ARGO DPM-2 OUTDOOR TEMPERATURE SETBACK CONTROL

Similar documents
ARM SERIES Switching Relays With Priority

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3

ARGO AR SERIES CONTROLS

AR861-2II AR822-II AR861-3II. ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road Dunkirk, NY ARH-1 ARH-2 ARH-3

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

qualified heating installer/service technician

ARGO ZONE VALVE CONTROLS AZ-4CP / AZ-6CP

USER'S INFORMATION MANUAL

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

USER'S INFORMATION MANUAL

Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules

AT SERIES C ELECTRIC BOILERS ABSOLUTE EFFICIENCY. TOTAL COMFORT! Save Money, Save Space, Save the Environment! RESIDENTIAL / LIGHT COMMERCIAL

OIL FIRED WARM AIR FURNACE. Homeowner Instructions

H 2. Hot Water Storage/ Booster Tanks. For Single Tank Installations INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

- Data Brochure Mixing Control 360

Stainless Steel Condensing Boiler Connection Instructions To Additional Heating Devices

Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190

Technical Bulletin MODELS AFFECTED SW3, SW3T SW4, SW4T SW5, SW5T

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

USER'S INFORMATION MANUAL

- Data Brochure D 260. Boiler Control /09

- Data Brochure Steam Control 279

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

Outdoor Reset IQ Option Card, p/n

USER'S INFORMATION MANUAL

TB4000 Temperature Controller

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING

Outdoor Reset IQ Option Card, p/n

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Instructions. Easy-wire terminal strip Microprocessor-operated. Easy remote sense. Self-checking program. Diagnostic/status LED s

Installation, Operation & Service Manual

B-40/B-41 Modulating Temperature Controller

TWZ/CT/ODV Series. Oil-Fired Hot Water Boilers (Less Tankless Heater) These instructions must be affixed on or adjacent to the boiler

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

Power Supply Display Module PSDM. Installation and Operation Manual

Multi Boiler Guide. Kit #

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

USER'S INFORMATION MANUAL

! WARNING. Replacement Head Mechanism INSTRUCTION MANUAL MM-413F

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS

TS0 Series Portable Bulb and Capillary

Model 7610 Description / Applications

Installation Instructions

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

Installation Instructions

Outdoor kit. Models: RTG 199HE / RTG 199ME. Installation Instructions

- Data Brochure Mixing Control 361

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

(HSTAT Series) Instruction Manual

Control manual and troubleshooting guide

Safety & Installation Instructions

INSTALLATION INSTRUCTIONS

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

15B Cast Iron Gas Fired Boilers For Forced Hot Water

DXL SERIES II CAST IRON GAS FIRED BOILERS FOR FORCED HOT WATER

Crown Boiler Company

Installation, Start-Up, and Operating Instructions

Remote Relay Module (RRM)

USER'S INFORMATION MANUAL

Installation Instructions

INTELLILEVEL AUTOMATIC WATER LEVELING SYSTEM FOR POOL AND SPA

Product Manual SZ1009

Installation Instructions

BCL-S BFL (Lowboy Model) BCL

Integrated Hood Liner

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

PS SERIES PARALLEL RACK SYSTEM START UP GUIDE

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Manifold Installation Controller MIC-180. Installation and Operation Instructions

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

NO VENTING REQUIRED 120V AC;

HotPoly Tote Tank / IBC Heaters (TTH Series)

FSB Series II Gas-Fired Hot Water Induced Draft Boilers

Low Water Cutoff (LWCO) IQ Option Card p/n , for Hot Water Boilers

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

FPC-02 Series. Installation and Operating manual

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

Installation Instruction

ignored. Denotes content that may result in bodily injury and physical damage when ignored.

