Project General Notes DESCRIPTION ABBREVIATIONS AIR CONDITIONER ABOVE FINISHED FLOOR BALANCING DAMPER

Similar documents
DRAWING SCHEDULE TAB REQUIREMENTS BY EQUIPMENT TYPE TYPE OF EQUIPMENT DESCRIPTION COMPONENT TAB REQUIREMENTS

SHOE PALACE HUNTINGTON PARK M.200

EXHAUST FAN SCHEDULE

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

DOCUMENT TABLE OF CONTENTS


HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

GRILLE, REGISTER AND DIFFUSER SCHEDULE

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION

SECTION PLUMBING

DIVISION 15 MECHANICAL

Inspection Checklist Mechanical Rough in

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Mechanical System Description

1.1 This section applies to air handling units for HVAC Systems.

Indirect Gas-Fired Make-Up Air

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

G101 SCHOOL AIR CONDITIONING UPGRADE - PROJECT #3 SUNSET ELEMENTARY COOLING UPGRADE 2014 NORTH 250 WEST SUNSET, UTAH 84015

SECTION AIR OUTLETS AND INLETS

SECTION DUCTWORK

HVAC Equipment Access Equipment Location

VERTICAL FAN COIL UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

Modular Supply Make-Up Air Unit

Advance Release September 2009

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

GENERAL PLUMBING NOTES

SECTION WATER-SOURCE UNITARY HEAT PUMPS

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

PLAN REVIEW SUBMITTAL GUIDE

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

SECTION (15820) - AIR DUCT ACCESSORIES

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Building Department Informational Handout

Inspection Checklist Residential Mechanical Rough In July 2016

SAFETY AND INSTALLATION MANUAL MODEL 8100

62DA,DB,DC,DD,DE,DF07-38

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

2016 Plumbing Supplemental Plan Review List

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

COMcheck Software Version Interior Lighting Compliance Certificate

Direct Fired Heater Model AD Specification

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

SECTION AIR HANDLING UNIT

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Installation Instructions

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

SKYPAK II, 3 Ton Series, gives you a

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

OKLAHOMA STATE UNIVERSITY - BUILDING DESIGN STANDARDS

SAS Steadyair Make-Up Air Units Technical Guide

SKYPAK II, 3 Ton Series, gives you a

2012 INTERNATIONAL FUEL GAS CODE VENTS

RG7D 1-Stage Heat Series

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Appendix B. Symbols for Drawings. Table B.1. Air moving devices and ductwork symbols. Air Movement. Fans. Axial flow fan.

Heat or Energy Recovery Ventilation System

FAARM-Underground Facility. Conceptual Design Review. Mechanical Systems. Dunham Associates, Inc.

Inspection Checklist Mechanical Final

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

INSTALLATION INSTRUCTIONS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

JCseries EVAPORATIVE CONDENSER. engineering data

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

CHAPTER 9 VENTS SECTION

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

SKYPAK II Heating & Cooling Self Contained Packages

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

Cabinet Unit Heaters Steam / Hot Water

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

SECTION AIR DUCT ACCESSORIES

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.

1 Exam Prep Florida Building Code-Mechanical Tabs and Highlights

Transcription:

G T D-X 000/000 DOMESTIC COLD WATER PIPE DOMESTIC HOT WATER PIPE DOMESTIC HOT WATER RETURN PIPE NATURAL GAS PIPE SANITARY VENT PIPE SANITARY PIPE DUCT SMOKE DETECTOR RELAY COIL THERMOSTAT TEMPERATURE SENSOR KEYED NOTE DESIGNATION EXHAUST FAN SUPPLY DIFFUSER RETURN GRILL ELECTRIC THERMOSTAT UNION BALANCING OR PLUG COCK RISE IN PIPING DROP IN PIPING VALVE IN RISE OR DROP DIFFUSER COOLING/HEATING AIRFLOW BASED ON: INTERNATIONAL ENERGY CONSERVATION CODE 2009, SECTION 803.2.8 /PLUMBING LEGEND (ALL S MAY NOT BE USED) BALL VALVE BUTTERFLY VALVE GLOBE VALVE GATE VALVE DRAIN VALVE MANUAL AIR VENT. GRISWOLD FLOW CONTROL VALVE TWO-WAY CONTROL VALVE PNEUMATIC BYPASS VALVE TRIPLE DUTY VALVE CHECK VALVE GAUGE COCK BALANCING VALVE GAS COCK GAS PRESSURE REGULATOR GAS SOLENOID VALVE W/HI-LO FIRE RELIEF VALVE PETE'S PLUG THERMOMETER W/WELL PADDLE TYPE FLOW SWITCH DIFFERENTIAL PRESSURE FLOW SWITCH DIFFERENTIAL PRESSURE SENSOR PRESSURE GAUGE SENSOR WELL FLEXIBLE CONNECTOR STRAINER MALE HOSE CONNECTOR PIPING REDUCER PIPE ANCHOR PIPE GUIDE PIPE EXPANSION LOOP EXPANSION JOINT UNION FLOW ARROW TEE CONNECTION NEW TO EXISTING CONNECTION DUCT AND PLENUM INSULATION AND SEALING: ALL SUPPLY AND RETURN DUCTS AND PLENUMS SHALL BE INSULATED WITH A MINIMUN OF R-6 INSULATION WHEN LOCATED IN UNCONDITIONED SPACES AND A MINIMUM OF R-8 INSULATION WHEN LOCATED OUTSIDE THE BUILDING. WHEN LOCATED WITHIN A BUILDING ENVELOPE ASSEMBLY, THE DUCT OR PLENUM SHALL BE SEPARATED FROM THE BUILDING EXTERIOR OR UNCONDITIONED OR EXEMPT SPACES BY A MINIMUM OF R-8 INSULATION. EXCEPTIONS: MINIMUM DUCT INSULATION 1. WHEN LOCATED WITHIN EQUIPMENT. 2. WHEN THE DESIGN TEMPERATURE DIFFERENCE BETWEEN THE INTERIOR AND EXTERIOR OF THE DUCT OR PLENUM DOES NOT EXCEED 15 F (8 C). AC A.F.F. BD BFP CO COTG CW DCO DF D-1 ESP EX FCO EXT, EXIST FD FS FPH FHB F-1 GPM HB HW LAV NO. OSA PSI RG RM TYP UH UNO UR VTR WCO WC WH ABBREVIATIONS AIR CONDITIONER ABOVE FINISHED FLOOR BALANCING DAMPER BACK FLOW PREVENTER CUBIC FEET PER MIN CLEANOUT CLEANOUT TO GRADE COLD WATER DOUBLE CLEANOUT DRINKING FOUNTAIN DIFFUSER TYPE EXT STATIC PRESS EXHAUST GRILL EXISTING FLOOR CLEANOUT FLOOR DRAIN FLOOR SINK FREEZE PROOF HYDRANT FREEZE PROOF HOSE BIBB FURNACE TYPE GALLONS PER MIN HOSE BIBB HOT WATER LAVATORY NUMBER OUTSIDE AIR POUNDS PER SQ IN RETURN GRILL ROOM TYPICAL UNIT HEATER UNLESS NOTED OTHERWISE URINAL VENT THRU ROOF WALL CLEANOUT WATER CLOSET WATER HEATER MINIMUM PIPE INSULATION BASED ON: INTERNATIONAL ENERGY CONSERVATION CODE 2009, SECTIONS 504.4 AND 504.5. FOR AUTOMATIC-CIRCULATING HOT WATER SYSTEMS, PIPING SHALL BE INSULATED WITH 1" OF INSULATION HAVING A CONDUCTIVITY NOT EXCEEDING 0.27 BTU PER