ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection

Similar documents
ThermoDual Domestic hot water charging system

60 C water temperature ensures thermal disinfection during hot water production

30% Take lead on your project with an efficient system concept. lower energy.

30% Safe. Take lead on your project with an efficient system concept. Technical handbook Danfoss EvoFlat systems from A-Z. evoflat.danfoss.

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

PRODUCT INFORMATION. Solar DHW storage tank SKL. Technical description. High performance solar tank, bivalent

a Danfoss Platform for Flensburg Secondary Network

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems

Domestic hot water (DHW) The substation can be supplied with connection pipes for DHW cylinder on the supply or return line.

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Planning guide. (2010/09) en

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY

HW 22 District heating substation for indirect heating and domestic hot water systems

WL Instantaneous water heater

Brazed heat exchanger, XB

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Akva Lux VX District heating substation for indirect heating and domestic hot water systems

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

sustainable energy solutions

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

PrimusCenter DWC7000. Domestic Water Centre. Product specification sheet

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

Domestic Hot Water Application manual

PRODUCT INFORMATION. Technical description. Hygienic stratification storage tank HSK ÖKO Universal heat center for legionella safe preparation of DHW

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

UV disinfection. System. Type A Series. Main applications: Potable water, process water, hot water/legionellae DIN EN ISO 9001 DIN EN ISO 14001

ECOplus Solar Cylinder

Contact person Date Reference Page Daniel Månsson P (13) Energy and circular economy

TERMO Combi Cylinder TECHNICAL INFORMATION

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

Technical description. Atec.

Herz York Direct Heat Interface Unit

Increase the attractiveness of your multi-family building

WZS series. Hot water circulation systems for energy storage tanks

R. Boiler Energy Management System FW 200. Operating Instructions for the User (2010/05)

Akva Vita Instantaneous water heater

Technical paper Selection of district heating house stations

Contact person RISE Date Reference Page Björn Folkeson P03675B 1 (11) Energy and circular economy

Efficient DHW and heating solution with High-output calorifier Modul-plus

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Valves, controls + systems. Regucor WHS Energy storage centre. Innovation + Quality. Product range. v o. Awards: i y. n n

Flamco. Water heaters, storage tanks and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS WATER HEATERS, STORAGE TANKS

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

Technical Data Manual Model Nos. and pricing: see Price List

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Solar heating systems

In cooperation with. sustainable energy solutions

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

Brazed heat exchanger, XB

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

Danfoss Solar Solutions Application Handbook

Manual and installation instructions. Function. Operating phase

KEMPER ThermoSystem. For further information on KTS use the QR code!

District Heating Fact Finding Mission to DK for Energy Cities members September Experience with Low temperature DH in DK

Product news 2018/19. Heat pump system WIKOSOL HPS. Tank for wall boiler WBO TN. Vacuum tube collector WIKOSUN HP 2340 / 1240

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

Wall-mounted substation PKL-113

heat interface units A BOILER WITHOUT A FLAME

CASSETTE UNIT. Comfort Circle

RAYPAK HOT WATER & HEATING

Technical information for installation and operation

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

Technical paper Analysis on flat station concept (Preparing DHW decentralised in flats)

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

High-output calorifier Modul-plus

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

Contact person RISE Date Reference Page Björn Folkeson P (13) Energy and circular economy

Installation Guide DSA 1 MINI. Contents

Contact person Date Reference Page Björn Folkeson P (14) Energy and bioeconomy

2 OZONFILT And Bono Zon Ozone Plants

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

Installation and operating instructions. DK energy storage and DK energy buffer

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

Installation Guide. ECL Comfort 310, application A Table of Contents

Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy

FHM-Cx Mixing Shunts for Floor Heating

Contact person Date Reference Page Björn Folkeson P (15) Energy and bioeconomy

Brazed heat exchanger XB

HT V2 HT Split

Contact person Date Reference Page Daniel Månsson P07886B-rev2 1 (14) Energy and bioeconomy

