Machine needle shut-off nozzle type-s

Similar documents
Machine needle shut-off nozzle Type SHP (high performance) spring operated

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Model: 1100 Float-Controlled Condensate Trap, PN 25

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Installation, Operating and Maintenance Guide

Crimping tools for D-Sub contacts Crimping tools for other contacts Crimping machine TC-C

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

VERTICAL COOKING PRECISIO/PRECIJET COMBI OVEN PRECISIO/ PRECIJET OVENS S.A.V. MAINTENANCE AND REPAIR

VERTICAL GLANDLESS PUMP

Dosing system. Commissioning and maintenance manual eco-pen300

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

AXPR Wall Mounted Axial Panel Fans

Machine Nozzles Injection Nozzle

HD Kompakt Service Manual

Installation, Operating and Maintenance Guide

Heat Exchanger Tube Change Procedure

RTP9 ROTARY TABLET PRESS USER MANUAL

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Thermostatic valves with radiator connection systems

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

Mechanical Seal RG-4 stationary, double, liquid sealed

Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system

Aquatique. Shower heads. Fixed and adjustable height heads. Aquatique shower kits installation guide page 1

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

Semi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual

Grinding mill MISTRAL 50L (art. 650P)

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Tools and Accessories

REMOVE AND INSTALL AIR CLEANER ASSEMBLY

Control valves for floor heating systems. Floor Heating Manifolds

Laboratory Twin-Screw Kneader Modular design easy to use versatile in application

Technical Data Sheet No. JS-SM-38 DOCUMENT TITLE 3.5KG CARBON DIOXIDE FIRE EXTINGUISHERS

Mechanical seals external, single or double, to DIN EN 12756

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

INSTRUCTION MANUAL W-400

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Hose Clamps, Charge Air Cooler, Replacement page 2

Instructions for Installation, Operation, Care and Maintenance

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Operation Manual. Diaphragm pumps 2-headed. Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep

POLYTEST. Model 2 Test Sample Injection Moulding Apparatus. POLYMER TEST EQUIPMENT FOR WORLD WIDE QUALITY CONTROL

Service Instructions

Sealing Guideline (updated on Oct 13, 2015)

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

SERVICE MANUAL. Freestanding cooker 500 and 600 / Range Gas - electric Ceramic - electric Electric

EYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator

Temperature Sensor TRG Original Installation Instructions English

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Warranty Details page 2. Pump Description & Technical page 3 Specifications. Transportation, Storage & Installation page 4. Pump Maintenance page 5

Industrial Filters Replacement Procedure

Grain crusher Universal. Purpose: This machine is designed for the crushing of grain in agricultural operation.

Operating Manual. Automatic spray gun AGR-08-E for electrostatic atomization for solventborne paint

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

===================== LandyAir - Disco 3/4 &RR Sport

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)

MAINTENANCE MANUAL TAIYO SEIKI CO., LTD.

en Service Manual Coffee Machine EF 748 EF 749

Granulators Reprocessing Plastic Scrap into Valuable Regrind. world of innovation

INSTRUCTION MANUAL MODEL: 690E

PRO 2000i LOW LEVEL DEPOSITOR

TECHNICAL INSTRUCTIONS

Impeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 3 5

THERMAL CLEANING OF METAL PARTS & TOOLS

PS-2/ES Automated pack & tag machine with IndES fastening system

FIRE EXTINGUISHER SERVICING & MAINTENANCE INSTRUCTIONS

Manifold Cleaning and System Refurbishment...N3 Nozzle Heater and Hot Runner Component Repair...N4

INSTRUCTION AND REPAIR MANUAL

COMPONENT MAINTENANCE MANUAL

O P E R A T O R S M A N U A L M O D E L S PR 32 / 98 TRANSLATION OF THE ORIGINAL MANUAL

SuperKlean Washdown Products

GW MisteryHood Twin Nozzle System. Installation Guidelines. & Applications

Polti S.p.A. reserves the right to change equipment or accessory specification without prior notice.

Operating Instructions. PowerFill. Automatic Granulate Conveyor for perfectmelt SE

HEATING AND AIR CONDITIONING

OPERATING INSTRUCTIONS PRODUCT LINE EcoPower B6

THERMOSET PROCESSING. Technology and know-how for integrated solutions

E, F & G SERIES CENTRIFUGALS INSTALLATION INSTRUCTIONS

Safety. Operating instructions Ionization pilot burners ZAI, ZMI, ZKIH DANGER. Contents WARNING CAUTION Edition 12.11

MANUAL SWEEPER GUIDE. Model 920. Please make sure you read the instruction manual below and clear the operation before you use this sweeper.

