ULTRAVIOLET SANITARY CONDIT IONERS

Similar documents
Model 2-OZ, 3-OZ. Model 6-OZ. free standing, wall, or ceiling mount

GERMICIDAL ULTRAVIOLET FIXTURES

Model LIND30-EVO. Model. Model LIND24-EVO LIND24-EVO-2PM

Model D24-1S. Model D24-2S

Model RS72. Model RSCS280A. Model RSM2680

GERMICIDAL ULTRAVIOLET IRRADIATORS

ULTRAVIOLET PORTABLE AREA SANITIZER

ULTRAVIOLET INDIRECT AIR DISINFECTION

ultraviolet.com Effective Virtually all microorganisms are susceptible to MIGHTY PURE TM ultraviolet disinfection.

Models 2B-SC, 3B-SC, 4B-SC, 4B-ASC, 5B-SC, 5B-ASC, 6B-SC, 6B-ASC. Models 2B-SC, 3B-SC. Models 6B-ASC. Installation, Operation & Maintenance

7-ASC / 8-ASC / 9-ASC

Document No C Revised January Atlantic Ultraviolet Corporation

NO4G, NO4GS, NO6G, NO6GS

Document No A3 Revised February Atlantic Ultraviolet Corporation

Document No A9 Revised August Atlantic Ultraviolet Corporation

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

Model AD30-2. Document No B3 Revised November Atlantic Ultraviolet Corporation

Owner s Manual. Installation, Operation & Maintenance. Models B B B3 RoHS

Document No B Revised June Atlantic Ultraviolet Corporation

Document No B1 February Atlantic Ultraviolet Corporation

Owner s Manual. Installation, Operation & Maintenance. Model G48HO Remote Controlled Sanitizer

Document No A1 Revised September Atlantic Ultraviolet Corporation

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

Ballast 230v 50/60Hz MIN B B MIN B B MIN B B

Ultraviolet Air Disinfection Equipment

Liquid Storage Tank Conditioners

Bio-Logic. Owner s Manual. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Ballast 120v 50/60 Hz

Purifying air at the. Light. speed of. Carrier Corporation 2007 is a member of the United Technologies Corporation family, stock symbol UTX.

Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

S17A, S23A, S37C & S50C

A measured step forward

Models 120v 50/60 Hz 230v 50/60Hz MIN B A MIN B A MIN B A

Models S2400C, S5,000C S25,000C High Capacity Systems. Read and Follow All Safety Instructions. Save These Instructions.

STANDARD SINGLE UV GERMICIDAL CLEANING DELUXE DUAL UV GERMICIDAL CLEANING PREMIUM DUAL UV GERMICIDAL CLEANING

ULTRAVIOLET WATER PURIFIERS

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

Ballast MIN A

PCO/UV N-Duct Model. Owner s Guide

1020 Industrial Drive, Orlinda, TN fax

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

ULTRAVIOLET WATER PURIFIERS

375 Marcus Boulevard Hauppauge, NY USA Fax: Extensive Product Information Available at:

GRU-V Air Purifier. Product Manual

Owner s Manual MIGHTY PURE. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Models MP16A, MP22A, MP36C & MP49C

PURION UV plants for disinfection

ULTRA-VIOLET STERILIZATION

AMERICAN AIR & WATER, INC.

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

Owners Manual Model: XXL

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

RS4 Whole House IAQ System

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Document No E1 Revised February Atlantic Ultraviolet Corporation

SmartStream UV. Ultraviolet Water Disinfection System. Maximize Water Quality Without Chemicals. Watts.com

Biological Safety Cabinets or Fume Hoods Which one to use?

PURPOSE OF THE PROCEDURE

Owner s Manual. Installation, Operation & Maintenance. Models S17A, S23A, S37C & S50C U LTRAVIOLET WATER PURIFIERS

Owner s Manual. Installation, Operation & Maintenance. Models S2400C, S5000C, S15000C, S20000C & S25,000C High Capacity Systems

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

Cleans and sanitizes CPAP mask and accessories. Lumin USER MANUAL.