Thermostatic mixing valves with replaceable cartridge for centralized systems

THERMAL STORE MAINS PRESSURE SYSTEM

TA-MATIC

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

K18 PLANT MANUAL. Heating and DHW

product overview ProControl

Transcription:

ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection Description/Application The ThermoClean system is compact and effective solution for legionella-free domestic water heating. The system uses the thermal disinfection methods, whereby the reaction temperature inside the installation is kept at a constant temperature of 70 C. The ThermoClean system is dimensioned in such a way that the water is warranted to remain in the reaction area of the device for at least 5 minutes. During tap operation, the reaction temperature of 70 C is cooled down to the required hot water temperature within the system. This is not achieved by the addition of cold water, but through an additional re-cooling heat exchanger which cools the disinfected water, while preheating cold water, that simultaneous preheat the cold water. The hot water temperature can be set at any temperature between 50 C and 60 C. 1 It means that the installation of a scaling protection device on the taps is redundant if the temperature is adjusted accordingly. Due to the connection of the circulation into the system a continual thermal disinfection of the hot water is ensured. The high quality stainless steel design of reaction and buffer storage tank, heat exchanger and piping is hygienically perfect, offers a maximum in operational safety and can be universally used in combination with the wide range of materials used in the connected domestic water supply network. 1 The recommended temperature is 60 C. Main system data: Primary Secondary DL/Combi Max. operating temp. ( C) 100 (150) 2 90 Max. operating pressure (bar) 16 (25) 2 10 Working medium Circulation water DHW 2 On request Approvals and Standards: - DVGW 3 Working paper W 553 Calculation for circulation systems in DHW installations, - DVGW 3 Working paper W 551 Technical method for prevention of legionella growth, - DIN 1988 - Code of practice for drinking water installations (TRWI) (when related), - DIN EN 806 - Specifications for installations inside buildings conveying water for human consumstions, - DIN EN 1717 - Protection against pollution of potable water installations and general requirements of devices to prevent pollution by backflow. 3 German Technical and Scientific Association for Gas and Water DEN-SMT/PL VD.KR.D.02 Danfoss 01/2013 1

ThermoClean -DL Domestic water heating system with electronic controls, a stainless steel reaction storage tank, charging and re-cooling brazed plate heat exchangers as well as charging pump, shut-off valves and complete stainless steel piping. ThermoClean -Combi Domestic water heating system with electronic controls, a combined stainless steel reaction and domestic hot water storage tank, charging and re-cooling brazed plate heat exchangers as well as charging pump, shut-off valves and complete stainless steel piping. The ThermoClean -Combi requires less installation space provided adequate height in the installation place is available. Ordering Explanation, ThermoClean types ThermoClean -DL 0200 TCTRL Electronic controller type Reaction tank volume (liter) DL with reaction storage tank and brazed plate heat exchangers Combi with combined reaction and DHW storage tank and brazed plate heat exchangers Domestic water heating system with charging and re-cooling system unit ThermoClean Code No. -DL -Combi 200 00X137-350 00X138 00X133 500 00X139 00X13 750 00X1350 00X135 1000 00X1351 00X136 1300 00X1352 - incl. electronic controller ThermoContol 2 VD.KR.D.02 Danfoss 01/2013 DEN-SMT/PL

