Installing Water heating battery SAVE VTR 250/300/500

Similar documents
Topvex SF02-SF12 Air Handling Unit

SAVE VTR 250/B. User Manual. Document in original language A001

SAVE VTR 500. Installation and Service. Document in original language A001

Installation and Service

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

SAVE VTC 700. Heat Recovery Ventilation Unit

SAVE VSR 150/B. Installation and Service. Document in original language A001

SAVE VTC 200. Installation and Service. Document in original language A002

Planning guide. Atec.

Topvex SR03, SR04, SR06 Compact Air Handling Unit

SmartDial. Wireless. User Manual. -en_gb language A004. Document in original

MODBUS RS485 TECHNICAL INSTRUCTIONS

Danfoss Air Heating Surfaces

GB Art. Nr

ULTRA LOW TEMPERATURE FREEZER. User Manual

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

INSTALLATION INSTRUCTIONS

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.

INSTALLATION INSTRUCTIONS (CANADA)

Window Kit Installation Instructions

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

VERSO Air Handling Units

2002 Dodge Caravan SE

MEDI-KOOL. Rx CLIMATE CONTROL UNITS INSTALLATION INSTRUCTIONS AND OWNER S MANUAL PRODUCED BY:

Installation and user guide Accumulator tanks

MAKING MODERN LIVING POSSIBLE. Installation Guide. Danfoss Air Units.

TopMaster Air Handling unit. Installation instructions

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

Read this owner's manual thoroughly before operating the appliance and retain it for future reference. TYPE : PORTABLE AIR CONDITIONER

MODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation

Swegon Home Solutions CASA. R2 Smart. Installation, commissioning and maintenance instruction. R2_a_EN-t

S F IT 6" / 8"HES. Quick Installation Guide. franklinwater.eu

Trouble Shooting and Help Guide TT / TTB 1840

ELECTRIC WATER HEATER HT382E55

Service Information. WNes 2956 appliance documentation. Service Information no. 27/2004 LHG/TKD-Fe/June SI

TECH REPORT 200: Use of Water Traps and Drying Filter with the FX-5000 Tension System. Document: Water Trap and Drying Filter Tech Report, Rev. 8.

Installation manual. Tumble dryers T4130. Compass Control

SP1 Wallfire. SP2 Wallfire. SP3 Wallfire. SP8 Wallfire AUS/NZ. 08/19282/2 (AUS & NZ) Issue 2

Sensor Control Panel

Swegon CASA. duct coils for heating. the supply air

Air heater/cooler in combination with ground source heat pump

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

TopMaster Air Handling unit. Technical data

User instructions DHP-AT

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

KitchenAid Food Stream Solutions Classic and Integrated Series

MAIN MENU/HOME SCREEN OVERVIEW

INSTALLATION GUIDE NZ AU

Technical description. Atec.

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

THERMAL SYSTEMS, INC. Installation and Operation Manual

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

O CRC100. Comfort Room Controller (2015/01) en

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

Installation manual Washer extractor

TopMaster Air Handling Unit

User Manual. Dryer Controller M720

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

Convertible radiator valve for one-pipe systems, centre distance 35 mm

AUTOMATIC WASHER MODELS: 7MWTW1805DM0 (White) 01/31/ Whirlpool Corporation Part No. W Rev. A

Elektros montavimo ir eksploatavimo instrukcija 2 Electrical installation and Operation Manual 18 Инструкция по электромонтажу и эксплуатации 34

Instructional & Operating Manual

Liquid-coupled heat exchanger LQRT ECONET

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive

PELLET BURNER PV 350

LQE(E,G,S) Air heater for hot water

COMPACT DRYER GDZ5-1 Training Presentation

AUTOMATIC WASHER HORIZONTAL AXIS. Product Type

B Saneo. Saneo. Saneo BS Saneo CS Saneo BW Saneo CW. C Saneo BLP Saneo CLP. Dometic Dometic. Dometic Dometic. Dometic Dometic.

IntelliDoX Operator Manual

Repair Parts List DISHWASHER MODEL NUMBER MDB6100AWW. When requesting service or ordering parts, always provide the following information:

Blarenberglaan 21 B 2800 MECHELEN Tel.: +32 (0) Fax: +32 (0)

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control.

INSTALLATION MANUAL. Decoration Panel BYCP125K-W1 MODELS

PORTABLE AIR CONDITIONER

Tips. Tips for Successful Vacuum Packaging. Tips on Sealing a Bag. Tips on Removing Air from a Bag. Tips on Storage

DISHWASHER. Models DW820 DW920

Bosch Product Reference Guide. bosch-climate.co.nz

Weekly Testing of Dedicated Smoke Control Dampers - Metasys System Extended Architecture

MODEL GOS40 COMBI/ROTISSERIE OVEN PROGRAM

WARNING VILPRA WOOD WOOD HEATER MANUAL. Marketing: SpaDealers. Korsnäs FINLAND +358 (0)

SonoSelect and SonoSafe energy meters

1. CONDITIONS FOR USE 2. SAFETY

VPS3 Installation Manual

Dryer Controller M720

Feature Summary. I. System

Air Conditioner Features...8 Operating Instruction Care and Cleaning...17 Before You Call...18 Major Appliance Limited Warranty...

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

Added password for IP setup page : Password must be in IP format!

