PG&E s Applied Technology Services Hot Water Technology Performance Laboratory

Similar documents
Hot Water System Performance Testing at PG&E s Applied Technology Services: Mimicking a Full-Service Restaurant in the Laboratory

Commercial Water Heater Performance: Laboratory Testing and Modeling

Exploratory Lab Testing of a Residential-Scale Combined Space and Water Heating CO 2 Heat Pump

Updates From an In-Depth Hot Water System Replacement Project in a Full-Service Restaurant

Food Service Technology Center

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

Food Service Technology Center

CASE STUDY: HIGH EFFICIENCY HOT WATER SYSTEMS IN A COMMERCIAL KITCHEN. For the 2019 ACEEE Hot Water Forum, Nashville, TN

Specifying High-Efficiency Water Heaters for Food Service

HVAC Water chiller selection and optimisation of operation

Multifamily Buildings: Real World Monitored Data on Hot Water Energy and Water Use

CONTROLLED CHILLED BEAM PUMP MODULE

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

Demonstration of 2nd Generation Ducted GE "Brillion" Hybrid Water Heater in the PNNL Lab Homes

Food Service Technology Center

Sustainable Hot Water: Better Design, Delivery, and Use

IAQ: Re-tuning Commercial Buildings

Mul$family Buildings: Real World Monitored Data on Hot Water Energy and Water Use

endless quality and support

Hot Water Heating and Distribution Possible CASE Initiatives for 2011 T24 Standards

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

Product Training Module: Honeywell TruStability Board Mount Pressure Sensors: Uncompensated/Unamplified NSC Series

PlateScrape Plate Pre-Scrapper Test Report

The Opportunity for Gas-Fired Heat Pump Water Heaters

endless advances for your customers WATER HEATING SOLUTIONS FOR BUILDERS

CONTROLLED CHILLED BEAM PUMP MODULE

How to Cut Chiller Energy Costs by 30%

opti-visor ultra-efficient chiller plant automation Typical specification

Cool Savings Program Report

RFMA 2016 March 13 15

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

Submitted to. Texas A&M University at Commerce The Texas A&M University System. Submitted by. Guanghua Wei Craig Campbell David Claridge Dan Turner

Food Service Technology Center

A. Detail drawing M1 Standard Chilled Water Schematic 1.03 DESCRIPTION OF THE PULLMAN CAMPUS CENTRAL CHILLED WATER LOOP SYSTEM:

Water Piping and Pumps

APPLICATION GUIDE BEAMS

Metcraft Power Soak Performance Test

Continuous Commissioning: A Valuable Partner to Retrofit Projects

Food Service Technology Center

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS

February 21, 2003 Team Page 1

Christopher Kelly Technical Report Three

CHILLED WATER SYSTEM 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

Advanced diagnostics embedded in a pressure transmitter can detect integrity issues

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

Affordable ENERGY STAR Residential CO 2 HPWH for the US Market

SECTION ph/orp Sensors

Residential Water Heating

Best Practices for Condensing Boilers

M-SERIES. endless. quality and support. The highest standards of quality. 100 years of smart comfort. rinnai.us rinnai.ca

SECTION Free/Available Chlorine Analysis System

THE NEXT GENERATION IN CONDENSING BOILERS M-SERIES

Food Service Technology Center

NOTICE CONCERNING COPYRIGHT RESTRICTIONS

Emerson Automation Solutions Products & Services

Ronan Model X96S Series Density System

EZ Plate Instantaneous

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

Application of a Reagentless Direct Conductivity Online TOC Analyzer for Clean-in-Place Verification

HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING

PRACTICAL EXPERIENCE WITH AN ALTERNATIVE TO R-22 BASED ON R-32lR /R a. R E Low, B E Gilbert, T W Dekleva.