INCH/HXFT2X F. THE FIRST 8' OF PIPING IN NONCIRCULATING SYSTEMS SERVED BY EQUIPMENT WITHOUT INTEGRAL HEAT TRAPS SHALL BE INSULATED WITH 0.5" OF MATERIAL HAVING A CONDUCTIVITY NOT EXCEEDING 0.27 BTU PER INCH/HXFT2X F. MINIMUM PIPE INSULATION BASED ON: INTERNATIONAL ENERGY CONSERVATION CODE, SECTION 803.2.8 Project Project A. ALL WORK SHALL BE COMPLETED IN FULL COMPLIANCE WITH THE 2009 UPC, 2009 UMC, 2009 IECC, NFPA AND ALL LOCAL CODES AND ORDINANCES. B. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE LAY OUT AND INSTALLATION OF THE PLUMBING SYSTEMS INCLUDING ALL COORDINATION WITH NEW AND EXISTING SERVICES EQUIPMENT, DUCTWORK AND ELECTRICAL EQUIPMENT. C. CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL COORDINATION OF OUTAGES WITH BOTH THE OWNER AND UTILITY COMPANIES, FOR UTILITY CONNECTIONS. D. CONTRACTOR SHALL VERIFY INVERTS BEFORE ROUTING ANY PIPING. E. WASTE PIPING SHALL BE PVC OR CAST IRON. VENT PIPING MAY BE PVC PIPE OR CAST IRON ABOVE AND BELOW FLOOR, PER UPC LIMITATIONS, AND CITY CODES. F. ALL WATER PIPING SHALL BE TYPE M COPPER ABOVE FLOOR AND TYPE L SOFT COPPER BELOW FLOOR OR CROSS LINKED POLYETHYLENE (AQUAPEX) TUBING MEETING ASTM F87-99A ABOVE AND BELOW FLOOR. G. NATURAL GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL ABOVE GRADE AND SHALL BE EITHER PROTECTED SCH 40 BLACK STEEL WRAPPED OR SDR-11 POLYETHENE BELOW GRADE. H. SEE EQUIPMENT SCHEDULE FOR EQUIPMENT TYPES AND SIZES. MINIMUM BURY DEPTH FOR WATER IS 4' AND 2' FOR GAS. I. ROUTE PIPING AS NEARLY AS POSSIBLE TO ROUTES INDICATED ON. CONTRACTOR IS FREE TO MAKE MINOR CHANGES IN ROUTING TO ACCOMMODATE CONDITIONS. J. CONTRACTOR RESPONSIBLE FOR ALL REQUIRED TRANSITIONS, OFFSETS MINOR RELOCATIONS, AND ALL ASSOCIATED FITTINGS K. CONTRACTOR SHALL INSTALL A COMPLETE OPERATING SYSTEM, INCLUDING REFRIGERANT PIPING, EQUIPMENT, CONTROLS, AND CONDENSATE DRAIN TO APPROVED INDIRECT WASTE. L. ANY LINES ENCOUNTERED WHICH MAY INTERFERE WITH NEW CONSTRUCTION SHALL BE RELOCATED IF ACTIVE AND REMOVED IF INACTIVE. M. ALL WATER PIPING LOCATED IN EXTERIOR WALLS OF THE BUILDING SHALL BE INSULATED WITH 1/2" INSULATION AND BE LOCATED ON BUILDING INTERIOR SIDE OF INSULATION. N. ALL HW/CW, P-TRAPS AT HANDICAPPED LAVATORIES SHALL BE INSULATED. O. CONTRACTOR SHALL PROVIDE 12" RISERS, CAPPED AT EACH FIXTURE FOR SHOCK ABSORPTION OR A SHOCK ABSORBER UNIT FOR THE SYSTEM. P. PROVIDE WALL CLEAN OUTS AND SHUT OFF VALVES AT ALL SINKS AND WALL MOUNTED URINALS. Q. PROVIDE ESCUTCHEONS AT ALL PIPE PENETRATIONS OF WALLS AND FLOORS. R. PROVIDE SHUT-OFF VALVES AT PLUMBING RISES. S. PROVIDE GAS COCKS AND FLEXIBLE CONNECTIONS AT EACH GAS OUTLET OR APPLIANCE. T. AND PLUMBING EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. U. SANITARY VENT TERMINATIONS SHALL BE A MINIMUM DISTANCE OF 10' HORIZONTALLY OR 3' ABOVE ANY BUILDING OPENING OR AIR INTAKE. V. DUCTWORK SHALL BE FABRICATED AND INSTALLED PER SMACNA STANDARDS, AND UMC STANDARDS. W. CONTRACTOR SHALL COORDINATE WITH ELECTRICAL AND ARCHITECTURAL TO DETERMINE FINAL DIFFUSERS LOCATIONS. X. INSULATE SUPPLY DUCTWORK PER TABLE THIS SHEET. WITH FOIL FACED EXTERNAL DUCT WRAP. PROVIDE ALUMINUM ROLL JACKETING MEETING ASTM B-206, H-14 TEMPER,.016" THICKNESS FOR EXTERNAL DUCT. Y. DUCT DIMENSIONS ARE CLEAR INSIDE. Z. INSTALL TURNING VANES IN RECTANGULAR ELBOWS. AA. ALL REGISTERS AND DIFFUSERS SHALL HAVE DAMPERS OR EXTRACTORS FOR AIR BALANCING. BB. INSTALL SPLITTERS AT BRANCH CONNECTIONS. CC. CONTRACTOR SHALL HAVE INDEPENDENT TEST AND BALANCE CONTRACTOR BALANCE AIR FLOWS PER DRAWINGS AND ADJUST ALL TEMPERATURE AND CONTROL DEVICES. CONTRACTOR SHALL TEST RUN SYSTEM FOR A PERIOD OF 8 HRS., VERIFIED BY GENERAL CONTRACTOR, BEFORE GIVING NOTICE OF COMPLETION OF WORK. DD. CONTRACTOR SHALL INSTALL A PRESSURE REGULATOR AT THE INCOMING WATER SERVICE IF SITE WATER PRESSURE EXCEEDS 80 P.S.I. REGULATOR SHALL MATCH LINE SIZE. FF. CONTRACTOR SHALL PROVIDE ACCESS PANELS OF APPROPRIATE SIZE FOR ALL INACCESSIBLE REMOTE EQUIPMENT. GG. CONTRACTOR SHALL NOT MODIFY ANY STRUCTURAL MEMBERS SUCH AS BEAMS, COLUMNS, TRUSSES, ETC. HH. SEE ARCHITECTURAL DRAWINGS FOR ROOF DRAINS. II. ALL PIPING AND DUCTWORK THAT PENETRATES A FIRE RATED WALL SHALL BE SEALED WITH APPROVED FIRE STOPPING TO RESTORE THE FIRE RATING AND MAKE WEATHER TIGHT AS REQUIRED. SEISMIC RESTRAINT FOR WATER HEATERS. BASED ON: UNIFORM CODE SECTION 508.2. IN SEISMIC DESIGN CATEGORIES C,D,E, AND F, WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST HORIZONTAL DISPLACEMENT DUE TO EARTHQUAKE MOTHION. STRAPPING SHALL BE AT POINTS WITHIN THE UPPER ONE-THIRD AND LOWER ONE-THIRD OF ITS VERTICAL DIMENSIONS. AT THE LOWER POINT, A DISTANCE OF NOT LESS THAN 4" SHALL BE MAINTAINED ABOVE THE CONTROLS WITH THE STRAPPING. TEMPERATURE AND HOT WATER SYSTEM CONTROLS BASED ON: IECC 2009 CODE SECTIONS 504.3 AND 504.6 SERVICE WATER-HEATING EQUIPMENT SHALL BE PROVIDED WITH CONTROLS TO ALLOW A SET POINT OF 110 F FOR EQUIPMENT SERVING DWELLING UNITS AND 90 F FOR EQUIPMENT SERVING OTHER OCCUPANCIES. THE OUTLET TEMPERATURE OF LAVATORIES IN PUBLIC FACILITY REST ROOMS SHALL BE LIMITED TO 110 F. AUTOMATIC - CIRCULATING HOT WATER SYSTEM PUMPS OR HEAT TRACE SHALL BE ARRAINGED TO BE CONVENIENTLY TURNED OFF AUTOMATICALLY OR MANUALLY WHEN THE HOT WATER SYSTEM IS NOT IN OPERATION. 6.17.13 DATE: Gordo FILE NAME: NOTES & LEGEND TOC M-001

