Modular Construction. Live/Work Urban Infill Townhome. Modular Construction. Enclosure Design. San Francisco Bay Area Net Zero Urban Infill

Similar documents
BSC Building America High Performance Homes: Today & Tomorrow. Peter Yost Senior Building Scientist

Overview. Case Study 2008 Building America Prototype ICI Showcase House. Daytona Beach, Florida. Project Team: ICI Homes, Building Science Corporation

Energy Consumption and User Comfort In Cold Climate NZEHs

Riverdale NetZero Project Summary of Costs and Expected Performance

ENERGY STAR V2.5 & 3 Designed to Qualify AIA Annual Convention

ENERGY COST AND FEATURE REPORT

UPGRADES. [Energy Efficiency] Base Points

Business Energy Efficiency Incentives 2007

High Performance or Hype Performance? Marc Rosenbaum, Some Real World Data. Marc Rosenbaum, P.E. South Mountain Company West Tisbury, MA

Performance of Solar Water Heating Systems in the United States

Steven Winter Associates, Inc. J827

1. HAMILTON WAY, FARMINGTON, CT

Residential New Home Construction Checklist

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

Missouri HERO Program Residential Eligible Product List

Julie Klump, POAH Rick Fenuccio, Tom Hartman Marc Rosenbaum Melpet preliminary heat loss and energy model results and implications

Anderson Sargent Builders. Barley Pfieffer Architects. Building Science Corporation

10 DEEP RETROFIT CASE STUDIES. Iain Walker Lawrence Berkeley National Lab

Passive House Northwest AIA CEU Provider. Aubrey Gewehr March 27, 2015

REQUIRED CONTRACT DETAIL. $2, , Direct DC Fuel Cell Power System, Stationary PACE Power output < 40 kw

Equipment Specifications and Required Information Quantity Rebate

Pro Eco-Energy. Home Assessment

Energy Efficient Myth Busters

Welcome. High Performance Mechanicals for Houses That Work. Energy Design Conference - Duluth, MN. February 21 st, 2018

2018 International Energy Conservation Code (IECC) Updates

The Ad-Hoc Passive House. Paul W Panish

Instantaneous Water Heaters

Total Credits 0.00 *Please refer to Table R406.2 for complete option descriptions

BALTIMORE GAS AND ELECTRIC COMPANY (BGE) Home Performance with ENERGY STAR Program. Rebate and Incentive Instructions

NET ENERGY WATER LOOPS A clear path to net zero energy buildings

Better Buildings By Design What are the best HVAC solutions for low-load, high performance homes? February 6-7, 2013

Intermediate framed denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation.

Address Account # Member # Equipment Specifications Quantity Rebate. ENERGY STAR Appliances

ENERGY & WATER EFFICIENCY: HOME ASSESSMENTS. Jim Riggins Monument, CO

EARTH ADVANTAGE HVAC REQUIREMENTS

Impact of Minimum Fan Efficiency Grade. Dr. John Cermak Executive Vice President ACME Engineering and Manufacturing Corp.

ENERGY SYSTEMS LABORATORY

A highly efficient Enclosure is Key. The Building is always the sum of ALL it s parts

2016 Annual Conference

Single-Family Weatherization Baseline Assessment (R5) Final Report

Net-zero and Near Net-zero Homes in Jefferson County

GEOTHERMAL: THE SMARTER CHOICE

Residential Track Unit 10 Understanding the Residential HERS Rating

nzeb office building

How to Heat Water in All-Electric Homes & Apartments?

Energy Upgrade California Home Upgrade Offered by The Energy Network

SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017

Step 4: Window Placement Matters

Building Division WSEC & IRC Ventilation (Effective July 1, 2016) Residential Buildings Prescriptive Compliance Form

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

HVAC 101. H V A C S y s t e m s

Summary Comparison of Simulation Program Features

School of Mines Lecture Notes Residential R&D and the Residential Energy Efficiency Value Gap June 14, 2011

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

Adelaide Homes Design Guide 4 - Winter warming

DEEMED SAVINGS TECHNICAL ASSUMPTIONS

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Triple E New Construction. Doug Manthey Conservation Technologies Chad Trebilcock Minnesota Power

SolarSheat Solar Heating and Ventilation. Todd Kirkpatrick-President Your Solar Home Inc. Vaughan, Ontario, Canada

Energy Efficiency Programs in Action

2015 RESIDENTIAL ENERGY CODE WORKSHEET BPA LOG# for Prescriptive Energy Code Compliance

Triple E New Construction. Doug Manthey Conservation Technologies Chad Trebilcock Minnesota Power

