conform to local authority s (e.g. National Electrical Board) codes and regulations. Voltage supply fl uctuation must not exceed +10% of rated voltage. Electricity supply lines must be independent of welding transformers which can cause high supply fl uctuation. Ensure that the location is convenient for wiring, piping and drainage. Do not exert pressure on the resin parts when opening the unit or when moving it after opening. Do not move the unit from packaging while moving, until it reaches the installation site. Use safe material or protection plates when unpacking it or lifting it to avoid damage or scratches to the unit. Check the following accessories are include with your unit: a) Battery (2pcs) f) Screw M4 x 6 (2pcs) b) Screw M6 x 40 (4pcs) g) Cover lock grille (2pcs) c) Washer, fl at OD19 x ID17 x t1.0 (4pcs) h) Operation Manual (1pc) d) Screw M4 x 20 (2pcs) i) Installation Manual (1pc) e) Handset (1pc) j) Drain hose (1pc) 1.0m Min. 3.0m 0.3m Min. 0.5m Min. 0.5m Min. 0.5m Max. Max. Beam Obstacle Floor 13

A5LCY-II-2010 Application Information Ensure a location where: a) Drainage can be done easily. b) Convenient for wiring and piping. c) Which have enough space for installation and service work. d) Where no risk of fl ammable gas leakage. e) When free from any obstacles in path of cool air discharge and warm air return and must allow spreading of air throughout the room (near the center of the room). f) Must be provided clearance for indoor unit from the wall and obstacles as shown in fi gure below. g) The installation place must be strong enough to support a load 4 times the indoor unit weight to avoid amplifying noise and vibration. h) The installation place (hanging ceiling surface) must be assuring levelness and the height in the ceiling is 350mm or more. i) The indoor unit must be away from heat and steam sources (avoid installing it near an entrance). Unit Installation 990.0mm 880.0~990.0mm (Ceiling Opening Site) 622.0mm (Hanging Rod) 990.0mm 880.0~990.0mm (Ceiling Opening Site = 890mm) 770.0mm (Hanging Rod) Measure and mark the position for the hanging rod. Drill the hole for the angle nut on the ceiling and fi x the hanging rod. The installation template is extended according to temperature and humidity. Check on dimensions in use. The dimensions of the installation template are the same as those of the ceiling opening dimensions. Before ceiling laminating work is completed, be sure to fi t the installation template to the indoor unit. NOTE Be sure to discuss the ceiling drilling work with the installers concerned. Piping Direction Unit Hanging Indoor Unit 30.0mm Ceiling Board Confi rm the pitch of the hanging rod is 770mm 622mm sharp. Hold the unit and hang it on the hanging rod with the nut and washer. Adjust the unit height to 30.0mm between the indoor unit bottom surface and the ceiling surface. Confi rm with a level gauge that the unit is installedhorizontally and tighten the nut and bolt to prevent unit falling and vibration. Open the ceiling board along the outer edge of the paper installation template. 14

Application Information A5LCY-II-2010 Drain Piping Work Indoor Unit Pipe Clamp Good Drain Test Feed Water Flexible Drain Hose Bad Main Drain Pipe Drain pipe must be in downward gradient for smooth drainage. Avoid installing the drain pipe in up and down slope to prevent reversed water fl ow. During the drain pipe connection, be careful not to exert extra force on the drain connector at indoor unit. The outside diameter of the drain connection at the fl exible drain hose is 20mm. Be sure to execute heat insulation (polyethylene foam with thickness more than 8.0mm) on the drain piping to avoid the condensed water dripping inside the room. Connect the main drain pipe to the fl exible drain hose. Feed water from fl exible drain hose to check the piping for leakage. When the test is completed, connect the fl exible drain hose to the drain connector on the indoor unit. NOTE This Indoor Unit uses a drain pump for condensed water drainage. Install the unit horizontally to prevent water leakage or condensation around the air outlet. Panel Installation The front panel can only be fi tted in one direction, follow the piping direction. (Follow piping arrow sticker on front panel) Be sure to remove the installation template before installing the front panel. Open Screw Open the air intake grille by pulling back the catchers and removing it together with fi lter from panel. Install the front frame panel onto the indoor unit by 4 screws and tighten it completely to prevent cool air leakage. Connect the LED wire and air swing wire to the indoor unit. The air swing connector must put inside the control box after connected. 15

A5LCY-II-2010 Application Information LED Wire From Front Panel From Unit Control Box Air Swing Wire NOTE Install the front frame panel fi rmly to prevent cool air leakage which will cause condensation and water dripping. Cool Air Indoor Unit Cool Air Air Leak Ceiling Board Air Leak Ceiling Board Panel Panel Good Installation Bad Installation Cover Lock Grille (The moving part protection for user direct touching) Cover lock grill must be installed as the fi gure below. Frame Intake Grille Cover Lock Grille (2pcs) Screw M4 x 6 (2pcs) If the unit need to be service, steps below shall be followed: 1. Confi rm that the unit had been switched off before servicing the unit. 2. Use screwdriver to unlock the screw on the cover lock grille. 3. Remove the cover lock grille and open the intake grille for the service purpose. 4. Install the intake grille and screw the cover lock grille after service and make sure the unit is proper install. 16

