TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

Similar documents
HELKAMA. Optical Fibre Cables

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

Fibre Optic Cable. Catalogue.

Duct Cable GYTS-144B1.3

Ø 1000 * 588 mm 50 kg

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Special Provision No. 683S28 December 2017

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

industry solutions: military

SPECIAL ELECTRICAL AND OPTICAL CABLES

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

Fibre optic media options and trends

Tratos Railway Cables

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

DNVGL-CP-0402 Edition February 2016

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

The Quality Connection. BETAflam Fire Resistant Safety Cables

TECHNICAL REPORT IEC TR Optical fibre cables Guidelines to the installation of optical fibre cables. colour inside. Edition 2.

Fiber Optic Distribution Cables (6-144 Fibers)

Main features of the JETnet system

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

Installation Considerations for Pipelines

BS /1000V XLPE Insulation LSZH Sheath Cables

Caledonian Flame Retardant Coaxial Cables

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

Catalogue Telecommunication Cables INTRODUCCIÓN

High Performance LSZH Fire Resistant Cable

Catalogue Power Cables

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

speed pipe indoor system. Secure indoor networks.

Communication Solutions for Energy Generation, Transmission and Distribution

ITU-T L.63. Safety practice for outdoor installations

Connectors for Optic Fibre Cable

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

PRODUCT CATALOGUE Norröna

Fiber Optic Patch Cord and Pigtails

fire resistant cables

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Flame Retardant Overall Screened Instrumentation Cables (multicore)

FIRE RESISTANT CABLES

Welcome Bucharest! New developments in Duct Solutions and Cable Deployment Techniques

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

Product Catalogue. External Management

ITU-T L.404. Field mountable single-mode optical fibre connectors

Test report for a Teldor Cables SLA-6-01X08- ZAHRH-DD Fibre Optic cable to IEC :1999

Advancing Pipeline Safety

NZQA unit standard version 1 Page 1 of 6. Install, maintain and repair of telecommunications optical fibre network infrastructure

(Notices) EUROPEAN COMMISSION

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

FiberExpress Solutions

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

ALEWIJNSE INTERNATIONAL SWITCHBOARD PRODUCTION

Catalogue. Instrumentation & Control Cables

Cable technology for highest safety requirements

WG Buried Fibre Cable Long Perimeter Detection System

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

LV FIRE RESISTANT CABLES

Caledonian Fire resistant Coaxial Cables

INTERNATIONAL STANDARD

Telecommunication Cables

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Well Services Group. Best in Class BEST IN CLASS

Comtran Cable. Hub-LINK Cables for Transit Applications

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

MT-RJ Optical Fiber System Field Testing

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

SAFE CABLING SYSTEMS IN TUNNELS UNDER FIRE

Copper Connectivity Products

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

Cables and cabling solutions for residential buildings: safety, comfort and environmental-friendliness

Lloyd s Register Type Approval System Test Specification Number 3

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Multi-Core Fire Resistant Cable

Reinforced FBG Sensors Serve Demanding Applications

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Transcription:

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 90 TKF developed from a cable producer to a leading supplier of connectivity solutions located in the Netherlands. A broad range of cables, systems and services enables us to provide our customers worldwide with safe and reliable power and data connections. Due to a focused commitment, TKF is distinguished by specialized application knowledge and solutions with a high degree of reliability, quality and service. Specialized technical know-how and flexibility lead to a high return on investment for our customers. TKF is characterized by continuous investment in customer relations, quality and supplementary services, resulting in sustainable cable solutions and long-term and successful relationships. It goes without saying that we offer our customized solutions with respect for people and environment. Being part of the technology company TKH Group NV, TKF has access to breakthrough solutions, concepts and technologies. More than 85 years of experience Our market segmentation Our core values Building Solutions»» Building»» Energy»» Infrastructure»» Renewable»» Rail infra Industrial Solutions»» Industry»» Marine & offshore»» Oil, gas & petrochemical Telecom Solutions»» Telecom»» Innovativeness»» Maximum reliability»» Outstanding quality»» High service degree»» Corporate Social Responsibility 5

MEET THE TKH GROUP AND ITS CORE TECHNOLOGIES TKH Group NV (TKH) is an internationally operating group of companies specialized in creating and supplying innovative Telecom, Building and Industrial Solutions. All TKH technologies are interlinked into total solutions for these three business segments. Specialists in the fields of marketing, process development, design, engineering and logistics add advice and project implementation to offer a tailor-made solution. TKH aims to carve out strong market positions based mainly on its own advanced technologies and services and on its strong regional and international positioning. The group s growth is concentrated in North-Western, Central and Eastern Europe and in Asia. TKH is known for its innovations and its commitment to renewal. The urge to lead is great. TKH places its experience and knowledge into the service of its clients, and jointly looks for optimal solutions. The four TKH core technologies: Vision & Security Communications Connectivity Manufacturing Systems www.tkhgroup.com 6

CONTENTS TOTAL SOLUTIONS FOR MODERN FIBRE OPTIC NETWORKS 6 Indoor cables Micro Drop Installation Cables flat 0 Micro Drop Installation Cables round STIC Simplex Cables 6 Duplex cables ZIP 8 Breakout cables 0 Distribution-cables Outdoor cables CTC ADSS LTC ADSS-0 6 LTC ADSS-80 8 LTC ADSS-50 0 LTC ADSS-50 DAC CTC 6 LTC-S 8 LTC 0 LTC-S Rodent Protected LTC Rodent Protected LTC Poly-Amide 6 DAC MT 8 CTC CS 50 LTC CS 5 LTC JF MT SWA 5 Universal cables MADC 56 STAC 58 D-DAC LSZH 6 CTC LSZH 6 LTC-S LSZH 65 LTC-S Rodent Protected LSZH 67 CTC HFFR 69 LTC-S HFFR 7 CTC CS LSZH 7 LTC CS LSZH 75 CTC CS HFFR 77 LTC-S CS HFFR 79 CTC CS FR 8 Mini cables Loose Tube Mini Cables 8 Loose Tube Mini Cables 00um 85 Loose Tube Mini Cables PA 87 Central Tube Mini Cables 89 5 Micro cables MUC 9 SFU 9 TECHNICAL PRODUCT INFORMATION 95 TELECOM SOLUTIONS 7 CABLE DRUM SIZES AND WEIGHTS 8 MORE INFORMATION 9 7

TOTAL SOLUTIONS FOR MODERN FIBRE OPTIC NETWORKS The demand for broadband solutions is constantly rising. That means that the number of fibre optic networks is also increasing worldwide. The size and topology of these networks vary by region. Therefore, TKF is constantly innovating in the field of Telecom Solutions. For improved, flexible, cost-saving and easy to install solutions. Our ACE concept As a total solutions supplier within the TKH Group NV, TKF developed the ACE concept, a total solution for modern fibre optic networks. ACE is a certified and guaranteed concept for passive FTTx networks. As a total concept ACE provides the broadband market with a new vision on building fibre optic networks. ACE does not only consist of products, but also guarantees compatibility between all the different components and offers complete, passive solutions. 8

The ACE concept is mainly a success of people. People with knowledge and skills concentrated in the ACE team. Together with our customers we share technical knowledge and help our customers to stay ahead with our continuous developments. ACE not only has the right products, but also ensures that the various components fit together seamlessly in the fields of application: POP, OSP and Subscriber. 9

POP Solutions Building a FTTx network starts at the drawing board where configuration, technology and planning are defined. One of the most challenging parts of the network is the POP (point of presence). This is the centre (heart) of the network where all connections are made and active equipment is installed and operated. It is essential to exclude all possible risks during and operation. TKF has gathered all its experience and know-how within the ACE concept, to cover the full range of options to achieve an optimal POP performance. POP s need to be built close to the subscribers. Moreover they need to fit into this environment and meet the requirements of the subscribers on construction, size, shape, colour, noise and place. TKF has set up a flexible design that meets all demands. A street cabinet solution or a large POP building, they all fit within the ACE concept. The ACE POP solution offers: Flexible design High and super high density ODF Optional SAODF (semi-automated ODF) Third operator solution Partial delivery or turnkey solution OSP Solutions Civil work is the major cost driver (>70%) of the total cost ofownership (TCO), to build FTTx networks. The cost of civil work vary from country to country, sandy or rocky soil and paving: tiles, concrete or no paving at all, make a big difference in cost. Within the ACE concept TKF offers solutions for each OSP network to lower the cost per individual challenge. Direct burial cable solution: Within the ACE concept, TKF has developed a full range of products making the of a direct burial cable concept easy and cost saving. Heavy duty steel or Kevlar protected cables are available together with all components, like closures and access chambers that fit in this application. Modular cabling solution: In order to meet the various demands (success based s) it is often required to use a modular cabling system in FTTx networks. ACE offers a full modular cable solution including all accessories like closures, duct connectors, fibre blowing equipment and a special ODF, for easy of all tubes within the POP or street cabinet. 0

Aerial solution: In case of existing aerial infrastructure (f.i. power lines), it can be cost saving to use this infrastructure to install a FTTx network. ACE offers a full range of ADSS cables suitable for this application. TKF has experience with sewer paths and fibre through gas pipelines. To prevent expensive digging operations, TKF has looked at all the different trenching possibilities, like macro and nano trenching. All these cost saving solutions can be fully integrated within the ACE concept with warranty and certification. All these solutions and options require tailor made products and systems. TKF has developed a total ACE subscriber solution for both single and multi dwelling units (SDU and MDU), that fit all these demands and still keep the cost low. Special indoor and outdoor cables have been developed. And a full series of fibre splice and patch boxes are available in all required sizes and shapes, designed and tested for this challenging environment. Subscriber Solutions The main challenge when building a FTTx network is getting access to the subscriber. As we are operating within the public sector, possible challenges are: Availability of subscribers during office hours Wishes and demands of house and building owners Local regulations and cooperation of all subscribers in the chain: - Are we allowed to install on the outside of the building? - Can we install in hallways, cellars or elevator shafts?

Indoor cables Micro Drop Installation Cables flat Indoor cables Properties The Micro Drop Installation Cable (MDIC) is a special Access cable with low bend radius, no waterpeak G.657.A fibres. Ruggedized construction with excellent performance, easy strippable for fast. This cable solves all in-house problems. Specifications Product group Fibre optic cable Type MDIC LSZH Application Inside Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Cable metal free Strip method Double sided Rip seam Strain relief Material outer sheath LSZH Colour outer sheath White Test procedures IEC 6079-- Longitudinal water blocking No Installation temperature -0 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C UV resistant UV-protection ISO 89/ Max. attenuation @ 0 nm 0. db/km Max. attenuation @ 550 nm 0. db/km Vertical Flame Propagation (for Single Cable) IEC 60--- / EN 5065-- Vertical Flame Spread (for Bunched Cables) IEC 60-- / EN 5066-- (Cat.C)

Indoor cables Micro Drop Installation Cables flat products Part number Dimension (height - width) Net weight (kg/km) radius after radius during short term (Tm) 697 x SM G.657.A.0 /. 0 0 0 50 50 long term (Tl) Indoor cables

Indoor cables Micro Drop Installation Cables round Indoor cables Properties The Micro Drop Installation Cable (MDIC) is a special Access cable with low bend radius, no waterpeak G.657.A fibres. Ruggedized construction with excellent performance, easy strippable for fast. This cable solves all in-house problems. Specifications Product group Fibre optic cable Type MDIC LSZH Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Cable metal free Strip method Double sided Rip seam Strain relief Material outer sheath LSZH Colour outer sheath White Application Inside Test procedures IEC 6079-- Longitudinal water blocking No Installation temperature -0 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C UV resistant UV-protection ISO 89/ Max. attenuation @ 0 nm 0. db/km Max. attenuation @ 550 nm 0. db/km Vertical Flame Propagation (for Single Cable) IEC 60--- / EN 5065-- Vertical Flame Spread (for Bunched Cables) IEC 60-- / EN 5066-- (Cat.C)

Indoor cables Micro Drop Installation Cables round 5 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 6977 x SM G.657.A.7 6 7 56 50 50 6978 x SM G.657.A.7 6 7 56 50 50 6979 6x SM G.657.A.7 6 7 56 50 50 6980 8x SM G.657.A.7 6 7 56 50 50 698 x SM G.657.A.7 6 7 56 50 50 long term (Tl) Indoor cables 5

Indoor cables STIC Indoor cables Properties STIC Soft Tube Indoor Cable This special indoor cable with bend-insensitive fibre G.657.A, protected by easy strippable soft tube, meets all requirements for modern building cabling: a small diameter, low weight, high tensile force and excellent bend and crush performance. Its easy, fast strippable sheath consist of special flame retardant LSZH-material, making the cable extremely robust, but flexible, with its 90 bend radius capability. Consequently, the STIC is perfectly suitable to be installed on the wall by using e.g. staples or glue. Due to its (semi-)dry construction, this cable is highly safe and can be used in any human habitation. The dry soft tube makes also easier its into the vertical riser shafts of MDU s. Specifications Product group Fibre optic cable Type STIC Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Soft tube Cable metal free Strain relief Material outer sheath LSZH Colour outer sheath White Application Inside Suitable for indoor Simulated according IEC 6079-- E7 90 degree bends (R=mm) possible Standardization EN IEC 6079- Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -0 / 50 C Transportation and storage temperature -5 / 60 C Operational temperature range Ta - Tb -0 / 50 C Operational temperature range Ta - Tb -5 / 60 C Max. attenuation @ 0 nm 0. db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0. db/km Halogen free IEC 6075-& / EN 5067--& Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065-- 6

Indoor cables STIC 9 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 79896 x SM G.657.A.9 0 0 6 00 00 79897 x SM G.657.A (x).0 0 0 50 00 00 79898 x SM G.657.A (x).0 0 0 50 00 00 7990 x SM G.657.A (x).9 0 0 50 00 00 79899 6x SM G.657.A (x6).0 0 0 50 00 00 7990 x SM G.657.A.0 0 0 50 00 00 (x6) 79900 x SM G.657.A.0 0 0 50 00 00 (x) 7990 x SM G.657.A. 0 0 50 00 00 (x6) 7990 x SM G.657.A (x).0 0 0 50 00 00 long term (Tl) Indoor cables 7

