Spatial variation of radon concentration in a room ZHANG ZHENGGUO*, XIAO DETAO**, ZHANG LIANG*, LI CHUNXIU*,

Similar documents
Radon in elementary schools in Tunisia

Guide for Radon Measurements in Residential Dwellings (Homes)

Sensitivity to Thoron on Passive Radon Detectors

A study of Indoor Radon / Thoron Levels in Some Dwellings by using Solid State Nuclear Track Detectors

Outdoor radon concentration in China

Illuminated Stopper Station Push Button

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Radon and Thoron Measurements at Special Underground Circumstances

Design and Fabrication of New Radon Chamber for Radon Calibration Factor of Measurement

Wireless Outdoor Air Reset Adaptor PN:

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

Experimental Investigation of Purification Function of Air Conditioner

RADON CONCENTRATIONS AFFECTED BY DIFFERENT FACTORS IN TWO OFFICE BUILDINGS. Raimo Halonen, Pirjo Korhonen, Pentti Kalliokoski and Helmi Kokotti

Measurement Devices. Topic 5 - Audio 56

Analysis of a Heat Pump System Driven by Gas Engine for Domestic Use

PEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL

SEASONAL VARIATION OF RADON CONCENTRATION - MEASUREMENTS IN SOME EUROPEAN COUNTRIES

Radon Measurements in Argentina

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

International Requirements for the Control of Radon

Radon Detection Specialists, Inc.

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

Radon Testing Results. City Hall

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

Radon Detection Specialists, Inc.

PH:

Radon Detection Specialists, Inc.

PH:

Radon Detection Specialists, Inc.

Dynamic Radon Detection Over Measurement

Radon Detection Specialists, Inc. Love the Lungs You re With

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Radon Detection Specialists, Inc.

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

W8735ER Wireless Outdoor Reset Module

adsw worth Center, New York State Department of Health, Albany, NY 12201

Wi-Fi DOOR/WINDOW SENSOR

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:

Relevant Radon properties

RADON SURVEY IN KALAMATA (GREECE) Medicine, London SW7 2AZ U.K. Greece. Republic

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

Radon Survey Summary Report

Lumination TM Volumetric Retrofit Kit

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For:

A new passive integrating detector for measurement of individual radon exposure at working places.

INTERNATIONAL INTERCOMPARISON EXERCISE ON NATURAL RADIATION MEASUREMENTS UNDER FIELD CONDITIONS (IFC11) *

HISTORY OF SOIL-GAS RADON CONCENTRATION MEASUREMENTS IN THE CZECH REPUBLIC

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For:

Atomic Digital Office Clock

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

NRC Publications Archive Archives des publications du CNRC

Stopper II SERIES ADA. We protect the things that protect you

L'ARABE DU FUTUR - TOME 2 (FRENCH EDITION) BY RIAD SATTOUF DOWNLOAD EBOOK : L'ARABE DU FUTUR - TOME 2 (FRENCH EDITION) BY RIAD SATTOUF PDF

Sea to Sky Geotechnique 2006

Draft - develop and review

Certificate of Completion

THE RELIABILITY OF RADON REDUCTION TECHNIQUES. CB Howarth

Indoor Thermal Environment of Residential Buildings in Three Cities of China

L'ARABE DU FUTUR - TOME 2 (FRENCH EDITION) BY RIAD SATTOUF DOWNLOAD EBOOK : L'ARABE DU FUTUR - TOME 2 (FRENCH EDITION) BY RIAD SATTOUF PDF

BRUNILDA DACI INSTITUTE OF APPLIED NUCLEAR PHYSICS TIRANA-ALBANIA. KOZETA BODE Responsible person for Radon Measurement in Albania

Radon in (Greek) workplaces GREECE

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Smart Radon Detector with Indoor Air Quality Sensors

Smart Radon Detector with Indoor Air Quality Sensors Version 1, May 8, 2018

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

Radon in thermal waters and radon risk in chosen thermal water spas in V4 countries - preliminary results

Kit Instructions COMMON VENT KIT (PVC AND DURAVENT)

Certificate of Completion

This document is a preview generated by EVS

A new personal dosemeter for the individual monitoring of exposure to radon gas

This document is a preview generated by EVS

INSTALLATION INSTRUCTION In-Ground Color Changing

What you need to know

The Effect of Quantity of Salt on the Drying Characteristics of Fresh Noodles

Features and content. This is where air comes into your detector.