Application Information A5LCY-II-2010 Wires Installation Figure 1 Figure 1 and Figure 2 shows the location of cover wire in CKY-E unit. Steps to install power supply wires and wires from outdoor unit. 1. Remove wire cover by removing 2 screws as shown in Figure 3. 2. Wires will go through the hole as shown in fi gure 4 and 5 respectively without crossing the height of the hole. 3. After that, wire cover will be assembled back to close the wire. Figure 2 Figure 3 Figure 4 Figure 5 17

A5LCY-II-2010 Application Information Indoor Unit Ceiling Convertible Preliminary Site Survey Electrical supply and installation is to conform to local authority s (e.g. National Electrical Board) codes and regulations. Voltage supply fl uctuation must not exceed ±10% of rated voltage. Electricity supply lines must be independent of welding transformer which can cause high supply fl uctuations. Ensure that the location is convenient for wiring, piping and drainage. Standard Mounting Ensure that the overhead supports are strong enough to hold the weight of the unit. Position the hanger rods (wall mounting bracket for fl oor standing), and check for its alignment with the unit as shown in Figure A. Also, check that the hangers are secured and the base of the fan coil unit is leveled in both horizontal directions, taking into account the gradient for drainage fl ow as recommended in Figure B. A5CMY28ER Fig A A D C B F E All dimensions are in mm/(in) Dimension A B C D E F A5CMY40ER A5CMY50ER 1320 (52.0) 1538 (60.6) 635 (25.0) 635 (25.0) 255 (10.0) 255 (10.0) 134 (5.3) 134 (5.3) Fig. A 1222 (48.1) 1440 (56.7) 49 (1.9) 49 (1.9) 18

Application Information A5LCY-II-2010 Fig B 10.0mm (0.39") Lower 10.0mm (0.39") Please ensure that the following steps are taken: Check the gradient for drainage fl ow as recommended in Figure B. Provide clearance for easy servicing and optimal air fl ow as shown in Figure C. The indoor unit must be installed such that there is no short circuit of the cool discharge air with the warm return air. Do not install the indoor unit where there is direct sunlight shining on the unit. The location should be suitable for piping and drainage installation. The unit must be a large distance away from the door. Fig C Min. 10.0mm (0.39") Min. 300.0mm (11.81") Max. 250mm (9.84") 500mm (19.60") Utensils, Furnitures Or Built- In Architectural Features Must Not Protrude More Than 250.0mm Min. Ceiling Type Min. 400.0mm (15.75") Min. 1.0m (39.37") Floor Standing Type 19

A5LCY-II-2010 Application Information UNDER CEILING INSTALLATION Install Suspension Bolts 1. Install the suspension bolts so that it can support the indoor unit. 2. Adjust distance to ceiling before installation. 3. Refer to dimension given to install the unit. Install Indoor Units 1. Insert the suspension bolts into the fi ttings of the hanger bracket. 2. Set the nuts and washer on both side of the metal fi ttings. 3. Secure it with nuts. Installation Ceiling Type Fig D 10mm 300mm(Min.) 300mm(Min.) 621mm 10mm Ceiling 10mm Installation Floor Type Fig E Wall Wall 20

Application Information A5LCY-II-2010 Installation - Ceiling Exposed Type Step 1 Remove air intake grille, side panel and hanger bracket from the unit. Please refer to Fig F. Fig F Hanger Bracket Side Panel Step 2 Position the hanger rod as shown in Fig G and install the hanger bracket. Fig G Step 3 Hang up the unit and tighten the bolts after installation of piping and drain pipe. Lastly install the intake grille and side panel to the correct position. Fig H 21

A5LCY-II-2010 Application Information Fig I Piping and Drain Hose Installation Fig J Steps to open intake grille 1. Unlock the screw attached to block lock grille with screwdriver. 2. Remove block lock grille and unlock grille lock. 3. Please refer to Fig K for reference. Fig K Close Open Block Lock Grille Screw (M4) 22

Application Information A5LCY-II-2010 Indoor Unit Ceiling Concealed The indoor unit must be installed such that there is no short circuit of the cool discharge. Respect the installation clearance. Do not put the indoor unit where there is direct sunlight on unit. The location is suitable for piping and drainage and it must have a large distance between a door and unit. A5CCY A mm (inch) L mm (inch) 28CR 959 (37.8) 339 (13.3) 38CR 1264 (49.8) 401 (15.8) 50CR 1326 (52.2) 266 (10.5) 60CR 1526 (60.1) 266 (10.5) Provide clearance for servicing ease and optimal air fl ow as shown in the diagram. Ceiling Concealed Mounting Use the hanger supplied with the unit. Make sure that the ceiling is suffi ciently strong to withstand the weight. Insulation material (field supply) See Detail A 10mm (0.39") 300mm* or more 300mm or more Air outlet side Air inlet side Aluminium tape (field supply) Field supply Aluminium tape (field supply) 10mm (0.39") * Can be smaller than 300m if ceiling is removable Washer for hanger bracket (attached) Tighten Detail A Center distance of axle (see drawing below) A L 23