PLAN -EXISTING C-2 MECH. ROOF PLAN -EXISTING C-2 1 2 1. XXXX. 0 1 2 4 8 12 C-2 M-101

1 PLAN -EXISTING C-3 2 MECH. ROOF PLAN -EXISTING C-3 1. -. 0 1 2 4 8 12 C-3 M-102

1 D-1 40 6x6 D-2 150 8x6 D-2 125 D-3 200 D-3 200 10x6 PLAN -C-A 20x8 2 HEAT PUMP/DUCT DETAIL 0 1 2 4 8 12 1. -. C-A M-103

1 HP-1 D-4 400 RG-2 1 FC-1 EBB-1 D-4 400 PLAN - LAUNDRY 1. MOUNT FAN COIL ON GALVANIZED METAL PLATFORM. PROVIDE RETURN DUCT THROUGH WALL TO RG-2. SEE DETAIL SHEET M-501. 0 1 2 4 8 12 C-3 M-102

4"(10 cm) TYPE "B" VENT CAP (PIN 90502300) SIDE VIEW 6.17.13 Gordo 4"(10 cm) TYPE "B" VENT CAP ROOF FLASHING 18" (46 cm) MINIMUM FAN COIL MODULE CLOSET DOOR DATE: FILE NAME: ROOF CONDENSATE TO FLOOR DRAIN WITH AIRGAP RETURN AIR DUCT THROUGH WALL WATER HEATER FLUE DETAIL NYLON DRAW BAND TIE OFF TO ROOF STRUCTURE METAL BAND SUPPORT FLEX DUCT WITH 2" EXTERNAL INSULATION MAX. LENGTH 5'-0" LAY-IN SUPPLY AIR DIFFUSER W/ROUND NECK & O.B.D. T-BAR TYPE SUSPENDED CEILING SUPPLY DUCT SPIN-IN TAP FITTING W/AIR SCOOP & DAMPER 4"(10 cm) SINGLE WALL PIPE VENT ADAPTER APPROVED THIMBLE (PIN 90505600) (IF APPLICABLE) a) Refer to Installation, Operation and Service Manual for proper design. b) Type "B" vent materials must be used outdoors. c) An insulating thimble (P/N 90505600) is required to pass through combustible structures. d) 4" (10 cm) O.D. vent pipe, maximum 45 ft.(13.7m) in length may be used as shown above with an approved vent cap (P/N 90502300). NOTE: Condensate may develop when long vent pipes are used. It is recommended that the pipe length should be less than 20' (6m). e)when heater extension packages are used, they directly effect maximum vent length. Refer to Installation, Operation and Service Manual for requirements. 1 2 3 SUPPLY AIR DIFFUSER DETAIL ROOF EXHAUSTER DETAIL SPIN - IN FITTING WITH INSULATION GUARD. BALANCING DAMPER IN BRANCH DUCT. DIFFUSER BRANCH DUCT SUPPLY AIR DIFFUSER DETAIL DUCT LINER (IF REQUIRED) INSULATED FLEXIBLE DUCT, 5' MAX.. 4 5 24" PLENUM/ PLATFORM FINISH FLOOR TO INDIRECT WASTE HEAT PUMP DETAIL CONDENSATE PUMP P-1 RETURN GRILLE RG-2 DETAILS TOC M-501