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

Innovative Technologies [and Design Concepts] in Commercial Foodservice

BLUE GALAXY DEPYROGENATION TUNNELS. Solid Dose Sol

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Jon Longtin Department of Mechanical Engineering SUNY Stony Brook

Energy Efficient Options for Residential Water Heating

Energy-Efficiency Options for Residential Water Heating

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Sunglo Heater Model A270 Patio Heater Performance Test

Experimental Verification of Cooling Load Calculations for Spaces with Non-Uniform Temperature Radiant Surfaces

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Tasmanian supplier of high quality instrumentation, control and electrical equipment for all industries. Mining, Food and Beverage, Water and

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

THE NEXT GENERATION IN CONDENSING BOILERS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

WATER HEATING & WATER TEMPERATURE CONTROL DIGITAL & FEED-FORWARD

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

F Prepared by: Kong Sham. Prepared for: PO Box Technology Center

Montague, Model Vectaire HX63A Gas Full-Size Convection Oven Performance Test

Hot Water. The Efficiency Challenge!

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 25- INTEGRATED AUTOMATION DESIGN STANDARDS SECTION INTEGRATED CONTROL OF FACILITY LAB FUME HOODS

System Considerations for Refrigerant Blends with Temperature Glide

Automatic Temperature Controller (ATC)

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Food Service Technology Center

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

3500/61E & 3500/67E Temperature Monitor

PROCESS CONTROL COURSES

Smarter Field Instrumentation Life Cycle Management. Ray Rogowski Global Marketing PMC Instruments

CONTENTS. B. System Design and Performance Requirements

Shell-and-Tube Heat Exchanger (Four Passes) - Optional

City of Duluth Festival Center 04/25

Evaluating Domestic Water Heater Performance for NY Homes NYSERDA Agreement 15606

Submitted to Reference Approval Construction Unit Designation Schedule #

Transcription:

PG&E s Applied Technology Services Hot Water Technology Performance Laboratory Edwin Huestis, P.E. Senior Mechanical Engineer PG&E Applied Technology Services ACEEE Hot Water Forum February 23, 2016

Presentation Objectives Describe the history of hot water testing at PG&E s Applied Technology Services (ATS) Summarize the results of the last effort lab testing effort on Identify the opportunities for future research presented at the conclusion of the last study Describe the vision of PG&E s Upgraded Hot Water Technology Performance Laboratory Identify how PG&E s laboratory will be modified to support of commercial kitchen field performance characterization research 2

PG&E Applied Technology Services (ATS) Vibration Analyses End use Equipment Testing Non-Destructive Examination Multidisciplinary team of Engineers, Technologists, Technicians and Scientists Act as an internal PG&E consultant, also perform some 3 rd Party work 3

History of Hot Water Testing at ATS Residential Water Heater Testing Started off supporting the development of ASHRAE standards 4

Residential Hot Water Draw Simulation Flow Measurement and Control 5

Residential Lab Hot Water Draw Simulation Flow Measurement and Control (Staged Volume Draws) ¾ Line Fed from EUT Remotely Actuated Isolation Valves Coriolis Flow Meter To Drain Pressure Compensating Valves 6

Field Characterization of Restaurant Hot Water Use (Completed by Fisher Nickel - FSTC) Fisher-Nickel conducted field monitoring at a quick service restaurant to gather a high resolution 24-hour real world hot water use profile

PG&E Applied Technology Services Commercial Water Heater Laboratory Configuration RECIRCULATION LOOP WATER HEATER UNDER TEST END USES W/ AUTOMATED VALVES PG&E installed and fully instrumented and functional replication of the hot water system monitored in the field study. Tested various retrofit and RCx measures. 8

PG&E Applied Technology Services Commercial Water Heater Laboratory Configuration (cont d) Commercial and Residential Testing in same lab space 9

Measuring Commercial Hot Water System Performance: System Delivery Efficiency vs. WH Thermal Efficiency ~ Output Energy/Input Energy 10

Measuring Commercial Water Heater System Performance: System Delivery Efficiency vs. WH Thermal Efficiency 11

Energy Performance Impact Summary: Standard Efficiency Tank-Type Water Heater - RCx and Retrofit Measures 12

Energy Performance Impact: Stratification in High Efficiency Tank-Type Water Heater Standby Loss & T.E. Standby Loss - 1.28% - 670.0 Btu/h 13

Energy Performance Impact: Stratification in Standard Efficiency Tank-Type Water Heater Standby Loss & T.E. Standby Loss - 2.58% - 1654.0 (Btu/h) 14