A5LCY-II-2010 Application Information Ceiling Concealed Drain Piping Work mm (0.39") 10 Insulate securely SlantBottom of the unit Drain trap 100 100 o r more or mor e Do not leave in water Unit : mm The drain pipe must be installed as shown in the diagram (see diagram above) to avoid damage caused by leaks and condensation. For the best result, keep the piping as short as possible. Slant the piping at an angle to improve the fl ow. Ensure the drain pipe is securely insulated. It is necessary to provide a drain trap in the drain outlet to relieve pressure that exists within the unit compared to the outside atmospheric pressure when the unit is operating. The drain trap is to avoid possibility of splashes or an odor. Keep pipes as straight as possible for easy cleaning and to prevent the accumulation of dirt and debris. Conduct a water drainage test after the installation is completed. Make sure that the drainage fl ow is smooth. In humid environments, use an extra drain pan to cover the entire area of the indoor unit. 24

Application Information A5LCY-II-2010 Installation of Outdoor Unit A5LCY30E/ER Wall facing one side More than 50 More than 500 Side View Wall facing more than 1 side of obstacle More than 100 More than 50 More than 150 More than 100 Top View More than 500 Unit: mm A5LCY40/50/60E/ER Wall facing one side More than 100 More than 500 Side View Wall facing more than 1 side of obstacle More than 100 More than 100 More than 100 More than 100 More than 500 Top View Unit: mm 25

A5LCY-II-2010 Application Information Electrical Wiring Connection IMPORTANT : * The fi gures shown in the table are for information purpose only. They should be checked and selected to comply with the local/national codes of regulations. This is also subject to the type of installation and conductors used. ** The appropriate voltage range should be checked with label data on the unit. Indoor Unit Terminal Block 1 2 3 Outdoor Unit Terminal Block 1 2 3 L N Power Supply Cable! There must be a double pole switch with a minimum 3 mm contact gap and fuse/circuit breaker as recommended in the fixed installation circuit. Model 30 40 50 60 Voltage range 220V 240V /1Ph /50Hz + Power supply cable size (nominal cross section in mm 2 ) Number of wire Interconnection cable size (nominal cross section in mm 2 ) Number of wire Recommended time delay fuse (A) 20 32 32 32 All wires must be fi rmly connected. All wires must not touch the refrigerant piping, compressor or any moving parts of the fan motor. The connecting wires between the indoor unit and the outdoor unit must be clamped on the wire clamps. The power supply cord must be equivalent to H07RN-F (245 IEC65, 245 IEC66) which is the minimum requirement. Refrigerant Piping Piping Length and Elevation If the pipe is too long, both the capacity and reliability of the unit will drop. As the number of bends increases, resistance to the fl ow of refrigerant system increases, thus lowering cooling capacity. As a result, the compressor may become defective. Always choose the shortest path and follow the recommendations as tabulated below: Indoor A5CKY28ER A5CMY28ER A5CCY28CR 4 3 1.5 4 A5CKY40ER A5CMY40ER A5CCY38CR 6 3 1.5 4 A5CKY50ER A5CMY50ER A5CCY50CR 6 3 1.5 4 6 3 1.5 4 A5CMY62CR A5CCY60CR Outdoor A5LCY30E/ER A5LCY40E/ER A5LCY50E/ER A5LCY60E/ER Max. allowable length, m 50 75 75 75 Max. allowable height, m 30 30 30 30 Liquid pipe, mm OD9.5 OD9.5 OD9.5 OD9.5 Gas pipe size, mm OD15.9 OD15.9 OD15.9 OD15.9 Additional charge of refrigerant, g/m (for piping length above 30m) 50 50 50 50 * Be sure to add the proper amount of additional refrigerant. Failure to do so may result in reduced performance Remark: The refrigerant pre-charged in the outdoor unit is for piping length up to 7.6m/25ft. 26

Application Information A5LCY-II-2010 Piping Works Do not use contaminated or damaged copper tubing. Do not remove plastic, rubber plugs and brass nuts from the valves, fi ttings, tubings and coils until you are ready to connect suction or liquid line into valves or fi ttings. If any brazing work is required, ensure that the nitrogen gas is passed through coil and joints while the brazing work is being done. This will eliminate soot formation on the inside walls of the copper tubings. Cut the connection pipe with a pipe cutter. 1/4t Cutting copper tube Remove burrs from cut edges of the pipes with remover. Hold the end of the pipe downwards to prevent metal chips from entering the pipe. Remove burr Insert the fl are nuts, mounted on the connection parts of both the indoor unit and outdoor unit onto the copper pipes. Flare the pipe with extra length above the fl aring tool as shown in the table. The fl ared edge must be even and not cracked or scratched. Ø Tube, A (mm) Inch mm Imperial Die Rigid Die 1/4 6.35 1.3 0.7 3/8 9.52 1.6 1.0 1/2 12.70 1.9 1.3 5/8 15.88 2.2 1.7 3/4 19.05 2.5 2.0 Copper tube Swaging block 27

