User guide. for smoke detector

Similar documents
PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

PLEASE READ THIS USER GUIDE CAREFULLY

PLEASE READ THIS USER GUIDE CAREFULLY

PLEASE READ THIS USER GUIDE CAREFULLY

1 Introducing Eve Smoke

Smoke Alarm User s Manual

RF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors

Wireless Interlink Smoke Alarm + 10 Year Life

USER MANUAL 10 YEAR LIFE SMOKE ALARM

SMART SMOKE DETECTOR

1. Safety instructions Mounting location in rooms of the heat detectors... 3

Operating instructions for the wireless smoke alarm detector type: GS558

INSTALLATION AND OPERATION MANUAL

Operating instructions for the radio heat detector GS412

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

RMS-I-DE-01 Smoke Detector

WIRELESS PHOTOELECTRIC SMOKE ALARM

Smoke Alarm User Manual

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

Electronic Smoke Detector m-rmf150

Security + Automation Made Easy QUICK START GUIDE

Digimax 210. Programmable Thermostat Compatible with Maxi Controller. User Guide

PHOTOELECTRONIC SMOKE DETECTOR

SMOKE User Manual. NE v2.0

1161/1162 Residential Wireless Detectors

RADION smoke RFSM-A. en Installation Guide

Datasheet CALYPSO II R. Interlinkable smoke alarm device

EN ES-D5B Wireless Smoke Detector. Instrukcja pobrana ze sklepu

U S E R M A N U A L UBH1RF HEAT ALARM

Heat Alarm User s Manual

9 100% Recycled Paper

1161/1162 Residential Wireless Detectors

2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms

alerting transmitter user guide other resources online at

CAVIUS NANO LIMITED. 8 King Street, Te Puke 3119 Bay of Plenty, New Zealand. PO Box 11241, Papamoa 3118 Bay of Plenty, New Zealand

Smoke Alarm Legislation

WIRELESS SUPERVISED PHOTOELECTRIC SMOKE DETECTOR DÉTECTEUR DE FUMÉE PHOTOÉLECTRIQUE SUPERVISÉ SANS FILS. Model: EL-2703

Security + Automation Made Easy QUICK START GUIDE

Firehawk Fire Alarms Battery Powered. Information, Installation and Maintenance

Mobeye CM2410 GSM fire alarm communicator

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Smoke Alarms and Carbon Monoxide Alarms

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

Smoke Sensor w/escape Light. Do not use this sensor in hazardous (classified) locations or life safety applications.

Wireless Installation Instructions BETA

SF812 SMOKE DETECTOR. Include to or Exclude from a Z-Wave TM Network. Product Overview

SMOKE & HEAT DETECTOR

V-MUL-033(A0) RADIOLINK BASE

169MHz Telecare Devices Carbon Monoxide Detector

Smoke Alarm with RF Interlink User Guide

KFP-CF Series Operation Manual

USER MANUAL Mobeye ThermoGuard CM2200

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

USER INSTRUCTIONS MULTI-SENSOR FIRE ALARM 230V~ with Rechargeable Lithium Cell Back-up. Model: Ei2110

Installation Instructions

Alarm System SECURE AS 302

Smoke Alarm and Carbon Monoxide Alarm Installation

SMOKE DETECTOR USERS GUIDE SMOKE DETECTOR SETUP GUIDE

First Alert Detector Error In Basement Please See Manual

Smoke Alarm User Manual

Datasheet for Models: 1SFWR 1SFW. NEW range. capability. 230V Mains Fast-Fit Ionisation Smoke Alarms. Key Features. Applications

ADT Carbon Monoxide Alarm

ADR 20N SELF CONTAINED OPTICAL SMOKE DETECTOR

X64 Wireless Training

Deaf & Hearing Impaired RadioLINK Alarm System

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

TX7100. Intelligent Addressable Optical Smoke Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Mira Platinum Wireless Controller

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

Watchguard Fire and Theft

ULTRASONIC OIL LEVEL MONITOR & ALARM

Hive Motion Sensor. User guide

Vibby. Installation Guide. t: f: e: w: uk.tunstall.com Version: V3.9

Honeywell Smokr detector. Overview. Accessories

Hive Window or Door Sensor. User guide

Zigbee Smoke Sensor PSG03

Remote alarm unit Art. Nr.:

Wake-up Vibration Alarm Model : VR101. User Manual

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

Wireless Keypads LKP(E)S8M Series

D1265. User's Guide. Touchscreen Keypad

Temporary wireless battery operated fire system from Channel Safety Systems

setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11

Security System. User Guide for the LED Command Center

Smoke Detector and Siren. Manual

10 Year Smoke Detector and Siren

Synco living. Train the Trainer. Mounting Safety Devices. August 2007 Page 1/11 Train the Trainer - August 2007