EcoVision Door Manual

Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010

Series PX. Installation & Maintenance. Models: PX-3 PX-5 PX-7 1/2-HF PX-10-HF PX-15-HF. Materials: A - CPVC

Presentation for SPE PAM 2016 Conference Latest Developments in underwater pelletizing David Bargery Global Project Manager

Avensys Avensys FIN EST SLO RUS UAE

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

for Ultima-Tig and for Ultima-Tig-Cut

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

Venco 75mm (3 ) Standard and De-airing Pugmill

BioMaster 250/350/600 BioMaster Thermo 250/350/600

SHOT BLAST CABINET USER INSTRUCTIONS. Model No: CSB20B. Part No: GC05/13

KRAL Screw Pumps. L Series.

Technical Data Sheet No. JS-SM-40 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER

ASSEMBLY & OPERATING INSTRUCTIONS

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50.

Installation Instructions

Extrusion of single- and multi-lumen catheter tubes with thermoplastic materials

Level Electrode NRG NRG Original Installation Instructions English

Industrial Heaters for Plastic Applications

Transcription:

Machine needle shut-off nozzle type-s spring operated Applications: Thermoplastics (not applicable for PVC) Shut-off mechanism: Operated with one axial high performance spring Index of contents Chapter Page 1. Technical Description...2 2. Dimension sheet for orders or enquiries...3 3. Installation instructions...4 4. Nozzle design / Service...5 5. Integrated melt filter in S-Type nozzle...6 6. Spare part order form...7 1

1. Technical Description The S-nozzles are used in the processing of thermoplastics. The nozzle size required depends on the injection rate per second (cm 3 /s). Clean shut-off of the melt and reliable closing during metering are the functions of an A- nozzle and an essential requirement for a smooth, reliable and economic production process. The S-nozzle meets these requirements and has a compact, modular design, trouble-free operation and maximized flow geometry. The reliable shut-off system separates the melt flow at a predefined point determined by the process. Systematic wear protection ensures a long life span. A filter module broadens the range of functions and possibilities of the S-nozzle. What can you expect from the needle shut off nozzle type S? Disconnection of the melt stream at a definite point. Shorter cycle time Higher productivity Process reliability and repeatability Usable with increased back pressure improved homogenisation Adjustable opening pressure. Variable spring tensions. Easy assembly in a short time High operational safety Compact design All parts are interchangeable, easy disassembly Add-on capability ( on tool side with; filter) Needle Needle Sleeve The spring operated needle shut-off machine nozzle(type S) is opened directly from the injection pressure and closed again with spring power. A needle which moves axially in the needle shut-off nozzle is held in the closed position by the force of the spring. The nozzle orifice is normally closed. With the increasing melt pressure exerted against the spring through a ring of exposed surface area on the needle, the nozzle opens at 200 bar. If the melt pressure drops (80bar), the nozzle closes. If a different opening pressure is required, the pressurised ring area on the needle must be enlarged (lower opening pressure) or reduced (higher opening pressure). Modifications should not be made to the compression spring as this shortens its life. Pressure bolt Spring A temperature-resistant material is used for the spring. (Heat-resistant to 520 C max.). 2

2. Dimension sheet for orders or enquiries Company Street Zip/City Contact Tel / Fax E-Mail Operating data S0 S1 S2 max. injection flow rate cm 3 / s based on Polystyrol (PS) 45 500 1600 approx. worm diameter in mm max. 20 20-50 50-120 opening and back pressure 200 bar max. injection pressure / temperature 2000 bar / 350 C A0 A1 A2 Machine type Filter module Standard filter gap A0=0.3 / A1=0.5 / A2=0.8 Abrasion protection (over 30% fillers) Standard dimensions S0 S1 S2 K tip lenght installation wrench (AF) 15 19 18/28 24 30 41 (36) M max. orofice 2,5 mm 5 mm 8 mm N body lenght (excl. B) installation wrench (AF) 75 41 J heater band 40x48 375 W 45x60 480 W 60x70 680 W 110 46 134 60 Your dimensions Key A B C D E G H K L M O / O1 connection thread thread length incl. length of centering device (E) inlet diameter centering diameter length of centering device temperature sensor temperature sensor depth tip length (standard length above) tip radius nozzle tip orifice check: immersion depth of screw tip / angle Technical modifications reserved We need additional information for requirements, which vary from our standard range e.g. drawing sample. Our customer services will be pleased to help you. 3