A5LCY-II-2010 Application Information Piping Connection to the Units Align the center of the piping and tighten the fl are nut suffi ciently with fi ngers. Finally tighten the fl are nut with torque wrench unit the wrench clicks. When tightening the fl are nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench. The refrigerant pipe connection are insulated by polyurethane (ARMAFLEX type or similiar) Ø Tube, D A (mm) Inch mm Imperial Rigid 1/4 6.35 1.3 0.7 3/8 9.52 1.6 1.0 1/2 12.70 1.9 1.3 5/8 15.88 2.2 1.7 3/4 19.05 2.5 2.0 Flare joint Indoor piping Flared tube Flare nut Pipe Size, mm (in) Torque (Nm) 6.35 (1/4) 18 9.53 (3/8) 42 12.7 (1/2) 55 15.88 (5/8) 65 19.05 (3/4) 78 Vacuuming and Charging Spanar Torque wrench Purging The Piping And The Indoor Unit Except for the outdoor unit which is pre-charged with refrigerant, the indoor unit and the refrigerant connection pipes must be air-purged because the air containing moisture that remains in the refrigerant cycle may cause malfunction of the compressor. Remove the caps from the valve and the service port. Connect the center of the charging gauge to the vacuum pump. Connect the charging gauge to the service port of the 3-way valve. Start the vacuum pump. Evacuate for approximately 30 minutes. The evacuation time varies with different vacuum pump capacity. Confi rm that the charging gauge needle has moved towards -760mmHg. Allen key Flare nut Refrigerant piping Indoor Unit Liquid side Discharge Outdoor Unit valve Close Gas side Service port Outdoor unit 3 ways valve Open Vacuum pump Low Hi Close Suction valve Close Caution If the gauge needle does not move to -760mmHg, be sure to check for gas leaks (using the refrigerant detector) at fl are type connection of the indoor and outdoor unit and repair the leak before proceeding to the next step. Close the valve of the charging gauge and stop the vacuum pump. On the outdoor unit, open the suction valve (3 way) and liquid valve (2 way) (in anti-clockwise direction) with 4mm key for hexagon sacked screw. 28

Application Information A5LCY-II-2010 Charge Operation This operation must be done by using a gas cylinder and a precise weighing machine. The additional charge is topped-up into the outdoor unit using the suction valve via the service port. Remove the service port cap. Connect the low pressure side of the charging gauge to the suction service port center of the cylinder tank and close the high pressure side of the gauge. Purge the air from the service hose. Start the air conditioner unit. Open the gas cylinder and low pressure charging valve. When the required refrigerant quantity is pumped into the unit, close the low pressure side and the gas cylinder valve. Disconnect the service hose from service port. Put back the service port cap. Indoor Unit Liquid side Outdoor Unit Discharge valve Open Gas side Check valve Low Hi Close Suction valve Open Special Precautions when Dealing with R410A Unit R410A is a new HFC refrigerant which does not damage the ozone layer. The working pressure of this new refrigerant is 1.6 times higher than conventional refrigerant (R22), thus proper installation / servicing is essential. Never use refrigerant other than R410A in an air conditioner which designed to operate with R410A. POE oil is used as lubricant for R410A compressor, which is different from the mineral oil used for R22 compressor.during installation or servicing, extra precaution must be taken not to expose the R410A system too long to moist air. Residual POE oil in the piping and components can absorb moisture from the air. To prevent mischarging, the diameter of the service port on the fl are valve is different from that of R22. Use tools and materials exclusively for refrigerant R410A. Tools exclusively for R410A are manifold valve, charging hose, pressure gauge, gas leak detector, fl are tools, torque wrench, vacuum pump and refrigerant cylinder. As an R410A air conditioner incurs higher pressure than R22 units, it is essential to choose the copper pipes correctly. Never use copper pipes thinner than 0.8mm even though they are available in the market. If the refrigerant gas leakage occurs during installation / servicing, be sure to ventilate fully. If the refrigerant gas comes into contact with fi re, a poisonous gas may occur. When installing or removing an air conditioner, do not allow air or moisture to remain in the refrigerant cycle. 29

A5LCY-II-2010 Sound Data Sound Data A5CKY-ER NC Curves Model A5CKY28ER A5CKY40ER A5CKY50ER Speed 1/1 Octave A-Weighted Sound Pressure (dba), ref 20μPa Overall 125 Hz 250 Hz 500 Hz 1k Hz 2k Hz 4k Hz 8k Hz A (dba) Noise Criteria High 45 43 42 35 29 22 11 41 37 Medium 40 41 39 30 24 15 7 38 34 Low 38 38 35 26 19 9 5 35 30 Super Low 35 35 33 23 14 5 4 32 28 High 48 45 44 38 30 28 15 44 39 Medium 49 42 41 34 25 21 8 41 36 Low 48 39 38 31 21 13 6 38 33 Super Low 45 35 36 26 15 5 5 35 31 High 50 48 46 42 33 32 20 47 41 Medium 52 45 43 38 29 27 13 44 38 Low 53 43 42 37 27 24 10 43 37 Super Low 51 41 39 32 23 16 6 39 34 Model Measuring location A5CKY28ER 1.4m Standard : JIS C 9612 Microphone A5CKY40ER A5CKY50ER 1.5m Standard : JIS B 8615 Microphone 30