Indoor cables Simplex Cables Indoor cables Properties The simplex cable consists of one dry-buffered, easy strip low bend radius, no waterpeak G.657.A fibre, tensile elements of aramid yarns and a loose low smoke halogen-free outer jacket. The simplex cable is suitable for direct connector assembly. This cable is suitable for indoor in dry rooms, inside of telecommunication- and datasystems. Specifications Product group Fibre optic cable Type Simplex Application Inside Optical fibre standard ITU-T G.657.A Colour outer sheath Yellow Fibre type Single mode 9/5 Type of tube Product dependent Cable metal free Strain relief Material outer sheath LSZH Standardization EN IEC 6079--50 Test procedures IEC 6079-- Installation temperature -5 / 5 C Transportation and storage temperature Product dependent Operational temperature range Ta - Tb Product dependent Max. attenuation increase during Ta - Tb 0. db Max. attenuation @ 0 nm 0. db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0. db/km Halogen free IEC 6075-& / EN 5067--& Vertical Flame Propagation (for Single Cable) IEC 60--- / EN 5065-- 8

Indoor cables Simplex Cables 5 products Part number 6967 x SM G.657.A. mm 695 x SM G.657.A.6 mm 695 x SM G.657.A.0 mm 695 x SM G.657.A. mm 695 x SM G.657.A.8 mm Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm). 5 0 0 50 0.6 5 0 0 70 0.0 5 0 0 0 0. 5 0 5 60 60.8 5 0 5 00 65 long term (Tl) Indoor cables 9

Indoor cables Duplex cables ZIP Indoor cables Properties The duplex cable consists of simplex cables, parallel laying in a figure 8 design (duplex zip cord). The duplex cable is suitable for direct connector assembly and is used for indoor in dry rooms, inside of telecommunication- and datasystems. Specifications Product group Fibre optic cable Type Duplex Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Product dependent Cable metal free Strain relief Material outer sheath LSZH Colour outer sheath Yellow Application Inside Standardization EN IEC 6079- Test procedures IEC 6079-- Longitudinal water blocking No Radial water blocking No Installation temperature -5 / 5 C Transportation and storage temperature -5 / 70 C Max. attenuation @ 0 nm 0. db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0. db/km Halogen free IEC 6075-& / EN 5067--& Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065-- 0

Indoor cables Duplex cables ZIP products Part number Dimension (height - width) Net weight (kg/km) radius after radius during 6986 ZIP.6 SM G.657.A.6 /. 5 0 0 50 6987 ZIP.0 SM G.657.A.0 /. 8 0 0 00 6988 ZIP.8 SM G.657.A.8 / 5.8 0 56 00 short term (Tm) Indoor cables

Indoor cables Breakout cables Indoor cables Properties The Breakout cable consists of multiple simplex cables stranded around a central support member, with a low smoke halogenfree outer jacket. The individual simplex cables are suitable for direct connector assembly. This cable is suitable for indoor in dry rooms, inside of telecommunication- and datasystems. Specifications Product group Fibre optic cable Type Break-Out Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Simplex.6 Cable metal free Strip method Rip cord Strain relief Material outer sheath LSZH Colour outer sheath Yellow Application Inside Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking No Radial water blocking No Installation temperature -0 / 60 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 60 C Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0.5 db/km Halogen free IEC 6075-& / EN 5067--& Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065--

Indoor cables Breakout cables 6 products Part number 7706 x SM G.657.A.6 mm (x ) 77065 8x SM G.657.A.6 mm (8x ) 77066 x SM G.657.A.6 mm (x ) 7707 6x SM G.657.A.6 mm (6x ) 77067 x SM G.657.A.6 mm (x ) 7707 8x SM G.657.A.6 mm (8x ) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7.6 70 0 50 600 50 9. 8 5 80 800 50. 6 70 0 00 50 0. 0 60 0 000 50.6 90 50 00 50 6.6 0 0 0 000 50 long term (Tl) Indoor cables

Indoor cables Distribution-cables Indoor cables Properties The distribution-cable consists of multiple dry-buffered low bend radius, no waterpeak G.657.A fibres, covered by aramid yarns (strength members), with a low smoke halogen-free outer jacket. The individual fibres are suitable for direct connector assembly. This cable is suitable for indoor in dry rooms, inside of telecommunication- and datasystems. Specifications Product group Fibre optic cable Type Distribution-cable Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Type of tube Dry buffer 0,9mm Cable metal free Strain relief Material outer sheath LSZH Colour outer sheath Yellow Application Inside Standardization EN IEC 6079- Test procedures IEC 6079-- Longitudinal water blocking No Radial water blocking No Installation temperature -5 / 5 C Transportation and storage temperature -5 / 70 C Max. attenuation @ 0 nm 0. db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0. db/km Halogen free IEC 6075-& / EN 5067--& Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065--

Indoor cables Distribution-cables products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 698 x SM G.657.A (x).5 9 5 90 500 00 698 8x SM G.657.A (8x) 5.6 8 55 0 700 00 698 x SM G.657.A 6. 6 65 0 000 00 (x) 698 x SM G.657.A (x) 8. 55 85 70 000 00 long term (Tl) Indoor cables 5

Outdoor cables - Aerial - Metalfree CTC ADSS Outdoor cables Properties The Central Tube Cable All Dielectric Self Supporting Cable (CTC ADSS) is an aerial central tube cable with low bend radius, no waterpeak G.657.A fibres and dry-waterblocking aramid yarns underneath the polyethylene outer sheath. This FttX-cable is intended for use as an aerial customer drop cable. This cable is designed for spans between approx. 0 and 50 mtrs, depending on installing and surroundings conditions, with the conditions from the NESC tables as a basis. For further information, please consult document Sag & Tension Calculations under characteristic Specification. Specifications Product group Fibre optic cable Type CTC ADSS Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath PE (polyethylene) Colour outer sheath Black Application Outside Blowable Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant Max. attenuation @ 0 nm 0. db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0. db/km 6

Outdoor cables - Aerial - Metalfree CTC ADSS 5 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7760 x SM G.657.A 6.6 00 0 50 600 776 x SM G.657.A 6.6 00 0 50 600 776 6x SM G.657.A 6.6 00 0 50 600 776 8x SM G.657.A 6.6 00 0 50 600 776 x SM G.657.A 7. 0 00 5 50 600 long term (Tl) Outdoor cables 7

Outdoor cables - Aerial - Metalfree LTC ADSS-0 Outdoor cables Properties The Loose Tube Cable All Dielectric Self-Supporting (LTC ADSS) is a metalfree aerial distribution cable, with dry waterblocking and aramid yarns under the outersheath. This cable is to be used under all dielectric circumstances, for example on distribution and medium/low voltage power lines, railway, tram, trolley bus lines and between buildings. Because of its strong tensile members it is suitable for aerial applications without using additional strenght members. This cable is designed for spans between approx. 0 and 80 mtrs, depending on installing and surroundings conditions, with the conditions from the NESC tables as a basis. For further information, please consult document Sag & Tension Calculations under characteristic Specification. Specifications Product group Fibre optic cable Type LTC ADSS-0 Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Colour outer sheath Black Application Outside Blowable Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km 8

Outdoor cables - Aerial - Metalfree LTC ADSS-0 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 77950 x SM G.657.A (x) 8. 5 5 65 950 50 77957 8x SM G.657.A (x) 8. 5 5 65 950 50 77958 x SM G.657.A (x) 8. 5 5 65 000 50 77959 x SM G.657.A (x6) 8. 5 5 65 00 500 7795 x SM G.657.A (6x) 8.8 55 0 75 50 550 7795 x SM G.657.A (x6) 8. 55 5 65 00 500 77960 8x SM G.657.A (8x6) 0.0 87 50 00 800 050 7795 8x SM G.657.A 9.5 79 5 90 00 700 (x) 7795 7x SM G.657.A 9.5 8 5 90 500 750 (6x) 77955 96x SM G.657.A. 70 5 00 00 (8x) 77956 x SM G.657.A (x). 76 5 90 50 050 long term (Tl) Outdoor cables 9

Outdoor cables - Aerial - Metalfree LTC ADSS-80 Outdoor cables Properties The Loose Tube Cable All Dielectric Self-Supporting (LTC ADSS) is a metalfree aerial distribution cable, with dry waterblocking and aramid yarns under the outersheath. This cable is to be used under all dielectric circumstances, for example on distribution and high voltage power lines, railway, tram, trolley bus lines and between buildings. Because of its strong tensile members it is suitable for aerial applications without using additional strenght members. This cable is designed for spans between approx. 80 and 60 mtrs, depending on installing and surroundings conditions, with the conditions from the NESC tables as a basis. For further information, please consult document Sag & Tension Calculations under characteristic Specification. Specifications Product group Fibre optic cable Type LTC ADSS-80 Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Colour outer sheath Black Application Outside Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0. db/km 0

Outdoor cables - Aerial - Metalfree LTC ADSS-80 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 77650 x SM G.657.A (6x) 0.6 85 55 0 00 00 7769 x SM G.657.A (x6) 0.8 86 60 5 800 000 7765 x SM G.657.A (6x) 0.7 87 60 0 900 000 7765 x SM G.657.A.6 99 70 0 800 00 (x) 7766 6x SM G.657.A.6 00 70 0 800 00 (x) 7 8x SM G.657.A (6x8).5 0 70 5 000 000 7765 8x SM G.657.A.6 0 70 0 900 00 (x) 7765 7x SM G.657.A.6 0 70 0 5000 00 (6x) 77655 96x SM G.657.A. 95 60 500 700 (8x) 77656 x SM G.657.A 6.5 05 5 0 6500 5800 (x) 77657 x SM G.657.A.5 9 00 65 5000 900 (6x) 77659 9x SM G.657.A 5.5 80 0 05 500 500 (8x) 7766 6x SM G.657.A (9x) 6.5 05 50 0 500 500 long term (Tl) Outdoor cables

Outdoor cables - Aerial - Metalfree LTC ADSS-50 Outdoor cables Properties The Loose Tube Cable All Dielectric Self-Supporting (LTC ADSS) is a metalfree aerial distribution cable, with dry waterblocking and aramid yarns under the outersheath. This cable is to be used under all dielectric circumstances, for example on distribution and high voltage power lines, railway, tram, trolley bus lines and between buildings. Because of its strong tensile members it is suitable for aerial applications without using additional strenght members. This cable is designed for spans between approx. 50 and 00 mtrs, depending on installing and surroundings conditions, with the conditions from the NESC tables as a basis. For further information, please consult document Sag & Tension Calculations under characteristic Specification. Specifications Product group Fibre optic cable Type LTC ADSS-50 Colour outer sheath Black Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Application Outside Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant Max. attenuation @ 0 nm 0.8 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.6 db/km

Outdoor cables - Aerial - Metalfree LTC ADSS-50 9 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 77670 x SM G.657.A (6x). 9 65 0 700 700 7767 x SM G.657.A (6x). 96 65 0 7800 7600 7767 x SM G.657.A. 85 5 9700 8600 (x) 7767 8x SM G.657.A (6x8).0 80 0 7800 7800 7767 8x SM G.657.A. 80 0 900 800 (x) 77675 7x SM G.657.A. 80 0 900 800 (6x) 77676 96x SM G.657.A.7 05 75 9600 8800 (8x) 7798 0x SM G.657.A. 8 95 60 9000 800 (5x) 77677 x SM G.657.A (6x).9 6 0 80 8600 800 long term (Tl) Outdoor cables

Outdoor cables - Aerial - Metalfree LTC ADSS-50 Outdoor cables Properties The Loose Tube Cable All Dielectric Self-Supporting (LTC ADSS) is a metalfree aerial distribution cable, with dry waterblocking and aramid yarns under the outersheath. This cable is to be used under all dielectric circumstances, for example on distribution and high voltage power lines, railway, tram, trolley bus lines and between buildings. Because of its strong tensile members it is suitable for aerial applications without using additional strenght members. This cable is designed for spans between approx. 50 and 50 mtrs, depending on installing and surroundings conditions, with the conditions from the NESC tables as a basis. For further information, please consult document Sag & Tension Calculations under characteristic Specification. Specifications Product group Fibre optic cable Type LTC ADSS-50 Colour outer sheath Black Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath HDPE Application Outside Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant Max. attenuation @ 0 nm 0.8 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.6 db/km

Outdoor cables - Aerial - Metalfree LTC ADSS-50 8 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) long term (Tl) 77680 x SM G.657.A (6x).9 7 05 75 500 500 7768 x SM G.657.A (6x).9 8 05 75 5000 700 7768 x SM G.657.A 5.0 7 5 00 9000 6900 (x) 7768 8x SM G.657.A (6x8).7 65 0 90 500 500 7768 8x SM G.657.A 5.0 7 5 00 8600 6600 (x) 77685 7x SM G.657.A 5.0 7 5 00 8700 6600 (6x) 77686 96x SM G.657.A 6.5 06 5 5 8900 7500 (8x) 77687 x SM G.657.A (6x) 6.7 0 50 5 700 700 Outdoor cables 5

Outdoor cables - Underground - Metalfree DAC Outdoor cables Properties The Direct Access Cable (DAC) is a light-weight, non-metallic, central tube direct-buried Access cable with low bend radius, no waterpeak G.657.A fibres, with small diameter for easy, longitudinally water-protected. This cable has a very high crush resistance and tensile strenght, is fast strippable (over > meter in one stroke). Due to extra strenght-members in the cable outersheath, this central tube design has an improved temperature range. Installation: direct burial application. Also blowable in (mini)tubes over a limited distance. Specifications Product group Fibre optic cable Type DAC Fibre type Single mode 9/5 Optical fibre standard Product dependent Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath Polypropylene Colour outer sheath Orange Application Outside Blowable No Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Radial water blocking No Installation temperature -0 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C UV resistant UV-protection ISO 89/ Max. attenuation @ 0 nm Product dependent Max. attenuation @ 550 nm Product dependent Max. attenuation @ 65 nm Product dependent 6

Outdoor cables - Underground - Metalfree DAC 6 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 75098 x SM G.657.A 5.9 7 5 60 00 60 750 x SM G.657.A 5.9 7 5 60 00 60 750 6x SM G.657.A 5.9 8 5 60 00 60 7506 8x SM G.657.A 5.9 8 5 60 00 60 7507 x SM G.657.A 5.9 8 5 60 00 60 7550 x SM G.657.A 00µm 5.9 8 5 60 00 60 long term (Tl) Outdoor cables 7

