Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

Similar documents
SIMPLEX WEATHERPROOF CONTROL PANELS

We ve Got Panels Under Control.

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

QUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE!

Serious Products for Serious Contractors! User s Manual

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

Pump-Down Controller MODEL 4052

Dual Tower Heat Reactivated Desiccant Air Dryer

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Pump-Up Controller MODEL 4062

THE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR SHIPPING ON ALL CATALOG ORDERS!

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

CITY OF MEXICO BEACH REQUEST FOR QUOTES: LIFT STATION PANELS REPLACEMENT

TYPE POS Oil Shield Sump Pump

product brochure Sump, Effluent and Sewage Controls

Mission Critical. Fuel Supply Systems

2 SJE-Rhombus...The Name You Trust Above: Simplex - Below: Duplex Above: Simplex - Below: Duplex

TECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

Specifications. STEALTH Simplex, Wall Mount For SGV, OGP & OGV Grinder Pumps Control Panels & Accessories.

Oxygen (O2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Hydroflo Prepackaged Pumping Systems

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

Alarm Systems Alarm Bot CS2004E CS CS CS H2Oil Alarm System...12

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

ESSEX ENGINEERING CORPORATION

Control Panel with Across The Line Starters

I P. Tough Starters for Tough Environments. Explosion Proof Starter. Ready to Install, Completely Wired and Assembled

PRODUCT PRICE BOOK Pricing Effective February 4, We ve Got Panels Under Control.

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Soft Start Series MP700 Solid State, Reduced Voltage

PRYCO, INC. FUEL CONTROL

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

PUMP CONTROL CENTER (PCC)

Annunciation, Remote Monitoring, Control Industrial Control Panels

2018 PRICING. alderonind.com STANDARD PRODUCTS

DIESEL Engine Fire Pump Controllers Features

Lift Station Monitoring & Control The process begins here

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

TECHNICAL DATA OBSOLETE

Engineer's Guide Specification

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective

Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines

Across-the-Line SERIES MP300 Combined Manual and Automatic

GRUNDFOS DATA BOOKLET SLC, DLC. Pump controllers

Transfer Switch Features

SUBMERSIBLE SOLIDS HANDLING PUMPS Features and Benefits:

Transfer Switch Features

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

PumpSaver ISS-105 IS Super Cell Installation Guide

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

FTA550 JOCKEY PUMP CONTROLLERS

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

Two-Channel Gas Controller

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Fluid Cooler Fan and Pump control panel

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

SECTION 4000 LIFT STATIONS

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

Commercial and Light Industrial Fire Alarm Control Panel

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Universal Gas Detector

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

Variable Frequency Drive SERIES MP800 VFD

wireless. web-based. worthy of the name RACO.

Drawing Submittal Package

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

FDF Foam Pump Controllers Features

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

PARTS AND SERVICE MANUAL FOR MERCO HOLDING CABINET MODEL 86002

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Electric Coils. Blower Coils. Product Information

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

Installer Friendly Series In-Site. Installation Instructions and Operation/Troubleshooting Manual. Installation. Mounting the Control Panel

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Pioneer-R16 Gas Monitor Operator s Manual

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Conventional Releasing Control Panel

LMR Electric Fire Pump Controllers Features

Transcription:

The Custom Controls Solution Provider Hydromatic has a reputation for providing dependable submersible pumps for wastewater lift stations and has continually raised the bar for quality products and customer expectations. This reputation continues with a new generation of custom controls the HYDROMATIC NOVUS Series. In a time when the market is saturated with average controls provided by local panel shops with inadequate pump experience, Hydromatic offers a total solution for the design engineer, contractor, developer and municipality. This solution provides custom controls, coupled with quick delivery, competitive pricing, dependable customer service from start to finish, unlimited options and an extended warranty for both the controls and the pump, all under the quality name of Hydromatic. Having a single source for custom controls and dependable pumps means less work in qualifying an alternative source as well as less administrative efforts and lower costs. The HYDROMATIC NOVUS Series offers a real advantage by supplying a turnkey wastewater lift station package when significant engineering effort is required. A New Generation Custom built to your specifications and individually tested, the HYDROMATIC NOVUS Series is available in five different models: 1000, 1000 Plus, 2000, 3000 and 4000. The series starts with the dependable yet inexpensive HYDROMATIC NOVUS 1000 Series which features basic relay logic controls in a quality NEMA 3R painted steel enclosure. The next model is the HYDROMATIC NOVUS 1000 Plus Series offering additional features in a NEMA 4X enclosure for Hydromatic 2HP grinder packages. The HYDROMATIC NOVUS 2000, 3000, and 4000 Series offer more advanced features. These series utilize state-of-the-art digital controllers that are optimized for submersible pumps in simplex, duplex or triplex wastewater lift stations. Novus 2000 Simplex Novus 2000 Duplex Complete Management The HYDROMATIC NOVUS Series gives you complete control over simplex, duplex or triplex wastewater lift stations through state-of-the-art controllers. Using sensor inputs for Hydromatic submersible pumps, the controllers use three to five float systems or pressure transducers to control liquid levels. In addition, the controllers include outputs to control the pump(s), a high alarm light, seal fail light(s), over temperature light(s), pump run light(s) and an alarm horn. Plug-in terminal strips make field repairs and troubleshooting quick and easy. The controllers are mounted in your choice of enclosure type with an alarm light, circuit breakers, and motor starter(s). Novus 4000 Simplex, Duplex, or Triplex Page 2

