LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

Similar documents
HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

Ventilation Requirements Schedule SCHEDULE BASED ON IMC 2009

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

University of Rochester October 17, 2008 Brooks Landing Business Center

DUKE UNIVERSITY CONSTRUCTION STANDARDS

A. Section Joint Sealants: Seal fixtures to walls and floors.

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

SECTION PLUMBING

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Plumbing Standards

GENERAL PLUMBING REQUIREMENTS

2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures

A. General: comply with appropriate standards. 1. International Association of Plumbing and Mechanical Officials: IAPMO. 2. California State AB 1953.

SECTION PLUMBING FIXTURES AND TRIM. A. Types of plumbing fixtures required for the project include the following:

Union County Vocational - Technical Schools Scotch Plains, New Jersey

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

DOMESTIC WATER PACKAGED BOOSTER PUMPS

GENERAL PLUMBING REQUIREMENTS

GENERAL PLUMBING NOTES

1. Division 22 Section "Emergency Plumbing Fixtures." 2. Division 22 Section "Drinking Fountains and Water Coolers."

PLUMBING FIXTURES, TRIM, AND SUPPORTS

SECTION PLUMBING SPECIALTIES

Mechanical/Plumbing Specification

DESIGN AND CONSTRUCTION STANDARDS July 2011

Mechanical Inspection Plumbing

SECTION DOMESTIC WATER PIPING SYSTEMS. 0. Pipe and pipe fittings are specified in the following sections:

The Water Efficiency Company. Vitreous China Fixtures

GENERAL PLUMBING REQUIREMENTS

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

CHILD DEVELOPMENT & LITERACY CENTER H17-N104-CB SGA 17002

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

DRAWING SCHEDULE TAB REQUIREMENTS BY EQUIPMENT TYPE TYPE OF EQUIPMENT DESCRIPTION COMPONENT TAB REQUIREMENTS

Willoughby Industries - Security Products

SECTION PLUMBING FIXTURES

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

GARCIA GALUSKA DESOUSA Consulting Engineers

Willoughby Industries - Security Products

JAMES P. KISSANE, ARCHITECT

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

GENERAL PLUMBING NOTES 6. ALL RISES AND DROPS IN PIPING ARE NOT NECESSARILY SHOWN

TABLE OF CONTENTS DIVISION 22 - MECHANICAL

SHOE PALACE HUNTINGTON PARK M.200


MATERIALS Traps TRAPS. No. IPC IRC Description

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

PLUMBING DESIGN GUIDELINES SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS

D & L A.D.A. SOLUTIONS 448 WEST MAIN ST. AUBURN,WA (800) HOUR FAX (206) FROM THE PARTS PEOPLE. SUPPLY and MFG.

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

Wholesalers List Price Book. Effective Date: February 5, Fixtures WEP OLP. Faucets & Sinks. Manual Products WLP. Genuine MicroPlumb.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Wholesalers List Price Book. Effective Date: February 1, Fixtures WEP. Manual Products WLP HEALTHMINDER. Products HM. Genuine MicroPlumb

Protected with TechCoat finish. For Ceramic Tile Showers Cast iron Threaded for test nipple Extra heavy (.050) strainer DRAIN CONNECTION

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

A. This Section includes the following domestic water piping specialties:

SECTION DOMESTIC WATER PIPING SPECIALTIES

PRICE BOOK CONTENTS 010 PIPE

TUBS & SURROUNDS FIBERGLASS TUB STANDARD FIBERGLASS GARDEN TUB

Type A. Part # Description

500H TOILET VESSEL LAVATORY FREESTANDING TUB

Unit # E ± 1,200 SF Width ± 20' Depth ± 60'

Additions & Alterations to Ascension Parish Library Galvez Prairieville, Louisiana Project No. 1401

Yale University Design Standards

FEATURES. Other Fed-Flush Arrangements

Unit # H ± 2,000 SF Width ± 25' Depth ± 80'

Wholesalers List Price Book. Effective Date: March 4, Fixtures WEP. Faucets, Soap Dispensers. Manual Products WLP. Parts PWT. Genuine MicroPlumb

SECTION BASIC MATERIALS AND METHODS

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PARTS STOCKED REPLACEMENT FAUCET BIBB SCREWS... SCREW ASSORTMENT MISC. 3 /8" BIBB LOC SCREW 1 /2" BIBB SCREW 1 /2" BIBB LOC SCREW 3 /8" BIBB SCREW

DIVISION 22: PLUMBING DESIGN STANDARDS TABLE OF CONTENTS

Unit # 1038 ± 900 SF Width ± 15' Depth ± 60'

PRODUCTS THAT CONSERVE, REPAIR AND SAVE!