Model CWA200 Owner s Manual

healthy comfort Indoor Air Quality Solutions

February Guide to using germicidal UV. Part of the the Search, Treat, Prevent Comprehensive Approach for TB

254 Nanometer Germicidal UV Disinfection Systems

Section 3: Ultraviolet - UV

Labconco XPress Laboratory Equipment Where You Need It, When You Need It

LOCK H M L REPLACE SLEEPING ANTI-POLLEN IONIZER UV-LAMP. User Manual

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

INSECT REARING CHAMBERS

AIR PURIFIER WITH GERMICIDAL UV LIGHT

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

Customized Drinking Water

OptiVenn TM Series INDUSTRIAL UV SYSTEMS. High performance, cost-effective system for stringent Industrial applications

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

UVC in the Operating Room.

HF Series R_RevB

PureAir Air Purification System PCO-12C/20C

NEW GREEN SERIES INSTALLATION AND OPERATION SP-150GS SP-200GS. Manufactured by ULTRA-SUN TECHNOLOGIES, INC Stellar Court Corona, CA 92883

Healthy, clean air for your home

Introducing the most technically advanced indoor air treatment system

Problem: How can the air, and surfaces, be cleaned to lower the risk from the usual suspects?

Ultraviolet Lights on Daikin Applied Rooftop Systems and Rooftop Air Handlers

UVP, Inc. Ultra-Violet Products Ltd., Unit W 11th Street, Upland, CA Trinity Hall Farm Estate, Nuffield Road

HEALTHY CLIMATE PureAir Air Purification System

Ultraviolet (UV) Monitoring System - Open Channel Horizontal Systems Operation and Maintenance Manual

Professional Amalgam Non-regulated

Infrared Heaters For Controlled Concentrated Curing

How to comply with CDC Guidelines

PCR UV cabinets DNA/RNA

USE & CARE INSTRUCTIONS

Perfect Air Purifiers

Safe Operating Procedure (Revised 2/10)

Supplement 3: Engineering Controls

Safety Manual Section 15 Radiation Safety

Instruction Manual E4 ChamberIR Heater

healthy comfort Indoor Air Quality Solutions

Intensive UV light means not a chance for germs!

PCR UV cabinets DNA/RNA

ULTRAVIOLET WATER TREATMENT

Transcription:

ULTRAVIOLET SANITARY CONDIT IONERS 2B-SC, 3B-SC 4B-ASC, 5B-ASC 6B-ASC

ABOUT US GERMICIDAL ULTRAVIOLET Since 1963, Atlantic Ultraviolet Corporation has pioneered the discovery and development of beneficial uses of ultraviolet energy. Over the years these efforts have led to the development of valuable, cost effective and environmentally sound techniques and products now known and respected throughout the world. Atlantic Ultraviolet s application specialists assist customers in the selection of Ultraviolet is a unique and rapid method of disinfection utilizing germicidal ultraviolet lamps that produce short-wave radiation at 254 nanometers (nm) that is lethal to bacteria, virus and other microorganisms. An ever growing range of industries and consumer applications have found ultraviolet to be the ideal solution for their air treatment needs. germicidal lamps and equipment. Their specialized knowledge is a valuable resource in formulating effective and cost-conscious ultraviolet solutions. Extensive inventories and a dedicated staff enable Atlantic Ultraviolet to fulfill its commitment to Atlantic Ultraviolet equipment and systems are manufactured in the USA. provide fast deliveries and responsive customer service. 2B-SC, 3B-SC 4B-ASC, 5B-ASC 6B-ASC 2