CAUTION. Installation Manual

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

BriskHeat NDT Kit for Elevator Inspection

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE 11/03/2015 Rev 00

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Installation Instructions

Transcription:

ARGO OUTDOOR TEMPERATURE SETBACK CONTROL INSTALLATION, OPERATION & MAINTENANCE MANUAL Information and specifications outlined in this manual in effect at the time of printing of this manual. ECR International, Inc. reserves the right to discontinue, change specifications or system design at any time without notice and without incurring any obligation, whatsoever. Manufactured by: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: www.ecrinternational.com www.argocontrols.com P/N 24005132 Rev. B [07/30/2016]

TABLE OF CONTENTS Safety Symbols and Warnings...3 Introduction...3 Product Description and Specifications...3 Control Board Diagram...4 Mounting Instructions...5 Outdoor Sensor Installation...5 Water Supply Sensor Installation...5 Electrical Specifications & Wiring...6 Setup...6 Wiring Applications...7 Sequence of Operation... 10 Troubleshooting... 10 Replacement Parts... 11 Technical Support... 12 Keep this manual near boiler Retain for future reference 2 P/N 240005132, Rev. B [07/15/2016]

!!! WARNING Fire, explosion, asphyxiation and electrical shock hazard. Improper installation could result in death or serious injury. Read this manual and understand all requirements before beginning installation. Become familiar with symbols identifying potential hazards. This is the safety alert symbol. Symbol alerts you to potential personal injury hazards. Obey all safety messages following this symbol to avoid possible injury or death. DANGER Indicates a hazardous situation which, if not avoided, WILL result in death or serious injury WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. DANIMPORTANT: Read and understand the following instructions COMPLETELY before installing!! Introduction This manual is intended to familiarize the installer and user of the Argo Outdoor Temperature Setback Control with its installation and operation to assure normal troublefree operation. Argo controls are designed and manufactured with quality components for maximum life and durability and require minimal service. To ensure a satisfactory installation, it is imperative that the instructions be followed carefully before operating the control. Failure to do so may result in breach of warranty. Product Description And Specifications Outdoor Temperature Setback Control is designed to raise or lower the temperature of boiler supply water based upon a proportionate drop or rise in temperature at the outside sensor. This control plugs into Argo control equipment with a data port or as a stand alone device that can be easily wired into almost any system.! CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE Used to address practices not related to personal injury. 3 P/N 240005132, Rev. B [07/15/2016]

CONTROL BOARD DIAGRAM 1 2 3 4 5 13 6 12 7 8 11 10 9 DIAGRAM KEY 1. Water Sensor Terminal Block 2. Outdoor Sensor Terminal Block 3. Priority Input Terminal Block 4. Priority LED 5. Max. Temp. Trim Pot 6. Differential Trim Pot 7. Reset On LED 8. Power Switch 9. 24 VAC IN /Common Terminal Block 10. To Boiler T-T Terminal Block 11. From T-Stat or X-X Terminal Block 12. Ribbon Cable Data Port 13. Reset Ratio Trim Pot 4 P/N 240005132, Rev. B [07/15/2016]

TECHNICAL SPECIFICATIONS Power Supply: 20-28 VAC / 2 VA Relay Capacity: 24 VAC / 48 VA Sensor: 1005 Ohms at 70 F (accurate up to 500 with 18 gauge wire) *See RTD Sensor Troubleshooting in Section X for more information. Outdoor Sensor Installation It is important to install outdoor sensor (provided with ) on the north side or shaded side of building. Locate minimum of 10 feet above grade and not near any location where internal heat could affect the sensor rating, such as window, doors, exhaust vents or fans. See figure below. ADJUSTMENTS Reset Ratio: 0.5-1.5 Max. Temp: 150-210 Differential: 5-15 Mounting Instructions Mount the Argo Control vertically on a solid wall or partition. For your convenience it is recommended that the control be mounted as close as possible to the device being controlled, however it should never be mounted more then 75 feet away. Select a location that is easily accessible for installation and service. NOTE: To reduce the possible transformer hum and relay noise that is sometimes amplified by mounting surfaces such as sheet metal, plasterboard, and similar materials, place rubber or felt washers between the case and the mounting surface. 1. Position the control and mark the mounting holes. 2. Start screws (not provided) for the keyhole type mounting holes in the upper corner(s). Tighten the screws down to about ⅛ (3mm) from the surface. 3. Hang the control on the screw(s), position the case, and start the bottom screws. 4. Tighten all screws. Water Supply Sensor Installation Install supply water sensor on common header within 5 feet of supply water tapping in the boiler. See figure below. 5 P/N 240005132, Rev. B [07/15/2016]