WAL-RICH CORPORATION SINCE 1950

BSD Technical Standard. Division 22: Plumbing

CLINICAL SERVICES ADMINISTRATION (214)

DeCA DESIGN CRITERIA HANDBOOK PLUMBING SYSTEMS

AIRPORT PLUMBING DESIGN STANDARDS REV. 3 3/18/2016

TOILET BOWLS AND TANKS

Helping create a better healthcare experience.

Electrical Information

8 Kitchen Gooseneck. 4 Lavatory/Shower. 8 Shower. Adjustable Garden Tub. Diverter Spring & Spool Diverter Knob Plastic Aerator Speedy Locknut

University of New Hampshire Scholars' Repository

REAR. Exit 5'-9" 6'-1" 8'-3" 6'-1" Freezer Entrance Stall

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

Plumbing and Drainage

PLUMBING REQUIREMENTS

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Plumbing. September 8, 2018 Prices and product availability are subject to change without notice. 32" Curved Shower Pan with Round Front - Parchment

A. This Section includes the following emergency plumbing fixtures:

2. All necessary storm and sanitary pumps shall be tied into emergency power, and sump levels shall be monitored electronically through the B.A.S.

Plot # R019A ± 74' ± 74' ± 65' Plot # R019A LEASE OUTLINE DRAWING GROSS LEASABLE AREA ± 4,631 S.F. DEMISING FRONT WIDTH DEPTH ± 13' ± 32' Lease Line

Unit HH Gregg. ± 30,000 SF Width ±26' Lakeland Retail Center. Lease Outline Drawing. Unit HH Gregg. Depth ± 145' HVAC Units & Information

ABV AD AFF CO CODP COTG COWP CW DN EWC FD HB HW

TABLE OF CONTENTS. BARIATRIC SINKS & TOILETS Specially engineered fixtures designed to withstand loads typical in bariatric care environments.

PLUMBING FIXTURES CHAPTER 27

APPENDIX J ILLUSTRATIONS

Paradise Marketplace. Unit # AOP +/- 1,600 SF +/- 12' +/- 11' +/- 8' 11'-7" +/- 85' +/- 74' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width.

Transcription:

ELECTRIC WATER HEATER SCHEDULE DESIGNATION MODEL MANUFACTURER STORAGE RECOVERY TEMPERATURE LEAVING ELECTRICAL CHARACTERISTICS REMARKS/SPECIAL INSTRUCTIONS NUMBER GALLONS RATE RISE WATER K.W. VOLTAGE PHASE G.P.H. TEMPERATURE WH DEN-30 A.O. SMITH 30 8 100 140 2 208 1 CONTRACTOR SHALL INSTALL EXPANSION TANK IF REQUIRED. INSTALL WATER HEATER PER MANUFACTURERS INSTRUCTIONS INSTALL THERMOSTATIC MIXING VALVE SIMILAR TO SYMMONS #410-B ON EACH FAUCET GENERAL NOTES: 1. CONTRACTOR SHALL PROVIDE DIELECTRIC UNIONS AT WATER HEATER CONNECTIONS. 2. CONTRACTOR SHALL PROVIDE BALL VALVES AT WATER HEATER CONNECTIONS. 3. CONTRACTOR SHALL PROVIDE T&P RELIEF VALVE, DRAIN VALVE AND EMERGENCY OVERFLOW DRAIN PAN FOR WATER HEATER. T & P AND OVERFLOW DRAINS 4. DISCHARGE OUTSIDE OR INTO NEAREST OPEN SIGHT DRAIN. PLUMBING FIXTURE SCHEDULE MANUFACTURER SAN. COLD HOT DESIG. DESCRIPTION & MODEL SWR VENT WTR WTR DESCRIPTION / REMARKS NUMBER SIZE SIZE SIZE SIZE WALL MOUNTED AMERICAN STANDARD 4" 2" 1" - WALL MOUNTED DIRECT FED SIPHON JET ACTION ELONGATED BOWL VITREOUS CHINA HWC WATER CLOSET AFTWALL #3353.128 SIPHON JET ACTION TOP SPUD BOWL, BOLT CAPS SLOAN ROYAL #152 ES-S TMO SWB (1.28 GPF) FLUSH VALVE OLSONITE FLUSH VALVE WITH VACUUM BREAKER ANGLE STOP AND FLUSH CONNECTION. 1.28 GPF PLASTIC SEAT PROVIDE JOSAM FLOOR MOUNTED CAST IRON SUPPORT. WALL MOUNTED AMERICAN STANDARD 4" 2" 1" - WALL MOUNTED DIRECT FED SIPHON JET ACTION ELONGATED BOWL VITREOUS CHINA HWC WATER CLOSET AFTWALL #3353.128 SIPHON JET ACTION TOP SPUD BOWL, BOLT CAPS SLOAN ROYAL #152 ES-S TMO SWB (1.28 GPF) FLUSH VALVE OLSONITE FLUSH VALVE WITH VACUUM BREAKER ANGLE STOP AND FLUSH CONNECTION. 1.28 GPF PLASTIC SEAT PROVIDE JOSAM FLOOR MOUNTED CAST IRON SUPPORT. WATER FREE SLOAN 2" 2" - - (ADA) TOUCH FREE WATERLESS URINAL WALL HUNG WHITE VITREOUS CHINA WITH SMOOTH UR URINAL WATERFREE NON-POROUS SURFACES AND ODOR FREE VANDAL RESISTANT SEALED LOCKING CARTRIDGE ADA APPROVED WES-1000 DOMESTIC HOT WATER CIRCULATOR SCHEDULE DESIGNATION MODEL MANUFACTURER TOTAL IMPELLER & TOAL GPM PUMP ELECTRICAL CHARACTERISTICS REMARKS/SPECIAL INSTRUCTIONS NUMBER HEAD IN VOLUTE WATTAGE H.P. VOLTAGE PHASE FEET MATERIAL CP-1 UP25-64BF GRUNFOS 15 BRONZE 20 185 1/12 115 1 REFER TO INSTALLATION DETAIL DO NOT MOUNT MOTOR SHAFT IN VERTICAL POSITION GENERAL NOTES: 1. CONTRACTOR SHALL PROVIDE TIMER AND THERMOSTAT CONTROL OF PUMP, REFER TO DETAIL 2. CONTRACTOR SHALL INSTALL PUMP PER MANUFACTURERS REQUIREMENTS AND RECOMMENDATIONS. TEXAS ENERGY CODE COMPLIANCE CONTRACTOR SHALL PROVIDE HEAT TRAPS ON VERTICAL PIPE RISERS TO WATER HEATER STORAGE TANKS SERVING NON-RECIRCULATING HOT WATER SYSTEM. INSTALL HEAT TRAPS ON BOTH THE INLET AND OUTLET PIPING. HEAT TRAPS SHALL BE INSTALLED AS CLOSE AS PRACTICAL TO THE STORAGE TANK. CONTRACTOR SHALL PROVIDE AUTOMATIC TIME SWITCH ON DOMESTIC HOT WATER RECIRCULATION PUMP. AUTOMATIC TIME SWITCH SHALL BE SET TO SWITCH OFF THE RECIRCULATION SYSTEM DURING EXTENDED PERIODS WHEN HOT WATER IS NOT REQUIRED. FOR AUTOMATIC-CIRCULATING HOT WATER SYSTEMS, PIPING SHALL BE INSULATED