Laptop Computer (OLPC)

Experimental Research of Air Source Heat Pump Frosting and Defrosting in a. Double Stage-Coupling Heat Pump

Pennsylvania Citizen s Guide to Radon. Test your home for radon it is easy and inexpensive.

Installation Instructions

Effect of the Dryer Fabric on Energy Consumption in the Drying Section

Abstract. Introduction/Background. New Radon guideline for Canada

Gas Equipment. Volume 1 January/February Issue date: February 4, 2009

Certificate of Completion

Two-Pipe Fiber Bragg grating Temperature Sensor Applied in Cable Trench and Cable Pit

This is a preview - click here to buy the full publication INTERNATIONAL STAN DARD. Radio-frequency connectors

Radon Survey Final Report

Environmental Radiation Monitoring System

On the Natural Fashion in Modern Interior Design

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

K.F. Fong *, C.K. Lee, T.T. Chow

Supporting Information

ScienceDirect. Development progress of critical equipment in the CSNS cryogenic hydrogen system

RADON LAZERWEB SERVICES

Piles subject to excavation-induced soil movement in clay

Evaluation of fixed point H2S gas detectors intended for use in industrial safety applications

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For:

Residential Building Walls and Environment in Amman, Jordan

Transcription:

note technique Spatial variation of radon concentration in a room ZHANG ZHENGGUO*, XIAO DETAO**, ZHANG LIANG*, LI CHUNXIU*, (Manuscrit reçu le 6 octobre 1992) RÉSUMÉ ABSTRACT On a mesuré la concentration en radon en différents endroits à l'intérieur d'une habitation à l'aide de détecteurs CSR solides de traces avec ou sans electret. Les mesures montrent que les concentrations en radon varient à l'intérieur d'une même pièce ; au centre de la pièce, elles diminuent à mesure que s'élève la hauteur audessus du plancher. A une hauteur de 0,88 m {c'est-à-dire la zone de respiration du dormeur), elle est d'environ 1,3-1,5 fois celle mesurée sous le plafond. Elle est la plus élevée à la tête d'un lit situé contre le mur (là où se trouve, généralement, la tête du dormeur), soit 1,6-1,8 fols celle trouvée à 0,5 m sous le planfond. Pour obtenir une évaluation plus réaliste de la dose délivrée aux occupants, estimée selon la concentration moyenne en radon mesurée à 0,5 m sous le plafond, il conviendrait donc de la multiplier par un facteur de correction d'environ 1,5. Radon concentrations were measured at different locations in a house using CSR solid track detectors with and without electret. The results show that radon concentrations differ even in the same room; in the middle of the room, they decrease with increasing height from the floor. Radon concentrations at the height of 0.88 m (i.e. about the breathing height when the resident is sleeping) are about 1.3-1.5 times that at 0.5 m below the ceiling. They are the highest at the head of a bed close to the wall where the sleeper's head usually lies, viz. 1.6-1.8 times that at 0.5 m below the ceiling. The radiation dose to the inhabitants, estimated in accordance with the average radon concentration measured at the 0.5 m location below the celling, should therefore be multiplied by a correction factor of about 1.5 to obtain the realistic dose. 1. Introduction It has been reported that the radiation dose resulting from inhalation of radon daughters accounts for more than 50 % of the total dose from natural radiation [1]. Consequently, radon and its progeny have attracted great attention. In addition to radon exposure of uranium miners, large-scale investigations of indoor radon have been undertaken by many countries. Similar investigations have also been undertaken in China. In the investigation on radon in coal-cinder brick houses, the detectors are usually placed 0.5 m below the ceiling (hung on a thin wire in the middle of the room for convenience of fixation and safety). However, this is not the * Hunan central environmental monitoring station, China, 6 Jing Wan, Changsha 410004, Hunan province, Chine. ** Hengyang institute of technology, China. RADIOPROTECTION - VOL. 28-0033-8451/1993/11/$ 5.00/ Les Editions de Physique 321 Article published by EDP Sciences and available at http://www.radioprotection.org or http://dx.doi.org/10.1051/radiopro/1993014