Electrical Specifications & Wiring! General Wiring Notice WARNING Electrical shock hazard. Disconnect power before installing or servicing. Failure to follow these instructions could result in death or serious injury. All primary wiring must be 14 AWG minimum. Torque terminal screws 6 to 7 inch pounds. U.S.A. - National Electric Code and any other national, state, or local code requirements. Wiring must be N.E.C. Class 1. CANADA - C.S.A. C22.1 Canadian Electrical Code Part 1 and any other national, provincial, or local code requirements. Wiring must be C.S.A. C22.1 C.E.C. Part 1. Control Set-up 1. Determine the reset ratio and adjust Reset Ratio Trim Pot. If heat curve is unknown, try ratio of 1.0. 2. Turn Max. Temp. Trim Pot to design temperature of supply water (water temperature needed when outdoor temperature is 0 F). IMPORTANT: Boiler high limit must be set higher than Max. Temp. setting plus Differential or unit may operate erratically. 3. Set Differential Trim Pot to scale (10 F). Boiler will turn off when water is 5 F above control point and back on again when water is 5 F below control point. If boiler does Quick Cycle, increase trim pot. Optimal performance is obtained when this setting is as low as possible, but still allows for a reasonable cycle time. SETUP Common Terminology Reset Ratio: The ratio between supply water temperature and outdoor temperature. For example, a ratio of 1.0 or 1:1 means, for every one degree the outdoor temperature decreases, there will be a one degree increase in supply water temperature. Max. Temp: The maximum supply water temperature when the outdoor temperature is 0 F. Differential: Measurement used to determine when the boiler will turn on and off. A ten degree differential will turn the boiler on at five degrees below the control point and off at five degrees above while a twenty degree differential will turn the boiler on at ten degrees above and off at ten below. The effect of differential is to prevent quick cycling of the boiler. 6 P/N 240005132, Rev. B [07/15/2016]

OUTDOOR TEMPERATURE SETBACK CONTROL WITH ARGO AZ-3 ZONE VALVE CONTROL TYPICAL WIRING APPLICATION USING OUTDOOR RESET WITH ARGO AZ-3 ZONE VALVE CONTROL WATER OUTDOOR TRIMPOTS FOR FACTORY CALIBRATION DO NOT USE OUTDOOR RESET CONTROL WATER OUTDOOR INPUT ON 0.6 0.7 0.8 1.0 180 10 0.5 1.5 150 210 5 15 RESET RATIO MAX TEMP DIFF O C W 1 FROM ARM DATA PORT RESET ON REG 2 REG 1 FROM T STAT OR X-X TO T-T BOILER 24VAC COMMON POWER ON To T-T on Boiler Aquastat { L1 (HOT) 120VAC N 40 VA 24V 24 VAC COM X-X T T T ON T T T CIRC END SW 1 END SW 2 X1 X1 X2 X2 ZONE 1 ZONE 2 ZONE 3 1 2 3 4 1 2 3 1 2 3 4 4 AZ-3 Zone Valve Controller 7 P/N 240005132, Rev. B [07/15/2016]

