HFO-1234yf Performance in a Beverage Cooler

Similar documents
R-404A Alternative with Low Compressor Discharge Temperature

Low GWP Refrigerants for Air Conditioning Applications

Evaluation of HCFC Alternative Refrigerants

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR AC AND REFRIGERATION

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

ANALYSIS OF LGWP ALTERNATIVES FOR SMALL REFRIGERATION (PLUGIN) APPLICATIONS

New High Performance, Low GWP Refrigerants for Stationary AC and Refrigeration

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

DROP-IN EVALUATION OF REFRIGERANT 1234YF IN A RESIDENTIAL INTEGRAL HEAT PUMP WATER HEATER

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Stay in business: STOP installing R-404A / R-507A! R-404A R-507A

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Performance Measurement of R32 Vapor Injection Heat Pump System

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

Sustainability of Automobile Air- Conditioning System Using Refrigerant R1234yf Instead of R134a

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

New Refrigerants & Selecting Capital Equipment

The Current Path of Refrigerants

Seminar 34 Refrigerants Today, Tomorrow, and Beyond

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

COMPARATIVE PERFORMANCE ANALYSIS OF EXPERIMENTAL FRIGORIFIC AIR CONDITIONING SYSTEM USING R-134A AND HFO-1234YF AS A REFRIGERANT

Chapter 10. Refrigeration and Heat Pump Systems

CHAPTER 1 INTRODUCTION

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Study of R161 Refrigerant for Residential Airconditioning

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Development of centrifugal chiller and heat pump using low GWP refrigerant

Low GWP Refrigerants for Air Conditioning and Chiller Applications

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Transcritical CO2 Bottle Cooler Development

Honeywell Refrigerant Update

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Experimental Performance of R-1234yf as a Dropin Replacement for R-134a in Domestic Refrigerators

APS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017

A Comparison Between Refrigerants Used In Air Conditioning

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

Hot Surface Ignition Testing of Low GWP 2L Refrigerants

"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

*Corresponding author;

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

New Copper-based Heat Exchangers for R744 Refrigerant: Technologies for Tubes and Coils. Y. Shabtay, J. Black, N. Cotton

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

The analysis proceeded by adopting the ASHRAE guideline for conventional HVAC chiller applications. This guideline is summarized in Table II.

REVERSIBLE R744 (CO 2 ) HEAT PUMPS APPLIED IN PUBLIC TRAINS

A Primer on HFOs. Hydrofluoro-olefins Low-GWP Refrigerants. Brett Van Horn, PhD Arkema Inc.

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Behavior of R410A Low GWP Alternative Refrigerants DR-55, DR-5A, and R32 in the Components of a 4-RT RTU

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

NEW COPPER-BASED HEAT EXCHANGERS FOR R744 REFRIGERANT PART II: SYSTEM DESIGN AND CASE STUDIES

Refrigerants & Cooling in renovation buildings

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Gary Parker Refrigerants Product Manager

Brazed Plate Heat Exchanger for CO Applications

HFCs or the Old Refrigerants - what is the best Choice?

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Flammability and the Low GWP Refrigerant Challenge

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

European Experience in Certification of competence in ODS substitutes: F-gas and Alternative Refrigerants. Pune, 5 th March 2015

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Overview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol

Framtidens köldmedier

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Low GWP alternative refrigerants to R404A

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants

Experimental study on automotive cooling and heating air conditioning system using CO 2 as a refrigerant

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

Department of MCE, Islamic University of Technology 2. Abstract

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

DOE and EPA Impacts to Commercial Refrigeration

Kirby CO 2 Evaporators

Performance of CO2 Cycles with a Two-Stage Compressor

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Sub-Critical Operation of the CO2 Expander/ Compressor

Thermodynamics II Chapter 5 Refrigeration

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

Transcription:

