qualified heating installer/service technician

Similar documents
Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules

ARGO DPM-2 OUTDOOR TEMPERATURE SETBACK CONTROL

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road

AR861-2II AR822-II AR861-3II. ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road Dunkirk, NY ARH-1 ARH-2 ARH-3

WARNING WARNING. Temperature Control for Weil-McLain Aqua Plus Indirect Water Heater

- Data Brochure D 260. Boiler Control /09

ARM SERIES Switching Relays With Priority

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

INSTALLATION/OPERATING INSTRUCTIONS HEAT-TROL Elite Series. HWE-Motorized Valve

LGB. Control Supplement. Gas fired boiler. Universal Control System. Series 2 Propane gas. Contents

ECO1ZN3P, ECO2ZN4P ECO

Boiler Manual. Gas-fired water boilers. Featuring. Flexibility

Outdoor Reset IQ Option Card, p/n

Outdoor Reset IQ Option Card, p/n

- Data Brochure Steam Control 279

- Data Brochure Mixing Control 360

Hydronic Mechanical Panels

Boiler Manual. Oil-Fired Water Boilers. Maintenance Parts. Installation Startup

prestige Control Application Supplement - TriMax

Boiler Manual. Oil-Fired Steam Boilers. Maintenance Parts. Installation Startup

Boiler Manual. Series 3 Oil-Fired Water Boilers. Installation Maintenance Parts

prestige Control Application Supplement - TriMax

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override

LGB Gas fired boiler

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

Boiler Manual. Series 3 Oil-Fired Water Boilers. Installation Maintenance Parts

- Data Brochure Universal Reset Module 422

CER Series 2. Installation Instructions. Electric-Hydronic Boilers. Installer

- Data Brochure Universal Reset Module 423

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Product Instructions. Basic Digital Snow Melt Control II. Applications. Features. Specifications

Indirect-Fired Water Heaters

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

- Data Brochure Mixing Control 361

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER

WWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

BB3000 Series. Application. Features. Injection Pump Control General Instructions

Radiant Mixing Block

INSTALLATION INSTRUCTIONS WINTER/SUMMER KIT

GOLD CGt. User s Information Manual. Natural gas-fired water boiler with tankless heater

Boiler Manual. Gas-Fired Water Boilers. Maintenance Parts. Installation Startup

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.

- Data Brochure Boiler Control 274

Installation & Operation Manual

ARGO AR SERIES CONTROLS

HWE-SS DIGI-El i t e Hydronic Single-Stage Boiler Control

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

GOLD Plus 30/40/60/80

Control Application. Supplement - ACVMax

Powers Controls ET 134 Low Temperature Detection Thermostat

User s Information Manual

Boiler Manual. Commercial Condensing Gas-fired water boilers

Dual Mixing Application

- Data Brochure Boiler Control 264

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

Table of Contents. Installation, Operation, and Maintenance Manual V100 Series

B-40/B-41 Modulating Temperature Controller

CER Series 2. Installation Instructions. Electric-Hydronic Boilers. Installer

SC2000 CONTROLLER INSTALLATION AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS

prestige Control Application Supplement - ACVMax

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

Venting Supplement Saf-T Vent 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting Hazard definitions

User s Information Manual

INSTALLATION AND OPERATION INSTRUCTIONS. Hydronic Multi-Stage Boiler Control

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

User s Information Manual

Thermostatic Radiator Valves (Caleffi)

INSTALLATION INSTRUCTIONS

Energy Manager INSTALLATION INSTRUCTIONS. Keep these instructions with the boiler at all times for future reference

Installation & Operation Manual

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

EGH Series 5. Control Supplement. EGH-105 to EGH-125 Natural gas CSD-1 control system

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

TB4000 Temperature Controller

Product Manual. Series 2 Indirect-Fired Water Heaters. Maintenance Parts. Installation Startup

Addendum H to Brute LX 1295A Document 1372

INSTALLATION/OPERATING INSTRUCTIONS SEQUENCING PANELS

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

User s Information Manual

Operator: Save these instructions for future use!

- Data Brochure Mixing Control 360e

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Installation & Operation Manual

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Instructions. Easy-wire terminal strip Microprocessor-operated. Easy remote sense. Self-checking program. Diagnostic/status LED s

GOLD GV. Venting Supplement. Water boiler Series 3. Special gas vent system vent and combustion air supplement. Hazard definitions.

Transcription:

Instruction manual This manual must only be used by a qualified heating installer/service technician. Failure to comply could result in severe personal injury, death or substantial property damage. Part Number 550-141-860/0107

WM-ODR Outdoor Reset Control WM-ODR Outdoor reset control The WM-ODR Outdoor Reset Control is a cost-effective answer for outdoor reset and may conserve energy when installed on most heating systems. The WM-ODR Outdoor Reset Control is designed to raise or lower the temperature of the boiler supply water based upon a proportionate drop or rise in temperature at the outside sensor. The WM-ODR Outdoor Reset Control provides settings for: maximum boiler water operating temperature (Max Temp dial) reset ratio (Reset Ratio dial) differential (Differential dial). Also included are: Indicator lights On-off switch Terminals for connection to Weil-McLain Zone Controllers. Priority override feature automatically disables reset when the Priority Heating Zone (Domestic Hot Water) calls for heat. The WM-ODR plugs into Weil-McLain WMCR Circulator Zone Controllers and can be hard-wired into Weil-McLain WMZV Zone Valve Controllers. The WM-ODR Outdoor Reset Control is shipped complete with wiring harness, strap-on water supply sensor, outdoor sensor and sunshield. Hazard definitions Indicates presence of hazards that will cause severe personal injury, death or substantial property damage. Indicates presence of hazards that can cause severe personal injury, death or substantial property damage. Indicates presence of hazards that will or can cause minor personal injury or property damage. Indicates special instructions on installation, operation or maintenance that are important but not related to personal injury or property damage. 2