ADVANTAGES PRINCIPLE OF OPERATION Economical System requires very little power to operate. Safe The Nutripure has been carefully conceived to provide adequate germicidal ultraviolet exposure for air disinfection. The treated air is used in the head space of liquid storage tanks helping to prevent condensation. The dosage, as it applies to ultraviolet disinfection, is a function of time, and the intensity, of ultraviolet radiation, to which the air is exposed. Our UV application specialists would be happy to perform the necessary calculations to ensure the unit we provide is appropriate for your particular application. No risk of over-exposure. Nutripure Tank Vent Nutripure Ultraviolet Sanitary Conditioner Fast Air Flow Air Flow Air Flow Disinfects air in seconds. Automatic Air Flow Air Flow Continuous disinfection without AIR SPACE special attention. Durable Polished Stainless Steel Cabinet. LIQUID SWEETENER Figure 1 - Nutripure Ultraviolet Sanitary Conditioner mounted on a liquid sugar tank Versatile Numerous models available to handle various configurations. Low Maintenance Periodic lamp replacement and filter cleaning or replacement is required. The operation of the Nutripure is as follows: 1. Air is drawn into the Nutripure Ultraviolet Sanitary Conditioner through the electrostatic filter. 2. The air is forced into the ultraviolet exposure chamber where it is irradiated by germicidal ultraviolet light (lamp quantity varies per model). These special lamps generate high levels of germicidal ultraviolet radiation lethal to infectious microorganisms such as bacteria, molds and viruses, and once exposed, they are inactivated. 3. Observation Port/Sight Glass provides positive indication of germicidal lamp operation. 4. On models with a HEPA Absolute filter, the irradiated air is then forced through this additional filter which removes more that 99.97% of particles as small as 0.3 microns. 5. Circulation of purified filtered air within the tank head space reduces condensation which can be detrimental to the liquid integrity. 6. Air is exhausted out of the tank through a filtered tank vent. ultraviolet.com buyultraviolet.com 3

SPECIAL FEATURES Nutripure 2B-SC and 3B-SC Ultraviolet Sanitary Conditioners Nutripure Ultraviolet Sanitary Conditioners have long been used commercially to ventilate the air space above the liquid in storage tanks. The purpose of this equipment is to provide a sterile condition in the tank head space, defeat contamination from airborne sources and lower condensation levels which can dilute the tank contents. When diluted, some liquids have a strong tendency to promote the growth of bacteria and mold on the liquid surface. The Nutripure Ultraviolet Sanitary Conditioner ensures that bacteria-free air is used to provide a sanitary environment inside the tank. The Nutripure Ultraviolet Sanitary Conditioner forces bacteria-free air into the air space above the liquid in the storage tank and the tank vent provides an outlet for this air, while at the same time preventing contaminants, insects or debris from entering the storage tank. Nutripure Ultraviolet Sanitary Conditioners utilize STER-L-RAY germicidal lamps which are completely enclosed within a stainless steel exposure chamber and are safe for use in storage tank applications. (without ArmorLite TM ) (with ArmorLite TM ) STER-L-RAY Instant Start Germicidal Lamp(s) STER-L-RAY Germicidal Lamp(s) are instant starting and provide the utmost in quality, sustained output and longevity. ArmorLite Safety Shield protective coating is applied to all STER-L-RAY Germicidal Lamps installed in Nutripure Ultraviolet Sanitary Conditioners to ensure protection for employees, products and work environments by eliminating the dangers associated with fragments of broken lamps and mercury contamination. Steadfast Lampholders Set includes a stationary and a spring-loaded, telescopic holder that grasps a single pin lamp securely. The spring-loaded feature on one end facilitates convenient, quick and easy lamp changes. Interlock Safety Switch The interlock safety switch is a standard feature that disconnects power to the unit when the access panel is unhinged for lamp or filter replacement. Particulate Filter Washable Electrostatic Filter. 2B-SC, 3B-SC (see page 10 for Optional Accessories) Polished Reflector Interior surface is polished aluminum providing a highly reflective surface to maximize ultraviolet intensity within the chamber. Observation Port/Sight Glass Assembly A Sight Glass Assembly allows for a safe visual inspection of the operation of the lamp(s). Stainless Steel Enclosure The unit is manufactured in Type 304 stainless steel for unparalleled strength, durability and an attractive finish. 4