The HYDROMATIC NOVUS 1000 Series panels are designed for simplicity and engineered for quality, yet are inexpensive. Featuring basic relay logic controls, the panels are built for durability. Available in simplex and duplex, the panels are UL Listed 508A, with 698A as an option. The NOVUS 1000 Series comes standard in a NEMA 3R painted steel enclosure with other enclosure options available. Panels are available within two weeks but expedited orders are also possible. Available in simplex and duplex single phase to three phase, the Novus 1000 Plus Series is an innovative approach for Hydromatic 2HP grinder packages. This series offers an exclusive control circuit board conveniently located on the sub-door. In addition, using a standard sub-door and raised back panel, the Novus 1000 Plus Series houses practical features such as circuit breakers, start components, contactors and a terminal strip. Standard features include lockable latches, a flashing red alarm light with an electronic horn, the innovative touch to silence pad, and a control circuit board, all in a NEMA 4X enclosure. Available in simplex and duplex, the HYDROMATIC NOVUS 2000 Series features a float switch activation based controller in a NEMA 3R painted steel enclosure. With sensor inputs for seal fail and over temperature, the controller connects to three (for simplex) or four (for duplex) float switches to measure the tank level. In addition, outputs are included to control the pump(s), a high alarm light, seal fail light(s), over temperature light(s) and an alarm horn. The high-tech controller has a built-in HOA (hand-off-automatic) switch and pump running light(s). Plug-in terminal strips make replacement in the field quick and easy. Field expertise is minimized and troubleshooting is simplified using the NOVUS controller unit. The following features are integrated into the state-of-the-art circuit board: Standard flashing high intensity LED alarm lights bulbs never need replacement Pump call to run light(s) Verified pump run light(s) Over temperature and seal fail light(s) Hand-off-auto switch(s) High level alarm light Alarm test features Alternation selector switch (duplex version) Built-in delay for pump starts and stops (duplex version) Novus 2000 Simplex Novus 2000 Duplex Advantages of this series include: The most features available for the money Competitive cost Size of enclosure required is reduced Field replaceable controller (two plug-in terminal blocks) Minimization of field expertise and simplification of troubleshooting Page 3

Available only in duplex, the HYDROMATIC NOVUS 3000 Series features a float switch activated controller unit for use by wastewater lift stations with dual pumps. The controller utilizes numerous indicator lights and external relay outputs to indicate possible errors in the lift station. This enables operators to take a proactive approach in managing lift stations. In addition to inputs from five normally open float switches, the HYDROMATIC NOVUS 3000 Series has sensor inputs for seal fail and over temperature from submersible pumps. The controller includes float simulate push buttons on each of the float inputs as well as a corresponding illuminated indicator. Both high and low level alarms are provided with a separate indicator light for each. Built-in alternation with a three position switch allows the controller to select automatic alternation or if the alternation is off to select between pump 1 and pump 2. Disable inputs for each pump can be used for SCADA, etc. The controller provides built-in support for an alarm horn with inputs for an external silence button. Another great feature is the float out of order detection with indicator light. Novus 3000 Duplex The HYDROMATIC NOVUS 4000 Series can be configured for many applications via the easy to operate front panel user interface. The controller units are designed to control up to three pumps in either pump up or pump down applications. The controller sequences pumps on and off in response to changes in level, pressure or flow. The primary sensor input is a 4-20 ma current loop that can be connected to any sensor with a 4-20 ma output. When used to control level in a tank or well, the input is usually connected to a pressure transducer or ultrasonic transmitter. A 4-20 ma loop power supply for the transducer is also provided. Field replacement is easy because terminal blocks unplug from the controller unit with no wires needing disconnected. Field expertise is minimized and troubleshooting is simplified using the NOVUS controller unit. Built-in software requires no programming. Simple menu structure allows easy display and modification of set points and setup configuration. 32 character alphanumeric liquid crystal displays information for level, status, and set point. Built-in elapsed time meters for all pumps are nonvolatile and easily examined from the front panel. Alternation selector switch on front panel turns alternation on and selects the lead pump if alternation is off. Individually selectable on/off set points provided for up to three pumps. 4-20 ma main sensors input with loop power supply for easy connection to most transducers and transmitters with adjustments provided for both scale and offset. All inputs operate on 115VAC and are internally fused and transient protected. Inputs provided for pump seal leak and over temperature sensors with red fail lights for out of specification conditions. Three auxiliary inputs can provide pump disable or pump run confirmation inputs for a fail to start test. Built-in single float backup system provided for pump down applications. Fully scalable 4-20 ma level output transmitter. Relay outputs provided for both high and low level alarms with adjustable set points. Built-in horn relay has internal silence button and input for external silence button. All terminal strips unplug without removing the wires for easy field replacement. Novus 4000 Simplex, Duplex, or Triplex The HYDROMATIC NOVUS 4000 Series options are limitless Page 4