Sound Data A5LCY-II-2010 A5CCY-CR Sound Power Model Ext. Static (mmaq) Speed 1/1 Octave Sound Power Level (db, reference 1pW) Overall 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz A (dba) A5CCY28CR 10 Super High 62 65 61 63 60 57 56 67 8 High 59 61 58 61 57 54 52 64 7 Medium 56 57 55 57 54 50 48 61 6 Low 52 53 51 53 50 45 41 57 A5CCY38CR 14 Super High 74 75 74 75 72 70 69 80 12 High 70 70 71 72 68 66 64 76 11 Medium 67 67 68 70 65 62 60 73 9 Low 65 64 65 66 61 58 56 70 A5CCY50CR 18 Super High 70 71 73 74 72 69 67 78 16 High 67 69 71 72 69 66 64 76 14 Medium 66 66 69 69 66 63 61 73 11 Low 63 64 66 67 62 60 57 70 A5CCY60CR 18 Super High 70 71 73 75 73 70 68 79 16 High 69 70 72 74 71 69 68 78 14 Medium 69 68 70 71 67 65 63 75 10 Low 64 65 67 67 63 61 59 71 Duct Discharge Sound Power Level: Test with 5ft length discharge duct, terminated fl ush with internal wall of reverberation room. 31

A5LCY-II-2010 Sound Data Sound Pressure Model A5CCY28CR A5CCY38CR A5CCY50CR A5CCY60CR Speed 1/1 Octave A-Weighted Sound Pressure (dba), ref 20μPa Overall 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz A (dba) Noise Criteria Super High 48 45 42 38 34 29 26 44 37 High 45 42 39 35 31 26 22 41 34 Medium 42 38 37 32 28 22 17 38 32 Low 36 33 33 27 23 16 11 34 27 Super High 56 57 53 50 46 41 36 55 49 High 54 51 48 46 41 36 31 51 45 Medium 51 48 46 45 37 32 26 48 44 Low 47 45 44 41 34 28 22 45 40 Super High 56 50 50 49 44 38 33 53 48 High 54 49 49 48 43 37 32 52 47 Medium 53 47 46 47 40 35 29 50 46 Low 51 45 44 44 36 32 26 47 43 Super High 57 50 51 51 46 39 35 55 50 High 55 49 49 50 44 37 33 53 49 Medium 53 46 47 47 39 34 28 50 46 Low 51 43 44 43 35 30 24 47 42 Microphone position: 1.4m below the centre of the unit. (GB Standard - GB/D17758) Tested with 2m length duct at the air discharge outlet and air return inlet. Measuring Location: 2m length test duct Test Unit 2m length test duct Air 1.4m Microphone 32

Sound Data A5LCY-II-2010 A5CKY28ER NC Curve 80 70 NC70 Sound pressure level (db, ref 20μPa) 60 50 40 30 Super High Fan High Fan NC65 NC60 NC55 NC50 NC45 NC40 NC35 NC30 20 Medium Fan NC25 Low Fan NC20 10 63 125 250 500 1000 2000 4000 8000 Octave-band frequency (Hz) A5CKY40ER NC Curve 80 70 NC70 Sound pressure level (db, ref 20μPa) 60 50 40 30 Super High Fan High Fan NC65 NC60 NC55 NC50 NC45 NC40 NC35 NC30 20 Medium Fan NC25 Low Fan NC20 10 63 125 250 500 1000 2000 4000 8000 Octave-band frequency (Hz) 33

A5LCY-II-2010 Sound Data A5CKY50ER NC Curve 80 70 NC70 Sound pressure level (db, ref 20μPa) 60 50 40 30 Super High Fan High Fan NC65 NC60 NC55 NC50 NC45 NC40 NC35 Medium Fan NC30 20 Low Fan NC25 NC20 10 63 125 250 500 1000 2000 4000 8000 Octave-band frequency (Hz) 34

Sound Data A5LCY-II-2010 70 A5CCY28CR NC Curves 60 Sound Pressure Level (db, ref 20μPa) 50 40 30 20 LO SH HI FAN ME NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band Frequency (Hz) Measured in anechoic room at 1.4m below the centre of the unit Tested with 2m length duct at the air discharge outlet and air return inlet 70 A5CCY38CR NC Curve 60 Sound pressure level (db, ref 20μPa) 50 40 30 20 LO SH FAN HI FAN ME FAN NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band frequency (Hz) Measured in anechoic room at 1.4m below the centre of the unit Tested with 2m length duct at the air discharge outlet and air return inlet 35

A5LCY-II-2010 Sound Data 70 A5CCY50CR NC Curve 60 Sound pressure level (db, ref 20μPa) 50 40 30 20 ME FAN LO SH HI FAN NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band frequency (Hz) Measured in anechoic room at 1.4m below the centre of the unit Tested with 2m length duct at the air discharge outlet and air return inlet 70 A5CCY60CR NC Curve 60 Sound pressure level (db, ref 20μPa) 50 40 30 20 SH HI FAN LO ME FAN NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band frequency (Hz) Measured in anechoic room at 1.4m below the centre of the unit Tested with 2m length duct at the air discharge outlet and air return inlet 36