2422 Page 1 HFO-1234yf Performance in a Beverage Cooler Barbara MINOR 1 *, Carlos MONTOYA 2, Francisco Sandoval KASA 3 1 DuPont Fluoroproducts, Wilmington, DE, USA Phone: 302-999-2802, E-mail: barbara.h.minor@usa.dupont.com 2 Femsa, San Juan del Rio, Qro, Mexico Phone: +52 427 2718009, E-mail: carlos.montoya@efemsa.com 3 Femsa, San Juan del Rio, Qro, Mexico Phone: +52 427 2718031, E-mail: francisco.sandoval@efemsa.com ABSTRACT HFO-1234yf is a low global warming potential refrigerant that has been selected as the preferred option to replace R-134a in automotive air conditioning systems. It was primarily chosen over carbon dioxide due to its higher energy efficiency and improved Life Cycle Climate Performance (LCCP) (SAE, 2009 and Little, 2002). It is also a close thermodynamic match to R-134a which results in fewer system modifications and potential for global implementation in auto a/c systems. The question arising given the success in automotive is whether HFO-1234yf can be used in other applications where R-134a is currently employed. In particular, vending machines and beverage coolers account for a substantial portion of R-134a use. There are over 10 million vending machines installed worldwide and a significant number of these are beverage coolers (WVA, 2010). This paper will explore the potential to use HFO-1234yf in a beverage cooler through design optimization and experimental system testing. Performance will be compared to an R-134a baseline and two systems optimized for carbon dioxide. Results will also be used in an LCCP analysis to evaluate overall environmental impact of the three options. 1. INTRODUCTION Due to increasing concern over climate change, the European Commission has mandated a phase out for R-134a refrigerant in air conditioning in new car platforms in EU countries starting January 1, 2011. R-134a has a 100 year global warming potential value (GWP) of 1430 according to the Intergovernmental Panel on Climate Change 4 th Assessment Report (Solomon et al., 2007). Replacement refrigerants must have a GWP less than 150. Until recently, the leading candidate to replace R-134a had been CO 2 with a GWP of 1. However, CO 2 has several drawbacks including significantly higher pressure and lower thermodynamic cycle efficiency. The large difference in system pressure and transcritical operation requires significant design changes in order to use CO 2. This results in higher cost equipment, reliability questions, and maintenance issues. HFO-1234yf was recently identified and selected as the preferred solution by global automotive OEMs. It has vapor pressure and other properties similar to R-134a, but a 100 year GWP of 4 which meets the EU regulation requirements and also has excellent LCCP because its energy efficiency is similar to R-134a. It has no ozone depletion potential. It is marginally flammable, but extensive risk assessments have demonstrated it can be used safely in auto a/c systems (SAE, 2009). Recent research has begun to focus on the potential to use HFO-1234yf in stationary applications with small charge sizes where the flammability properties of HFO-1234yf can be managed.

2422 Page 2 The purpose of this paper is to report on experimental cooling performance evaluation of R-134a, HFO-1234yf and CO2 in beverage coolers. A standard beverage cooler design was chosen and coolers were optimized for each specific refrigerant. Results were then used to calculate an LCCP value for each refrigerant option. 2. THERMODYNAMIC CYCLE ANALYSIS To begin the study, a thermodynamic cycle analysis was conducted for R-134a, HFO-1234yf and CO 2. Evaporator and condenser temperatures were chosen to represent typical beverage cooler HFO-1234yf conditions. A transcritical model was used for CO 2 where pressure was adjusted to determine optimum COP. CO 2 uses a gas cooler in place of a condenser. The gas cooler exit temperature was set to be equivalent to the subcooled condenser temperature of 45 C used for R-134a and HFO-1234yf. Results are shown in Table 1. COP and volumetric cooling capacity for HFO-1234yf are within 3-4% of R-134a indicating a close match in performance. Condenser and evaporator pressures are also quite similar and the compression ratio of HFO-1234yf is slightly less than R-134a. CO 2 shows remarkably different characteristics with significantly higher system pressures, compressor discharge temperature and also higher capacity. The COP is significantly lower than the other refrigerants and only 56% of R- 134a at these conditions. Table 1: Theoretical Cycle Performance Parameter R-134a HFO-1234yf CO 2 Condenser Temp ( C) 50 50 45* Subcool amount (K) 5 5 N/A Evaporator Temp ( C) -5-5 -5 Return Gas Temp ( C) 18 18 18 Compressor Efficiency 75% 75% 75% Condenser Pressure (kpa) 1319 1300 11403 Evaporator Pressure (kpa) 243 264 3055 Compression Ratio 5.43 4.92 3.73 Compressor Disch Temp ( C) 90.4 77.6 143.5 Volumetric Capacity (kj/m3) 1643 1577 9914 COP 2.87 2.77 1.60 Capacity Relative to R-134a 100% 96% 603% COP Relative to R-134a 100% 97% 56% *Gas Cooler Exit Temp ( C) 3. EXPERIMENTAL TESTING Experimental system cooling performance was measured using standard 19 cubic foot (0.54 m 3 ) beverage coolers. One cooler with unchanged design was used as the R-134a baseline. Another cooler was optimized for HFO-1234yf and a third and fourth cooler were optimized for CO 2 using two different compressor types. Design details are shown in Table 2. The main changes involved optimization of the capillary tube length and condenser coil design. HFO-1234yf used a slightly longer capillary tube than R-134a (144 versus 120, 3.66 m versus 3.05 m). For CO 2, one system used a presostatic expansion valve and the other a capillary tube 150 (3.81 m) in length and also with a smaller inner diameter. The fully instrumented coolers were placed in an environmental chamber to allow control of temperature and humidity. Ambient test conditions were 40.6 C and 75% relative humidity.