Outdoor cables - Underground - Metalfree CTC Outdoor cables Properties The Central Tube Cable (CTC) is a light-weight, non-metallic, central tube outdoor duct cable with small diameter, rodent protected, longitudinal water-protected. Installation: by blowing or pulling, into conduits or on cable trays. Specifications Product group Fibre optic cable Type CTC Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath PE (polyethylene) Colour outer sheath Black Application Outside Blowable Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Radial water blocking No Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant Max. attenuation @ 0 nm 0.8 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km 8

Outdoor cables - Underground - Metalfree CTC products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7506 x SM G.657.A 6.8 00 5 500 500 75095 x SM G.657.A 6.8 00 5 600 500 7507 x SM G.657.A 6.8 00 5 600 500 7508 6x SM G.657.A 6.8 00 5 600 500 7509 8x SM G.657.A 6.8 00 5 600 500 7506 x SM G.657.A 7. 57 0 50 600 500 7506 x SM G.657.A 7.7 6 5 55 500 500 75065 6x SM G.657.A 7.7 6 5 55 500 500 75066 8x SM G.657.A 7.7 6 5 55 500 500 75067 x SM G.657.A 7.7 6 5 55 500 500 75068 x SM G.657.A 8.5 78 5 90 500 500 long term (Tl) Outdoor cables 9

Outdoor cables - Underground - Metalfree LTC-S Outdoor cables Properties The Loose Tube Cable Slim (LTC-S) is a non-metallic, loose tube outdoor duct cable, longitudinal water-protected. Due to its slim design (small diameter and light in weight), this cable is perfectly suitable for in ducts with limited space. Installation: by blowing or pulling, into conduits or on cable trays. Specifications Product group Fibre optic cable Type LTC-S Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Colour outer sheath Black Application Outside Blowable Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km 0

Outdoor cables - Underground - Metalfree LTC-S 6 products Part number 77608 x SM G.657.A (x) 77609 x SM G.657.A (x) 7760 6x SM G.657.A (x) 776 8x SM G.657.A (x) 776 60x SM G.657.A (5x) 776 7x SM G.657.A (6x) 776 8x SM G.657.A (7x) 77775 96x SM G.657.A (8x) 7765 08x SM G.657.A (9x) 7766 0x SM G.657.A (0x) 7767 x SM G.657.A (x) 77777 x SM G.657.A (x) 7777 x SM G.657.A (6x) 7777 9x SM G.657.A (8x) 7777 6x SM G.657.A (9x) 7777 88x SM G.657.A (x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 8. 7 5 65 600 600 8. 7 5 65 600 600 8. 8 5 65 600 600 8. 9 5 65 600 600 8. 50 5 65 600 600 8. 50 5 65 600 600 8.9 6 5 80 000 600 9.8 80 50 00 500 000 0. 88 60 0 700 000.5 99 70 0 700 000.9 80 0 700 000. 0 90 50 700 000 0.7 89 60 5 700 000.5 90 50 000 500. 7 00 65 00 700 6.0 9 0 0 900 700 long term (Tl) Outdoor cables

Outdoor cables - Underground - Metalfree LTC Outdoor cables Properties The Loose Tube Cable (LTC) is a non-metallic, loose tube outdoor duct cable, longitudinal water-protected. Installation: by blowing or pulling, into conduits or on cable trays. Specifications Product group Fibre optic cable Type LTC Application Outside Colour outer sheath Black Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath PE (polyethylene) Blowable Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km

Outdoor cables - Underground - Metalfree LTC products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7500 x SM G.657.A (x) 0 7 50 00 000 500 750 6x SM G.657.A (x) 0 7 50 00 000 500 750 8x SM G.657.A (x) 0 7 50 00 000 500 750 x SM G.657.A (6x) 0 75 50 00 000 500 77 x SM G.657.A (x) 0 7 50 00 000 500 756 x SM G.657.A (x6) 0 7 50 00 000 500 750 x SM G.657.A (6x) 0 76 50 00 000 500 78 x SM G.657.A (x6) 0 7 50 00 000 500 7506 6x SM G.657.A (6x6) 0 76 50 00 000 500 7509 8x SM G.657.A (8x6). 98 70 0 500 500 7508 8x SM G.657.A (6x8) 0.9 9 60 0 500 500 75 7x SM G.657.A (6x) 0.9 9 60 0 500 000 75 96x SM G.657.A (8x).5 8 90 50 000 000 758 x SM G.657.A (x) 5.9 89 0 0 500 000 759 9x SM G.657.A 5. 7 0 05 900 500 ((5+)x) 75 88x SM G.657.A 8.5 55 80 70 000 000 ((9+5)x) 75 8x SM G.657.A 8.6 8 80 70 000 500 ((5+)x) 75 x SM G.657.A 9.5 79 90 90 000 000 ((6+)x) 75 576x SM G.657.A.8 79 0 55 500 000 ((9+5)x) 755 6x SM G.657.A. 60 80 500 000 ((0+6)x) 708 768x SM G.657.A.7 6 70 90 000 500 ((5++6)x) 757 86x SM G.657.A 6. 500 90 50 500 000 ((6++8)x) 709 9x SM G.657.A ((7++8)x) 7.7 50 0 50 000 000 long term (Tl) Outdoor cables

Outdoor cables - Underground - Metalfree LTC-S Rodent Protected Outdoor cables Properties The Loose Tube Cable Slim Rodent-Protected (LTC-S RP) is a nonmetallic, loose tube outdoor duct cable, rodent protected, longitudinal water-protected, with high pulling force. Due to its slim design (small diameter and light in weight), this cable is perfectly suitable for in ducts with limited space. Installation: by blowing or pulling, into conduits or on cable trays. Specifications Product group Fibre optic cable Type LTC-S RP Application Outside Optical fibre standard ITU-T G.657.A Colour outer sheath Black Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Blowable Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km

Outdoor cables - Underground - Metalfree LTC-S Rodent Protected 7 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7780 x SM G.657.A (x) 7.6 7 50 500 50 7780 6x SM G.657.A (x) 7.6 7 50 500 50 77805 8x SM G.657.A (x) 7.6 7 50 500 50 77789 x SM G.657.A (6x) 8.6 58 0 70 500 500 77806 x SM G.657.A (6x) 7.6 8 50 500 50 7777 x SM G.657.A (x) 7.6 7 50 500 50 77800 x SM G.657.A (x6) 7.6 7 50 500 50 77 x SM G.657.A 8.6 55 0 70 500 500 (x) 7778 6x SM G.657.A (x) 7.6 7 50 500 50 7779 x SM G.657.A (6x) 7.6 8 50 500 50 77790 x SM G.657.A (6x) 8.6 57 0 70 500 500 7780 x SM G.657.A (x6) 7.6 8 50 500 50 77750 x SM G.657.A 8.6 55 0 70 500 500 (x) 7780 6x SM G.657.A (6x6) 7.6 9 50 500 50 7775 6x SM G.657.A 8.6 56 0 70 500 500 (x) 77785 8x SM G.657.A (8x6) 9.0 70 5 80 500 00 7778 8x SM G.657.A (6x8) 8.6 58 0 70 500 500 7775 8x SM G.657.A 8.6 57 0 70 500 500 (x) 7775 60x SM G.657.A 8.6 58 0 70 500 500 (5x) 7775 7x SM G.657.A 8.6 59 0 70 500 500 (6x) 77755 96x SM G.657.A 0. 89 55 00 6000 000 (8x) 77756 0x SM G.657.A.5 70 0 6000 000 (0x) 77767 x SM G.657.A.7 90 55 6000 000 (x) 77778 x SM G.657.A. 0 65 0 000 000 (6x) 77779 9x SM G.657.A.0 7 95 60 6000 000 (8x) 77780 6x SM G.657.A.7 5 05 75 6000 500 (9x) 795 88x SM G.657.A (x) 6.5 50 0 7000 000 long term (Tl) Outdoor cables 5

Outdoor cables - Underground - Metalfree LTC Rodent Protected Outdoor cables Properties The Loose Tube Cable Rodent-Protected (LTC RP) is a robust, nonmetallic, loose tube outdoor duct cable, rodent protected, longitudinal water-protected, with high pulling force. Installation: by blowing or pulling, into conduits or on cable trays. Specifications Product group Fibre optic cable Type LTC RP Application Outside Optical fibre standard ITU-T G.657.A Colour outer sheath Black Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Blowable Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km 6

Outdoor cables - Underground - Metalfree LTC Rodent Protected products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 759 6x SM G.657.A (x) 0.5 88 60 5 000 000 7550 8x SM G.657.A (x) 0.5 88 60 5 000 000 755 x SM G.657.A (6x) 0.5 89 60 5 000 000 755 x SM G.657.A (x) 0.5 87 60 0 000 000 755 x SM G.657.A (x6) 0.5 86 60 0 000 000 755 x SM G.657.A (6x) 0.5 9 60 5 500 000 7555 x SM G.657.A (x6) 0.5 88 60 0 000 000 7557 6x SM G.657.A (6x6) 0.5 9 60 0 000 000 7559 8x SM G.657.A (8x6).8 70 0 000 000 7560 8x SM G.657.A (6x8). 0 70 0 900 00 756 60x SM G.657.A (5x). 0 60 5 00 00 756 7x SM G.657.A (6x). 0 70 0 00 00 7565 96x SM G.657.A (8x) 95 60 5000 600 7567 0x SM G.657.A (0x).5 65 0 00 500 00 7569 x SM G.657.A (x) 6. 0 5 0 5500 000 7570 9x SM G.657.A 5.8 8 0 0 500 500 ((5+)x) 757 88x SM G.657.A 9 76 85 80 5000 000 ((9+5)x) 757 8x SM G.657.A 8.9 6 80 80 5000 500 ((5+)x) 757 x SM G.657.A 9.8 95 00 00 650 500 ((6+)x) 7575 576x SM G.657.A. 95 5 65 5000 000 ((9+5)x) 7576 6x SM G.657.A. 60 80 5000 000 ((0+6)x) 7579 768x SM G.657.A 5 7 80 50 5000 500 ((5++6)x) 7580 86x SM G.657.A 7.0 58 00 50 7500 6000 ((6++8)x) 758 9x SM G.657.A ((7++8)x) 7.5 555 5 550 5000 000 long term (Tl) Outdoor cables 7

Outdoor cables - Underground - Metalfree LTC Poly-Amide Outdoor cables Properties The Loose Tube Cable Polyamid (LTC PA) is a non-metallic, loose tube outdoor duct cable, longitudinal water-protected with a polyamid (PA) outersheath (termite-protection). Installation: suitable for duct or direct buried (under condition of clean backfill), by pulling or blowing. Specifications Product group Fibre optic cable Type LTC PA Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath PE / polyamide Colour outer sheath Black Application Outside Blowable Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Termite protected Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km 8

Outdoor cables - Underground - Metalfree LTC Poly-Amide 7 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 775 x SM G.657.A (6x). 00 70 0 500 500 7755 x SM G.657.A (6x). 00 70 0 500 500 7757 6x SM G.657.A (6x6). 0 0 0 500 500 775 8x SM G.657.A.5 99 75 0 900 900 (x) 775 7x SM G.657.A. 8 85 5 500 500 (6x) 7755 96x SM G.657.A 9 0 80 000 000 (8x) 7759 x SM G.657.A (x) 7. 8 60 5 000 000 long term (Tl) Outdoor cables 9

Outdoor cables - Underground - Metallic - Unarmoured DAC MT Outdoor cables Properties The Direct Access Cable Metallic (DAC MT) is a direct-buried metallic Central Tube Cable, with tracking-wire for detection of the cable in the ground. Light-weight, metallic, central tube directburied Access cable with low bend radius, no waterpeak G.657.A fibres, with small diameter for easy, longitudinally water-protected. This cable has a very high crush resistance and tensile strenght, is fast strippable (over > meter in one stroke). Due to extra strenght-members in the cable outersheath, this central tube design has an improved temperature range. Installation: direct burial application. Specifications Product group Fibre optic cable Type DAC MT Optical fibre standard ITU-T G.657.A Colour outer sheath Orange Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free No Strain relief Material outer sheath Polypropylene Application Outside Blowable No Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Radial water blocking No Installation temperature -0 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C UV resistant UV-protection ISO 89/ Max. attenuation @ 0 nm 0.8 db/km Max. attenuation @ 550 nm 0.5 db/km Max. attenuation @ 65 nm 0.8 db/km 50

Outdoor cables - Underground - Metallic - Unarmoured DAC MT products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 75 x SM G.657.A 5.9 8 5 60 00 60 750 x SM G.657.A 5.9 8 5 60 00 60 long term (Tl) Outdoor cables 5

Outdoor cables - Underground - Metallic - Armoured CTC CS Outdoor cables Properties The Central Tube Cable Corrugated Steel (CTC CS) is a metallic, central tube outdoor cable, with longitudinally watertight cablecore, armoured with corrugated steel tape (excellent rodent resistance). Installation: Pulling into conduits, on cable trays or directly buried. Specifications Product group Fibre optic cable Type CTC CS Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free No Strip method Rip cord Strain relief Material outer sheath PE (polyethylene) Colour outer sheath Black Application Outside Test procedures IEC 6079-- Longitudinal water blocking Product dependent Longitudinal watertight construction Super Absorbing Polymer Radial water blocking Installation temperature -5 / 60 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV resistant UV-protection ISO 89/ Rodent resistant Max. attenuation @ 0 nm 0.8 db/km Max. attenuation @ 550 nm 0.5 db/km Max. attenuation @ 65 nm 0.8 db/km 5

Outdoor cables - Underground - Metallic - Armoured CTC CS 0 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7505 x SM G.657.A 8. 85 0 60 000 600 75 6x SM G.657.A 8. 85 0 60 000 600 75 8x SM G.657.A 8. 85 0 60 000 600 75 x SM G.657.A 8. 85 0 60 000 600 755 x SM G.657.A 8.7 95 0 90 000 600 750 x SM G.657.A. 9 80 0 600 500 750 6x SM G.657.A. 7 80 0 600 500 750 8x SM G.657.A. 9 80 0 600 500 750 x SM G.657.A. 9 80 0 600 500 7505 x SM G.657.A.7 55 90 55 600 500 long term (Tl) Outdoor cables 5