Sound Data A5LCY-II-2010 A5CCY28CR BLOWER PERFORMANCE CURVE 14 12 M H SH External Static Pressure, (mm w.g.) 10 8 6 4 L 2 0 200 400 600 800 1000 1200 Flowrate, (CFM) 37

A5LCY-II-2010 Sound Data A5CCY38CR BLOWER PERFORMANCE CURVE 15 M H SH L Total Static Pressure, (mm w.g.) 10 5 0 600 800 1000 1200 1400 1600 Flowrate, (CFM) 38

Sound Data A5LCY-II-2010 A5CCY50CR BLOWER PERFORMANCE CURVE 25 20 H SH Total Static Pressure, (mm w.g.) 15 10 L M 5 0 1000 1200 1400 1600 1800 Flowrate, (CFM) 39

A5LCY-II-2010 Sound Data A5CCY60CR BLOWER PERFORMANCE CURVE 25 20 M H SH Total Static Pressure, (mm w.g.) 15 10 L 5 0 1000 1200 1400 1600 1800 2000 2200 Flowrate, (CFM) 40

Engineering & Physical Data A5LCY-II-2010 Engineering & Physical Data General Data - Ceiling Cassette Heat Pump MODEL INDOOR UNIT A5CKY 28ER A5CKY 40ER OUTDOOR UNIT A5LCY 30ER A5LCY 40ER NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY Btu/h 25249 34802 W 7400 10200 Btu/h 28320 40603 W 8300 11900 NOMINAL TOTAL INPUT POWER (COOLING) W 2236 3178 NOMINAL TOTAL INPUT POWER (HEATING) W 2299 3296 NOMINAL RUNNING CURRENT (COOLING) A 9.27 13.20 NOMINAL RUNNING CURRENT (HEATING) A 9.70 13.70 POWER SOURCE V/Ph/Hz 220-240 / 1 / 50 221-240 / 1 / 50 EER W/W 3.31 3.21 COP W/W 3.61 3.61 REFRIGERANT TYPE R410A R410A REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR EXV OUTDOOR EXV CONTROL AIR FLOW AIR DISCHARGE OPERATION AUTOMATIC LOUVER (UP & DOWN) WIRELESS OR WIRED MICRO- COMPUTER REMOTE CONTROL AUTOMATIC LOUVER (UP & DOWN) WIRELESS OR WIRED MICRO- COMPUTER REMOTE CONTROL HIGH l/s / CFM 406 / 860 486 / 1030 MEDIUM l/s / CFM 342 / 725 406 / 860 LOW l/s / CFM 293 / 620 349 / 740 INDOOR UNIT EXTERNAL STATIC PRESSURE (H/M/L) Pa / in.wg. 0 0 SOUND PRESSURE LEVEL (H/M/L) dba 41 / 38 / 35 44 / 41 / 38 UUNIT DIMENSION ( ) - WITH PANEL HEIGHT mm/in 265 (340) / 10.43 (13.39) 300 (375) / 11.81 (14.76) WIDTH mm/in 820 (990) / 32.3 (38.98) 820 (990) / 32.3 (38.98) DEPTH mm/in 820 (990) / 32.3 (38.98) 820 (990) / 32.3 (38.98) PACKING DIMENSION ( ) - PANEL HEIGHT mm/in 300 (110) / 11.8 (4.33) 335 (110) / 13.19 (4.3) WIDTH mm/in 916 (1030) / 36.1 (40.6) 916 (1030) / 36.1 (40.6) DEPTH mm/in 916 (1030) / 36.1 (40.6) 916 (1030) / 36.1 (40.6) UNIT WEIGHT kg/lb 35 / 16 43 / 19.5 CONDENSATE DRAIN SIZE mm/in 19.1 / 3/4 19.1 / 3/4 AIR FLOW l/s / CFM 801 / 1699 1706 / 3616 SOUND PRESSURE LEVEL dba 48 50 HEIGHT mm/in 770 / 30.3 1340 / 52.8 UNIT DIMENSION WIDTH mm/in 900 / 35.4 900 / 35.4 OUTDOOR UNIT PACKING DIMENSION DEPTH mm/in 320 / 12.6 320 / 12.6 HEIGHT mm/in 900 / 35.4 1524 / 60.0 WIDTH mm/in 980 / 38.6 980 / 38.6 DEPTH mm/in 420 / 16.5 420 / 16.5 UNIT WEIGHT kg/lb 67 / 147.7 109 / 240.3 TYPE FLARE VALVE FLARE VALVE PIPE CONNECTION SIZE LIQUID mm/in 9.52 / 3/8 9.52 / 3/8 GAS mm/in 15.87 / 5/8 15.87 / 5/8 REFRIGERANT CHARGE kg/lb 2.75 / 6.05 3.95 / 8.69 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27 C DB / 19 C WB INDOOR AND 35 C DB / 24 C WB OUTDOOR b) HEATING - 20 C DB INDOOR AND 7 C DB / 6 C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD (A5CKY28ER) AND JIS B 8615 STANDARD (A5CKY40ER). POSITION OF THE MEASUREMENT POINT IS 1.4m (A5CKY28ER) AND 1.5m (A5CKY40ER) BELOW FASCIA. 41