ZHANG ZHENGGUO et ai. normal position of the occupants of a house. In order to estimate the realistic dose to occupants resulting from radon and its progeny, investigations of spatial variations of radon at different locations within a house are needed. 2. Investigations 2.1 Measurement procedures The main factors affecting indoor distribution of radon are radon sources, building structures, ventilation, etc. In our measurements, the following procedure was adopted. 1) Three kinds of measurements were carried out: a) exposure for 24 h with both the door and window closed, b) exposure for 24 h with both the door and window open, o) exposure for 3 months and then for 1 year under every-day living conditions. 2) Detectors were placed at 5 representatives locations (fig. 1): Location 1: head of the bed, where the sleeper's head usually lies; the detector is placed 0.88 m above the floor and 0.2 m from the wall (dosemeters 1, 2, 3); Location 2: in the middle of the room, 0.88 m above the floor (dosemeters 4, 5, 6); Location 3: in the middle of the room, 1.55 m above the floor (dosemeters 7, 8, 9); Location 4: in the middle of the room, 2.4 m above the floor, i.e. 0.5 m below the ceiling (dosemeters 10, 11, 12); Location 5: 0.70 m from the window and 1.55 m above the floor (dosemeters 13, 14, 15). The bedroom of a coal-cinder brick house is 3.24 m long, 3.2 m wide and 2.97 high. The window is 1.45 m wide and 1.85 high. The door is 0.80 m wide and 1.95 high. As shown in figure 1, the bed (1.43 m wide, 2.1 m long and 0.8 m high) is in the corner of the room. 2.2 Measurement method The 3-month and 1-year cumulative exposures were estimated using CSR solid track detectors [2]. The detector was a new CR-39 (DPA) material-sensitive, uniform and stable with low background noise. A detector sheet (1.75 X 1.75 X 0.22 mm) was placed on the bottom of a diffusion canister (inner diameter: 38 mm and height: 17 mm). The canister was then sealed with a filter. The lower detectable limit was 2.2 Bq rrr 3 when the sampling time was 6 months. The radon concentration was measured with electret [3] exposed for 24 h. The electret was used to establish a static electrical field to increase collection of radon daughters and, therefore, to improve the detector sensitivity. The sampling chamber had a volume of 3.8 I (diameter: 0.18 m, height: 0.13 m). The lower detectable limit was 0.13 Bqnrr 3 when the sampling time was 2 days. 322 RADIOPROTECTION - VOL. 28 - H" 3 (1993)

SPATIAL VARIATION OF RADON CONCENTRATION IN A ROOM Q <1> Bed (2) <2> location 1 143 cm O < 3 > 160 cm location 2,3,4 O O O - H * location 5 210 cm 162 cm O Q G window if O If) 320 cm f 80 cm door 324 cm (a) Top view r 240 cm location 4 <10> <11> <12> location 3 location 5 <7> <8> <9> <13> <14> <15> E o it) 00 297 cm location 1 13 location 2 <4> <5> <6> 55 cm j 88 cm 155 cm (b) Front view Fig, 1. - Distribution of the monitor detectors In the rom Répartition des détecteurs : a) coupe horizontale ; b) coupe verticale RADIOPROTECTION - VOL. 28 - N 3 (1993) 323

ZHANG ZHENGGUO er al 3. Results 3.1 Cumulated exposure lor 24 h * Radon concentrations were measured in the bedroom of a coalcinder brick house from February 5 to 7, 1991. The results are shown in table I, where: 1 _ average radon concentration at location 1 average radon concentration at location 4 Table I shows that: a) the average radon concentration at location 4 was 228 Bq rrr 3 when both the door and window were closed, and 41 Bq - rrr 3 when they were open; b) in both cases, radon concentrations varied with the locations, for instance k was highest, 1.61 and 1.83 respectively with door and window closed or open; c) measurements at locations 2, 3 and 4 indicated that radon concentrations decreased with increasing height from the floor; radon concentrations at location 2 was 30 % higher than at location 4 when both the door and window were closed, and 46 % higher when they were open. The results of measurements carried out on August 17-18, 1991 on the second floor of a red brick laboratory are also given in table I. The results showed that when the door and window were closed, k 2 = 1.27 and k 3 = 1.22, i.e. much the same as in the bedroom of the coal-cinder brick house. TABLE I k t values for a 24 h exposure Valeurs de k pour une exposition de 24 h MmßSOy ßSfeSTjffi e X3jTi ŒD i GjESDD ê onmjû. @ 1 1 61 0.55 1.83 0.72 2 1.27 0.04 1.30 0.34 1.46 0.64 3 1.22 0.02 1.13 0.50 1.34 0.93 4 1.0** 0:01 1.0 0.25 1.0* 039 5 1.57 0.63 0.35 0.14 average 1.32 (N = 5) 0.27 1.20 0.57 * average radon concentration at location 4, when the door and window are closed = 228 ± 56.8 Bq m - 3, and 41 ± 16.1 Bq m - 3 when the door and window are open. ** average radon concentration at location 4, when the door and window are closed = 9.6 ± 0.1 Bq m- 3, 324 RADIOPROTECTION - VOL. 28 - N 3 (1993)