External Wireless Sounder

Construction Products Regulation (CPR) Update. Graham Simons Technical Manager, FIA

USER S GUIDE. Smoke Alarm. Battery-powered

Consultant Specification AGILE Wireless Fire Detection System

Life Changing, Life Saving. The Vibby. User and Installation Guide

G4S SMARTalarm User Guide

5, SE GÅNGHESTER,

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

Visit Us on the Web! MODEL SS-795 EARLY WARNING SMOKE & FIRE ALARM WITH SILENCE CONTROL

Bosch Smart Home. Motion Detector Instruction Manual

Operating Instructions Version 1.2

Transcription:

by User guide for smoke detector

OPTICAL SMOKE ALARM DEVICE Commercial reference: 2105-002 Developed by CAVIUS The smoke alarm is designed for private homes, camping trailers, mobile homes and caravans. It is not recommended for boats. PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

CONTENTS Technical information...1 1. How to set up and connect alarms...5 2. The best areas to install the smoke alarm:...10 3. Areas where NOT to install the smoke alarm:...12 4. Placement:...13 5. Installing the smoke alarm:...15 6. Test function:...18 7. Normal mode:...20 8. Alarm mode:... 21 9. Pause/Hush function:...2 2 10. Low battery signal:...23 11. Battery replacement:...24 12. Trouble shooting:...2 5 13. Other information:...2 6

TECHNICAL INFORMATION The maximum number of alarms that can be interlinked within a house group are 32. Please note: These must be alarms from the range by The distance between interlinked alarms depends on the house layout and they should always be tested after installation. It is not advised to get more than 10m distance between two smoke alarms. Diameter: 60mm (house), 68mm (base) Height: 44mm 1

The alarm is powered by a replaceable 3v CR123A lithium battery. Please note that correct operation of the smoke alarm device is ensured by use of one of the following batteries: DURACELL, PANASONIC or HUIDERUI. Interlinked by RF: 868 MHz Complies to standards: EN14604:2005/AC:2008, EN300-220 2

CHAMBER FILTER TEST BUTTON

MOUNTING BASE RED LED

1. HOW TO SET UP AND CONNECT ALARMS: Start by pulling out the battery isolation strip as shown. DO NOT REMOVE THE PRODUCT LABEL ISOLATION STRIP Please note: The product label must not be removed as it contains important information regarding the product. 5

All alarms that need to be connected in the house should be put into Learn Mode by sliding the switch on the back of the alarm to the Learn Mode position. 1 NORMAL MODE 2 LEARN MODE

The red LED will light up to indicate that Learn Mode has been selected. Please note that when the alarms are placed in Learn Mode they can t be inserted into the mounting base. Do not take out the battery during Learn Mode as this will interrupt the learn process. 7

Press the button at the top of one alarm only. This alarm will become the master and will start sending out a specific house code to the other alarms. The red LED will flash. 1 2 8

As the other alarms receive the specific house code, they will also flash the LED light. When all alarms flash the red LED, they are connected and can be switched out of Learn Mode and installed. Optional: To connect smoke alarms with a home automation system (i.e. HomeWizard), also pair every smoke alarm individually according to the in-app instructions. 9

2. THE BEST AREAS TO INSTALL THE SMOKE ALARM: Install an alarm between possible fire sources and bedrooms as a minimum. Install alarms on each floor of the house, in hallways and stairways. Alarms in each room such as bed rooms and living rooms. Additional alarms increase the security. 10

Minimum Recommended

3. AREAS WHERE NOT TO INSTALL SMOKE ALARMS: In dusty rooms At the top of a high pointed ceiling, in ceiling corners, and within 50cm of a wall. In rooms where the temperature goes out side +4 o to 38 o C or above 90% relative humidity not condensing. In kitchens, garages, laundries, or too close to fireplaces; areas where either dampness, gases or smoke could occur. Place the alarm where it is reachable in order to test the battery and for maintenance. 12

4. PLACEMENT: The smoke alarm is design to be installed on a ceiling or wall. For ceiling installation: The smoke alarm should be a minimum of 50cm from the wall. Wall Ceiling Minimum 50cm from wall 13

For wall installation: The smoke alarm should be a minimum of 30 cm and maximum of 50cm from the ceiling. Wall Ceiling Minimum 30cm and maximum 50cm from ceiling With a minimum of one smoke alarm per floor and a maximum distance between smoke alarms of 10 meters. 14

5. INSTALLING THE SMOKE ALARM: Detach the alarm from the mounting base by twisting counter clockwise. Use the mounting base ring to mark the screw holes on the ceiling or the wall. MARK UP SCREW HOLES WITH A PEN