Instruction manual Specifications Reset Ratio Adjustments Max Differential Temp Power supply 0.5 to 1.5 150 to 210 5 to 15 20-28 VAC 2 VA Technical specifications Relay capacity 24 VAC 48VA Sensor (1000 ohms @ 70 F) Accurate up to 500 ft with 18 gauge wire Replacement parts Part description Weil-McLain part number Ribbon cable 591-850-079 2-Wire water temperature sensor 511-724-279 2-Wire outdoor sensor with housing 511-724-280 3

WM-ODR Outdoor Reset Control Installation Outdoor sensor When applying outdoor reset to a hydronic system, review boiler instruction manual for any special piping requirements needed for low temperature operation. Outdoor reset controls will cause sustained operation below 140 F. Failure to pipe boiler in accordance with boiler manufacturer s recommendations could result in damage to the boiler, causing severe personal injury, death or substantial property damage. Install on the North side or a shaded side of the building. Locate a minimum of 10 feet above grade or 3 feet above anticipated maximum snow level and not near any place where internal heat could affect the sensor reading, such as windows, doors, exhaust vents or fans. Figure 1 Outdoor sensor installation Locate outdoor sensor on North wall no exposure to sunlight Outdoor sensor Prevent outdoor sensor from being covered by snow. The sensor would be unable to correctly sense outdoor temperature, causing possible incorrect system water temperature regulation. Conduit (by others) Conduit clamp (by others) 86003 Water sensor Install the water sensor on the common supply header. Figure 2 Water supply sensor installation Strap sensor to main supply from boiler using nylon cable tie. 86004 Wrap sensor and pipe with pipe insulation (by others) to assure sensor will correctly sense water temp. 4

Instruction manual Setup Reset Ratio ① Determine ratio and adjust Reset Ratio dial (if heat curve is unknown, try 1.0 ratio). The Max Temp ② Set Max Temp to the supply water temperature needed at design outdoor temperature. reset ratio dial number is the number of degrees ( F) the supply temperature control point will change for each 1 F change in outdoor temperature. See page 8 for more information. This will be the maximum temperature called for by the WM-ODR Outdoor Reset Control. The boiler high limit must be set higher than the Max Temp setting. Differential ③ Set the Differential Trim Pot to midscale (10 F). The boiler will turn off when the water is 10 F above the control point and turns back on when the water is 10 F below the control point. The effect of differential is to prevent quick cycling of the boiler. If the boiler does quick cycle, increase the Differential setting. Optimal performance is obtained when this setting is as low as possible, but still allows for reasonable cycle time. ④ Do not use trim pots in the upper left corner of the control. These must be used only for factory calibration. 5

WMODR Outdoor R eset Control WM-ODR Reset Wiring Figure 3 Typical wiring WM-ODR Outdoor Reset Control with WMCR-4 Circulator Zone Controller NOTE: Add jumper between ZC and L when using WMCR with WM-ODR. Electrical shock hazard Disconnect power before installing or servicing. Can cause severe personal injury, death or substantial property damage if ignored. All wiring must be installed in accordance with: U.S.A. National Electrical Code and any other national, state or local code requirements. Wiring must be N.E.C. Class 1. Canada C.S.A. C22.1 Canadian Electrical Code Part 1 and any other national, provincial or local code requirements. Wiring must be C.S.A. C22.1 C.E.C. Part 1. Refer to Weil-McLain WMCR Circulator Zone Controller manual for details. Consult boiler manufacturer s manual for recommended piping and application information. 6

Instruction manual Figure 4 Typical wiring WM-ODR Outdoor Reset Controller with WMZV-4 Zone Valve Controller Electrical shock hazard Disconnect power before installing or servicing. Can cause severe personal injury, death or substantial property damage if ignored. All wiring must be installed in accordance with: U.S.A. National Electrical Code and any other national, state or local code requirements. Wiring must be N.E.C. Class 1. Canada C.S.A. C22.1 Canadian Electrical Code Part 1 and any other national, provincial or local code requirements. Wiring must be C.S.A. C22.1 C.E.C. Part 1. Refer to Weil-McLain WMZV Zone Valve Controller manual for details. Consult boiler manufacturer s manual for recommended piping and application information. 7

WM-ODR Outdoor Reset Control Settings To obtain the best operation from a reset control, it is important to monitor the system supply temperature as accurately as possible. The system pump must be operating to maintain continuous water flow across the supply temperature sensor. Heating Curve (Reset Ratio) As outdoor temperature drops, heat loss from a space becomes greater, and the heating system supply water temperature must be increased to maintain a constant room temperature. The heating curve value (Reset Ratio) describes how many degrees the supply water temperature is raised for a one degree drop in outdoor temperature. The supply temperature starts to increase when the outdoor temperature falls below 70 F. To calculate the correct setting for the heating curve, use the Reset Ratio formula, below right. If the actual Design supply water temperature for a system is unknown, calculate a trial setting for Reset Ratio using these typical supply temperatures: Fan coils 180 F to 210 F Baseboard convectors 160 F to 190 F Radiant floors, typical 100 F to 130 F Reset Ratio = Design supply temperature - 70 F 70 F - Design outdoor temperature Example: Design outdoor temperature = 5 F Design supply temperature = 160 F Reset Ratio = 160 F - 70 F 70 F - 5 F = 90 F 65 F = 1.4 8 Part Number 550-141-860/0107