EQUIPMENT SCHEDULE CEILING EXHAUSTER: CEILING MOUNTED SUPER-QUIET EXHAUST FAN; ALUMINUM BACKDRAFT DAMPER; EMBOSSED GALVANIZED STEEL HOUSING; STATIC AND DYNAMICALLY BALANCED CENTRIFUGAL BLOWER; HOODED WALL CAP WITH BIRDSCREEN; CEILING GRILLE. MODEL NUMBERS ARE GREENHECK. CAPACITIES ARE FOR SEA LEVEL. EBB-1 6.17.13 DATE: Gordo FILE NAME: MODEL ESP AMPS VAC/P/HZ SP-A50 51 0.125" 0.50 120/1/60 RANGE HOOD: STAINLESS STEEL; TWO POSITION LIGHT; RESILIENT VIBRATION ISOLATION MOTOR MOUNTS; 2 SPEED CENTRIFUGAL FAN; DISHWASHER SAFE ALUMINUM FILTERS; DUCT CONNECTOR WITH BUILT IN DAMPER; FRONT CONTROLS; ENERGY STAR RATING. MODEL NUMBER IS BROAN. HP-1 HP-3 FC-1 FC-3 D-1 D-2 D-3 D-4 RG-1 RG-2 MODEL # WIDTH VAC/P/HZ AMPS QDE30SS 30" 280 120/1/60 1.6 HEAT PUMP: OUTDOOR HEAT PUMP; 2 STAGE SCROLL COMPRESSOR; INTERNAL PRESSURE RELIEF VALVE; INTERNAL THERMAL OVERLOAD; HIGH PRESUURE SWITCH; LOSS OF CHARGE SWITCH; FILTER DRIER; LOW AMBIENT ACCESORY KIT; BAKED ON POWDER PAINT; DENSE WIRE COIL GUARD; CRANK CASE HEATER. MODEL NO. IS CARRIER. MODEL NO. COOLING HEATING WEIGHT VAC/P/HZ MCA BTUH BTUH LBS HP-1 25HCA624A0030 24,000 15,300@17 F 257 208/230/1/60 16.2 25HCA636A0030 36,000 22,600@17 F 269 208/230/1/60 23.7 HP-3 25HCA648A0030 48,000 29,200@17 F 295 208/230/1/60 29.8 FAN COIL: DX MULTIPOISE FAN COIL; SOLID STATE FAN CONTROL; 1-INCH INSULATION; MULTISPEED MOTOR FOR 2 STAGE COOLING AND CLG/HTG AIRFLOWS; PRE-PAINTED GALVANIZED STEEL CASING; METERING DEVICE AND CLEANABLE, PERMANENT FRAMED FILTER; FACTORY INSTALLED DISCONNECT; FIELD INSTALLED ELECTRICAL RESISTANCE AUXILIARY HEATER WITH INTERNAL CIRCUIT BREAKER HEATER PROTECTION. MODEL NO. IS CARRIER. MODEL NO. /SP COOLING HEATING BLOWER CLG/HTG BTUH BTUH HP FC-1 FV4CNF0020O5 875/0.5 24,000 15,300@17 F 1/2 FV4CNF0030O5 1050/0.5 36,000 22,600@17 F 1/2 FC-3 FV4CNF0030O5 1400/0.5 48,000 20,200@ F 1/2 VAC/P/HZ AUX. ELEC. 208/230/1/60 5 KW 208/230/1/60 5 KW 208/230/1/60 5 KW DIFFUSER: "TITUS" SUPPLY AIR GRILLE; MODEL 300RL; STEEL CONSTRUCTION; DOUBLE DEFLECTION; 3/4" BLADE SPACING; ADJUSTABLE BLADES PARALLEL TO LONG DIMENSION; OPPOSED BLADE DAMPER ADJUSTABLE THROUGH FACE; #26 WHITE FINISH. SIZE D-1 6"X6" D-2 8"X6" D-3 10"X6" D-4 12"X10 RETURN GRILLE: TITUS RETURN GRILLE; MODEL 350RL FIXED BLADES AT 3/4" CENTERS PARALLEL TO LONG DIMENSION OF GRILLE; OPPOSED BLADE DAMPER OPERABLE FROM FACE OF GRILLE; FINISH #26 WHITE; ALL STEEL CONSTRUCTION. SIZE RG-1 36"X36" RG-2 18"X18" P-1 CONDENSATE PUMP: LOW PROFILE; VERTICAL TYPE PUMP; LEAK PROOF ABS TANK; 3/8" BARBED DISCHARGE; SAFETY SWITCH; 6' POWER CORD; UL/CSA LISTED; 20' SHUTOFF HEAD; STAINLESS STEEL MOTOR SHAFT. MODEL NO. IS LITTLE GIANT. MODEL NO. CAPACITY HP VAC/P/HZ P-1 VCC-20 80 GAL/HR 1/30 120/1/60 MODEL NUMBERS GIVEN ARE TO ESTABLISH THE MINIMUM REQUIREMENTS OF THE EQUIPMENT SPECIFIED. IF AN ALTERNATE ITEM EQUALS OR EXCEEDS THE MODEL SPECIFIED, LITERATURE AND/OR SAMPLES SHALL BE SUBMITTED TO THE ARCHITECT AND ENGINEER FOR APPROVAL. EQUIPMENT SCHEDULE TOC M-601