SPECIFICATIONS Figure 2 - Nutripure 2B-SC Ultraviolet Sanitary Conditioner (shown) Nutripure 2B-SC and 3B-SC Ultraviolet Sanitary Conditioners are connected directly to liquid storage tanks. Pipe collar, pedestal leg assemblies and lamp(s)(not shown) are included. The Nutripure Tank Vent is an optional accessory. (See below for more information.) SPECIFICATIONS - Nutripure 2B-SC and 3B-SC Ultraviolet Sanitary Conditioners Tank Size (Gallons) Dimensions Length Width Height Free Air Displacement (cfm) Volts Power Requirements (Amps) 2B-SC up to 6,000 34-1/2 7-3/4 7-3/4 72 120 1.3 3B-SC 7,000-18,000 34-1/2 7-3/4 7-3/4 140 120 2.9 MMUnit capacity incorporates an estimated allowance for airflow friction loss across filter and unit. NNInformation listed refers to 120 Volt 60 Hz units. Contact factory for specifics on other voltages. Genuine STER-L-RAY Germicidal Lamp Data Lamp No. Lamp Length Lamp Watts (Quantity) Ultraviolet Output Rated Average Effective Life 2B-SC 05-6011 21-7/8 (556 mm) 26 (1) 8.5 Watts 10,000 hrs 3B-SC 05-6011 21-7/8 (556 mm) 26 (2) 17 Watts 10,000 hrs MMUltraviolet Output at 254 nanometers at 100 hours and 80 degrees F (approximate). NNSome industries suggest lamp replacement every 6 months to meet specific compliance standards. SPECIFICATIONS - Nutripure Tank Vent (optional) Tank Vent Dimensions Length Width Height 2B-SC/3B-SC 2-TV 6-1/32 7-3/4 7-3/4 ultraviolet.com buyultraviolet.com 5

SPECIAL FEATURES Nutripure 4B-SC, 4B-ASC, 5B-SC, 5B-ASC, 6B-SC and 6B-ASC Ultraviolet Sanitary Conditioners Nutripure Ultraviolet Sanitary Conditioners have long been used commercially by manufacturers of food, pharmaceuticals and beverages to circulate purified filtered air within the tank head space. The purpose of this equipment is to provide a sterile condition in the tank head space, defeat contamination from airborne sources and lower condensation levels which can dilute sweeteners, oils and other liquids. When diluted, sweeteners and oils have a strong tendency to promote the growth of bacteria and mold on the liquid surface. The Nutripure Ultraviolet Sanitary Conditioner ensures that bacteria-free air is used to provide a sanitary environment inside the tank. The Nutripure Ultraviolet Sanitary Conditioner forces bacteria-free air into the air space above the liquid in the storage tank and the tank vent provides an outlet for this air, while at the same time preventing contaminants, insects or debris from entering the storage tank. Nutripure Ultraviolet Sanitary Conditioners utilize STER-L-RAY germicidal lamps which are completely enclosed within a stainless steel exposure chamber and are safe for use in storage tank applications. (without ArmorLite TM ) (with ArmorLite TM ) STER-L-RAY Instant Start Germicidal Lamp(s) STER-L-RAY Germicidal Lamp(s) are instant starting and provide the utmost in quality, sustained output and longevity. ArmorLite Safety Shield protective coating is applied to all STER-L-RAY Germicidal Lamps installed in Nutripure Ultraviolet Sanitary Conditioners to ensure protection for employees, products and work environments by eliminating the dangers associated with fragments of broken lamps and mercury contamination. Steadfast Lampholders Set includes a stationary and a spring-loaded, telescopic holder that grasps a single pin lamp securely. The spring-loaded feature on one end facilitates convenient, quick and easy lamp changes. Interlock Safety Switch The interlock safety switch is a standard feature that disconnects power to the unit when the access panel is unhinged for lamp or filter replacement. Particulate Filter Washable Electrostatic Filter. 4B-ASC, 5B-ASC (s with ASC include Absolute HEPA Filter) Observation Port / Sight Glass Assembly A Sight Glass Assembly allows for a safe visual inspection of the operation of the lamp(s). HEPA Filter s 4B-ASC, 5B-ASC & 6B-ASC include HEPA (Absolute Filter) which removes 99.97% of particles as small as 0.3 microns. 6B-ASC (s with ASC include Absolute HEPA Filter) Stainless Steel Enclosure The unit is manufactured in Type 304 stainless steel for unparalleled strength, durability and an attractive finish. Polished Reflector Interior surface is polished aluminum providing a highly reflective surface to maximize ultraviolet intensity within the chamber. 6