SPATIAL VARIATION OF RADON CONCENTRATION IN A ROOM 3.2 Cumulated exposure for 86 days and 1 year Radon concentrations at representative locations in a bedroom of a red brick five-story building were measured from February 24 to May 20, 1991 and from May 20, 1991 to May 20, 1992 using a CSR solid track detector without electret. The results are given in table II. It can be seen that kj values in the red brick building are similar to values in the coalcinder brick house. TABLE k values for exposure over 86 days and 1 year Valeurs de k, pour une exposition de 86 jours et 1 an II Location Exposure for 86 days Exposure for 1 year mean SD mean SD 1 1.72 1.23 1.53 0.10 2 1.38 0.09 3 1.0* 0.37 1.0** 0.05 * average radon concentration = 25 ± 9.2 Bq m - 3 ** average radon concentration = 15 ± 4.3 Bq rrr 3 3.3 Estimation of the dose-concentration correction factor k c 1) It is clear from our investigation that indoor radon concentrations differ with locations. As the detectors were usually placed at location 4, a correction factor k c1 should be used to obtain the average radon concentration. The average concentration of radon is C a, therefore k c1 is equal to C a divided by C 4, i.e. the average radon concentration at location 4: where k ic and k io are the average values of k over 5 locations when the door and window were closed and open respectively; for coal-cinder brick house, k ic = 1.32, k io = 1.20; t c and t 0 are the daily average times with closed and open doors and windows; according to [4], t c - 11/24, t 0 = 13/24, so k c 1 = 1.3. 2) When in bed, the occupant's head is at location 1 where the radon concentration is shown to be highest. If the dose to occupants is estimated according to the concentration at location 4, then a correction factor k c should be used to obtain the realistic dose. Assuming an indoor occupancy factor of 0.8 [1], an average sleeping time of 8.6 h per day [5], the occupant's exposure to the average radon concentration when staying indoors - except when sleeping: k c = (k 1 c t c + k 1 o t Q ) x 8.6 / (24 X 0.8) + k c1 [1-8.6 / (24 x 0.8)] [2] RADIOPROTECTION - VOL, 28 ~ N 3 (1993) 325

ZHANG ZHENGGUO et al. where k 1 c is the k 1 value when door and window are closed k 1 o is the k 1 value when door and window are open Based on our investigation, k 1 c = 1.61 and k 1 0 = 1.83, then k c = 1.5. 4, Conclusion The investigation demonstrated that radon concentrations at different indoor locations were different ; they decreased with increasing height, and were the highest at the head of the bed (where the occupant's head usually lies when in bed), i.e. 1.6-1.8 times that at 0.5 m below the ceiling. This may be due to the specific gravity of radon (greater than that of air) and to radon exhalation from the wall surface. It can be seen from above that exposure from radon can be lowered if the sleeper's head is kept as far from the wall as possible during sleep. The distribution of radon concentrations is dependent on many factors such as room structure, time distribution of open/shut doors and windows, meteorological parameters, resulting in different k values. This preliminary investigation will be further developed. Acknowledgments : The authors wish to express their gratefulness to Pr Pan Ziqiang, the consultant of our work, for this helpful instruction and to Pr Wang Hengde and Pr Hu Fenquan for their recommendations for improvement REFERENCES [1] UNITED NATIONS SCIENTIFIC COMMITEE ON THE EFFECTS OF ATOMIC RADIATION (UNSCEAR) - Ionizing radiation sources and biological effects. New York : United Nations, 1982. [2] Pan DELING - CSR environmental radon monitor. Nucl. Techn., 1991, 14 (3) 144-149. [3] Tian 2HIHENG - A study of high sensitive radon monitoring method using electret. Nucl. Techn., 1991, 11 <1) 26-32. [4] Zhang ZHENGGUO - Investigation on levels of radon in buildings made of cinder bricks or in mineral regions. Radiât. Prot., 1992, 5 (12) 340-350. [5] JIANGXI CENTRAL ENVIRONMENTAL MONITORING STATION. Investigation on indoor occupancy factor of residents (private communication), 1987. 326 RADIOPROTECTION - VOL. 28 - N 3 (1993)