2013 Southern Nevada Home Tour

Non-residential Northwest Energy Efficiency Council Lisa Rosenow

2018 Rebate Catalog and Application

RESNET Rating Field Inspector Field Evaluation Form

Evaporative Cooling in a Hot-Dry Climate

Energy efficiency: Present and Future. Paul Kando Midcoast Green Collaborative

MF Mechanical Systems. Doug McCleery, PE, CEM March 2, 2016

Residential Heating and Cooling Loads

Multifamily Program Gas Water Heaters: Sealed Combustion Crossover Products

RESEARCH HIGHLIGHT. Arviat E/2 Northern Sustainable House Energy Consumption Performance Assessment

the STABLES Passive House Certifi cation Pending 3 bedrooms + offi ce / 4th bedroom 3 full bathrooms /- sq ft of living space

Building air conditioning systems using Ice-Cel thermal storage can be designed which cost little or no more than conventional chiller-only systems.

EnergyGauge USA Release Notes

Steve Jackson President, Enervison and Enviromatics Group Board of Directors, CHBA-Edmonton Region

Zero Energy Home. Team 4 Nittany Designs Edesign100 Section 15 Submitted to: Professor Wallace Catanach 2/22/13 Team Members

RECOMMENDATIONS FOR 15% ABOVE-CODE ENERGY EFFICIENCY MEASURES FOR RESIDENTIAL BUILDINGS

Energy Effcient Home Construction

Hot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT

Case Study: Furman University Charles H. Townes Center for Science. Michael K. Mantai, PE, CCP President System WorCx

RESNET HERS Rater Sample Test Questions 2

Seminar 34 Refrigerants Today, Tomorrow, and Beyond

ENERGY PERFORMANCE SCORE

Working With DHPS and Other Variable Capacity Heat Pumps. October 05, 2017

LEED for Homes Points

High Performance Building Guide 1

Energy Options for Residential Heating. Juergen Korn, P.Eng.

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

SEMINAR 48 (ADVANCED) International Codes and Standards Issues Impacting use of A2L Refrigerants in Unitary Heat Pump and Air-Conditioning Equipment

A Long-Term Case Study in Residential Sustainability

Integrating Emerging Technologies and Codes & Standards

Rebate Catalog. Save money on qualified Home Cooling Systems, Appliances and more. Read about rebates for your home and business at mid.

What Works Lessons in German American Collaboration

How to Build High-Performance Homes for Less Than $150/Square Foot

3- to 24-Ton Models. Commercial Packaged Rooftop Units. The most energy-efficient rooftop unit in the industry *

Energy Efficient Measures That Add Little or no. Program Lights & Appliances: How To Benefit from the Low-Hanging Fruit

HOME PERFORMANCE ENERGY ANALYSIS

The Most Effective Energy Upgrades for Existing Buildings

Customized Energy Audit Report

Transcription:

Learning Objectives for this Session Kohta, June 25-29, 11, Montreal, QC Compare the present and predicted future affordability of net zero energy homes. Provide an estimate of required PV price for NZEH to be an optimal solution in 30. Describe measures leading to market rate net zero houses. Describe the temperature distribution due to minimally distributed heating. Explain that whether or not an overall net zero balance is achieved is highly dependent on the user. Describe that in very efficient homes, standby loads become more and more important and unnecessary standby losses (for example a crankcase heater for a heat pump) can sum up to a significant part of the overall energy consumption ASHRAE is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will be reported to ASHRAE Records for AIA members. Certificates of Completion for non AIA members are available on request. This program is registered with the AIA/ASHRAE for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. Questions related to specific materials, methods, and services will be addressed at the conclusion of this presentation. Live/Work Urban Infill Townhome Modular Construction 1540 sf, 2 bedroom, 2 story Oakland, CA; ½ mile from train station (BART) USGBC LEED Platinum Rating 09 Green Builder Home of the Year 3 4 Modular Construction Enclosure Design R-32 Roof (nominal) Low density urethane foam under roof deck) R-23 Walls (nominal) 2x6 framing at 24 o.c. w. low density urethane foam or denim batt + 1 R-5 XPS Foundation R-7.5 XPS on crawl space walls; R-5 under crawl space slab Windows Low-E double pane + film / krypton filled, U=0.23 SHGC=0.42 Airtightness 964 CFM (3.1 ACH ) measured 5 6 6 Wall Section (c/o DSA Architecture) 1 of 5