A5LCY-II-2010 Engineering & Physical Data General Data - Ceiling Cassette Heat Pump MODEL INDOOR UNIT OUTDOOR UNIT A5CKY 50ER A5LCY 50ER NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY Btu/h 44356 W 13000 Btu/h 48109 W 14100 NOMINAL TOTAL INPUT POWER (COOLING) W 4025 NOMINAL TOTAL INPUT POWER (HEATING) W 3906 NOMINAL RUNNING CURRENT (COOLING) A 18.90 NOMINAL RUNNING CURRENT (HEATING) A 16.30 POWER SOURCE V/Ph/Hz 221-240 / 1 / 50 EER W/W 3.23 COP W/W 3.61 REFRIGERANT TYPE R410A REFRIGERANT CONTROL (EXPANSION DEVICE) CONTROL AIR FLOW AIR DISCHARGE OPERATION OUTDOOR EXV AUTOMATIC LOUVER (UP & DOWN) WIRELESS OR WIRED MICRO- COMPUTER REMOTE CONTROL HIGH l/s / CFM 566 / 1200 MEDIUM l/s / CFM 486 / 1030 LOW l/s / CFM 439 / 930 INDOOR UNIT EXTERNAL STATIC PRESSURE (H/M/L) Pa / in.wg. 0 SOUND PRESSURE LEVEL (H/M/L) dba 47 / 44 / 43 UUNIT DIMENSION ( ) - WITH PANEL PACKING DIMENSION ( ) - PANEL HEIGHT mm/in 300 (375) / 11.81 (14.76) WIDTH mm/in 820 (990) / 32.3 (38.98) DEPTH mm/in 820 (990) / 32.3 (38.98) HEIGHT mm/in 335 (110) / 13.19 (4.3) WIDTH mm/in 916 (1030) / 36.1 (40.6) DEPTH mm/in 916 (1030) / 36.1 (40.6) UNIT WEIGHT kg/lb 45 / 20.4 CONDENSATE DRAIN SIZE mm/in 19.1 / 3/5 AIR FLOW l/s / CFM 1820 / 3858 SOUND PRESSURE LEVEL dba 51 HEIGHT mm/in 1340 / 52.8 UNIT DIMENSION WIDTH mm/in 900 / 35.4 OUTDOOR UNIT PACKING DIMENSION DEPTH mm/in 320 / 12.6 HEIGHT mm/in 1524 / 60.0 WIDTH mm/in 980 / 38.6 DEPTH mm/in 420 / 16.5 UNIT WEIGHT kg/lb 109 / 240.3 TYPE FLARE VALVE PIPE CONNECTION LIQUID mm/in 9.52 / 3/8 SIZE GAS mm/in 15.87 / 5/8 REFRIGERANT CHARGE kg/lb 3.95 / 8.69 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27 C DB / 19 C WB INDOOR AND 35 C DB / 24 C WB OUTDOOR b) HEATING - 20 C DB INDOOR AND 7 C DB / 6 C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA. 42

Engineering & Physical Data A5LCY-II-2010 General Data - Ceiling Convertible Heat Pump MODEL INDOOR UNIT A5CMY 28ER A5CMY 40ER OUTDOOR UNIT A5LCY 30ER A5LCY 40ER NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY Btu/h 25931 33096 W 7600 9700 Btu/h 27637 38897 W 8100 11400 NOMINAL TOTAL INPUT POWER (COOLING) W 2508 3201 NOMINAL TOTAL INPUT POWER (HEATING) W 2656 3508 NOMINAL RUNNING CURRENT (COOLING) A 11.10 15.10 NOMINAL RUNNING CURRENT (HEATING) A 11.70 13.60 POWER SOURCE V/Ph/Hz 220-240 / 1 / 50 221-240 / 1 / 50 EER W/W 3.03 3.03 COP W/W 3.05 3.25 REFRIGERANT TYPE R410A R410A REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR EXV OUTDOOR EXV CONTROL AIR FLOW AIR DISCHARGE OPERATION AUTOMATIC LOUVER (UP & DOWN) WIRELESS OR WIRED MICRO- COMPUTER REMOTE CONTROL AUTOMATIC LOUVER (UP & DOWN) WIRELESS OR WIRED MICRO- COMPUTER REMOTE CONTROL HIGH l/s / CFM 293 / 620 520 / 1100 MEDIUM l/s / CFM 269 / 570 464 / 983 LOW l/s / CFM 245 / 520 414 / 877 INDOOR UNIT EXTERNAL STATIC PRESSURE (H/M/L) Pa / in.wg. 0 0 SOUND PRESSURE LEVEL (H/M/L) dba 56 / 51 / 44 52 / 47 / 46 HEIGHT mm/in 218 / 8.6 259 / 10.2 UNIT DIMENSION WIDTH mm/in 1080 / 42.5 1538 / 60.6 DEPTH mm/in 630 / 24.8 635 / 25.0 HEIGHT mm/in 297 / 11.7 335 / 13.2 PACKING DIMENSION WIDTH mm/in 1197 / 47.1 910 / 35.8 DEPTH mm/in 740 / 29.1 910 / 35.8 UNIT WEIGHT kg/lb 27 / 12.25 43 / 19.5 CONDENSATE DRAIN SIZE mm/in 19.1 / 3/4 19.1 / 3/4 AIR FLOW l/s / CFM 801 / 1699 1706 / 3616 SOUND PRESSURE LEVEL dba 48 50 HEIGHT mm/in 770 / 30.3 1340 / 52.8 UNIT DIMENSION WIDTH mm/in 900 / 35.4 900 / 35.4 OUTDOOR UNIT PACKING DIMENSION DEPTH mm/in 320 / 12.6 320 / 12.6 HEIGHT mm/in 900 / 35.4 1524 / 60 WIDTH mm/in 980 / 38.6 980 / 38.6 DEPTH mm/in 420 / 16.5 420 / 16.5 UNIT WEIGHT kg/lb 67 / 147.7 109 / 240.3 TYPE FLARE VALVE FLARE VALVE PIPE CONNECTION SIZE LIQUID mm/in 9.52 / 3/8 9.52 / 3/8 GAS mm/in 15.87 / 5/8 15.87 / 5/8 REFRIGERANT CHARGE kg/lb 2.75 / 6.05 3.95 / 8.69 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27 C DB / 19 C WB INDOOR AND 35 C DB / 24 C WB OUTDOOR b) HEATING - 20 C DB INDOOR AND 7 C DB / 6 C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 43