OUTDOOR TEMPERATURE SETBACK CONTROL WITH ARGO AZ-4CP CONTROL WATER } OUTDOOR DO NOT USE TRIMPOTS FOR FACTORY CALIBRATION (DO NOT USE) OUTDOOR RESET CONTROL WATER OUTDOOR INPUT ON 0.6 0.7 0.8 1.0 180 10 0.5 1.5 RESET RATIO 150 210 MAX TEMP 5 15 DIFFERENTIAL ON 1 RESET ON ZONE VALVE / PUMP ZR-ZC RED WIRE RIBBON CABLE MAD T STAT OR X-X TO T-T BOILER 24VAC }DO NOT USE COMMON POWER ON NOTE: REFER TO AZ-CP MANUAL FOR AZ-CP OPERATION OPTION SWITCHES KEY ON OFF AZ-4CP C T T T T T T T T 24 VAC R X X TO STATUS ON PRIMARY PUMP PUMP X-X CONTACT ZR ON Z1 Z2 Z3 Z4 ZONE VALVE / PUMP ZR-ZC L 120 VAC TO XFRM N ZC ON OPTION SWITCHES N 120VAC L PRIMARY PUMP L N PUMP L N FROM BOILER ZR ZC AZ-4CP 1 2 4 3 1 3 2 4 PRI ZONE 1 ZONE 2 1 2 3 4 2 1 3 4 ZONE 3 ZONE 4 8 P/N 240005132, Rev. B [07/15/2016]

OUTDOOR TEMPERATURE SETBACK CONTROL WITH ARGO ARM-4P CONTROL 9 P/N 240005132, Rev. B [07/15/2016]

Sequence of Operation is designed to operate in conjunction with several Argo controls via a ribbon cable but may also be used with other manufacturers controls. The following assumes the application is a ribbon cable to standard zone control. 1. Zone control and boiler should be functioning properly in all respects prior to evaluating the. Remove the ribbon cable and verify proper system operation before continuing. 2. Connect the to the zone control using the supplied ribbon cable in accordance with the wire diagram for your specific application (See Section VIII of this manual for examples.) 3. With the Power On switch in the On position, there should be 24 VAC across the lower terminals labeled 24 VAC and Common. 4. The high limit control on the boiler should be set to a higher temperature than the Max. Temp. setting on the. (See Section VII for more information.) 5. The Priority On LED should be on when the Priority Zone terminals on the zone control are jumped. The small relay near the LED should also be heard energizing. 6. When the Reset On LED is illuminated, the X-X relay on the zone control should be off. When the Reset On LED is off, the X-X relay should be on only if a zone is calling for heat. RTD Sensor Troubleshooting To confirm RTD Sensor is functioning properly: 1. Remove both RTD leads from the terminal block on the control board. 2. Use a multimeter to take an ohm reading across the RTD leads. A properly functioning RTD Sensor will produce a reading of approximately 1005 ohms at 70 F while a faulty RTD will read either 0 or 1. 3. Replace RTD if necessary. Troubleshooting Tips 1. If the setup check is okay, a problem may be due to a faulty sensor, faulty installation, or faulty wiring. 2. Disconnect the sensor wires from the terminals and measure the resistance between the wires. The measured resistance should be within 5% of the values in the table below. If the meter indicates an open or short you might suspect the wiring between the sensor and the. 3. If the outdoor sensor disagrees with another outdoor thermometer, it may be located in direct sunlight. Reposition the sensor if necessary. Do not proceed until both sensors are performing properly. EXAMPLE: If the water sensor reads 1500 ohms and you estimate the water is about 175 F, the water sensor is okay. If the meter reads 1400 ohms or 155 F, you might suspect the thermal connection between sensor and the pipe. OUTDOOR WATER SUPPLY Degrees Ohms Degrees Ohms 5 758 149 1368 14 789 158 1413 23 822 167 1459 32 855 176 1506 41 889 185 1554 50 924 194 1602 59 960 203 1652 68 997 212 1702 77 1035 - - NOTE: The Outdoor Sensor and Water Supply Sensor are interchangeable and may be reversed to assist the troubleshooting process. 10 P/N 240005132, Rev. B [07/15/2016]

Replacement Parts REPLACEMENT PARTS DESCRIPTION PART NUMBER Temperature Sensor Z63 Outdoor Sensor Shield S60 11 P/N 240005132, Rev. B [07/15/2016]

Technical Support For technical support on this and all Argo products, please contact ECR International Technical Service at 1-800-325-5479. Please have your model number available when calling. Model Number Installation Date Information Needed When Calling Installer ECR International 2201 Dwyer Avenue Utica, NY 13501 www.ecrinternational.com www.argocontrols.com