3. Installation and operation Mounting A) Maximum working conditions : 2000 bar at 350 C NOTE: Nozzle is supplied without heater band and temperature sensor. Can be supplied as an Option. Legend match temperatures 1. Grease sealing surfaces and threads with high temperature paste 2. Mount Nozzle incl. heater band and sensor smear with high temperature paste B) 1. 2. Mount nozzle according to the torque specified in the machine handbook. Initial operation: Heat nozzle to process temperature. Repeated operation: Melt the polymer fully in the nozzle. First eject the heated material. This is done by extrusion at low speed (time 25-30 sec.) or by ejection at three to five times the injection time. Production can begin when the nozzle temperature is the same as the melt temperature. When the machine is at rest, lower the nozzle temperature. 2. 1. Match temperatures 2. Tighten (torques: page 5) Some plastics give off gases when they are left for a long time in stationary, heated nozzles. These can escape in an explosive fashion through the outlet hole. Leakage: A melt film is formed between the needle and its guide which prevents blockage of the needle. The melt film is continuously renewed and is finally discharged as minor leakage in the form of decomposed polymer. Major leakage means tolerance is too great (Standard 0.02mm). 4

4. Nozzle Design / Service Assemble the nozzle according to the numerical order. Disassembling the opposite way around. Parts may vary according to customer specifications. Procedure 1. Clamp the hexagonal part in a vice. Unscrew the tip 2. Remove shut-off parts using a punch 3. Insert the shut-off part reversed back into the body and reinsert positioning pin 4. Use a ring spanner on the three stabilisation extrusions to screw off spring chamber Key Quantity Description 1 1 Body 2 1 Tip 3 1 Needle 4 1 Needle guide 5 1 Positioning pin 6 1 Pressure pin 7 1 Spring 8 1 Spring chamber 9 1 Heater band 10 1 Temperature sensor Tools required S0 S1 S2 Tip - Hexagonal wrench: AF 19 / 60Nm AF 24 / 200Nm AF 41(36) / 520Nm Spring chamber - Ring spanner: AF 11 / 20Nm AF 19 / 40Nm AF 25 / 50Nm Help tools: punch, pliers, hammer Before dismantling we recommend cleaning the nozzle in a fluidized-bed or ultrasonic cleaning tank. If cleaning equipment is not available, heat the nozzle with a band heater or gas torch and dismantle as described while it is hot. Clean individual parts with a wire brush. Best results for nozzles used with materials like LCP, PPS or PEEK can be expected, if the nozzle is heated up to 500 C and hold it at that temperature level for about 2 hours. If you do so the material will burn. Do not heat above 520 C ± 20 C! Before reassembling lubricate all the threads with high temperature resistant grease. Check that all the parts are working correctly before reassembling. Check the seal surfaces for damage and the individual parts for wear. Parts subject to wear For optimum productivity you should always stock the following parts: Spring, Heater band, Temperature sensor. To order replacement parts see page 7. Make the most of our inexpensive cleaning service. The nozzle is dismantled and checked by us. 5

5. Integrated melt filter in S-type nozzle General Added use of recycled material demands a final, important filtration directly before injecting. For a proper function of the mold (hot runner systems) a final filtration of the recycled material is imperatively needed. The herzog melt filter is based on the so called gap filter principle and will be assembled into the existing spring operated shut-off nozzle without any modification. Standard measurements of the filter gap: Nozzle S0 0.3 mm S1 0.5 mm S2 0.8 mm Standard System Filter System Interchangeable part Retrofitting Just by changing the standard spring chamber with a filter-spring chamber the retrofit is already done and the nozzle is again operational. Please disassemble the nozzle according to service sheet (page 5). Cleaning To clean the filter, the nozzle tip needs to be disassembled. Take shut-off unit out of the body together with the filter. Clean and install again. Attention: Before tightening the tip, please pay attention to the fact that an equal temperature level between the tip and nozzle is needed. Torque on the tip according to service sheet (page 5). For inquiries or orders please use the data sheet on page 3. 6

6. Spare parts order form Your full contact information please: Company Street Zip/City Contact Tel / Fax E-Mail Identity Nr. (marked on the hexagonal part) Quantity Part name / no. (see page 5) Send to: Xaloy Inc., 72 Stard Road, Seabrook NH 03874 Phone +603 929 82 46 / Fax +603 929 82 47 www.xaloy.com 7