Outdoor cables - Underground - Metallic - Armoured LTC CS Outdoor cables Properties The Loose Tube Cable Corrugated Steel (LTC CS) is a metallic loose tube outdoor cable, armoured with corrugated steel tape (excellent rodent resistance), longitudinal water-protected. Installation: Pulling into conduits, on cable trays or directly buried. Specifications Product group Fibre optic cable Type LTC CS Application Outside Colour outer sheath Black Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free No Strip method Rip cords Strain relief Material outer sheath HDPE Blowable Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -5 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -5 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Rodent resistant Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km 5

Outdoor cables - Underground - Metallic - Armoured LTC CS 7 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7898 x SM G.657.A (x6).5 6 70 0 000 800 78 x SM G.657.A (x).6 90 50 700 800 78 8x SM G.657.A (x).5 6 90 50 700 800 785 7x SM G.657.A (6x).5 8 90 50 700 800 78 96x SM G.657.A (8x). 88 5 90 000 000 789 x SM G.657.A 7.6 7 65 50 00 800 (x) 789 88x SM G.657.A ((9+5)x) 8.5 80 70 000 000 long term (Tl) Outdoor cables 55

Outdoor cables - Underwater LTC JF MT SWA Outdoor cables Properties LTC JF MT SWA Heavy duty underwater cable Loose tube cable with armoring of galvanized steel wires for excellent resistance against crush, impact and tensile forces and heavily protected against water ingress, by means of cable jelly filling and aluminium tape. This cable is suitable to be installed in fresh- or saltwater for a water-depth of max. 50m. Installation: in sewer systems, water pressurized tunnels, lake and river crossings or shorelines (coastal application) Specifications Product group Fibre optic cable Type LTC JF MT SWA Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Strip method Rip cord Strain relief Material outer sheath HDPE Colour outer sheath Black Application Outside Standardization EN IEC 6079- Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Jelly Radial water blocking Radial watertight construction Al/PE Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV resistant Rodent resistant Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km 56

Outdoor cables - Underwater LTC JF MT SWA 9 products Part number Construction Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 787 x SM G.657.A (x) 7.7 88 0 0 0000 000 787 x SM G.657.A (6x) 7.7 88 0 0 0000 000 787 8x SM G.657.A (6x8) 8.7 55 5 70 0000 000 7878 8x SM G.657.A (6x8) 9.6 705 00 90 0000 6000 787 7x SM G.657.A (6x) 8.7 555 5 70 0000 000 7875 96x SM G.657.A (8x) 9.6 590 5 90 0000 000 7877 96x SM G.657.A (8x). 880 0 50 0000 6000 789 x SM G.657.A 9.5 590 5 90 0000 000 (6x) 78 88x SM G.657.A (x) 5. 60 5 60 0000 6000 long term (Tl) Outdoor cables 57

Universal cables - Metalfree MADC Universal cables Properties The Mini Aerial Drop Cable (MADC) is a universal metallfree self supporting optical fibre cable, in small design, with low bend radius, no waterpeak G.657.A fibres and dry-waterblocking aramid yarns underneath the LSZH outer sheath. This FttX-cable is intended for in/outdoor use as an aerial customer drop cable, with over short spans. Specifications Product group Fibre optic cable Type MADC Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Cable metal free Strain relief Material outer sheath LSZH Colour outer sheath Black Application Inside/outside Blowable No Standardization EN IEC 6079- Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -0 / 50 C Transportation and storage temperature -0 / 60 C Operational temperature range Ta - Tb -0 / 50 C Operational temperature range Ta - Tb -5 / 60 C UV resistant UV-protection ISO 89/ Max. attenuation @ 0 nm 0. db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0. db/km Halogen free IEC 6075-& / EN 5067--& Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065-- 58

Universal cables - Metalfree MADC 5 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7986 x SM G.657.A.5 5 5 750 50 79865 x SM G.657.A.5 5 5 750 50 799 x SM G.657.A.5 5 5 750 50 7997 8x SM G.657.A.8 0 5 5 750 50 7998 x SM G.657.A.8 5 5 750 50 long term (Tl) Universal cables 59

Universal cables - Metalfree STAC Universal cables Properties STAC Soft Tube Access Cable This special indoor/outdoor drop cable with bend-insensitive fibre G.657.A, protected by easy strippable soft tube, meets all requirements for FTTH access network: a small diameter, low weight, high tensile force and easily strippable features. The STAC is designed to connect the outside branch to customer s termination box without splicing, resulting in reduced -time. This cable consist of a double jacket design, with a 90 bend radius inner subunit (STIC) perfectly suitable for indoor application, a robust outer sheath for outdoor and tensile strength members between both jackets. The outer sheath can be easily removed, when entering the building. Due to its (semi-)dry construction, this cable is highly safe and can be used in any human habitation. The dry soft tube makes also easier its into the vertical riser shafts of MDU s. This multi-purpose cable can be installed by pulling in ducts, on external walls, or aerial between poles. The STAC cable is designed for maximum spans of 50m (or longer, varying per item), according to French Standard NF C - 0A. For further information, please consult document Sag & Tension Calculations under characteristic Specification. Specifications Product group Fibre optic cable Type STAC Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Soft tube Cable metal free Strip method Rip cords Strain relief Material outer sheath PE (polyethylene) Colour outer sheath Black Application Outside Standardization EN IEC 6079- Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -0 / 50 C Transportation and storage temperature -5 / 60 C Operational temperature range Ta - Tb -0 / 50 C Operational temperature range Ta - Tb -5 / 60 C 60

Universal cables - Metalfree STAC UV resistant UV-protection ISO 89/ Max. attenuation @ 0 nm 0. db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0. db/km Halogen free IEC 6075-& / EN 5067--& Universal cables 6

Universal cables Universal cables - Metalfree STAC 9 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 79888 x SM G.657.A 5. 0 60 0 700 00 79889 x SM G.657.A (x) 6.0 0 60 0 700 00 79890 x SM G.657.A (x) 6.0 0 60 0 700 00 799 x SM G.657.A (x) 5. 0 50 0 700 00 7989 6x SM G.657.A (x6) 6.0 0 60 0 700 00 7989 x SM G.657.A 6.0 0 60 0 700 00 (x6) 7989 x SM G.657.A 6.0 0 60 0 700 00 (x) 79895 x SM G.657.A 6. 0 60 0 700 00 (x6) 7989 x SM G.657.A (x) 6.0 0 60 0 700 00 long term (Tl) 6

Universal cables - Metalfree D-DAC LSZH Properties The Dry Direct Access Cable (D-DAC) is a light-weight, nonmetallic, direct-buried customer drop cable for universal applications. This cable is robust, water-protected and has a flame retardant outersheath. The cable has a flexible, easystrippable sheath and small diameter, making it perfectly suitable for indoor routing. The glass-fibres are dry-buffered, for fast and easy stripping and peeling. The D-DAC is suitable for outdoor (directly into the ground, above ground on facades) and indoor (horizontal and vertical cable channels). Especially due to its fully dry design (no jelly), the cable can be applied as riser cable. This cable is intended for connecting homes in high-rise buildings (MDU's) from the last underground distribution-point in the Access network, without any transitionpoints. This product offers a perfect, fast and cost effective solution for Fibre To The Home' connections in MDU s. Universal cables Specifications Product group Fibre optic cable Type D-DAC LSZH Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Cable metal free Strain relief Material outer sheath LSZH Colour outer sheath Black Application Inside/outside Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -0 / 50 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Max. attenuation @ 0 nm 0.8 db/km Max. attenuation @ 550 nm 0.5 db/km Max. attenuation @ 65 nm 0.0 db/km Halogen free IEC 6075-& / EN 5067--& Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065-- 6

Universal cables Universal cables - Metalfree D-DAC LSZH 5 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7569 x SM G.657.A 5.9 0 60 5 000 00 757 x SM G.657.A 5.9 60 5 000 00 757 6x SM G.657.A 5.9 60 5 000 00 757 8x SM G.657.A 5.9 60 5 000 00 757 x SM G.657.A 5.9 60 5 000 00 long term (Tl) 6

Universal cables - Metalfree CTC LSZH Properties The Central Tube Cable Low Smoke Zero Halogen (CTC LSZH) is a light-weight, non-metallic, universal central tube cable (indoor/outdoor) with small diameter, rodent protected, longitudinal water-protected, with Low Smoke Zero Halogen outersheath. Installation: by blowing or pulling, into conduits or on cable trays. Universal cables Specifications Product group Fibre optic cable Type CTC LSZH Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath LSZH Colour outer sheath Black Application Inside/outside Blowable Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Radial water blocking No Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV resistant Max. attenuation @ 0 nm 0.6 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0. db/km Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065-- 65

Universal cables Universal cables - Metalfree CTC LSZH 5 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 75050 x SM G.657.A 7 50 05 0 600 500 7506 6x SM G.657.A 7 5 05 0 600 500 7505 8x SM G.657.A 7 50 05 0 600 500 7505 x SM G.657.A 7 50 05 0 600 500 7505 x SM G.657.A 7.6 59 5 50 600 500 long term (Tl) 66

Universal cables - Metalfree LTC-S LSZH Properties The Loose Tube Cable Slim Low Smoke Zero Halogen (LTC-S LSZH) is a non-metallic, loose tube universal (indoor/outdoor) cable, longitudinal water-protected, with Low Smoke Zero Halogen outersheath. Due to its slim design (small diameter and light in weight), this cable is perfectly suitable for in ducts with limited space. Installation: by blowing or pulling, into conduits or on cable trays. Universal cables Specifications Product group Fibre optic cable Type LTC-S LSZH Colour outer sheath Black Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath LSZH Application Inside/outside Blowable Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065-- 67

Universal cables Universal cables - Metalfree LTC-S LSZH 6 products Part number 77856 x SM G.657.A (x) 77857 x SM G.657.A (x) 77858 6x SM G.657.A (x) 77859 8x SM G.657.A (x) 77860 60x SM G.657.A (5x) 7786 7x SM G.657.A (6x) 7786 8x SM G.657.A (7x) 7786 96x SM G.657.A (8x) 7786 08x SM G.657.A (9x) 77865 0x SM G.657.A (0x) 77866 x SM G.657.A (x) 77867 x SM G.657.A (x) 77868 x SM G.657.A (6x) 77869 9x SM G.657.A (8x) 77870 6x SM G.657.A (9x) 7787 88x SM G.657.A (x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 8.9 60 5 80 500 500 8.9 6 5 80 500 500 8.9 6 5 80 500 500 8.9 6 5 80 500 500 8.9 6 5 80 500 500 8.9 6 5 80 500 500 9.8 8 50 95 000 500 0. 98 60 0 000 000.0 07 65 0 000 000.7 9 80 0 00 000.5 90 50 00 000.9 95 60 500 00. 08 70 5 600 000. 95 60 800 00.9 6 0 80 000 600 6.6 50 5 500 600 long term (Tl) 68

Universal cables - Metalfree LTC-S Rodent Protected LSZH Properties The Loose Tube Cable Slim Rodent-Protected Low Smoke Zero Halogen (LTC-S RP LSZH) is a non-metallic, loose tube universal (indoor/outdoor) duct cable, rodent protected, longitudinal waterprotected, with Low Smoke Zero Halogen outersheath and high pulling force. Due to its slim design (small diameter and light in weight), this cable is perfectly suitable for in ducts with limited space. Installation: by blowing or pulling, into conduits or on cable trays. Universal cables Specifications Product group Fibre optic cable Type LTC-S RP LSZH Application Inside/outside Optical fibre standard ITU-T G.657.A Colour outer sheath Black Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath LSZH Blowable Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV-protection ISO 89/ Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065-- 69

Universal cables Universal cables - Metalfree LTC-S Rodent Protected LSZH products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 77809 x SM G.657.A (x) 8.0 56 0 60 00 00 7780 6x SM G.657.A (x) 8.0 56 0 60 00 00 778 8x SM G.657.A (x) 8.0 57 0 60 00 00 778 x SM G.657.A (6x) 8.0 58 0 60 00 00 778 x SM G.657.A (x) 8.0 56 0 60 00 00 778 x SM G.657.A (x6) 8.0 56 0 60 00 00 7785 x SM G.657.A 9. 69 0 85 00 50 (x) 7786 6x SM G.657.A (x) 8.0 57 0 60 00 00 7787 x SM G.657.A (6x) 8.0 58 0 60 00 00 7788 x SM G.657.A (x6) 8.0 57 0 60 00 00 7789 x SM G.657.A 9. 70 0 85 00 50 (x) 7780 6x SM G.657.A (6x6) 8.0 58 0 60 00 00 778 6x SM G.657.A 9. 70 0 85 00 50 (x) 778 8x SM G.657.A (8x6) 9.5 8 0 90 500 00 778 8x SM G.657.A (6x8) 9. 7 0 85 00 50 778 8x SM G.657.A 9. 7 0 85 00 50 (x) 7785 60x SM G.657.A 9. 7 0 85 00 50 (5x) 7786 7x SM G.657.A 9. 7 0 85 00 50 (6x) 7787 0x SM G.657.A. 85 5 6000 000 (0x) 7788 x SM G.657.A. 5 00 65 6000 000 (x) 7789 x SM G.657.A.7 75 5 900 900 (6x) 7780 9x SM G.657.A.6 60 05 70 6000 000 (8x) 778 6x SM G.657.A. 78 05 75 6000 500 (9x) 77855 88x SM G.657.A (x) 6.9 9 50 0 5500 700 long term (Tl) 70

Universal cables - Metalfree CTC HFFR Properties The Central Tube Cable Halogen Free Flame Retardant (CTC HFFR) is a non-metallic, central tube universal (indoor/outdoor) cable, rodent-protected, longitudinal water-protected, with a Halogen Free Flame Retardant outer sheath. This cable meets the requirements for fire safety, in terms of flammability, smoke emission and toxic fume omission and reduces the risk to which people, equipment and buildings are exposed in the event of fire. Therefore, CTC HFFR-cable is perfectly suitable for in tunnels, subway, ship, rail (trains, stations), public buildings, etc. Installation: by blowing or pulling, into conduits or on cable trays. Universal cables Specifications Product group Fibre optic cable Type CTC HFFR Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath LSZH Colour outer sheath Orange Blowable Test procedures IEC 6079-- Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 60 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV-protection ISO 89/ Rodent resistant Max. attenuation @ 0 nm 0. db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0. db/km Halogen free IEC 6075-& / EN 5067--& Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065-- Vertical Flame Spread (for Bunched Cables) IEC 60--5 / EN 5066--5 (Cat.D) 7