SPECIFICATIONS Nutripure 4B-SC, 4B-ASC, 5B-SC, 5B-ASC, 6B-SC and 6B-ASC Ultraviolet Sanitary Conditioners are mounted directly on liquid storage tanks or installed adjacent to tank with interconnecting pipe. Pipe collar, pedestal leg assemblies and lamps (not shown) are included. The Nutripure Tank Vent is an optional accessory. (See below for more information.) Figure 3 - Nutripure 4B-ASC Ultraviolet Sanitary Conditioner (shown) (s with ASC include Absolute HEPA Filter) SPECIFICATIONS Nutripure 4B-SC, 4B-ASC, 5B-SC, 5B-ASC, 6B-SC and 6B-ASC Dimensions Tank Size o Free Air Displacement Volts Power Requirements (Gallons) Length Width Height 4B-SC up to 6,000 32 72 120 2.0 4B-ASC up to 6,000 48 72 120 2.0 5B-SC 6,000-15,000 32 140 120 2.9 5B-ASC 6,000-15,000 48 140 120 2.9 6B-SC 15,000 to 30,000 46-1/16 14-1/4 12-1/6 295 / 435 120 4.93 6B-ASC 15,000 to 30,000 61-7/16 14-1/4 12-1/6 545 / 760 120 5.86 (cfm) (Amps) MMUnit capacity incorporates an estimated allowance for airflow friction loss across filter and unit NNInformation listed refers to 120 Volt 60 Hz units. Contact factory for specifics on other voltages. OOSpecifically recommended for liquid sugar storage tanks. Genuine STER-L-RAY Germicidal Lamp Data (Quantity) Ultraviolet Output Rated Average Effective Life 21-7/8 (556 mm) 26 (1) 8.5 Watts 10,000 hrs 05-6011 21-7/8 (556 mm) 26 (2) 17 Watts 10,000 hrs 05-6013 27-7/8 (708 mm) 32 (4) 44.8 Watts 10,000 hrs Lamp No. Lamp Length 05-6011 5B-SC/5B-ASC 6B-SC/6B-ASC 4B-SC/4B-ASC Lamp Watts MMUltraviolet Output at 254 nanometers at 100 hours and 80 degrees F (approximate). NNSome industries suggest lamp replacement every 6 months to meet specific compliance standards. SPECIFICATIONS Nutripure Tank Vent (optional) Tank Vent Dimensions Length Width Height 4B-SC / 4B-ASC, 5B-SC / 5B-ASC 4-TV 6 10-1/8 10-1/16 4B-ASC / 5B-ASC / 6B-ASC 4-ATV 16-1/4 6B-SC 6-TV 14-1/2 12-1/4 14-1/4 6B-ASC 6-ATV 22-5/8 12-1/4 12-1/4 ultraviolet.com buyultraviolet.com 7

SPECIAL FEATURES Nutripure 7-ASC, 8-ASC and 9-ASC Ultraviolet Sanitary Conditioners Nutripure Ultraviolet Sanitary Conditioners have long been used commercially by manufacturers of food, pharmaceuticals and beverages to circulate purified filtered air within the tank head space. The purpose of this equipment is to provide a sterile condition in the tank head space, defeat contamination from airborne sources and lower condensation levels which can dilute sweeteners, oils and other liquids. When diluted, sweeteners and oils have a strong tendency to promote the growth of bacteria and mold on the liquid surface. The Nutripure Ultraviolet Sanitary Conditioner ensures that bacteria-free air is used to provide a sanitary environment inside the tank. The Nutripure Ultraviolet Sanitary Conditioner forces bacteria-free air into the air space above the liquid in the storage tank and the tank vent provides an outlet for this air, while at the same time preventing contaminants, insects or debris from entering the storage tank. Nutripure Ultraviolet Sanitary Conditioners utilize STER-L-RAY germicidal lamps which are completely enclosed within a stainless steel exposure chamber and are safe for use in storage tank applications. (without ArmorLite TM ) (with ArmorLite TM ) STER-L-RAY High Output Germicidal Lamps STER-L-RAY High Output (HO) germicidal lamps are similar in size and shape to conventional germicidal lamps but are capable of operating at higher input power and current. ArmorLite Safety Shield protective coating is applied to all STER-L-RAY Germicidal Lamps installed in Nutripure Ultraviolet Sanitary Conditioners to ensure protection for employees, products and work environments by eliminating the dangers associated with fragments of broken lamps and mercury contamination. Interlock Safety Switch The interlock safety switch is a standard feature that disconnects power to the unit when the access panel is unhinged for lamp or filter replacement. Stainless Steel Enclosure The unit is manufactured in Type 304 stainless steel for unparalleled strength, durability and an attractive finish. Steadfast Bayonet Socket Mount Lampholder Bayonet Socket mount four-pin lampholder fastens the lamp securely while providing convenient, "quick and easy" lamp change. Lamp Replacement Indicator Resettable Flashing Light signals reminder for lamp change. HEPA Filter HEPA (Absolute Filter) which removes 99.97% of particles as small as 0.3 microns. 7ASC Particulate Filter Washable Electrostatic Filter. SENTINEL Outlet Connector Allows for easy plug-in and operation of optional SENTINEL Remote Lamp Indicator. Observation Port /Sight Glass Assembly A Sight Glass Assembly allows for a safe visual inspection of the operation of the lamp(s). Polished Reflector Interior surface is polished aluminum providing a highly reflective surface to maximize ultraviolet intensity within the chamber. 8

