Technical-Report for SL Lamp 5 W

Similar documents
NVLAP LAB CODE ISTMT Test Report. For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD

In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: ) Outdoor Pole/Arm-Mounted Area and Roadway Luminaires

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

In Situ Temperature Measurement

NVLAP LAB CODE For. Shen Zhen Green Works Lighting Co., Ltd. Floor 4, Bldg. A, No. 36-8, Yingtai Road,Dalang, Longhua, SHENZHEN,China.

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: AOK)

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For SHENZHEN SUNPER OPTO CO.,LTD. (Brand Name: SUNPER)

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

Models: LED-8088M40/LED-8088M40C,LED-8088E40/LED-8088E40C,LED-8088M57 /LED-8088M57C,LED-8088E57/LED-8088E57C

DRAFT. Models: LED-8085M30, LED-8085M30C; LED-8085M42, LED-8085M42C; LED-8085M57, LED-8085M57C

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Technical Report No. CPSA Rev. 00 Dated Test according to the test specification Evaluation and categorization

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

Test Report. Appliance EMF Testing

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. FCC MPE REPORT

AUGUST 2016 CONTENTS:

CERTIFICATE. Issued Date: Dec. 23, 2010 Report No.: 10C142R-ITCEP7V05

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Safer by Design Presented by- Abul Kashem BEng(Hons) MIET TÜV Rheinland UK Ltd. December 4 th, 2015

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

INSPECTION REPORT Nr IDD/S-09/922

RF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07

Page 2 of 14 Report Ref. No

Copy of marking plate:

TEMPORARY IMMERSION AND DUST TEST REPORT

Surface Temperature Tests on an LST Fan Convector

DUST TEST REPORT. :Gold Apollo Co., Ltd. Company Model Name :A27. Date of Received :APR. 19, 2006 Date of Tested :APR. 19, 2006

Environment Test Report

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Southern California Gas Company Customer Programs Department

LATCH UP TEST REPORT

Overview of Standards for CO Detection Products

onlinecomponents.com

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

The product and any acceptable variation thereto is specified in the Annex to this certificate and the documents therein referred to.

CE EMC Test Report EN :2015 EN :2017. Folder with powerbank ZKS E. Lieber Ouyang (Engineer) Lahm Peng (Manager)

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ETL Testing Laboratories, Inc.

WORLD TRADE ORGANIZATION

CERTIFICATE of Product Conformity (QAL1)

FOR PROFESSIONALS BY PROFESSIONALS *Suitable for hours daily, usage of the product. for 24 hours a day would void warranty

FCC COMPLIANCE REPORT. SHENZHEN STARWELL TECHNOLOGY CO., Ltd. AC/DC ADAPTER

WIO200 Water In Oil measuring instrument

The European Radio Equipment Directive 2014/53/EU

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-B

Sgm Lab Solutions.

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Technical Application Guide for UP-SHINE LED wall lamp UP-WL08-8W

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

62 MAX/62 MAX + Infrared Thermometer. Users Manual

Integration of IEC Standards and Conformity Assessment into LED Lighting Market In Korea DEONNA (KEUM) LEE

MEASUREMENT AND TEST REPORT

Declaration of Conformity

TEMPORARY IMMERSION AND DUST TEST REPORT

HSD Dry Cabinet

Infrared Thermometer

EMC TEST REPORT for HUIZHOU FREEWAY ELECTRONIC CO., LTD. Car DVD/Navigation Player

Procedure for the Approval of New Fire Detection and Alarm Technologies

Rosemount 4500 Hygienic Pressure Transmitter. Start

CERTIFICATE of Product Conformity (QAL1 )

Lighting Measurement Solutions

LED A Lamp B2B A60 Filament 60W E27

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

EL-USB-TC Thermocouple Data Logger with USB Interface


CE marking & your legal obligations

Not a Light, But a Design

TEST REPORT IEC60529 Edition TD990426C02

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

BC3250. Blowdown Controller

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

Pyroelectric Infrared Sensors

LHBXD LED Linear High Bay

Temperature and Calibration Capabilities

T.Y.C. BROTHER IND. CO., LTD.

Temperature and Calibration Capabilities

TEST REPORT: CHM14-05-CHY

CEN standardization work on refrigerating systems, especially standard EN 378

Listing Constructional Data Report (CDR)

Domestic Nuclear Detection Office (DNDO)

International Product Compliance and Certifications. Product Safety Consulting, Inc.