2422 Page 3 Table 2: Beverage Cooler Description Description R-134a HFO-1234yf CO 2 -A CO 2 -B Refrigerant Charge Size 0.49 kg 0.51 kg 0.480 kg 0.49 kg Cooler Type G3-19 D BMAD G3-19 D BMAD G3-19 Danfoss G3-19 Sanyo Compressor NF8.4FX.2 NF8.4FX.2 TN1416 Danfoss C-C30 Sanyo Condenser coil Danfoss recip 72 tubes, 4 rows, 5/16 Ф Cu tubes w/o Al fins Danfoss recip 72 tubes, 4 rows, 5/16 Ф Cu tubes w/o Al fins recip 40 tubes, 4 rows, 5/16 Ф Cu tubes, 3.5 FPI Al fins two stage 40 tubes, 4 rows, 5/16 Ф Cu tubes, 3.5 FPI Al fins Condenser Fan Motor 9W, ECM 9W, ECM 9W, ECM 9W, ECM Condenser Fan Blade 8.75 Ф - 28-5P 8.75 Ф - 28-5P 8 Ф - 28-5P 8 Ф - 28-5P Evaporator Coil 20 tubes, 4 rows, 3/8 Ф Cu tubes, 5 FPI Al fins 20 tubes, 4 rows, 3/8 Ф Cu tubes, 5 FPI Al fins 20 tubes, 4 rows, 3/8 Ф Cu tubes, 5 FPI Al fins 20 tubes, 4 rows, 3/8 Ф Cu tubes, 5 FPI Al fins Evaporator Fan Motor 9W, ECM 9W, ECM 9W, ECM 9W, ECM Evaporator Fan Blade 8 Ф - 28-5P 8 Ф - 28-5P 8 Ф - 28-5P 8 Ф - 28-5P Capillary Tube 0.049 Ф X 120 long 0.049 Ф X 144 long Presostatic valve 0.031 Ф X 150 long Cooling performance was evaluated several different ways. First, the time was determined to cool an empty beverage cooler to 0 C. Then the cooler was loaded full with a prescribed number of beverage cans at room temperature. The cooler was started and time measured of initial pull down (IPDT Initial Pull Down Time) to condition as well as energy consumed during the pull down. Next, one half of the cans were removed and reloaded with cans at room temperature. Then the pull down time (HRT Half Reload Time) and energy consumption were again measured. Finally steady state energy consumption over a 24 hour period (ECT Energy Consumption Time) with a fully loaded system was measured. Test results are shown in Table 3 below. Table 3: Experimental Beverage Cooler Test Results Description R-134a HFO-1234yf CO 2 -A CO 2 -B No. Cans Loaded 630 630 630 630 Time to Reach 0 C 37 min 37 min 33 min 34 min Empty Initial Pull Down 23 hr, 45 min 23 hr, 40 min 19 hr, 47 min 19 hr, 58 min Time - IPDT Energy Consumed 10.816 10.875 12.520 12.950 IPDT (kw/hr) Half Reload Time 16 hr, 55 min 16 hr, 41 min 11 hr, 24 min 12 hr, 10 min HRT (kw/hr) Energy Consumed 7.254 7.279 8.229 8.739 HRT (kw/hr) Steady State Energy 5.784 5.798 7.996 8.290 Consumption ECT (kw/hr) ECT Rel to R-134a 100% 100.2% 138.2% 143.3% (%) Energy per can - Watts 9.18 9.20 12.69 13.16 Results show that HFO-1234yf energy performance is very comparable to R-134a for IPDT, HRT and ECT performance. Though CO 2 demonstrates good initial pulldown times, the steady state energy consumption of CO 2 is from 38-43% higher than R-134a.