WITH 1 INCH OF INSULATION HAVING A CONDUCTIVITY NOT EXCEEDING 0.27 BTU PER INCH/H XFT2 X F DEGREES. THE FIRST 8 FEET OF PIPING IN NON-CIRCULATING SYSTEMS SERVED BY EQUIPMENT WITHOUT INTEGRAL HEAT TRAPS SHALL BE INSULATED WITH 0.5 INCH OF MATERIAL HAVING A CONDUCTIVITY NOT EXCEEDING 0.27 BTU PER INCH/H X FT2 X F DEGREES. CONTRACTOR SHALL PROVIDE A THERMOSTATIC MIXING VALVE ON THE HOT WATER SUPPLY PIPE SERVING PUBLIC RESTROOM LAVATORIES. THERMOSTATIC MIXING VALVE SHALL BE SET FOR A MAXIMUM TEMPERATURE OF 110 DEGREES. ADA/TAS PLUMBING FIXTURES CONTRACTOR SHALL VERIFY ADA/TAS PLUMBING FIXTURE LOCATIONS AND REQUIREMENTS WITH FINAL ARCHITECTURAL CONSTRUCTION DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL ADA/TAS APPROVED PLUMBING FIXTURES SHOWN ON THE FINAL ARCHITECTURAL CONSTRUCTION CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS. CONTRACTOR SHALL INSTALL ADA/TAS APPROVED PLUMBING FIXTURES TO COMPLY THE LATEST VERSIONS OF THE ADA AND TEXAS ACCESSIBILITY STANDARDS CODES. LAV KS SK MS FD FCO CO WCO NOTES: 1 2 3 4 5 6 7 8 9 10 COUNTERTOP AMERICAN 2" 2" 1/2" 1/2" VITREOUS CHINA, FRONT OVERFLOW WITH 8 INCH CENTER SET FAUCET COUNTERTOP LAVATORY STANDARD LAVATORY. FURNISHED COMPLETE WITH CHROME PLATED OFFSET 1 1/2 INCH P-TRAP H & CW SUPPLIES AQUALYN ANGLE STOPS WITH FLEXIBLE METAL SUPPLIES, HANDI LAV GUARD INSULATION KIT, AND ADA #0476.028 SLOAN MODEL ETF-600 ELECTRONIC INFRARED SENSOR FAUCET DOUBLE BOWL JUST MFG 2" 2" 1/2" 1/2" DOUBLE COMPARTMENT 18 GAUGE STAINLESS STEEL SINK WITH THREE HOLE PUNCHING COMPARTMENT DBW-2133-A-GR-L STAINLESS STEEL SELF RIMMING SINK 5 1/2 INCHES DEEP FOR ADA. STAINLESS STEEL MOEN #8799 FAUCET 1/2 HP 115 V DISPOSAL KITCHEN SINK ADA SINGLE JUST MFG 2" 2" 1/2" 1/2" SINGLE COMPARTMENT 18 GAUGE STAINLESS STEEL SINK WITH THREE HOLE PUNCHING COMPARTMENT SL-ADA-1921-A-GR STAINLESS STEEL SELF RIMMING SINK 6 INCHES DEEP FOR ADA. STAINLESS STEEL MOEN #8799 FAUCET ADA SQUARE FIAT TERRAZZO TSB-100 24 INCH X 24 INCH X 12 INCH MOP SINK WITH DELTA 28T2383 FAUCET MOP SINK TSB-100 3" 2" 3/4" 3/4" FIAT NO. 898-CC MOP HANGER, NO. 832-AA HOSE WITH BRACKET WITH GUARD AND NO. 1453-BB STAINLESS STEEL STRAINER. HOSE PROVIDE ONE MSG 2424 WALL GUARD. FLOOR DRAIN WADE 3" 2" 1/4" - CAST IRON BODY, FLASHING COLLAR WITH NICKEL BRONZE ADJUSTABLE STRAINER HEAD, FOR RESTROOMS 1100 TRAP PRIMER CONNECTION, VANDALPROOF TOP,, SPEED SET OUTLET AND NO AND EXPOSED WITH TRAP PRIMER HUB ADAPTER. VERIFY ROUND OR SQUARE TOP WITH ARCHITECT AREAS CONNECTION INTERIOR FLOOR WADE COATED CAST IRON KLEENATRON, LEVELEZE FLOOR CLEANOUT, INTEGRAL GASKETED CLEANOUT 6000STD-1 BRONZE CLEANOUT PLUG, ADJUSTABLE HOUSING WITH SCORIATED SECURED ROUND NICKALOY TOP. CONTRACTOR SHALL SELECT COVER FOR FLOOR COVERING USED REFER TO ARCHITECTURAL DRAWINGS FOR TYPE OF FLOOR COVERING. EXTERIOR WADE COATED CAST IRON KLEENATRON, LEVELEZE FLOOR CLEANOUT, INTEGRAL GASKETED CLEANOUTS 6000X-1 BRONZE CLEANOUT PLUG, ADJUSTABLE HOUSING WITH SCORIATED SECURED PROVIDE ROUND NICKALOY TOP. CONTRACTOR SHALL PROVIDE CONCRETE PAD. REFER TO DETAIL PAD