Accessories ThermoClean -DL 1. Domestic hot water storage tank The ThermoClean system must be combined with additional domestic hot water storage tanks to provide the required capacity for peak consumption. The required storage tank capacity is based on the calculated peak flow and the length of the consumption period. The recommendations provided overleaf for the total storage tank capacity are based on peak consumptions lasting 1 hour or according to customer demands. If the consumption periods are shorter, the storage tank capacity can be reduced accordingly. We recommend the utilization of the following storage tanks: - Stainless steel domestic hot water storage tank series SE, - Tank sizes: 150... 8000 liters, - Optimum adaptation to requirements due to optional combination of multiple storage tanks. 2. Over-tapping protection Several unexpected factors can result in the complete consumption of the available storage tank capacity, which again can lead to the addition of domestic cold water to the hot water network that has not run through a proper thermal disinfection. The potential causes are for example: - Heating medium not available in sufficient quantity or at the adequate temperature, - Insufficient heat transfer in the heat exchanger due to fouling, - Technical defect of a system component (e.g., failure of the charging pump), - Peak consumption continues longer than the calculated consumption period. To address this issue, we offer products complementing our ThermoClean system that provide effective protection against system overtapping. If the storage tank capacity of thermally disinfected domestic water is beginning to run out, the protection interrupts the cold water supply to the system until the charging process has once again provided sufficient quantities of thermally disinfected domestic hot water via the reaction storage tank. Only after this process is complete, the cold water supply is established and the tapping of domestic hot water can be continued. The device is controlled via the ThermoClean system control with a manual switch (ON/OFF/AUTOMATIC). Over-tapping protection consisting of: - Motorized butterfly valve, nominal diameter corresponds to the selected ThermoClean system, actuator 1~230 V, three-point signal, - Control thermostat with stainless steel immersion pocket. ThermoClean -Combi 1. Over-tapping protection Please refer to above section ThermoClean -DL. accessories for separately order Technical data Performance index Connected load Max. power for peak consumption Heating (Hot) water flow at ϑ VL = 75 C Domestic hot water capacities Permanent capacity Peak capacity Charge flow total Circ. flow (max.) Heating water Resistance NL 5 kw kw l/h l/h l/h l/s l/h l/h kpa kpa kpa 200-6 8.. 6 10 280 1330.. 600 5000 1,389 200 1070.. 1800 2 5 19 350-6 17.. 80 25 0 2330.. 1050 7500 2,083 200 1870.. 3150 20 6 20 -DL 500-6 210.. 11 350 680 3330.. 1500 9000 2,500 6000 2670.. 500 22 58 20 750-6 315.. 171 525 9650 5000.. 2250 12000 3,333 9000 000.. 6750 23 59 23 1000-6 20.. 228 700 12960 6670.. 3000 15000,167 12000 5330.. 9000 29 65 27 1300-6 56.. 296 910 16980 8670.. 3900 20000 5,556 15600 6930.. 11700 35 86 30 350 15.. 9 55.. 30 91 1620 870.. 390 1090 1,111 1560 690.. 1170 20 56 18 -Combi 500 28.. 13 71.. 39 119 2120 1130.. 510 160 1,111 200 910.. 1530 21 56 19 750 1.. 21 88.. 8 17 2620 100.. 630 190 1,9 2520 1120.. 1890 22 9 1 1000 52.. 29 101.. 55 168 2970 1600.. 720 2360 1,9 2880 1280.. 2160 2 9 1 5 Performance index NL acc. to DIN 708 6 Dependent on the additional storage tank(s) DHW (max.) Circ. (max.) DEN-SMT/PL VD.KR.D.02 Danfoss 01/2013 3