EasyLog Data Logger Series

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-E

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

Transcription:

Technical-Report for SL Lamp 5 W

Technical Report No. 68.184.17.478.01 Dated 2017-06-27 Client: Manufacturing place: Name: PHOCOS China Ltd. Address: 3F 1st Bldg. 4A Chang Yi Road, 266021, Qingdao, PEOPLE'S REPUBLIC OF CHINA Contact person: Ms. Wang Minhua Manufacturer s name: Same as client. Address: Same as client. Factory s name : Same as client. Address: Same as client. Test subject: Product: LED lamp Type: SL-5W Trade mark: PHOCOS Test specification: Long term lumen maintenance projection according to IES TM-21-11 and requirement of clients. Purpose of examination: inspection according to specified requirements to realize the conformity with the Produktsicherheitsgesetz ProdSG, version Nov 08, 2011 inspection according to specified requirements to realize the observance of the protection aims of the following EC directives: LVD directive 2014/35/EU EMC directive 2014/30/EU Test according to the test specification Test result: Based on the test result, the projecting long term lumen maintenance of above product is 84.53% and 79.82% at 15000 hours and 20000 hours through the method of IES TM-21-11. (See section 4 for details.) This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. Page: 1 of 10

1 Description of the test subject 1.1 Function Manufacturer s specification for intended use: LED lamp for general lighting purposes Manufacturer s specification for predictive misuse: No restrictions provided 1.2 Consideration of the foreseeable misuse Not applicable Covered through the applied standard Covered by the following comment Covered by attached risk analysis 1.3 Technical Data LED lamps (LED lamps) Model : SL-5W Rated Voltage : 12VDC or 24VDC Rated Frequency : -- Rated Power : 5W Rated CCT : 5700K 2 Order 2.1 Date of Purchase Order, Customer s Reference 2017-06-14 2.2 Receipt of Test Sample, Location 2pcs samples were received on 2017-06-14, EnE Department, Shenzhen 2.3 Date of Testing 2017-06-14 to 2017-06-27 2.4 Location of Testing Nantou Checkpoint Road 2, Nanshan District 518052 2.5 Points of Non-compliance or Exceptions of the Test Procedure None Page: 2 of 10

3 Test instruments and conditions 3.1 Test instruments Equipment Model Brand/Manufacturer Calibration due date Digital Power Meter WT210 YOKOGAWA 2017-08-28 Temperature data logger 34970A AGILENT 2018-04-26 Digital Multimeter 34401A AGILENT 2017-07-14 Digital Temperature and Humidity data logger HR641B MiEO 2018-02-24 Infrared camera Fluke Ti200 Fluke 2017-07-17 3.2 General conditions for measurement Ambient temperature( C): 25±1 C Maximum relative humidity: 50% Maximum air speed(m/s): 0.1 Test voltage tolerance: ±0.2% Test voltage and frequency 24VDC 3.3 Accreditation of Test Lab NVLAP LAB CODE 500067-0 TUV SUD Cert & Testing (China) Co., Ltd. is accredited by National Voluntary Laboratory Accreditation Program(NVLAP) for Energy Efficient Lighting Products Certificate of Accreditation: See Annex 1: NVLAP Certificate of Accreditation or log-in website https://www-s.nist.gov/niws/index.cfm?event=directory.search#no-back for confirm. The report must not be used by the client to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government. Page: 3 of 10

4 Test Result 4.1 Test data from submitted LM-80 report Description of LED Light Source Tested (manufacturer, model, catalog number) Model: LED2835-0.2W Current: DC60mA Manufacturer: SHENZHEN JIANGNA PHOTOELECTRIC CO., LTD LM80 report issued by: Shenzhen BST Technology Co., Ltd. Issued date: 2014-09-02 LM-80 Testing Details* Total number of units tested per case temperature: 20 Number of failures: 0 Number of units measured: 20 Test duration (hours): 6000 Tested drive current (ma): 60 Tested case temperature 1 (Tc, C): 55 Tested case temperature 2 (Tc, C): 85 Tested case temperature 3 (Tc, C): 105 * Remark: Test data extract from LM-80 test Report which generated for SHENZHEN JIANGNA PHOTOELECTRIC CO., LTD. Issued date: 2014-09-02, Issued by Shenzhen BST Technology Co., Ltd. Page: 4 of 10

4.2 Measurement Current/Voltage and Temperature In-Situ Inputs Measured Drive current for each LED package/array/module (ma): 58.3 In-situ case temperature (Tc, ⁰C): 69.4 Percentage of initial lumens to project to (e.g. for L70, enter 70): 70 Measured the DC forward current for a LED is 58.3mA when a forward voltage of 2.87V is applied. Thermocouple Location on the product: Input voltage: (V) 24.0 Input current: (A) 0.178 Input power: (W) No. Test part Temperature corrected at 25.0 C 101 LED 69.1 102 LED 69.4 103 LED 69.0 120 Ambient 25.0 The highest in-situ measured temperature of LED is 69.4 C. Remark: The temperature measurement point measured according to the LM- 80 which generated for SHENZHEN JIANGNA PHOTOELECTRIC CO., LTD. Issued date: 2014-09- 02, Issued by Shenzhen BST Technology Co., Ltd. 4.30 Page: 5 of 10

Annex 1: NVLAP Certificate of Accreditation. Page: 7 of 10

Annex 2: Photo of Ts Point in the LM-80 report and product Details of: Ts point in the LM-80 report Details of: Ts point in the prodcut Page: 8 of 10

Annex 3: Tables of TM-21 Report. Page: 9 of 10

Annex 4: Photo document Details of: Overview of SL-5W Details of: LED view --END-- Page: 10 of 10