A5LCY-II-2010 Engineering & Physical Data General Data - Ceiling Convertible Heat Pump MODEL INDOOR UNIT A5CMY 50ER A5CMY 62CR OUTDOOR UNIT A5LCY 50ER A5LCY 60ER NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY Btu/h 42991 46062 W 12600 13500 Btu/h 52545 56639 W 15400 16600 NOMINAL TOTAL INPUT POWER (COOLING) W 4437 5133 NOMINAL TOTAL INPUT POWER (HEATING) W 4798 4368 NOMINAL RUNNING CURRENT (COOLING) A 20.90 24.20 NOMINAL RUNNING CURRENT (HEATING) A 19.10 20.50 POWER SOURCE V/Ph/Hz 221-240 / 1 / 50 222-240 / 1 / 50 EER W/W 2.84 2.63 COP W/W 3.21 3.80 REFRIGERANT TYPE R410A R410A REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR EXV OUTDOOR EXV CONTROL AIR FLOW AIR DISCHARGE OPERATION AUTOMATIC LOUVER (UP & DOWN) WIRELESS OR WIRED MICRO- COMPUTER REMOTE CONTROL AUTOMATIC LOUVER (UP & DOWN) WIRELESS OR WIRED MICRO- COMPUTER REMOTE CONTROL HIGH l/s / CFM 573 / 1215 731 / 1550 MEDIUM l/s / CFM 511 / 1082 651 / 1320 LOW l/s / CFM 453 / 959 472 / 1000 INDOOR UNIT EXTERNAL STATIC PRESSURE (H/M/L) Pa / in.wg. 0 0 SOUND PRESSURE LEVEL (H/M/L) dba 51.5 / 50.1 / 48.8 56 / 53 / 46 HEIGHT mm/in 260 / 10.25 285 / 11.2 UNIT DIMENSION WIDTH mm/in 1786 / 70.3 1903 / 75 DEPTH mm/in 634 / 25 680 / 26.8 HEIGHT mm/in 330 / 13 351 / 13.8 PACKING DIMENSION WIDTH mm/in 1892 / 74.5 2016 / 79.3 DEPTH mm/in 724 / 28.5 788 / 31 UNIT WEIGHT kg/lb 65 / 29.5 70 / 31.8 CONDENSATE DRAIN SIZE mm/in 19.1 / 3/5 19.1 / 3/5 AIR FLOW l/s / CFM 1820 / 3858 1775 / 3761 SOUND PRESSURE LEVEL dba 51 51 HEIGHT mm/in 1340 / 52.8 1340 / 52.8 UNIT DIMENSION WIDTH mm/in 900 / 35.4 900 / 35.4 OUTDOOR UNIT PACKING DIMENSION DEPTH mm/in 320 / 12.6 320 / 12.6 HEIGHT mm/in 1524 / 60 1524 / 60 WIDTH mm/in 980 / 38.6 980 / 38.6 DEPTH mm/in 420 / 16.5 420 / 16.5 UNIT WEIGHT kg/lb 109 / 240.3 109 / 240.3 TYPE FLARE VALVE FLARE VALVE PIPE CONNECTION SIZE LIQUID mm/in 9.52 / 3/8 9.52 / 3/8 GAS mm/in 15.87 / 5/8 15.87 / 5/8 REFRIGERANT CHARGE kg/lb 3.95 / 8.69 3.95 / 8.69 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27 C DB / 19 C WB INDOOR AND 35 C DB / 24 C WB OUTDOOR b) HEATING - 20 C DB INDOOR AND 7 C DB / 6 C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 44