WALL CLEANOUT WADE ROUND STAINLESS STEEL WALL ACCESS COVER WITH CENTER SCREW, COATED CAST TEE WITH ACCESS 8560/8480R IRON CLEANOUT TEE WITH HUB AND SPIGOT CONNECTION AND RECESSED BRONZE COVER TAPPED PLUG. PROVIDE VANDALPROOF SCREW. REFER TO WALL CLEANOUT DETAIL WALL HUNG PLUMBING FIXTURES SHALL BE SUPPORTED USING ADJUSTABLE CONCEALED ARM FLOOR MOUNTED SUPPORTS WITH RECTANGULAR STRUCTURAL STEEL UPRIGHTS UTILIZING HEAVY-DUTY CAST-IRON FEET BOLTED TO THE FLOOR AND CAST IRON SUPPORT HEADERS. FLOOR AND HUB DRAINS IN RESTROOMS AND MECHANICAL ROOMS, ALSO DRAINS WHICH RECEIVE HVAC CONDENSATE AND DRAINS NOT FREQUENTLY USED SHALL HAVE AN AUTOMATIC TRAP PRIMER ACTIVATED BY A DROP IN WATER PRESSURE. TRAP PRIMER SHALL BE LOCATED DIRECTLY BEHIND A 10 INCH BY 10 INCH ACCESS PANEL FLUSH WITH WALL ACCESS PANEL, LOCATED AS DIRECTED BY THE ARCHITECT. ACCESS PANEL LOCATIONS SHALL BE COORDINATED WITH ARCHITECT PRIOR TO ROUGH-IN. ARCHITECT RESERVES THE RIGHT TO RELOCATE ACCESS PANEL PRIOR TO INSTALLATION WITHOUT ADDITIONAL COST. CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS AND LOCATIONS OF ALL PLUMBING FIXTURES INCLUDING HANDICAPPED (ADA) FIXTURES. CONTRACTOR SHALL COORDINATE ADA REQUIREMENTS WITH ARCHITECT PRIOR TO INSTALLATION OF PLUMBING FIXTURE. THE PLUMBING AND ARCHITECTS DRAWINGS. CONTRACTOR SHALL PROVIDE ADA FIXTURES AS SHOWN ON BOTH FLUSH VALVE FOR THE HANDICAPPED PLUMBING FIXTURES SHALL BE INSTALLED WHERE THE HANDLE FACES INTO THE OPEN AREA WITHIN THE STALL. (TOWARDS THE CENTER OF STALL) CONTRACTOR SHALL PROVIDE FLEXIBLE MOLDED INSULATION ON P-TRAPS, WATER SUPPLIES AND VALVES SERVING ADA PLUMBING FIXTURES. CONTRACTOR SHALL PROVIDE OFFSET P-TRAPS ON ADA FIXTURES CONTRACTOR SHALL INSTALL ALL PLUMBING FIXTURES SHOWN ON THE ARCHITECTURAL, KITCHEN, PLUMBING AND OWNER FURNISHED DRAWINGS. CONTRACTOR SHALL FURNISH AND INSTALL ON EACH PLUMBING FIXTURE CHROME PLATED BRASS P-TRAP, NIPPLES WITH ESCUTCHEON, CHROME PLATED BRASS ANGLE SUPPLIES WITH ALL METAL CONSTRUCTION CHROME PLATED FLEXIBLE BRASS RISERS WITH NIPPLES AND CHROME PLATED BRASS ESCUTCHEONS WITH CAST SET SCREW. CONTRACTOR SHALL PROVIDE ALL NECESSARY FITTINGS, PIPING, SUPPORTS, ETC. TO INSTALL EACH PLUMBING FIXTURE PER MANUFACTURER'S INSTALLATION INSTRUCTIONS AND TO COMPLY WITH CITY, STATE, ADA AND TAS CODES AND STANDARDS. CONTRACTOR SHALL REFER TO HVAC DRAWINGS AND PROVIDE ALL NECESSARY WASTE, VENT AND CW PIPING, ALSO VALVES AND FITTINGS REQUIRED TO INSTALL FLOOR AND HUB DRAINS RECEIVING CONDENSATE. FLUSH VALVES SHALL BE SIMILAR TO "SLOAN ROYAL" UNLESS OTHERWISE NOTED GAS LOAD SUMMARY SYSTEM DESIGNATION EQUIPMENT ITEM TOTAL QUANITY OR ITEM NUMBER DESCRIPTION CFH CFH BUILDING HEATING 1 RTU-1 ROOF TOP UNIT 60.00 60.00 1 RTU-2 ROOF TOP UNIT 120.00 120.00 1 RTU-3 ROOF TOP UNIT 120.00 120.00 1 RTU-4 ROOF TOP UNIT 120.00 120.00 1 RTU-5 ROOF TOP UNIT 60.00 60.00 1 RTU-6 ROOF TOP UNIT 150.00 150.00 SUBTOTAL 630.00 TOTAL GAS LOAD 630.00 SYSTEM INFORMATION OZ PER INCHES OF SQ INCH PRESSURE LEAVING METER 4 6.92 TOTAL EQUIVELANT PIPE LENGTH IN FEET WATER COLUMN