16 USE THE ENCLOSED SCREWS AND PLUGS

Once the mounting base is installed, attach the alarm by twisting clockwise until it clicks. If the battery is either missing or inserted incorrectly, or the switch is in Learn Mode, the smoke alarm will not be able to click into the mounting base. CLICK THE SMOKE ALARM FIRMLY INTO THE BASE TO LOCK 17

6. TEST FUNCTION: After installation, and at least once per quarter, test all of your alarms to ensure they are operating correctly and are within range of each other. It is recommended to check visually every week if the LED flashes correctly (every 48sec.) Press the test button on any alarm for at least 6.5 seconds (count 2 sets of 3 sound sweeps). This will send out a test signal from the alarm; all other connected alarms should receive the signal within a short time. The alarms will emit a short beep and the LED will flash every 8 seconds for 2 minutes. NOTE: Test signal will send a reduced RF signal in order to make sure it will work in normal condition. 18

When the test signal is sent out, the alarms will respond in two ways: 1. A single beep every 8 seconds indicates that the alarms are connected and functioning. 2. Three short beeps every 8 seconds indicates a smoke sensor fault. The alarm should be cleaned by running the vacuum (on a low setting) around the smoke alarm chamber and tested again. If required this indication can be stopped early on each alarm by a short press of the test button. TIP: It is safe to cover the sound output hole with your finger during the testing to minimize the sound level emitted. If the problem continues, please visit www.cavius.com for any trouble shooting. 19

7. NORMAL MODE: In normal mode the LED will flash every 48 seconds to show correct operation. 20

8. ALARM MODE: When a concertation of smoke is detected, the smoke alarm will go into Alarm Mode. It will sound the alarm signal and the LED will flash. The smoke alarm will also transmit the alarm signal to the other connected alarms, which will also sound the alarm signal after a short delay. Please note that only the originating alarm s LED will flash, so it can be identified. 21

9. PAUSE/HUSH FUNCTION: If the smoke alarms are to set into a false alarm by cooking, fireplace, etc. they can be paused for 10 minutes by pressing the test button on the originating smoke alarm only (indicated by the flashing LED). The reason of this is that it is necessary to locate the source of the alarm before using the hush function. This is to make sure that it is not a life threatening situation. 22

10. LOW BATTERY SIGNAL: Your product has a 5Y battery life. When the battery is starting its end of life, a short beep will sound out every 48 seconds for 30 days. The alarm effected by the low battery will only beep, no other connected alarms will sound. It is safe to change batteries in the alarms without going through the learn process again they will not forget the codes during the battery change process. 23

11. BATTERY REPLACEMENT: To replace the battery, detach the smoke alarm from the mounting base by twisting counterclockwise. Replace the battery respecting the polarities. Attach the alarm in the mounting base by twisting clockwise until it clicks, and test the alarm. 24

12. TROUBLE SHOOTING: Dust particles in the smoke chamber which can be removed by vacuuming the mesh. High humidity condensing which can be resolved by drying the smoke alarm. If the smoke alarm does not work when the test button is pushed, the probable cause is a faulty battery. Check if the battery is worn out and replace it. Always test the alarm after replacement of battery. 25

13. OTHER INFORMATION: Do not paint the alarm. Note the local country regulations regarding installation. Disposal: For battery and product, please dispose properly at the end of life. This is electronic waste which should be recycled. Please note local regulations about information to your insurance company regarding installed smoke alarms. 26

The CE mark affixed to this product confirms its compliance with the European Directives which apply to the product and, in particular, its compliance with the harmonized specifications of standard EN 14604 relating to Construction Products Regulation 305/2011. Download Declaration of Performance (DoP) en Declaration of Conformity (DoC) 1. Go to service.smartwares.eu 2. Go to: Find manuals and support for your product. 3. Fill in article number: 10.043.19 4. Download DoP 5. Download DoC Intended use: Fire Safety / Essential characteristics: passed - Nominal activation conditions / Sensitivity, Response delay and Performance under fire condition 27

- Operational reliability - Tolerance to supply voltage - Durability of operational reliability and response delay, temperature resistance. - Durability of operational reliability, vibration resistance - Durability of operational reliability, humidity resistance - Durability of operational reliability, corrosion resistance - Durability of operational reliability, electrical stability 126599 rev 2 16 0333 EN14604 : 2005/AC:2008 DoP no.: 2105-002 Distributed by: Smartwares Jules Verneweg 87 5015BH Tilburg The Netherlands Developed by: CAVIUS Aps Julsovej 16 8660 Silkeborg Denmark. Manufactured in P.R.C.

by Jules Verneweg 87 5015BH Tilburg The Netherlands