Opportunities for Future Research Distribution System Scenarios PG&E CHWH 15

PG&E Applied Technology Services Hot Water Technology Laboratory Vision Vision for PG&E s Upgraded Hot Water Technology Laboratory Include capabilities of past residential and commercial test systems Employ modular laboratory design, easily adaptable to changing test setups, specifically distribution system Design instrumentation plan and DAS system for versatility Automation of tests via National Instruments Labview DAS Continued focus maintaining high instrument accuracy and control of test variables Rely on industry for guidance and new ideas, also attempt to develop our own 16

PG&E Applied Technology Services Implementing the Hot Water Technology Laboratory Vision Hot Water Supply Commercial Units (Future) Residential/Other Units Tempered City Water Loop Pump Hot Water Demand Simulation of End Uses Tempering Tank Chiller Water Heater City Water Tempering System Hot Water Distribution System 17

Regulating City Water Pressure 18

Conditioning City Water - Tempering System Mixing Tank 1.5 Ton Chiller Hot Water Tank 19

Conditioning City Water - Tempering System 20

Distribution System Piping Rack 21

Hot Water Draw Simulation Flow Measurement and Control (Constant, Staged and Variable Volume) 22

Hot Water Draw Simulation Flow Measurement and Control (Constant, Staged and Variable Volume) 8 Simulated End Uses *ATS Likely to add additional end uses 1 2 3 4 5 6 7 8 2-Way Modulating Valve Flow Meters Constant Volumetric Flow Control Coriolis Mass Flow Meter (Collects all Flow For Comparison) 3-Way Diverter Valve (Throttling vs. Constant Volume) Solenoid Isolation Valve 23

Hot Water Draw Simulation Flow Measurement and Control (Constant Volume Draws) Single Draw From Distribution System 2-Way Modulating Valve (Open) Flow Meter Constant Volumetric Flow Control 3-Way Diverting Valve Isolation Valve To Drain Larger Pressure Compensating Valve Smaller Pressure Compensating Valve Volumetric Flow between.2 3.0 gpm (smaller valves).7 20 (larger valves) 24

Hot Water Draw Simulation Flow Measurement and Control (Variable Volume Draws) (Not Implemented Yet) Single Draw From Distribution System 2-Way Modulating Valve (Modulating) Flow Meter Bypassed Constant Volumetric Flow Control 3-Way Diverting Valve Isolation Valve To Drain Variable Volume Flow Draw Equivalent Constant Volume Flow Draw Equivalent Staged Volume Flow Draw Flow Flow Flow 25

Temperature Measurement and Calibration Isothermal Block for Temperature Calibration 4-wire RTD s Almost Exclusively Used 26

Pressure Measurement and Calibration Rosemount Pressure Transmitters for Natural Gas Flow Compensation *Omega pressure transmitters purchased for measuring pressure drop in piping network Dead Weight Tester Calibration Standard 27

Flow Measurement and Calibration Diaphragm Meter w/ Pulsing Transmitter Coriolis Flow Calibration Standard Coriolis Flow Meter Nutating Disc Hot Water Meter 28

Opportunities for Future Research Account for Human Factors 29

Accounting for Human Factors Temperature Feedback and Min Temperature Criteria Single Draw From Distribution System 2-Way Modulating Valve (Modulating) Flow Meter Bypassed Constant Volumetric Flow Control 3-Way Diverting Valve Isolation Valve To Drain Force solenoid valve to remain open until water reaches specified temperature, and for a specified duration/volume 30

Summary of Test Conditions Build Baseline and Optimized Distribution System on Rack Run Tests using each of the following (2) Standard Efficiency Tankless Units (199,000 Btuh ea) (1) Condensing Tankless (250,000 Btuh) (1) Standard Efficiency Tank (199,000 Btuh) (1) Condensing Tank (199,000 Btuh) If possible, vary recirc return port location (upper/lower) Add insulation, program timeclock, aquastat, D mand circulation, modify drop dimensions Run a variety of flow profiles if time permits 31

Thank You Questions? EMHk@pge.com 32