Condensate Recovery and Return System SDR A

Similar documents
Condensate Recovery and Return System SDR A

Open System Condensate receiver tank of cylindrical. design type SDR A with highpressure

Product overview. the optimum components for every application

GESTRA Special Equipment and Vessels for Heat Recovery. For every application the optimally coordinated system

GESTRA. Product Overview. The optimum components for every application

GESTRA. Product Overview. The optimum components for every application

Silhouette. Feedwater Heater. Boiler Feedwater

BuildingName The Description of the Project P DOCUMENTS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

FEEDWATER TANK WITH DEAERATOR DATASHEET. Capacity 1000 to lt Operating Pressure 0,5 bar

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

SECTION HEATING BOILER FEEDWATER EQUIPMENT

GESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes

MFP14 Automatic pumps. for condensate and other industrial fluids

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

MFP14 Automatic pumps for condensate and other industrial fluids

SECTION STEAM CONDENSATE PUMPS

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

2007 ASME Boiler & Pressure Vessel Code 2007 Edition July 1, 2007

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

BOILER HOUSE PRODUCTS GMS

.005 ATMOSPHERIC DEAERATOR

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Installation, Operation, and Maintenance. For. Stickle Series AIV Spray-Tray Type Deaerating Feedwater Heaters. Introduction

DEAERATORS .005 ATMOSPHERIC DEAERATOR

CRU-S Series Stainless Steel Condensate Recovery Unit

Basic information about quick steam generators/boilers System GEKA Heat Technology Gottfried Kneifel

ESTEEM AUTOCLAVE SLIDING SINGLE DOOR:-

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

SECTION STEAM CONDENSATE PUMPS

Raffaello From serial number Group

Domestic Pump Condensate Transfer Equipment

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Flash Condensing De-aerator Heads Installation and Maintenance Instructions

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

Condensate Return Feedwater Systems For Low and High Pressure Steam Boilers

Information on selection of an economizer, and resulting payback due to changes in inlet water temperature.

.03 ATMOSPHERIC DEAERATOR

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

Installation and Operating Service Manual

SECTION Boiler Controls & Waste Heat Recovery

PIONEERS IN AIR VACUUMS

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

HEAT EXCHANGE INSTITUTE, INC.

C44A/C44AW DISHWASHER

.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems.

Stainless Steel Condensate Return Units

CRU 200 and 500 Series Condensate Recovery Units

The Liquid Manufacturing Plants are ideal tools for the pharmaceutical industry and food industry for the production of Oral Liquids.

Vapour Jet Refrigerator / Heat Pump R853

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

Model: 1100 Float-Controlled Condensate Trap, PN 25

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Deaerator. Specifications

True Auto-Purge System

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

SECTION BOILER PLANT MECHANICAL EQUIPMENT

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Centrifugal Blowdown Separators and Tanks

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source

Packaged Steam Fired Water Heater

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

OPERATING AND MAINTENANCE MANUAL FOR VERTICAL IMMERSION HEATED STEAM BOILERS. Technical Control Systems Limited MODELS "VIHS"

TITLE: SPECIFICATION NO. PE-MSE-VD-ACC VOLUME:

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

SECTION STEAM CONDENSATE PUMPS

Steam Systems 101. Understanding Your Energy Systems Better. May 5, 2016

Documento Descargado desde:

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

LGB Gas fired boiler

TMCI Padovan Evaporators

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

: 1.5kw/AC220V.50Hz (AC110V 60Hz) : 340*200*30mm (3piece) 400*200*30mm (3 piece)

STEAM VALVE SUPPLY & SYSTEM DESIGN

Level Electrode NRG NRG Original Installation Instructions English

SPECIFICITIES OF SUPERVISION OF OVERPRESSURIZED EQUIPMENT

Global-Tek (Singapore) Pte Ltd

INSTRUCTION MANUAL. LOW SPEED CENTRIFUGE ScanSpeed MiniVac And ScanSpeed MaxiVac. Revision : 01 Date : Cat. No. :

GESTRA. Steam Traps and Steam Trap Testing. For all applications

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

MARUTI ENGINEERING WORKS

FUEL-FIRED VERTICAL TUBELESS BOILERS

Systems for central heating

P-K COMPACT SEMI-INSTANTANEOUS INDIRECT WATER HEATERS

OPX INDUSTRIAL RANGE THERMAL OIL

Transcription:

Condensate Recovery and Return System SDR A Condensate tank of rectangular design type SDR A with high-pressure centrifugal pump(s) installed next to the tank condensate coming from steam users or flash vessels. From the tank the conden sate is pumped into the feedwater tank by a level-controlled pump, in most cases via a deaerator. Rectangular condensate tank type SDR A The standard range of rectangular condensate tanks is designed for condensate flowrates of up to 8 t/h and a max. service pressure of 0.1 bar g. Tank made of steel type S235JRG2, inside: untreated, outside: anti-corrosion coating with two condensate pumps and accessories installed next to the tank, e. g. bimetal dial thermo meter, water-level indicator, GESTRA level electrode and control for auto matic pump operation, non-return valves, shut-off valves, high-pressure centrifugal pump(s) and pressure gauge. Completely assembled and inter connected, control cabinet supplied but not mounted. 1 340 1 2 550 2 3 750 3 4 1000 4 5 1500 6 6 2000 8 Vessels in compliance with Conformity Assessment Section 4, Paragraph 3 Tanks and valves made of other materials available on request.