Universal cables Universal cables - Metalfree CTC HFFR products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7576 x SM G.657.A 0. 5 55 05 5000 500 7577 x SM G.657.A 0.5 60 0 5000 500 long term (Tl) 7

Universal cables - Metalfree LTC-S HFFR Properties The Loose Tube Cable Slim Halogen Free Flame Retardant (LTC-S HFFR) is a non-metallic, loose tube universal (indoor/outdoor) cable, rodent-protected, longitudinal water-protected, with a Halogen Free Flame Retardant outer sheath. This cable meets the requirements for fire safety, in terms of flammability, smoke emission and toxic fume omission and reduces the risk to which people, equipment and buildings are exposed in the event of fire. Therefore, LTC-S HFFR-cable is perfectly suitable for in tunnels, subway, ship, rail (trains, stations), public buildings, etc. Installation: by blowing or pulling, into conduits or on cable trays. Universal cables Specifications Product group Fibre optic cable Type LTC-S HFFR Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HFFR Colour outer sheath Orange Application Inside/outside Blowable Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 60 C Transportation and storage temperature -5 / 70 C Operational temperature range Ta - Tb -5 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV resistant UV-protection ISO 89/ Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km Halogen free IEC 6075-/ Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065-- Vertical Flame Spread (for Bunched Cables) IEC 60--5 / EN 5066--5 (Cat.D) 7

Universal cables Universal cables - Metalfree LTC-S HFFR products Part number 7776 x SM G.657.A (x) 7777 6x SM G.657.A (x) 7778 8x SM G.657.A (x) 7779 7x SM G.657.A (6x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm). 70 5 7000 500. 70 5 7000 500. 70 5 7000 500. 9 70 5 7000 500 long term (Tl) 7

Universal cables - Metallic CTC CS LSZH Properties The Central Tube Cable Corrugated Steel Low Smoke Zero Halogen (CTC CS LSZH) is a metallic, universal central tube cable (indoor/outdoor), with longitudinally water-protected cable-core, armoured with corrugated steel tape (excellent rodent resistance), with Low Smoke Zero Halogen outersheath. Installation: Pulling into conduits, on cable trays or directly buried. Universal cables Specifications Product group Fibre optic cable Type CTC CS LSZH Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free No Strip method Product dependent Strain relief Material outer sheath LSZH Colour outer sheath Black Application Inside/outside Test procedures IEC 6079-- Longitudinal water blocking Product dependent Longitudinal watertight construction Super Absorbing Polymer Radial water blocking Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV resistant UV-protection ISO 89/ Rodent resistant Max. attenuation @ 0 nm 0.8 db/km Max. attenuation @ 550 nm 0.5 db/km Max. attenuation @ 65 nm 0.8 db/km Halogen free IEC 6075-& / EN 5067--& Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065-- 75

Universal cables Universal cables - Metallic CTC CS LSZH 0 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 756 x SM G.657.A 8.5 00 0 70 000 600 757 6x SM G.657.A 8.5 00 0 70 000 600 758 8x SM G.657.A 8.5 00 0 70 000 600 759 x SM G.657.A 8.5 00 0 70 000 600 750 x SM G.657.A 9.0 05 0 90 000 600 7557 x SM G.657.A.5 65 85 50 800 00 7558 6x SM G.657.A.5 66 85 50 800 00 7559 8x SM G.657.A.5 65 85 50 800 00 7560 x SM G.657.A.5 65 85 50 800 00 756 x SM G.657.A. 78 95 65 800 00 long term (Tl) 76

Universal cables - Metallic LTC CS LSZH Properties The Loose Tube Cable Corrugated Steel Low Smoke Zero Halogen (LTC CS LSZH) is a metallic loose tube universal (indoor/outdoor) cable, armoured with corrugated steel tape (excellent rodent resistance), with Low Smoke Zero Halogen outersheath and longitudinal water-protected. Installation: Pulling into conduits, on cable trays or directly buried. Universal cables Specifications Product group Fibre optic cable Type LTC CS LSZH Application Inside/outside Colour outer sheath Black Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free No Strip method Rip cords Strain relief Material outer sheath LSZH Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 60 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Rodent resistant Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065-- 77

Universal cables Universal cables - Metallic LTC CS LSZH 5 products Part number 7856 x SM G.657.A (x) 7857 8x SM G.657.A (x) 7858 7x SM G.657.A (6x) 7859 96x SM G.657.A (8x) 7860 x SM G.657.A (x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm).7 55 90 50 700 800.7 58 90 50 700 800.7 60 90 50 700 800. 00 5 90 000 000 7.6 9 65 50 00 800 long term (Tl) 78

Universal cables - Metallic CTC CS HFFR Properties The Central Tube Cable Corrugated Steel Halogen Free Flame Retardant (CTC CS HFFR) is a metallic, central tube universal (indoor/outdoor) cable, longitudinal water-protected, with corrugated steel tape armoring (excellent rodent resistance) and a Halogen Free Flame Retardant outer sheath. This cable meets the requirements for fire safety, in terms of flammability, smoke emission and toxic fume omission and reduces the risk to which people, equipment and buildings are exposed in the event of fire. Therefore, CTC CS HFFR-cable is perfectly suitable for interbuilding and intrabuilding backbones. Installation: pulling into conduits, on cable trays or directly buried. Universal cables Specifications Product group Fibre optic cable Type CTC CS HFFR Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free No Strip method Rip cords Strain relief Material outer sheath HFFR Colour outer sheath Orange Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 60 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV-protection ISO 89/ Rodent resistant Max. attenuation @ 0 nm 0.8 db/km Max. attenuation @ 550 nm 0.5 db/km Max. attenuation @ 65 nm 0.8 db/km Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065-- Vertical Flame Spread (for Bunched Cables) IEC 60-- / EN 5066-- (Cat.A) 79

Universal cables Universal cables - Metallic CTC CS HFFR products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 75 x SM G.657.A. 59 5 85 5000 500 75 x SM G.657.A.8 76 5 85 500 500 long term (Tl) 80

Universal cables - Metallic LTC-S CS HFFR Properties The Loose Tube Cable Slim Corrugated Steel Halogen Free Flame Retardant (LTC-S CS HFFR) is a metallic, loose tube universal (indoor/outdoor) cable, longitudinal waterprotected, with corrugated steel tape armoring (excellent rodent resistance) and a Halogen Free Flame Retardant outer sheath. This cable meets the requirements for fire safety, in terms of flammability, smoke emission and toxic fume omission and reduces the risk to which people, equipment and buildings are exposed in the event of fire. Therefore, LTC CS HFFR-cable is perfectly suitable for interbuilding and intrabuilding backbones. Installation: pulling into conduits, on cable trays or directly buried. Universal cables Specifications Product group Fibre optic cable Type LTC-S CS HFFR Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free No Strip method Rip cords Strain relief Material outer sheath HFFR Colour outer sheath Orange Application Inside/outside Standardization EN IEC 6079--0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 60 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -5 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV-protection ISO 89/ Rodent resistant Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km Halogen free IEC 6075-/ Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065-- Vertical Flame Spread (for Bunched Cables) IEC 60-- / EN 5066-- (Cat.A) 8

Universal cables Universal cables - Metallic LTC-S CS HFFR products Part number 7867 x SM G.657.A (x) 7868 6x SM G.657.A (x) 7869 8x SM G.657.A (x) 7870 7x SM G.657.A (6x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 6.6 5 50 0 8000 000 6.6 5 50 0 8000 000 6.6 50 0 8000 000 6.6 50 0 8000 000 long term (Tl) 8

Universal cables - Metallic CTC CS FR Properties The Central Tube Cable Corrugated Steel Fire Resistant (CTC CS FR) is a fire safety cable with circuit integrity for at least 90 minutes in the event of fire. It s a robust, metallic central tube universal (indoor/outdoor) cable, with fire protective coating, corrugated steel tape armouring (excellent rodent resistance), longitudinal waterprotection and a Halogen Free Flame Retardant outer sheath. This cable meets the requirements for fire safety, ensures datatransmission during and after fire (secured connectivity) and reduces the risk to which people, equipment and buildings are exposed in the event of fire. Therefore, CTC CS FR-cable is perfectly suitable for signal and control circuits in critical infrastructure like tunnels, subway, ship, rail (trains, stations), public buildings, etc. Installation: by pulling, into conduits or on cable trays. Universal cables Specifications Product group Fibre optic cable Type CTC CS FR Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free No Strip method Rip cords Strain relief Material outer sheath HFFR Colour outer sheath Red Standardization EN IEC 6079- Test procedures IEC 6079-- Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV-protection ISO 89/ Rodent resistant Max. attenuation @ 0 nm 0.8 db/km Max. attenuation @ 550 nm 0.5 db/km Max. attenuation @ 65 nm 0.8 db/km Halogen free IEC 6075-& / EN 5067--& Vertical Flame Propagation (for Single Cable) IEC 60-- / EN 5065-- Vertical Flame Spread (for Bunched Cables) IEC 60-- / EN 5066-- (Cat.A) 8

Universal cables Universal cables - Metallic CTC CS FR products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 75 x SM G.657.A 5.6 99 0 0 7000 000 75 x SM G.657.A 6.5 8 0 5 7000 000 long term (Tl) 8

Mini cables Loose Tube Mini Cables Properties The Loose Tube Mini Cable (LTMC) is a non-metallic, longitudinal water-protected fibre optic cable, with reduced outer diameter and low bend radius, no waterpeak G.657.A fibres, suitable for Access or FTTx applications. Installation: blowing into miniducts. Mini cables Specifications Product group Fibre optic cable Type LTMC Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Colour outer sheath Black Application Outside Blowable Standardization EN IEC 6079-5-0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV resistant UV-protection ISO 89/ Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km 85

Mini cables Mini cables Loose Tube Mini Cables 8 products Part number 78 x SM G.657.A (x) 786 x SM G.657.A (x) 78 6x SM G.657.A (x) 785 8x SM G.657.A (x) 78 7x SM G.657.A (6x) 78 96x SM G.657.A (8x) 786 96x SM G.657.A (8x) 78 x SM G.657.A (6x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 6.0 6 90 0 000 50 6.0 7 90 0 000 50 6.0 7 90 0 000 50 6.0 8 90 0 000 50 6.0 9 90 0 000 50 7.0 05 0 500 50 6.5 0 00 0 500 50 7.9 50 0 60 500 500 long term (Tl) 86

Mini cables Loose Tube Mini Cables 00µm Properties The Loose Tube Mini Cable 00µm (LTMC) is a non-metallic, longitudinal water-protected fibre optic cable, with extra reduced cable-diameter by application of low bend radius, no waterpeak G.657.A 00µm fibres. This cable is perfectly suitable for Access or FTTx applications, where high fibre-count cables in smallest tube-diameter are needed. Installation: blowing into miniducts. Mini cables Specifications Product group Fibre optic cable Type LTMC Optical fibre standard ITU-T G.657.A 00 µm Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Colour outer sheath Black Application Outside Blowable Standardization EN IEC 6079-5-0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV resistant Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km 87

Mini cables Mini cables Loose Tube Mini Cables 00µm 0 products Part number 770 x SM G.657.A 00 µm (x) 770 6x SM G.657.A 00 µm (x) 770 8x SM G.657.A 00 µm (x) 779 7x SM G.657.A 00 µm (6x) 7890 96x SM G.657.A 00 µm (8x) 789 x SM G.657.A 00 µm (x) 789 x SM G.657.A 00 µm (6x) 788 9x SM G.657.A 00 µm (8x) 775 6x SM G.657.A 00 µm (9x) 7905 88x SM G.657.A 00 µm (x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 5. 80 05 00 00 5. 80 05 00 00 5. 80 05 00 00 5. 80 05 00 00 6. 5 95 5 000 50 8. 6 5 65 500 500 7.0 05 0 000 00 8. 6 0 60 000 000 8.5 67 0 75 000 000 0.6 99 60 0 000 500 long term (Tl) 88

Mini cables Loose Tube Mini Cables PA 00µm Properties The Loose Tube Mini Cable Polyamide 00µm (LTMC PA) is a nonmetallic, longitudinal water-protected fibre optic cable, with reduced outer diameter and low friction polyamide outer-sheath. This cable is perfectly suitable for Access or FTTx applications, where blowing of mini-cable over long distances in shortest possible time slot is needed. Installation: blowing into mini-ducts. Mini cables Specifications Product group Fibre optic cable Type LTMC PA Optical fibre standard ITU-T G.657.A 00 µm Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath Polyamide Colour outer sheath Black Application Outside Blowable Standardization EN IEC 6079-5-0 Test procedures IEC 6079-- Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant Max. attenuation @ 0 nm 0.5 db/km Max. attenuation @ 550 nm 0. db/km Max. attenuation @ 65 nm 0.5 db/km 89

Mini cables Mini cables Loose Tube Mini Cables PA 00µm 0 products Part number 7708 x SM G.657.A 00 µm (x) 7709 6x SM G.657.A 00 µm (x) 770 8x SM G.657.A 00 µm (x) 77 7x SM G.657.A 00 µm (6x) 777 96x SM G.657.A 00 µm (8x) 778 x SM G.657.A 00 µm (x) 77 x SM G.657.A 00 µm (6x) 770 9x SM G.657.A 00 µm (8x) 77 6x SM G.657.A 00 µm (9x) 779 88x SM G.657.A 00 µm (x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 5. 80 05 00 00 5. 80 05 00 00 5. 80 05 00 00 5. 5 80 05 00 00 6. 5 95 5 000 50 7.9 59 5 65 500 500 6.7 0 00 5 000 00 7.9 6 0 60 000 000 8.5 68 0 75 000 000 0. 96 60 0 000 500 long term (Tl) 90

Mini cables Central Tube Mini Cables Properties The Central Tube Mini Cable (CTMC) is a customer drop cable, consisting of a central tube filled with low bend radius, no waterpeak G.657.A fibres, finished with aramid yarns (as strenght-elements) and a polypropylene outer jacket. This cable has a small outside diameter and is ideal for blowing in microtubes in the Access Network. Installation: blowing into microducts of 5.5 mm. (inside diameter) Mini cables Specifications Product group Fibre optic cable Type CTMC Optical fibre standard Product dependent Colour outer sheath Black Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath Polypropylene Application Outside Blowable Test procedures IEC 6079-- Longitudinal water blocking Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb Product dependent Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb Product dependent UV resistant Max. attenuation @ 0 nm 0.8 db/km Max. attenuation @ 550 nm 0.5 db/km Max. attenuation @ 65 nm 0.8 db/km 9