Design and function ECD CPU 1 3 2 7 DTA 5 RTA SFV HEL CVE 5 HEC CVD LPU 6 RTA reaction tank/vessel HEL HEX charging/load HEC HEX cooling LPU charging pump/load CPU circulation pump (on site/by customer) SFV safety valve CVE control valve electrical ECD electronic controller DHW CVD control valve electrical domestic DTA domestic buffer tank (accessory) shut off device balancing valve sensor (direct, cable/universal, surface) 1) domestic water cold 2) domestic water hot 3) circulation ) heating supply 5) heating return 5) to domestic buffer tank (stainless steel) top 6) from domestic buffer tank (stainless steel) below 7) from domestic buffer tank thermometer drain / air vent (on site / by customer) check valve sampling valve The heat exchanger brings the system volume to the disinfection temperature of 70 C. A temperature sensor at the exit of the heat exchanger monitors this temperature and regulates the application of heat energy accordingly. The system is dimensioned to ensure that the domestic hot water remains in the reaction area for at least minutes to warrant the extermination of the legionella bacteria. The entire system volume is maintained at the defined disinfection temperature. Only when the water is tapped, the required quantity of water is cooled down to the demanded network temperature (50... 60 C) while the new cold water that is being added is preheated. Temperature fluctuations are balanced out by the mixing valve, so that the precise degree of water temperature indicated is definitely being maintained. Proven control technology ensures that the domestic hot water network is not heated up during breaks in tapping. If the consumption volume during peak times exceeds the charge flow of the system, the available storage tank volume is tapped. The optionally available over-tapping protection ensures that during unexpected functions (e.g. peak tapping continues for a period exceeding the determined consumption period) the cold water supply is suspended until sufficient thermally disinfected domestic water is once again available through the charging process via the reaction tank. The circulation water from the network enters the system, is once again heated up to 70 C by the charge heat exchanger and consequently incorporated into the thermal disinfection process continually. VD.KR.D.02 Danfoss 01/2013 DEN-SMT/PL

Sizing For dimensioning and selection of ThermoClean system please contact with Danfoss local sales representative. Mounting ThermoClean -DL After setting up, connect reaction and DHW storage tank, charge/re-cooling system unit via the pre-installed connections. Next the heating and domestic water connections, mains connections. Commissioning as described in the installation and operating instructions. ThermoClean -Combi After setting up, connect combination and DHW storage tank, charge/re-cooling system via the pre-installed connections. Next the heating and domestic hot water connections, mains connections. Commissioning as described in the installation and operating instructions. Dimensions ThermoClean -DL B1 B2 5 6 1 3 7 2 ThermoClean -Combi B1 2 3 H1 H2 H1 25 25 1 H2 B2 D d 5 6 1 7 3 2 T2 T1 D d 2 3 T2 1 T1 Connections Weight H2 B1 B2 T1 T2 H1 d D approx. approx. approx. approx. approx. 10 Storage Re-cooling Charging 1, 2 3, 5 5-7 tank 11 unit 7 unit 8 mm mm mm mm mm mm mm mm G/Rp G/Rp DN G/Rp kg kg kg 200 1565 1730 1905 G 1½ G 1¼ 25/20 G 1½ 70 10-500 60 725 600 9 350 2065 1795 1915 1000 G 1¾ G 1½ 0 G 1¾ 90 160-500 2110 600 70 185 2025 825 G 1¾ 90 170-650 -DL G 2 3 /8 G 2 3 /8 750 2270 750 9 930 1970 2365 1100 990 G 2 3 /8 50/0 155 230-1000 2550 800 9 980 2220 2570 1200 965 Rp 2 210 250 - Rp 920 Rp 2½ 1300 2575 900 9 1080 225 2680 1250 995 2½ Rp 65/50 235 300-21/2 -Combi 350 1995 500 60 1500 20 70 15 G 1½ G 1¼ 100 500 2035 600 70 1600 750 9 25/20 90 20 1800 800 - - 750 2115 750 890 1750 15 G 1¾ G 1½ 32/20 105 25 1000 2115 850 9 990 1900 750 195 7 For ThermoClean type -DL incl. charging unit 8 Mounted on the ThermoClean -Combi s tank 9 min. door width; when needed components has to demounted 10 max. width of frame 11 raw weight (without insulation/package) All connection axis measures are approximate and have a tolerance of +/- 15 mm. DEN-SMT/PL VD.KR.D.02 Danfoss 01/2013 5

6 VD.KR.D.02 Danfoss 01/2013 DEN-SMT/PL

DEN-SMT/PL VD.KR.D.02 Danfoss 01/2013 7

8 VD.KR.D.02 Danfoss 01/2013 DEN-SMT/PL