The Hydromatic Novus Series 1000 1000 Plus 2000 3000 4000 Station Type Simplex N/A Available Standard N/A Standard Duplex N/A Available Standard Standard Standard Triplex N/A N/A N/A N/A Standard Single Phase Up to 7.5hp Up to 2hp Up to 7.5hp Up to 7.5hp Up to 7.5hp Three Phase 208/230v Up to 50hp 208/230v Up to 7.5hp 208/230v Up to 50hp 5/5/06 Unlimited 460v - Up to 150hp 460v - Up to 15 hp 460v - Up to 150hp N/A N/A Seal Probe Optional Optional Standard Standard Standard High Temp Optional Optional Standard Standard Standard Simplex Available Available Available N/A Available Duplex Available Available Available Available Available Triplex N/A N/A N/A N/A Available Level Control System Float(s) Qty. Available Available Available Available Available Bubbler N/A N/A N/A N/A Available Pressure Activated N/A Available N/A N/A N/A Transducer N/A N/A N/A N/A Available Ultrasonic N/A N/A N/A N/A Available Enclosure Type NEMA 3R Painted Steel Standard N/A Standard Standard Standard NEMA 4 Painted Steel Optional N/A Optional Optional Optional NEMA 4X Polycarbonate N/A Standard N/A N/A N/A NEMA 4X Fiberglass Optional N/A Optional Optional Optional NEMA 4X Aluminum N/A N/A N/A Optional Optional NEMA 4X Stainless Steel Optional N/A Optional Optional Optional Pedestal Mount Optional Optional Optional N/A N/A Inner Door Agency Listing Available N/A Standard N/A Standard Standard 508A culus Standard Standard Standard Standard Standard 698A culus Optional N/A Optional Optional Optional Components Pump(s) Circuit Breaker Standard Standard Standard Standard Standard Control Circuit Breaker Standard Standard Standard Standard Standard Fused - N/F Main Disconnect with N/A N/A N/A Optional Optional Inner Door Interlock Handle Main Breaker Optional N/A Optional Optional Optional Fused or N/F Main Disconnect Optional N/A Optional Optional Optional Generator Receptacle N/A consult factory Optional Optional Optional Manual Transfer Switch N/A consult factory Optional Optional Optional Hand - Off -Auto Switch Standard Hand Run Buttons Standard Standard Standard Pump Run Light(s) Standard Standard Standard Standard Standard Lead Pump Selector Switch Optional N/A Duplex Standard Standard Power On Indicator Light Optional Standard Optional Standard Standard Field Wiring Terminal Strip Standard Standard Standard Standard Standard I.E.C. Rated Motor Starters Standard Standard Standard Standard Standard Nema Rated Motor Starters Optional N/A Optional Optional Optional Intrinsically Safe Relays N/A N/A Optional Optional Optional Lightning Arrestor Optional N/A Optional Optional Optional Condensate Heater Optional N/A Optional Optional Optional Voltage Monitor (Single Phase) Optional N/A Optional Optional Optional Phase Monitor (Three Phase) Optional N/A Optional Optional Optional GFCI Receptacle W/Circuit Breaker N/A N/A Optional Optional Optional External Seal Fail Optional Optional Optional Optional Optional Dry Alarm Contacts Optional Optional Optional Optional Optional Elapsed Time Meters Optional Optional Optional Optional Standard Cycle Counters Optional Optional Optional Optional Optional External Alarm Light Flashing LED Alarm Light N/A N/A Standard Optional Optional Flashing Alarm Light Optional Standard Standard Standard Standard Audible Alarm Piezo Optional Standard Optional Optional Optional Alarm Horn Optional Optional Optional Optional Optional Alarm Bell Optional Optional Optional Optional Optional

Novus 2000 Simplex Novus 2000 Duplex Novus 3000 Duplex Novus 4000 Simplex, Duplex, or Triplex The HYDROMATIC NOVUS Series is the total solution for custom controls for wastewater lift stations. High-tech features are coupled with unlimited options, competitive pricing, quick delivery, dependable customer service, and an extended warranty for both the controls and the pump. Come back to Hydromatic for custom controls, superior quality products and extraordinary customer service. Your Authorized Local Distributor USA 740 East 9th Street, Ashland, Ohio 44805 Tel: 419-289-3042 Fax: 419-281-4087 2006 Hydromatic Ashland, Ohio. All Rights Reserved. www.hydromatic.com CANADA 269 Trillium Drive, Kitchener, Ontario, Canada N2G 4W5 Tel: 519-896-2163 Fax: 519-896-6337 E-02-7510 5/06