Exterior Enclosure Features Mechanical Design, Lights, Appliances 16 SEER/9.5 HSPF air source heat pump Heat pump water heater in mechanical room/garage (2.11 EF rating) w. electric backup HRV ( minimally ducted) ventilation Central fan integrated supply-only ventilation Residential-scale economizer (off the shelf components, custom controller) CFL/LED lighting, Energy Star appliances Drainwater heat recovery system CENSORED 7 8 Renewable Energy 5.4 kw p photovoltaic system Inverter in garage System covers ~½ of roof Covered 90%+ predicted energy use (simulation) California net metering laws million Btu/year (source energy) Parametric Energy Simulations 0 180 160 140 1 80 60 40 Enclosure Improvements Δ 19% Mechanical Improvements Δ 19% Appliances, 94.8% Lighting Δ 10% 44.7% 0 US Average Benchmark As-built base Skylight Air seal Duct leak Wall R-19 OVE Wall R-5 XPS Roof R-38 Crawl wall R-7.5 Crawl floor R-5 Gar ceil R-38 Serious 725s 9.5 HSPF 16 SEER HP DHW GFX drainwater CFLs ES Appliances 5.4 kw PV Heating Cooling Hot Water Lighting Other 40% Reduction 9 10 Valuing energy upgrades relative to PVs Savings [10 6 Btu / yr] Extended Cost Effectiveness Analysis $ per 10^6 Btu Saved (1 year) Estimated Lifetime [yr] Cost per unit of energy saved Source Energy Savings (from typical analysis) Component lifetime $ per 10^6 Btu Saved (Lifetime) Energy saved over lifetime of measure Results of Economic Comparison Shows value of long-lived measures (e.g., enclosure upgrades) PVs $9 per 10 6 Btu Saved (Lifetime) Assumed 30 year lifespan, $4/installed W p (peak watt) (actual cost with rebates) Losing items in energy simulation analysis: Heat recovery ventilator ($64 per 10 6 Btu Saved) 16 SEER air conditioner ($44) Triple glazed (double + film) fiberglass windows ($19) Drainwater heat recovery ($11) 11 12 2 of 5

Water Heating: Conventional Options Conventional gas tank (~0.59 EF) site Source Efficiency 54% Water Heating: Best Options? Condensing instantaneous tankless (~0.9 EF) site Conventional electric tank (~0.92 EF) site Source Efficiency 82% Source Efficiency 27% ASHP (electric) water heater (2.11 EF) site Source Efficiency 63% California Title 24 Requirements: Time Dependent Valuation (TDV) Energy Calculations 13 Residential Economizer 14 Residential Economizer Results ORED CENS Air handler efficiency 6.2 CFM/W total flow (vs. 2.5 CFM/W typical for ECM) 170 CFM outside air drawn, 1 W 1.4 CFM/W outside air Cooling efficiency calculated at various ΔT; compared to DX cooling DX cooling more efficient than economizer when indoor-outdoor ΔT < 13 F Damper design vs. commercial economizers Risk of duct system leakage to outside in future ORED CENS Motorized skylight provides pressure relief CENSOR ED 15 16 17 18 3 of 5

19 Drainwater Heat Recovery System 1 Drainwater T In 45 Drainwater T Out Hot water bucket poured out to Tempered Out 40 Hot water bucket poured out to drain 110 Cold Mains Supply 90 30 80 Temperature (F) Temperature (C) 35 25 70 Shower @ 130 F/ 53 C (109 F/43 C @ drain) Kitchen Sink @ 133 F/56 C (129 F/54 C @ drain) Shower @ 111 F/ 44 C ( F/38 C @ drain) 60 15 Cold water run to chill drain line 21 10 0 1 22 0 Time (Minutes) Drainwater Heat Recovery Results % recovery = m (Tin HX Tout HX ) C (Tin HX Tout HX ) energy recovered = = energy required m (TDHW @ tap Tmains ) C (TDHW @ tap Tmains ) % recovery 19% at multiple temperatures Long term testing 0%-22% daily averages (13%±5%) Cast iron drain pipe thermal mass small effect (steady state ~5-6 minutes) Heat loss through pipe walls (3-5 F) Shower water temperature loss (130 F at the shower head to 109 F at the drain) 23 24 4 of 5

25 26 Overall Performance (Summary) 17 months data (13 months occupied data) 7560 kwh generated/7 kwh consumed (past 12 months): 15% excess 10,556 kwh generated/9165 kwh consumed (all data): 7% excess collection continuing Questions? Kohta kohta@buildingscience.com This presentation is based on a peer-reviewed paper (Paper 6733), which is available for sale in the onsite ASHRAE bookstore and the online ASHRAE bookstore following the conference. A complete list of references can be found in this paper. 27 28 5 of 5