SPECIFICATIONS Figure 4 - Nutripure 7-ASC Ultraviolet Sanitary Conditioner (shown) Multiple mounting options available for the Nutripure 7-ASC, 8-ASC and 9-ASC Ultraviolet Sanitary Conditioner. SPECIFICATIONS - Nutripure 7-ASC, 8-ASC and 9-ASC Ultraviolet Sanitary Conditioner Tank Size (Gallons) Dimensions Length Width Height Free Air Displacement (cfm) Volts Power Requirements (Amps) 7-ASC 30,000 to 50,000 63-1/8 17-15/16 14-3/8 560 120 50/60Hz 4.66 8-ASC 50,000 to 150,000 74-1/4 21-1/4 20-1/4 1057 120 50/60Hz 10.02 9-ASC 150,000 + 81-15/16 27-3/8 27-7/16 1828 230 50/60Hz 9.75 MMUnit capacity incorporates an estimated allowance for airflow friction loss across filter and unit. GENUINE STER-L-RAY GERMICIDAL LAMP DATA Lamp No. Lamp Length Lamp Watts (Quantity) Ultraviolet Output Rated Average Effective Life 7-ASC 05-6016 691 mm 65 (4) 92 Watts 10,000 hrs 8-ASC 05-6017 843 mm 87 (6) 168 Watts 10,000 hrs 9-ASC 05-6018 843 mm 172 (6) 324 Watts 10,000 hrs MMUltraviolet Output at 254 nanometers at 100 hours and 80 degrees F (approximate). NNSome industries suggest lamp replacement every 6 months to meet specific compliance standards. SPECIFICATIONS - Nutripure Tank Vent (optional) Tank Vent Dimensions Length Width Height 7-ASC 7-TV 30-3/16 15-1/16 12-9/32 9-ASC 9-TV 36.53 39.95 21.45 ultraviolet.com buyultraviolet.com 9

OPTIONAL ACCESSORIES INDUSTRIES SENTINEL Remote Lamp Indicator* The SENTINEL Remote Lamp Indicator monitors lamp operation of one, two, four or six lamp ultraviolet fixtures and is available with a 25, 50 or 100 foot cable. (Available for ALL Nutripure units. Must be ordered at the time of purchase on 2B-SC thru 6B ASC. SENTINEL output connector needs to be installed for easy plug-in and operation. For s 7/8/9 just purchase the optional SENTINEL.) Zenith Ultraviolet Meter A sensitive, hand-held, ultraviolet meter that can be used to: Survey installations to ensure that the germicidal ultraviolet radiant exposure, of personnel within the treated area, is within acceptable limits. The Zenith Ultraviolet Meter provides accurate and easy-to-read levels of intensity that may be interpreted by anyone - not just engineers. Check the intensity of aging ultraviolet lamps (Available for ALL Nutripure units) Integral Elapsed Time Indicator* The Elapsed Time Indicator is a real-time, non-resettable display of accumulated operating time. Useful for scheduling and recording maintenance and lamp replacement. (Available for ALL Nutripure units at time of purchase) Sanitary Adapter (shown with existing collar) 3" and 4" available. Contact factory for alternate inlet/outlet connections. * Item must be ordered at same time as Nutripure Sanitary Conditioner (installed at factory). Liquid sweeteners Corn syrups Sucrose Glucose Fructose Honey Molasses Maple syrup Liquid sugar Edible oil Liquid starches Beverage Dairy Meat Bakery Frozen foods Candy/confectionery Chocolate Pharmaceutical Flavorings Ice cream Snack foods Cookies/crackers Cereal bars Jams/jellies Bread/rolls/pastries Breweries Wineries Distillers/liqueurs Fruit Juice Juice concentrate Bottled water Sports drinks Soda Flavored waters Bottled tea/coffee Canned foods Prepared foods Contract packaging Condiments Vinegar Pickled foods 10