2422 Page 4 4. FLAMMABILITY CONSIDERATIONS Since HFO-1234yf is marginally flammable, it is subject to industry standards such as European EN 378-1 which have limitations on refrigerant charge size based on room volume (EN 378-1, 2007). Currently, HFO-1234yf would be considered an A2 refrigerant under EN-378-1, though a new classification of 2L for marginal flammability, based on burning velocity <10 cm/s is under consideration. According to EN 378-1, Table C.1, the maximum refrigerant charge for A2 refrigerants is given in Equation (1). maximum refrigerant charge (kg) = practical limit (kg/m 3 ) * room volume (m 3 ) (1) For most flammable refrigerants, the practical limit is defined by EN 378-1 as is 20% of the lower flammability limit (LFL). The LFL for HFO-1234yf is 6.2 vol% in air per ASTM E681-04, 2004 (Minor and Spatz, 2008) which is 0.289 kg/m3. Therefore, the practical limit is 0.0578 kg/m3. The beverage cooler tested contained an HFO- 1234yf charge of 0.51 kg. Therefore, the minimum size room this cooler can be placed in according to EN 378-1 is 0.51/0.0578 = 8.8 m 3. Given an average room height of 2.4 m (8 ft), the room floor area would need to be at least 3.7 m 2 (40 ft 2 ) which is about 2 X 2 m. This represents a very small room which indicates this HFO-1234yf beverage cooler is suitable for use in most rooms per EN 378-1. In the United States, UL Standard 471 (UL 471, 2006), for Commercial Refrigerators and Freezers has a maximum charge limit for A2 refrigerants of 0.225 kg maximum which is more restrictive then EN 378. ASHRAE Std 34 Designation and Safety Classification of Refrigerants (ANSI/ASHRAE Std 34, 2007) was recently revised to incorporate the 2L marginal flammability classification. Therefore, ASHRAE Std 15- Safety Standard for Refrigeration Systems (ANSI/ASHRAE/Std 15, 2007) is currently under review to determine revisions required to employ 2L refrigerants. This could eventually lead to modification of UL 471 and other standards as well. 5. LIFE CYCLE CLIMATE PERFORMANCE Life Cycle Climate Performance, (LCCP) is a widely recognized tool to understand total product environmental impact beyond the direct global warming potential (GWP) of the refrigerant (Hill and Papasavva, 2005 and Little, 2002). This is a cradle-to-grave analysis of the environmental impact at all points in the life cycle chain, including (1) manufacture of refrigerant, (2) energy used during system operation, (3) refrigerant emissions and (4) refrigerant losses at end-of-life disposal. An LCCP analysis was conducted using the steady state energy data from the beverage cooler tests. The results for the two CO 2 beverage cooler systems were averaged in the analysis. The following assumptions were made: - beverage cooler equipment life 10 years - average refrigerant leak rate 15% over 10 years or 1.5% per year - refrigerant loss at end of life 85% of charge LCCP results from the steady state beverage cooler energy test are shown in Figure 1 and 2 below. Figure 1 assumes a CO 2 energy factor for the US of 0.5436 kg CO 2 /kwhr (WRI, 2010). Figure 2 uses the average value for 27 EU countries is Europe at 0.354 kg CO 2 /kwhr (WRI, 2010). Results in Figure 1 and 2 show that contribution from refrigerant manufacture has a negligible impact on LCCP, less than 1% of the total. Refrigerant leakage also has a relatively low impact due to the low leak rate from this type of equipment. The primary contributor to overall climate impact is the energy use or energy efficiency of equipment operation over its lifetime. For both the US and the EU, results show HFO-1234yf has the lowest LCCP and is therefore the lowest environmental impact over the lifetime of the system. Overall, the EU values are lower than the US values because less CO 2 is formed during energy production in the EU on average.