Mini cables Mini cables Central Tube Mini Cables 6 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 79 x SM G.657.A (x).9 5 55 0 80 790 x SM G.657.A (x).9 5 55 0 80 79 6x SM G.657.A (x6).9 5 55 0 80 797 8x SM G.657.A (x8).9 5 55 0 80 795 x SM G.657.A 00.9 5 55 0 80 µm 79 x SM G.657.A 00 µm.9 5 55 0 80 long term (Tl) 9

Micro cables MUC Properties The Micro Unitube Cable (MUC) is a non-metallic, waterproof customer drop cable, consisting of low bend radius, no waterpeak G.657.A fibres, in a jelly-filled central tube, surrounded by aramid-yarns (as tensile strength elements) and protected by a smooth low-friction outersheath. This outdoor cable is thin, light in weight and flexible and can be installed with narrow bending radii, therefore very suitable for application in the access network. Installation: blowing into microducts. 5 Micro cables Specifications Product group Fibre optic cable Type MUC Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath Product dependent Colour outer sheath Black Application Outside Blowable Standardization EN IEC 6079-5-0 Test procedures IEC 6079-- Longitudinal water blocking Installation temperature -5 / 50 C Transportation and storage temperature -5 / 70 C Operational temperature range Ta - Tb Product dependent Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0. db UV-protection ISO 89/ Max. attenuation @ 0 nm 0.6 db/km Max. attenuation @ 550 nm 0.5 db/km Max. attenuation @ 65 nm 0.5 db/km 9

5 Micro cables Micro cables MUC 9 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during 76 x SM G.657.A.0 0 0 00 76 x SM G.657.A.0 0 0 00 76 6x SM G.657.A.0 0 0 00 768 x SM G.657.A.5 5 0 0 00 769 x SM G.657.A.5 5 0 0 00 767 6x SM G.657.A.5 5 0 0 00 760 8x SM G.657.A.5 5 0 0 00 765 x SM G.657.A.5 5 0 0 50 797 x SM G.657.A.0 7 0 5 50 short term (Tm) 9

Micro cables SFU Properties The Smooth Fibre Unit (SFU) consists of a bundle of low bend radius, no waterpeak G.657.A fibres, encapsuled by a dry acrylate layer and protected by a smooth, slightly ribbed polyethylene outersheath, for application in the access network. Installation: blowing into microducts of.5mm. or.0mm. (inside diameter) 5 Micro cables Specifications Product group Fibre optic cable Type SFU Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Type of tube Central tube Cable metal free Material outer sheath PE (polyethylene) Colour outer sheath Yellow Application Inside/outside Blowable Standardization EN IEC 6079-5-0 Test procedures IEC 6079-- Installation temperature -5 / 50 C Transportation and storage temperature -0 / 50 C Operational temperature range Ta - Tb -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation @ 0 nm 0.0 db/km Max. attenuation @ 550 nm 0.0 db/km 95

5 Micro cables Micro cables SFU 5 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during 50060 x SM G.657.A. 0 0 0 5006 x SM G.657.A. 0 0 0 5006 6x SM G.657.A. 0 0 5 50065 8x SM G.657.A.5 50 50 0 50066 x SM G.657.A.7 50 50 0 short term (Tm) 96

TECHNICAL PRODUCT INFORMATION Cable construction and colour code MDIC LSZH Indoor FO drop cable with easy fibre access. Optical fibres Longitudinal non-metallic strength members Outer sheath (LSZH) Standard colours Fibres Group Blue Yellow 97

TECHNICAL PRODUCT INFORMATION Cable construction and colour code MDIC LSZH (Round) Indoor cable. Optical fibres Longitudinal non-metallic strength members Outer sheath LSZH Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink 98

TECHNICAL PRODUCT INFORMATION Cable construction and colour code STIC Color code acc. to France Telecom Optical fibres Soft tube Strength member (waterblocking aramid yarns) Outer sheath Standard colours Fibres Group Red Blue Green Yellow 5 Violet 6 White 7 Orange 8 Grey 9 Brown 0 Black Turquoise Pink Tubes Layer Red Blue Green Yellow 99

TECHNICAL PRODUCT INFORMATION Cable construction and colour code Simplex Indoor cable. Optical fibres Secondarily protection Strain relief elements (Aramid) Outer sheath (LSZH) Standard colours None 00

TECHNICAL PRODUCT INFORMATION Cable construction and colour code Duplex Optical fibres Secondarily protection Strain relief elements (Aramid) Outer sheath (LSZH) Standard colours None 0

TECHNICAL PRODUCT INFORMATION Cable construction and colour code Break out Central Strength-Element (FRP) Simplex cable (printed numbers) Ripcord Outer sheath (LSZH) Standard colours None 0

TECHNICAL PRODUCT INFORMATION Cable construction and colour code Dist ribut ion cable Optical fibres 900 µm Secondarily protection Strain relief elements (Aramid) Outer sheath (LSZH) Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer 0

TECHNICAL PRODUCT INFORMATION Cable construction and colour code STAC Color code acc. to France Telecom 5 6 7 5 6 7 Optical fibres Soft tube Strength member (waterblocking aramid yarns) Ripcord Inner sheath Strength member (waterblocking aramid yarns) Outer sheath Standard colours Fibres Group Red Blue Green Yellow 5 Violet 6 White 7 Orange 8 Grey 9 Brown 0 Black Turquoise Pink Tubes Layer Red Blue Green Yellow 0

TECHNICAL PRODUCT INFORMATION STAC Catenary Calculations Installation Temperature 5 C NESC Light NESC Medium - C Temperature -0 C 6.5 m/s Wind velocity 7.7 m/s 0 mm Ice thickness 6.5 mm Max. Sag (%) 50 580,00 Based on the following conditions Nominal Sag % The STAC cables are suitable for the NESC-situations with spans, tensions and sags as listed in the table below. Fibre Count Tubes & Fibres x x x 6 x 6 x Temperature Wind velocity Ice thickness Max. Span Max. Tension n x m (m) (kn) x x 6 x 80 700 NESC Heavy Temperature -0 C Wind velocity 7.7 m/s Ice thickness.5 mm Max. Max. Max. Max. Max. Span Tension Sag Span Tension (m) (kn) (%) (m) (kn),0 5 66,57 8 665,7 60 67, 5 69,55 8 689,7 5 700,5 8 697,68 x 6 50 59,0 5 700,55 8 695,7 Table: Operational conditions, max. achievable span, tension and sag. Max. Sag (%) According to NF C -0A (* Temperature -5 C, ice thickness of 5mm and wind speed 80km/h) the STAC cables are suitable for maximum spans as listed in the table below Fibre count 6 Tubes Span Installation (5 C) Maximum conditions* & nom sag nom tension vect. sag Max tension Fibres n x m m % N % N x 80,0 05,87 565 x 50,0 90,60 50 x 60,0 95,67 506 x 80,0 05,87 565 x 6 50,0 90,60 50 x 50,0 90,60 50 x 6 60,0 95,67 506 x 60,0 95,67 506 x 6 55,0 00,66 500 05

TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC ADSS FO cable with central tube. Outdoor application. Aerial fibre-optic drop cable. Optical fibres Central tube, gel-filled Reinforcement of aramid yarns Outer sheath (PE) Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 0 Turquoise Black Orange Pink 06

TECHNICAL PRODUCT INFORMATION CTC ADSS Catenary Calculations Fibre count Installation Tension Installed Sag Max. Span Max. Tension Tm Max. Sag Cable & Fibre Strain NESC-Light NESC-Medium NESC-Heavy max. 8 max. 8 max. 8 8 N 77 N N 58 N 0 N 8 N % % % % % % 0 m 00 m 57 m 5 m m m 50 N 50 N 50 N 50 N 50 N 50 N.7%.5%.0%.9%.%.% 0.50% 0.8% 0.9% 0.7% 0.8% 0.6% Fibre count max. 8 max. 8 max. 8 Installation Tension 67 N 86 N N 8 N 7 N 8 N Installed Sag % % % % % % Max. Span m 0 m 6 m 6 m 6 m m Max. Tension Tm 50 N 50 N 50 N 50 N 50 N 50 N Max. Sag.%.%.6%.5%.6%.5% Cable & Fibre Strain 0.50% 0.8% 0.9% 0.8% 0.8% 0.6% Fibre count max. 8 max. 8 max. 8 Installation Tension 0 N 0 N 98 N Installed Sag % % N 5 N 6 N % % % % Max. Span 9 m 7 m 7 m 69 m 0 m 8 m Max. Tension Tm 50 N 50 N 50 N 50 N Cable & Fibre Strain 0.50% 0.8% 0.9% 0.7% 50 N 50 N Max. Sag 5.0%.9% 5.% 5.% 5.% 5.% 0.8% 0.6% Wind velocity Ice thickness Additional load Temperature Units m/s km/h mps mm inch kg/m lbs/ft ºC NESC-Light NESC-Medium NESC-Heavy 6.5 7.7 7.7 95 6 6 59 0 0 0 6.5.5 0 0.5 0.50 0.07 0.96 0.9 0.05 0.0 0.0 - -0-0 ºF 0 5 0 07

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC ADSS 0 All-dielectric self-supporting cable. FO cable with stranded loose tubes. 5 6 7 8 Centre element, FRP Optical fibres Sub units &5 Binders & Waterblocking tape 6 7 8 Waterblocking Aramide Ripcord Outer sheath Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink Tubes Layer Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Orange 0 Black Pink Turquoise 08

TECHNICAL PRODUCT INFORMATION LTC ADSS 0 Catenary Calculations based on the following conditions Installation Temperature 5 C Nominal Sag % The cables are suitable for the NESC-situations with spans, tensions and sags as listed in the table below. Fibre Count Tubes & Fibres NESC Light NESC Medium NESC Heavy Temperature - C Temperature -0 C Temperature -0 C Wind velocity 6.5 m/s Wind velocity 7.7 m/s Wind velocity 7.7 m/s Ice thickness 0 mm Ice thickness 6.5 mm Ice thickness.5 mm Span n x m (m) (N) x 80 70 8 x 80 60 Max. Max. Tension x 80 70 6 x 80 90 x 6 80 0 x 6 8 8 x 6 8 x 7 6 x 78 0 85 85 78 550 80 600 96 8 x 80 000 Max. Sag (%).0..0.05.6..97.09.07.8 Max. Max. Max. Max. Max. Span Tension Sag Span 0.5 0 8 0.5 0 Tension Max. Sag (m) (N) (%) (m) (N) (%) 8 95.66 8 0.7 0 90.68 50 00.68 0 60 60. 0 95.67 50 80.5 0 50.6 0.87 8 60.6 0 0.88 60 955. 0 090.75 5 650.8 75.7 5 690.6 5 800.7 00.5 x 85 95.59 70 5.9 50 70. Table: Operational conditions, max. achievable span, tension and sag. 09

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC ADSS / -80 / -50 All-dielectric self-supporting cable. FO cable with stranded loose tubes. 5 6 7 8 Centre element, FRP Optical fibres Sub units (,, 6, 8, or fibres) &5 Binders & Waterblocking tape 6 Waterblocking Aramide 7 Ripcord 8 Outer sheath Standard colours Fibres Tubes Group Group Layer Layer Red Red +t Red Red Green Green +t Green Green Blue 5 Blue +t Blue Blue Yellow 6 Yellow +t Yellow Yellow 5 White 7 White +t 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 9 Turquoise Turquoise +t 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink +t Turquoise Turquoise note +t: indicates a black tracer 0

TECHNICAL PRODUCT INFORMATION LTC ADSS 80 Catenary Calculations Installation Temperature Nominal Sag % The cables are suitable for the NESC-situations with spans, tensions and sags as listed in the table below. Fibre Count 6 8 Tubes & Fibres NESC Light NESC Medium NESC Heavy Temperature - C Temperature -0 C Temperature -0 C Wind velocity 6.5 m/s Wind velocity 7.7 m/s Wind velocity 7.7 m/s Ice thickness 0 mm Ice thickness 6.5 mm Ice thickness.5 mm Max. Span Max. 5 C Tension n x m (m) (kn) 6 x 90.5 6 x 5.0 8 x 85. 6 x 6 00.0 x 8 90.9 6 x 8 x 8 x 7 6 x 95. 80.9 85. 85. 96 8 x 70.5 x 55 5.6 6 x 00 5. Max. Sag (%).7.6..5.6.5.....8. Max. Max. Max. Max. Max. Span Based on the following conditions Tension Span.5. 80 5..0 85 5.8. 85 0..8 80.0. 0.5.6 85 50 5..6 00 Tension.0. 5.9.9 85.0..8.6 0.0. 90..5 0.0.9 80.9. 0.0.8 80.9..5. 5 5.5. 85 5.5.7 9 6 8 x 9 x 55 70 5. 6..9.8 5 0 5. 6... 85 95 5. 6..8.7 Table: Operational conditions, max. achievable span, tension and sag. Sag 5. Max. Sag (m) (kn) (%) (m) (kn) (%) 0.5.6 50.0. 90.9.6.