GENUINE STER-L-RAY GERMICIDAL LAMPS Relative Spectral Energy Distribution (Typical) Germicidal Effectiveness As Related to Wavelength 100 100 INTENSITY 80 60 40 20 RELATIVE EFFECTIVENESS 80 60 40 20 0 100 200 300 400 500 600 WAVELENGTH (NANOMETERS) STER-L-RAY Germicidal Lamps are short-wave, low pressure mercury vapor discharge tubes that produce ultraviolet wavelengths lethal to microorganisms.*ster-l-ray High Output (HO) germicidal lamps are similar in size and shape to conventional germicidal lamps but are capable of operating at higher input power and current. Approximately 95% of the ultraviolet energy emitted from STER-L-RAY germicidal lamps is at the mercury resonance line of 254 nanometers, the region of germicidal effectiveness most destructive to bacteria, mold and virus.. STER-L-RAY and the STER-L-RAY logo are trademarks of Atlantic Ultraviolet Corporation CAUTION: Exposure to direct or reflected germicidal ultraviolet rays will cause painful eye irritation and reddening of the skin. Personnel subject to such exposure must wear suitable faceshield, gloves and protective clothing. Hg - LAMP CONTAINS MERCURY, manage in accord with disposal laws, see: www.lamprecycle.org. ULTRAVIOLET DOSAGE 0 200nm 225nm 250nm 275nm 300nm WAVELENGTH (NANOMETERS) Germicidal lamps provide effective protection against microorganisms. A small cross-section is shown below. ORGANISM ALTERNATE NAME TYPE DISEASE DOSE* Corynebacterium diphtheriae C. diphtheriae Bacteria Diptheria 6,500 Legionella pneumophila L. pneumophila Bacteria Legionnaire s Disease 2,700 Mycobacterium tuberculosis M. tuberculosis Bacteria Tuberculosis (TB) 10,000 Pseudomonas aeruginosa P. aeruginosa Bacteria 3,900 Serratia Marcescens S. marcescens Bacteria 6,160 Staphlylococcus aureus S. aureus Bacteria 6,600 Staphlylococcus epidermidis S. epidermidis Bacteria 5,800 Adeno Virus Type III Virus 4,500 Coxsackie A2 Virus 6,300 Influenza Virus Flu 3,400 * Nominal Ultraviolet dosage (µwsec/cm2) necessary to inactivate better than 99% of specific microorganism. Consult factory for more complete listing. ultraviolet.com buyultraviolet.com 11

The Standard of Excellence In Ultraviolet Manufacturers / Engineers / Sales / Service Germicidal Ultraviolet - Equipment & Lamps 375 Marcus Boulevard Hauppauge, NY 11788 631.273.0500 Fax: 631.273.0771 E-mail: info@ultraviolet.com ultraviolet.com buyultraviolet.com The information and recommendations contained in this publication are based upon data collected by the Atlantic Ultraviolet Corporation and are believed to be correct. However, no guarantee or warranty of any kind, expressed or implied, is made with respect to the information contained herein. Specifications and information are subject to change without notice. Document No. 98-1095 September 2017 2017 by Atlantic Ultraviolet Corporation MADE IN THE USA