2422 Page 5 Kg CO2 Equivalent Over 10 Year Life 18000 16000 14000 12000 10000 8000 6000 4000 2000 0 R-134a CO2 HFO-1234yf Refr Mfr Direct Indirect Figure 1: Beverage Cooler LCCP in the United States Kg CO2 Equivalent Over 10 Year Life 12000 10000 8000 6000 4000 2000 0 R-134a CO2 HFO-1234yf Refr Mfr Direct Indirect Figure 2: Beverage Cooler LCCP in the EU

2422 Page 6 6. CONCLUSIONS HFO-1234yf has significant potential as a new low global warming refrigerant for small stationary applications such as vending machines and beverage coolers. It has excellent environmental properties which can have a long term favorable impact on climate change and meet current and future climate regulations. Test results from beverage coolers optimized for R-134a, HFO-1234yf and CO 2 demonstrate that coolers can be designed for HFO-1234yf that demonstrate similar energy efficiency and cooling capacity compared to R-134a. Only minor modifications were required to achieve equivalent performance. HFO-1234yf also has the lowest LCCP giving it the most favorable environmental profile due to its energy efficiency and low direct GWP. Though HFO-1234yf is marginally flammable, risk assessments have demonstrated it can be used safely in automotive air conditioning systems. Standards development for commercial stationary refrigeration systems is in progress which will help define use requirements for 2L refrigerants. REFERENCES ANSI/ASHRAE Standard 15-2007, 2007, Safety Standard for Refrigerating Systems. ANSI/ASHRAE Standard 34-2007, 2007, Designation and Safety Classification of Refrigerants. ASTM E681-04, 2004 "Standard Test Method for Concentration Limits of Flammability of Chemicals (Vapors and Gases)," American Society for Testing and Materials (ASTM), West Conshohocken, PA. EN-378-1, 2007, Refrigerating Systems and Heat Pumps Safety and Environmental Requirements Part 1: Basic Requirements, Definitions, Classification and Selection Criteria. Little, A. D., 2002, Global Comparative Analysis of HFC and Alternative Technologies for Refrigeration, Air Conditioning, Foam, Solvent, Aerosol Propellant and Fire Protection Applications, Final Report to the Alliance for Responsible Atmospheric Policy. Hill, W. and S. Papasavva, 2005, Update of Life Cycle Analysis of Alternate Refrigerants base on SAE Improved Mobile Air Conditioning Cooperative Research, presented at First European Mobile Air Conditioning Workshop, Torino, November, 29. Minor, B. and M. Spatz, 2008, HFO-1234yf Low GWP Refrigerant Update, Proceedings of the 12 th International Refrigeration and Air Conditioning Conference at Purdue, West Lafayette, Indiana. SAE, 2009 SAE International Releases Test Results of the Low GWP Refrigerant for Automotive Air Conditioning http://www.sae.org/servlets/pressroom?object_type=pressreleases&page=showrelease&release_id=11 09, November 10, 2009. Solomon, S. et.al. (eds), 2007, Climate Change 2007: The Physical Science Basis. Contribution of Working Group I to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change. Cambridge University Press, Cambridge, United Kingdom and New York, NY, USA. UL 471, 2006, Commercial Refrigerators and Freezers. WRI, 2010, World Resource Institute, http://cait.wri.org/ WVA, 2010, Worldwide Vending Association, http://www.worldwidevending.org/index.php.