Open-Type Condensate Recovery and Return Tank SD L 100 Condensate receiver tank of cylindrical design type SD L (S) with high-pressure centri fugal pump(s) installed next to the tank L = horizontal design; S = vertical design Max. condensate temperature 90 C I 250 1 II 390 2 III 850 4 IV 1370 6 V 2100 9 VI 2900 12 VII 3800 16 VIII 4500 20 IX 5900 25 X 6900 30 condensate coming from steam users or flash vessels. From the tank the conden sate is pumped into the deaerator by level-controlled pumps. Open condensate tank of cylindrical design type SD L (S) The standard range of cylindrical condensate tanks is designed for condensate flowrates of up to 30 t/h and a max. service pressure of 0.5 bar. Condensate tanks for larger flowrates available on request. Tanks available as horizontal or vertical design, made of steel S235JRG2, inside: untreated, outside: anti-corrosion coating. Two high-pressure pumps and associated valves and accessories installed next to the tank: e. g. bimetal dial thermometer, pressure gauge unit, water-level indicator, GESTRA level control and level electrode for automatic pump operation and non-return valves are part of the installation. Other valve and tank materials available on request.

Closed-Type Condensate Recovery and Return Tank SD L 130 Condensate receiver tank of cylindrical design type SD L (S) with horizontal-type centrifugal pump(s) installed next to the tank L = horizontal design; S = vertical design I 250 1 II 390 2 III 850 4 IV 1370 6 V 2100 9 VI 2900 12 VII 3800 16 VIII 4500 20 IX 5900 25 X 6900 30 condensate coming from steam users or flash vessels. From the tank the conden sate is pumped into the deaerator by level-controlled pumps. Closed condensate tanks of cylindrical design type SD L (S) The standard range of cylindrical condensate tanks is designed for conden sate flowrates of up to 30 t/h and a max. service pressure of 4 bar. Condensate tanks for larger flowrates available on request. Tanks available as horizontal or verti cal design, made of steel boiler plate type P265GH, inside: untreated, outside: anticorrosion coating. Two horizontal-type centrifugal pumps and associated valves and accessories installed next to the tank: e. g. bimetal dial thermometer, pres sure gauge assembly, magnetically operated liquid level gauge, level elec trode and control for auto matic pump operation, safety device, overflow, air vent, vacuum breaker, shut-off valves and nonreturn valves are part of the installation. Other valve and tank materials available on request.

Steam Powered Condensate Return Tank KH condensate from steam pro cessors or flash vessels. From the tank the condensate is returned to the main condensate tank or deaerator with the aid of level- controlled booster steam. Steam-powered condensate return unit KH... The standard version is suitable for condensate flowrates of up to 10 t/h and a max. service pressure of 12 bar g. The condensate return tank is made from steel type P265GH. Outside: anti-corrosion coating. Inside: untreated. Associated valves and equipment such as pressure gauge assembly, solenoid valve, level electrode and control for automatic booster steam supply, non-return valves are completely assembled and inter connected. capacity [m 3 /h] Booster steam pressure Pump capacity [bar] KH 13-2 50 2 12 8.4 KH 13-3 75 3 12 8.4 KH 13-5 100 5 12 8.4 KH 13-10 390 10 13 8.4 Other tank and valve materials available on request.

Steam Powered Condensate Return Tank FPS Booster steam pressure [barg] UNA 25-PS and UNA 25-PK are also available for flowrates of approx. up to 600 kg/h. For more details on the equipment see page 26 and the Price List. capacity FPS 11-13 45 10 up to 1000 kg/h FPS 23-13 75 10 up to 2300 kg/h FPS 14-13 100 10 up to 5000 kg/h condensate from steam processors or flash vessels. From the tank the condensate is returned to the main condensate tank or deaerator with the aid of float-controlled booster steam. Steam-powered condensate return unit type FPS 14... The condensate is returned to the main condensate tank with the aid of booster steam, without electric power. The standard version of the FPS 14 is suitable for condensate flowrates of 5 t/h and a max. service pressure of 12 bar g. The discharge capacity decreases with rising back pressure. The tank is made of steel type S235JRG2 or of P265GH. Outside: anticorrosion coating. Inside: untreated. The nonreturn valves are completely assembled and interconnected, inclusive of counter-flanges, bolts and gaskets.