TECHNICAL PRODUCT INFORMATION LTC ADSS 50 Catenary Calculations A. NESC - tables Wind velocity Ice thickness Additional load Temperature Units Light Medium Heavy m/s 6.5 7.7 7.7 km/h 95 6 6 mph 59 0 0 mm 0 6.5.5 inch 0 0.5 0.5 kg/m 0.07 0.96 0.9 lbs/ft 0.05 0. 0. ºC - -0-0 ºF 0 5 0 B. NESC Light Fibre Tubes Max. Installation Operation NESC Light Count & Span Nom. Nom. Nom. Vect. Max. Max. Fibres Sag Tension CS Sag Tension CS n x m (m) (%) (N) (%) (%) (N) (%) 6x.0 7 0.5.5 656 0.80 6x 5.0 89 0.9. 678 0.78 x 8.0 0.5. 75 0.7 x8.0 08 0.5. 695 0.80 6 6x6 5.0 09 0.. 79 0.66 8 6x8.0 6 0.5. 7056 0.80 8 x.0 75 0.6. 78 0.7 7 6x.0 90 0.7. 7 0.7 96 8x 87.0 507 0.5. 795 0.7 8x 7.0 90 0.55. 76 0.78 C. NESC Medium Fibre Tubes Max. Installation Operation NESC Medium Count & Span Nom. Nom. Nom. Vect. Max. Max. Fibres Sag Tension CS Sag Tension CS n x m (m) (%) (N) (%) (%) (N) 6x.0 705 0.9.0 660 0.80 6x 5.0 769 0.8.0 680 0.78 x 7.0 9 0.6.7 76 0.7 x8.0 07 0..9 709 0.80 6 6x6 5.0 97 0..7 789 0.66 8 6x8.0 59 0..9 76 0.80 8 x.0 76 0.7.7 7 0.7 7 6x.0 75 0.7.7 75 0.7 96 8x 7.0 98 0..6 8 0.7 6x 9.0 9 0.6.6 7779 0.78 (%)

TECHNICAL PRODUCT INFORMATION LTC ADSS 50 Catenary Calculations D. NESC Heavy Fibre Tubes Max. Installation Operation NESC Heavy Count & Span Nom. Nom. Nom. Vect. Max. Max. Fibres Sag Tension CS Sag Tension CS n x m (m) (%) (N) (%) (%) (N) (%) 6x 50.0 79 0.9.5 6755 0.80 6x 50.0 767 0.8. 6897 0.77 x 50.0 0 0.6. 758 0.70 x8 50.0 970 0.0. 7079 0.79 6 6x6 50.0 896 0.. 755 0.66 8 6x8 50.0 05 0.0. 757 0.78 8 x 50.0 06 0.7. 756 0.7 7 6x 50.0 7 0.7. 7576 0.7 96 8x 50.0 70 0.. 869 0.7 6x 50.0 688 0.. 798 0.78

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC ADSS 50 FO cable with stranded loose tubes. 5 6 7 8 5 6 7 8 Centre element, FRP Loose tube with optical fibres Water blocking yarns or tape Swellable tape Ripcord Inner PE sheath Water blocking Aramide Outer sheath Standard colours Fibres Tubes Group Group Layer Layer Red Red +t Red Red Green Green +t Green Green Blue 5 Blue +t Blue Blue Yellow 6 Yellow +t Yellow Yellow 5 White 7 White +t 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 9 Turquoise Turquoise +t 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink +t Turquoise Turquoise note +t: indicates a black tracer

TECHNICAL PRODUCT INFORMATION LTC ADSS 50 Catenary Calculations A. NESC - tables Wind velocity Ice thickness Additional load Temperature Units Light Medium Heavy m/s 6.5 7.7 7.7 km/h 95 65 6 mph 59 0 0 mm 0 6.5.5 inch 0 0.5 0.5 kg/m 0.07 0.96 0.9 lbs/ft 0.05 0. 0. ºC - -0-0 ºF 0 5 0 B. NESC Light Fibre Tubes Max. Installation Operation NESC Light Count & Span Nom. Nom. Nom. Vect. Max. Max. Fibres Sag Tension CS Sag Tension CS n x m (m) (%) (N) (%) (%) (N) (%) 6x 69.0 86 0.56. 98 0.80 6x 65.0 850 0.55. 995 0.78 x 55.0 9550 0.50.9 5 0.70 x8 5.0 8968 0.57. 77 0.80 6 6x6 6.0 96 0.6.9 5 0.66 8 6x8 50.0 969 0.58.0 58 0.80 8 x 5.0 99 0.50.9 0 0.70 7 6x 6.0 955 0.50.9 0.70 96 8x 9.0 065 0.55.8 500 0.7 6x 0.0 068 0.58.8 99 0.77 C. NESC Medium Fibre Tubes Max. Installation Operation NESC Medium Count & Span Nom. Nom. Nom. Vect. Max. Max. Fibres Sag Tension CS Sag Tension CS n x m (m) (%) (N) (%) (%) (N) 6x 7.0 669 0.6.7 08 0.80 6x 65.0 6675 0.5.6 05 0.77 x 65.0 776 0.. 55 0.70 x8 6.0 78 0.8.6 90 0.80 6 6x6 67.0 7 0.9. 6 0.66 8 6x8 6.0 76 0.9.6 68 0.80 8 x 6.0 76 0.. 76 0.70 7 6x 6.0 770 0.. 56 0.70 96 8x 5.0 89 0.7. 50 0.7 6x 6.0 896 0.5. 50 0.77 (%) 5

TECHNICAL PRODUCT INFORMATION LTC ADSS 50 Catenary Calculations D. NESC Heavy Fibre Tubes Max. Installation Operation NESC Heavy Count & Span Nom. Nom. Nom. Vect. Max. Max. Fibres Sag Tension CS Sag Tension CS n x m (m) (%) (N) (%) (%) (N) (%) 6x 5.0 57 0.5. 86 0.80 6x 50.0 57 0.. 66 0.78 x 50.0 57 0..9 68 0.70 x8 50.0 97 0.6. 60 0.80 6 6x6 50.0 506 0.9.8 88 0.66 8 6x8 50.0 509 0.6. 75 0.80 8 x 50.0 578 0..9 6 0.7 7 6x 50.0 59 0..9 676 0.7 96 8x 50.0 65 0.7.9 56 0.7 6x 50.0 67 0.9.9 59 0.78 6

TECHNICAL PRODUCT INFORMATION Cable construction and colour code DAC FO cable with central tube. Embedded strength members. PP outer sheath. 5 5 Optical fibres Central Tube Reinforcement Rigid Elements Polypropylene outer sheath Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer 7

TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC FO cable with central tube. Optical fibres Central tube with,, 6, 8,, 6 or fibres Reinforcement of glass yarns Outer sheath (PE) Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer 8

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC-S FO cable with stranded loose tubes. 5 6 7 5 6 7 Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler Water blocking tape Ripcord (optional) Outer sheath (PE) Standard colours Fibres Tubes Group Group Layer Layer Layer Red Red +t Red Red Red Green Green +t Green Green Green Blue 5 Blue +t Blue Blue Blue Yellow 6 Yellow +t Yellow Yellow Yellow 5 White 7 White +t 5 White 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 8 Violet 9 Turquoise Turquoise +t 9 Orange 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink Pink +t Turquoise Turquoise Turquoise Red Red note +t: indicates a black tracer Green Green 5 Blue 5 Blue 6 Yellow 6 Yellow 9

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC FO cable with stranded loose tubes. 5 6 7 5 6 7 Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler Water blocking tape Ripcord (optional) Outer sheath (PE) Standard colours Fibres Tubes Group Group Layer Layer Layer Red Red +t Red Red Red Green Green +t Green Green Green Blue 5 Blue +t Blue Blue Blue Yellow 6 Yellow +t Yellow Yellow Yellow 5 White 7 White +t 5 White 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 8 Violet 9 Turquoise Turquoise +t 9 Orange 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink Pink +t Turquoise Turquoise Turquoise Red Red note +t: indicates a black tracer Green Green 5 Blue 5 Blue 6 Yellow 6 Yellow 0

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC RP FO cable with stranded loose tubes. Rodent Protection. 5 6 7 8 5 6 7 8 Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler Water blocking tape Glass yarn strength members (Rodent Protection) Ripcord (optional) Outer sheath (PE) Standard colours Fibres Tubes Group Group Layer Layer Layer Red Red +t Red Red Green Green +t Green Green Green Blue 5 Blue +t Blue Blue Blue Yellow 6 Yellow +t Yellow Yellow Yellow 5 White 7 White +t 5 White 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 8 9 Turquoise Turquoise +t 9 Orange 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink Pink +t Turquoise Turquoise Turquoise note +t: indicates a black tracer Red Green 5 Blue 5 6 Yellow 6 Red Violet Red Green Blue Yellow

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC PA FO cable with stranded loose tubes. PE Sheath with PA skin. 5 6 7 8 5 6 7 8 Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler Water blocking tape Ripcord (optional) Inner sheath (PE) Outer sheath (PA skin) Standard colours Fibres Tubes Group Group Layer Layer Layer Red Red +t Red Red Green Green +t Green Green Green Blue 5 Blue +t Blue Blue Blue Yellow 6 Yellow +t Yellow Yellow Yellow 5 White 7 White +t 5 White 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 8 9 Turquoise Turquoise +t 9 Orange 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink Pink +t Turquoise Turquoise Turquoise note +t: indicates a black tracer Red Green 5 Blue 5 6 Yellow 6 Red Violet Red Green Blue Yellow

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC-S RP FO cable with stranded loose tubes. Rodent protection. 5 6 7 8 5 6 7 8 Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler Water blocking tape Glass yarn strength members (Rodent Protection) Ripcord (optional) Outer sheath (PE) Standard colours Fibres Tubes Group Group Layer Red Red +t Red Green Green +t Green Blue 5 Blue +t Blue Yellow 6 Yellow +t Yellow 5 White 7 White +t 5 White 6 Grey 8 Grey +t 6 Grey 7 Brown 9 Brown +t 7 Brown 8 Violet 0 Violet +t 8 Violet 9 Turquoise Turquoise +t 9 Orange 0 Black Natural 0 Black Orange Orange +t Pink Pink Pink +t Turquoise note +t: indicates a black tracer

TECHNICAL PRODUCT INFORMATION Cable construction and colour code DAC MT FO cable with central tube. Embedded strength members. PP outer sheath. 5 6 5 6 Optical fibres Central Tube Reinforcement Rigid Elements Steel-wire Polypropylene outer sheath Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink

TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC CS FO cable with central tube. Corrugated steel tape protection. 5 6 7 5 6 7 Optical fibres Central tube with,, 6, 8,, 6 or fibres Reinforcement of glass yarns Inner sheath (PE) (Optional) Ripcord Rodent protection Outer sheath (PE) Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer 5

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC CS FO cable with stranded loose tubes. Corrugated Steel protection. 5 6 7 8 9 0 Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape (optional jelly filling) Filler Water blocking tape (optional jelly filling) Glass yarn strength members (optional) Ripcord (optional) Inner sheath (PE) (optional) Corrugated steel Outer sheath (HDPE) 5 6 7 8 9 0 6 Standard colours Fibres Tubes Group Group Layer Layer Layer Red Red +t Red Red Red Green Green +t Green Green Green Blue 5 Blue +t Blue Blue Blue Yellow 6 Yellow +t Yellow Yellow Yellow 5 White 7 White +t 5 White 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 8 Violet 9 Turquoise Turquoise +t 9 Orange 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink Pink +t Turquoise Turquoise Turquoise note +t: indicates a black tracer Red Red Green Green 5 Blue 5 Blue 6 Yellow 6 Yellow

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC JF MT SWA 5 6 7 8 5 6 7 8 Centre element, FRP Loose tube with optical fibres Jelly filling Aluminium tape Ripcord Inner PE sheath Steel wire armouring Outer sheath Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink Tubes Layer Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 7

TECHNICAL PRODUCT INFORMATION Cable construction and colour code MADC Mini Aerial Drop Cable. Optical fibres Water blocking aramid yarns Outer sheath (LSZH) Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink 8

TECHNICAL PRODUCT INFORMATION MADC Catenary Calculations A. NESC - tables Units m/s Wind velocity km/h mph Ice thickness mm inch Temperature ºC ºF Light Medium Heavy 6.5 7.7 7.7 95 6 6 59 0 0 0 6.5.5 0 0.5 0.5 - -0-0 0 5 0 B. NESC Light # fibres Span Installation Nom. Sag Nom. Tension (m) % (N) - 50.0 70.0 56-00.0 5 NESC Light Vect. Sag Max. Tension (%) (N).7 579-50.5 0. 7 C. NESC Medium # fibres Span Installation Nom. Sag Nom. Tension (m) % (N) - 50.0 70 NESC Light Vect. Sag Max. Tension (%) (N). 7 D. NESC Heavy # fibres Span Installation NESC Light Nom. Nom. Sag Tension Vect. Max. Sag (m) % (N) (%) - 6.0 8.58 Tension (N) 75 9

TECHNICAL PRODUCT INFORMATION Cable construction and colour code D-DAC LSZH 5 6 5 6 Optical fibres Swelling yarn Buffer tube Reinforcement Rigid Elements Outer sheath Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink 0

TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC LSZH FO cable with central tube. Indoor/Outdoor application. Optical fibres Central tube with,, 6, 8,, 6 or fibres Reinforcement of glass yarns Outer sheath (LSZH) Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC-S LSZH FO cable with stranded loose tubes. Indoor / Outdoor application. 5 6 7 5 6 7 Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler Water blocking tape Ripcord Outer sheath (LSZH) Standard colours Fibres Tubes Group Group Layer Red Red +t Red Green Green +t Green Blue 5 Blue +t Blue Yellow 6 Yellow +t Yellow 5 White 7 White +t 5 White 6 Grey 8 Grey +t 6 Grey 7 Brown 9 Brown +t 7 Brown 8 Violet 0 Violet +t 8 Violet 9 Turquoise Turquoise +t 9 Orange 0 Black Natural 0 Black Orange Orange +t Pink Pink Pink +t Turquoise note +t: indicates a black tracer

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC-S RP LSZH FO cable with stranded loose tubes. FO cable with stranded loose tubes. 5 6 7 8 5 6 7 8 Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler Water blocking tape Glass yarn strength members (Rodent Protection) Ripcord (optional) Outer sheath (LSZH) Standard colours Fibres Tubes Group Group Layer Red Red +t Red Green Green +t Green Blue 5 Blue +t Blue Yellow 6 Yellow +t Yellow 5 White 7 White +t 5 White 6 Grey 8 Grey +t 6 Grey 7 Brown 9 Brown +t 7 Brown 8 Violet 0 Violet +t 8 Violet 9 Turquoise Turquoise +t 9 Orange 0 Black Natural 0 Black Orange Orange +t Pink Pink Pink +t Turquoise note +t: indicates a black tracer

TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC HFFR Fire resistant FO cable with central tube. Optical fibres Central tube with,, 6, 8,, 6 or fibres Reinforcement of glass yarns Outer sheath Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC-S HFFR FO cable with stranded loose tubes 5 6 7 5 6 7 Centre element, FRP optional with over sheath Loose tube with optical fibres Water blocking yarns or tape Water blocking tape Glass yarn strength members (rodent protection) Ripcord Outer sheath Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink Tubes Layer Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Orange 0 Black Pink Turquoise 5

TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC CS LSZH FO cable with central tube. Corrugated steel tape protection. 5 6 7 5 6 7 Optical fibres Central tube with fibres Reinforcement of waterblocking glass yarns Ripcord (x) Inner sheath Corrugated steel tape Outer sheath Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer 6

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC CS LSZH FO cable with stranded loose tubes. Corrugated Steel protection. 5 6 7 8 9 0 Centre element, FRP optional with over sheath Loose tube with optical fibres Water blocking yarns or tape Filler Water blocking tape Reinforcement of waterblocking glass yarns (optional) Ripcord Inner sheath (LSZH (Optional) Corrugated steel tape Outer sheath (LSZH) 5 6 7 8 9 0 Standard colours Fibres Tubes Group Group Layer Layer Layer Red Red +t Red Red Red Green Green +t Green Green Green Blue 5 Blue +t Blue Blue Blue Yellow 6 Yellow +t Yellow Yellow Yellow 5 White 7 White +t 5 White 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 8 Violet 9 Turquoise Turquoise +t 9 Orange 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink Pink +t Turquoise Turquoise Turquoise note +t: indicates a black tracer Red Red Green Green 5 Blue 5 Blue 6 Yellow 6 Yellow 7

TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC CS HFFR FO cable with central tube. Corrugated steel tape protection. 5 6 7 5 6 7 Optical fibres Central tube with optical fibres Reinforcement of waterblocking glass yarns Inner sheath Ripcord (x) Corrugated steel tape Outer sheath Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer 8

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC-S CS HFFR FO cable with stranded loose tubes. Corrugated steel protection 5 6 7 8 9 5 6 7 8 9 Centre element, FRP optional with over sheath Loose tube with optical fibres Water blocking yarns or tape Water blocking tape Waterblocking glass yarn strength members Inner sheath Ripcord Corrugated steel Outer sheath Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink Tubes Layer Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Orange 0 Black Pink Turquoise 9

TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC CS FR FO cable with central tube. Corrugated steel tape protection. 5 6 7 8 5 6 7 8 Optical fibres Central tube with fibres Fire protective coating Reinforcement of waterblocking glass yarns Inner sheath Ripcord Corrugated steel tape Outer sheath Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer 0

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTMC FO mini-cable with stranded mini loose tubes. 5 6 7 5 6 7 Centre element FRP optional with over sheath Loose tube with optical fibres ( or fibres per tube) Water blocking layer Filler (only for constructions with 5 tubes or less (< 60 fibres) Cross-binder Ripcord Outer sheath (PE) Standard colours Fibres Tubes Group Group Layer Red Red +t Red Green Green +t Green Blue 5 Blue +t Blue Yellow 6 Yellow +t Yellow 5 White 7 White +t 5 White 6 Grey 8 Grey +t 6 Grey 7 Brown 9 Brown +t 7 Brown 8 Violet 0 Violet +t 8 Violet 9 Turquoise Turquoise +t 9 Orange 0 Black Natural 0 Black Orange Orange +t Pink Pink Pink +t Turquoise note +t: indicates a black tracer

TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTMC PA FO mini-cable with stranded mini loose tubes. 5 6 5 6 7 Centre element FRP optional with over sheath Loose tube with optical fibres ( or fibres per tube) Water blocking layer Filler (only for constructions with 5 tubes or less (< 60 fibres) Cross-binder Ripcord Outer sheath (PA) Standard colours Fibres Tubes Group Group Layer Red Red +t Red Green Green +t Green Blue 5 Blue +t Blue Yellow 6 Yellow +t Yellow 5 White 7 White +t 5 White 6 Grey 8 Grey +t 6 Grey 7 Brown 9 Brown +t 7 Brown 8 Violet 0 Violet +t 8 Violet 9 Turquoise Turquoise +t 9 Orange 0 Black Natural 0 Black Orange Orange +t Pink Pink Pink +t Turquoise note +t: indicates a black tracer

TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTMC FO mini cable with central tube. Optical fibres Central tube with, 6, 8,, fibres Reinforcement of aramide yarns Outer sheath (PP) Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer

TECHNICAL PRODUCT INFORMATION Cable construction and colour code MUC Micro unitube cable. 5 5 Optical fibres Jelly-filling Central tube Reinforcement of armide yarns Outer sheath Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Orange Orange +t 0 Black Natural Pink Pink +t Turquoise Turquoise +t note +t: indicates a black tracer

TECHNICAL PRODUCT INFORMATION Cable construction and colour code SFU Smooth Fibre Unit. Optical Fibres Inner layer (Acrylate) Outer sheath (PE) Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink 5

TECHNICAL PRODUCT INFORMATION Fibre Type offibre Standard Standard Product Characteristics - Optical fibres Hydrogen passivated, dispersion unshifted, matched cladding. Bending loss insensitive singlemode fibre 9/5µm. Fully compatible with G.65.D fibre. Optical and geometrical properties exceed ITU recommendations G.65.D and G.657.A IEC-6079--50, B6-a ITU-T G.657.A Characteristics: Properties Unit Mode field diameter; 0 nm 9.0 ± 0. µm M ode field diameter; 550 nm 0. ± 0. µm Core non-circularity max. 6 % C ore/cladding concentricity error max. 0. µm Cladding diameter 5.0 ± 0.5 µm Cladding non-circularity max. 0.6 % Coating diameter ±5 µm Coating/Cladding concentricity error max. 8 µm Temperature sensitivity; -60 C to +85 C max. 0.05 db/km Bending sensitivity-0 turn around Ø0 mm - 550 nm max. 0. db Bending sensitivity-0 turn around Ø0 mm - 65 nm max. 0. db Bending sensitivity- turn around Ø0 mm - 550 nm max. 0.75 db Bending sensitivity- turn around Ø0 mm - 65 nm max..5 db Proof test level min. 0.69 Gpa Fibre curl min. m Cable cut-off wavelength max. 60 nm Zero-dispersion wavelength 00 - nm Zero-dispersion slope max. 0.090 ps/nm².km Chromatic dispersion; 85 nm - 0 nm max.. ps/nm.km Chromatic dispersion; 550 nm max. 7 ps/nm.km Chromatic dispersion; 65 nm max. ps/nm.km Polarisation mode dispersion; maximum individual fibre max. 0. ps/ km PMDq max. 0.06 ps/ km Max. attenuation at 8 nm (α 8 ) [note a] <max. α 0 Effective Group Core Refractive Index; 0 nm.67 Effective Group Core Refractive Index; 550 nm.675 Effective Group Core Refractive Index; 65 nm.680 note a: after hydrogen ageing 6

TECHNICAL PRODUCT INFORMATION Fibre Product Characteristics - Optical fibres Type offibre Hydrogen passivated, dispersion unshifted, matched cladding bending loss insensitive singlemode fibre 9/5µm. Fully compatible with G.65.D fibre. Reduced coating diameter Standard ITU-T G.657.A Characteristics: Properties Unit Mode field diameter; 0 nm 9.0 ± 0. µm M ode field diameter; 550 nm 0. ± 0. µm Core non-circularity max. 6 % C ore/cladding concentricity error max. 0.5 µm Cladding diameter 5.0 ± 0.5 µm Cladding non-circularity max. 0.8 % Coating diameter 98 ±6 µm Coating/Cladding concentricity error max. 8 µm Temperature sensitivity; -60 C to +85 C max. 0.05 db/km Bending sensitivity-00 turns around Ø50 mm - 550 nm max. 0.05 db Bending sensitivity-00 turns around Ø60 mm - 65 nm max. 0.05 db Bending sensitivity-0 turn around Ø0 mm - 550 nm max. 0.5 db Bending sensitivity-0 turn around Ø0 mm - 65 nm max..0 db Bending sensitivity- turn around Ø0 mm - 550 nm max. 0.75 db Bending sensitivity- turn around Ø0 mm - 65 nm max..5 db Proof test level min. 0.69 Gpa Fibre curl min. m Cable cut-off wavelength max. 60 nm Zero-dispersion wavelength 00 - nm Zero-dispersion slope max. 0.090 ps/nm².km Chromatic dispersion; 85 nm - 0 nm max.. ps/nm.km Chromatic dispersion; 550 nm max. 7 ps/nm.km Chromatic dispersion; 65 nm max. ps/nm.km Polarisation mode dispersion; maximum individual fibre max. 0. ps/ km PMDq max. 0.06 ps/ km Max. attenuation at 8 nm (α 8 ) [note a] <max. α 0 Effective Group Core Refractive Index; 0 nm.67 Effective Group Core Refractive Index; 550 nm.675 Effective Group Core Refractive Index; 65 nm.680 note a: after hydrogen ageing 7

TECHNICAL PRODUCT INFORMATION Fibre Type offibre Standard Standard Product Characteristics - Optical fibres Hydrogen passivated, dispersion unshifted, matched cladding bending loss insensitive singlemode fibre 9/5µm. Fully compatible with G.65.D fibre. Optical and geometrical properties exceed ITU- recommendations G.65.D and G.657.A IEC-6079--50, B6-a ITU-T G.657.A Characteristics: Properties Unit Mode field diameter; 0 nm 8.7 ± 0. µm M ode field diameter; 550 nm 9.9 ± 0.5 µm C ore/cladding concentricity error max. 0.5 µm C ladding diameter 5.0 ± 0.5 µm Cladding non-circularity max. 0.7 % Coating diameter ±5 µm Coating/Cladding concentricity error max. 8 µm Temperature sensitivity; -60 C to +85 C max. 0.05 db/km Bending sensitivity-0 turns around Ø0 mm - 550 nm max. 0.0 db Bending sensitivity-0 turns around Ø0 mm - 65 nm max. 0. db Bending sensitivity- turn around Ø0 mm - 550 nm max. 0. db Bending sensitivity- turn around Ø0 mm - 65 nm max. 0. db Bending sensitivity- turn around Ø5 mm - 550 nm max. 0.5 db Bending sensitivity- turn around Ø5 mm - 65 nm max..0 db Proof test level min. 0.69 Gpa Fibre curl min. m Cable cut-off wavelength max. 60 nm Zero-dispersion wavelength 00 - nm Zero-dispersion slope max. 0.090 ps/nm².km Chromatic dispersion; 550 nm max. 8 ps/nm.km Chromatic dispersion; 65 nm max. ps/nm.km Polarisation mode dispersion; maximum individual fibre max. 0. ps/ km PMDq max. 0.06 ps/ km Max. attenuation at 8 nm (α 8 ) [note a] <max. α 0 Effective Group Core Refractive Index; 0 nm.676 Effective Group Core Refractive Index; 550 nm.68 Effective Group Core Refractive Index; 65 nm.685 note a: after hydrogen ageing 8

TELECOM SOLUTIONS If you need assistance or want to request a quote, please contact our sales team: Telecom headquarters Tel. + (0)5 57 55 Fax + (0)5 57 85 info@ace-fibreoptic.com Telecom France Tel. + (0)6 5 8 Fax + (0)6 5 8 info@ace-fibreoptic.com Telecom Germany Tel. +9 (0)8 660 5 Fax +9 (0)8 660 info-de@tkf.eu info@ace-fibreoptic.com Telecom Finland, Estonia, Latvia & Lithuania Tel. +58 0 666 Fax + (0)5 57 06 Tel. + (0)5 57 69 info@ace-fibreoptic.com Telecom Sweden Tel. +6 (0)5 00 Tel. + (0)5 57 69 TKF Telecom Services Tel. + (0)6 75 800 Service line + (0) 6 75 80 Fax + (0)5 57 06 Fax + (0)6 55 75 info@ace-fibreoptic.com telecomservices@tkf.eu 9

CABLE DRUM SIZES AND WEIGHTS A wide range of drums with various sizes and weights is used to store and transport our cables. The most common types of drums and their sizes and weights are shown in this table. Flange diameter (F) mm Core diameter (K) mm Central hole diameter (A) mm Largest width (B) mm Empty drum return To get your empty drums in the Netherlands collected quickly, please send your request to our shipping department via the website (www.tkf.eu) or by e-mail to haspels@tkf.nl. If drums have to be collected outside the Netherlands, please contact our sales staff. Winding width (W) mm Empty weight Kg Volume m³ *600 50 80 68 00 7,5 0,7 *800 00 00 80 00 0, 800 500 00 500 85 0, *000 500 00 605 85 8 0, 000 500 00 609 85 7 0,6 00 600 00 7 600 08,0 500 800 00 96 750 60, 600 800 00 00 8 0,6 800 900 00 00 8 00, 00 900 00 8 950 50 5,06 50 00 00 80 600 5,68 500 50 00 0 90 700 7,6 500 50 00 58 50 800 9, 650 50 00 88 75 850 0,5 800 700 00 50 57 050,9 000 600 00 600 5 50,0 * Plastic drum F = Diameter flange K = Diameter core A = Diameter axle-hole B = Largest width W = Winding width 50

MORE INFORMATION This catalogue contains information about product families. Information at item level can be requested via our website and from our sales staff. This catalogue has been customized. Information about products that are not included in this catalogue is available from our sales departments and can also be found on our website www.ace-fibreoptic.com. Please contact us for additional technical or commercial information. Contact information of our sales teams can be found on our website. Subject to changes TKF reserves the right to make changes to its product specifications and its range of products without informing clients of this in advance. Disclaimer This catalogue is put together with great care. Nevertheless we can t give any guarantees regarding the completeness, correctness or actualization of the information in this catalogue. No rights can be derived from the information as shown in this catalogue. TKF is entitled to modify this catalogue at all times with immediate effect due to (for example) changes in legislation. TKF can t be held responsible for the content of this catalogue or the consequences of using the information including incorrect translation of the information by third parties. TKF All rights reserved. Information in this catalogue may only be distributed with acknowledgement of the source. Terms of delivery Our general terms of delivery apply to all our deliveries including the products named in the catalogue. They are available via our website www.tkf.eu or from our sales departments. 5

TKF Finland TKF Sweden TKF Headquarters C&C Partners TKF GmbH TKF SAS 5 Copyright TKF No rights can be derived from this information.

Spinnerstraat 5 P.O. Box 6 NL-780 AA Haaksbergen The Netherlands Telephone: + (0)5 5755 Email: info@tkf.eu info@ace-fibreoptic.com Internet: www.tkf.eu www.ace-fibreoptic.com Copyright TKF Version 0-07