6 Assembling the Blades

FLCH4R Garage and Utility Electric Heater

Weekly Testing of Dedicated Stairwell Pressurization Fans- Metasys System Extended Architecture Code No. LIT

BSR Addressable Fire Detection control panel. Installation operation manual

Corrigo E - User Manual Ventilation

Installation & Maintenance Instructions

MacDonald Steel Limited

Chapter 5 Inspection and maintenance

Swegon Home Solutions CASA. R3 Smart. Installation, commissioning and maintenance instructions. R3_f_EN-t

Transcription:

Installing Water heating battery SAVE VTR 250/300/500 Installation instructions GB Document in original language 211597 A002

Copyright Systemair UAB All rights reserved E&OE Systemair UAB reserves the rights to change their products without notice. This also applies to products already ordered, as long as it does not affect the previously agreed specifications. Systemair is not liable or bound by the warranty if these instructions are not adhered to during installation or service.

Contents 1 Information...1 2 Replace electrical heater with water heating battery...1 2.1 Open the front hatch...1 2.2 Remove the electrical heater...1 2.3 Mount the water heating battery...3 3 Connections...4 3.1 Water system...4 3.2 Actuator for valve control...5 4 Configuration...5

Information 1 1 Information A water heating battery, frost protection sensor (already mounted) and instruction are included in this kit. After unpacking, check the contents. If any part is missing or damaged, please contact your place of purchase. Note: Size and design of the water heating battery are different for each SAVE model. 2 Replace electrical heater with water heating battery 2.1 Open the front hatch Danger Make sure that the Mains supply to the unit is disconnected before performing any maintenance or electrical work! Open the hatch with the two latches and swing the hatch open. SAVE VTR 500: Remove the front hatch by the use of an 8 mm Allen key, after which the hatch is tilted back and lifted off completely. 2.2 Remove the electrical heater 1. Access the electrical connections compartment and electrical heater by removing the cover lid. Number of screws on the cover lid differ for each model. Fig. 1 Remove the lid

2 Replace electrical heater with water heating battery 2. Disconnect the electrical heater (ELH), triac (TRIAC) and overheat protection sensor (OHT) wires from the main circuit board. Fig. 2 Disconnect wires 3. Remove knobs/screws that hold the electrical heater and pull it out. Fig. 3 Remove the electrical heater

Replace electrical heater with water heating battery 3 2.3 Mount the water heating battery Fig. 4 The water heating battery 1. Outlet 2. Inlet 3. Remove plug and add the frost protection sensor. Tread seal the sensor. 4. Drain screw 5. Bleed screw Installation 1. Pull out inner and outer rubber grommets. Fig. 5 Remove grommets 2. Mount the water heater. Be careful not to damage the thin fins on the heater. The water heating battery should be mounted on the brackets at the back of the compartment.

4 Connections Fig. 6 Install the water heating battery 3. Connect the frost protection sensor to any free analog input on the main circuit board. Black wire should be connected to ground (GND), red wire to any analog input (for example AI4). 3 Connections 3.1 Water system When connecting a heater to the water system, the following things should be considered: 1. The connecting pipes from the water heating battery must under no circumstances be subjected to twisting or bending stresses when assembling the pipe, etc. Use suitable tools to counteract the connectors twisting/bending moments during assembly. 2. Ensure that forces due to expansion in the system and the intrinsic weight of the piping system itself do not put loads on to the connecting pipes from the heater. 3. Hot water inlet and outlet should be connected as illustrated in figure 4. The heater contains a bleed screw (5), the air must be properly vented from the system to ensure proper function. A venting valve should normally be installed near the heat exchanger or at the highest point in the system. 4. A drainage screw is connected on the heater figure 4 to empty the system in the event of repair work, a longer operational stop, or when there is a risk of freezing, etc. 5. Immediately after the system has been filled with water, the heater and its connections must be checked for water leaks. Leaks can cause water damage. Operational data: Max. operating temperature: 125 C Max. operating pressure: 0,8 MPa (8 Bar) Important If the water in the water heating battery freezes, then it can burst. If this happens water may leak from the system and cause water damage. If there is a risk of frost the heater must be installed with a circulation pump in a secondary circuit to ensure that a constant flow is achieved in the heater. It's strongly recommended to install an outdoor air damper with a spring return actuator.

Configuration 5 3.2 Actuator for valve control A valve can be installed to control water flow based on heating demand. An actuator have to be installed to control the valve. Table 1 Recommended accessories Valve Name ZTV/ZTR, ZTVB/ZTRB range Article no. Actuator RVAZ4 24A Actuator 0-10V 9862 Transformer PSS48 Transformer 24V 204385 1. Connect actuator to any free ground (GND) connection and analog output (for example AO3) on the connection board. 2. Connect power supply to the actuator. It requires 24 V. Use a transformer. Important Do NOT use 24V DC power output from the connection board for valve actuator. 4 Configuration Control of the water heating battery must be configured at the control panel. Configuration 1. Go to Service menu 2. Enter password (default 1111) 3. Activate the actuator. Go to Components menu, select Heater menu and select type as Water. Choose actuator voltage type. Do advanced settings if necessary. 4. Configure connection of the actuator. Go to Service menu. Select Output menu. In next menu select ANALOG tab. Select the analog output to which the actuator is connected. Example if it is connected to AO3 on the connection board, then select ANALOG OUTPUT 3 and select Y1 Heating from the output type list. 5. Configure frost protection sensor (FPT). Go back to Input menu. Select ANALOG tab. Select the analog input to which the frost protection sensor is connected. Example if it is connected to AI4 on the main circuit board, then select ANA- LOG INPUT 4 and select Frost Protection Temperature Sensor (FPT) from the input type list.

Systemair UAB Linų st. 101 LT 20174 Ukmergė, LITHUANIA Phone +370 340 60165 Fax +370 340 60166 Installing Water heating battery Installation instructions 211597 en_gb 2017-10-24 A002 www.systemair.com