Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

Similar documents
BCTC CARPET TECHNICAL CENTRE

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Analysis Report

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS EN ISO : 2010

Analysis Report

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS EN ISO : 2010

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Test Report: ICL/CR15/11/087

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

TFI Report Classification

BS EN ISO : 2010

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Report VNLF Test Report

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

Centrum stavebního inženýrství a.s.

Classification of Fire Performance of Wall and Ceiling Lining Materials

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

BS EN : 2001 & IEC :2000

TFI Report Reaction to fire test

Centrum stavebního inženýrství a.s.

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

New European Fire Testing Classification for Construction Products

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

IMO Resolution MSC 61(67): Annex 1: Part 2

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Test Report: ICL/H18/9039 Rev 1

Classification report

NF X : Parts 1, 2, 3, 4 & 5

CLASSIFICATION REPORT

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

TFI Report Classification

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

Fire Testing of Foams

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

Contact person Date Reference Page Richard Johansson P (2) Fire Research

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

Review Fire Test Report

Test Report No: ICL/H17/7967

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS

FAÇADE FIRE TESTS Towards a new European standard method

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

Reaction to fire classification report No C

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

Additional Reaction to Fire Classification Report

Reaction to fire classification report No C-rev.1

Certifikat och provningsprotokoll för art och 4511

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation

SUBJECT: ASSESSMENT FOR INTERNAL SURFACE FINISHES OF LIGHTBETON PANEL FOR COMPLIANCE WITH THE NEW ZEALAND BUILDING CODE(NZBC)

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

Annex of the certificate (Page 1/5) Accreditation Scope

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

FRANCE M & F RANKING ACCORDING TO NF F

CERTIFICATE OF APPROVAL No ME 5085

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

Information Data Sheet. Fire behavior of decorative high pressure laminates (HPL)

~~oeti. Report VN71 O Classification Report. Reference

Global flammability standards.

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

Abrasion Resistance of Fluoropolymer and polyester Coatings

FIRE TESTING OF LOW SLOPE ROOF ASSEMBLIES AN INTERNATIONAL REVIEW

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

Development of a European approach to assess the fire performance of facades

SIGMADEK, LTD. FIRE TEST REPORT

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Additional reaction to fire classification report No H

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

ASSESSING THE FIRE PERFORMANCE OF ELECTRIC CABLES (FIPEC)

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

Product Data Sheet Trespa HPL Panels

Loss Prevention Standard

Transcription:

Return address: P.O. box 337, 7500 AH Enschede, TNO Centre for Textile Research Ariënsplein 3 7511 JX ENSCHEDE Forbo Flooring Attn. Mr. A. Tijhof Postbus 13 1560 AA Krommenie Report Sponsor : Contractor, manufacturer : Forbo Flooring Product name :. Lot. No. : 66869/3877. Notified Body : No. 336. Description and Composition : Marmoleum Click is produced by laminating linoleum produced in accordance with EN 548 consisting of two-layer homogeneous mixture of linoleum cement, wood flour, limestone and pigments, applied on a fibrous backing, onto a HDF board with a cork sheet backing. Linoleum cement consists of a mixture of linseed oil and/or other vegetable drying oils and rosin. The construction is given by manufacturer: Nominal Thickness, mm : 9.8 Nominal thickness of the independent layers: Marmoleum, mm : 2.0 density, kg/m 2 : ± 2.4 HDF board, mm : 6.8 density, kg/m3 : ± 880.0 Cork sheet, mm : 1.0 density, kg/m3 : ± 220.0 The surface layer of the Marmoleum has a minimum thickness of 0,8 mm. P.O. Box 337 7500 AH Enschede Parking and delivery Van Galenstraat 21 7511 JL ENSCHEDE www.tno.nl T +31 53 486 04 86 F +31 53 486 04 87 Direct dialling +31 (0)75 647 7014 Direct fax +31 (0)75 647 7707 Your reference Your letter of 6-9-2006 Your order of 9-10-2006 The Standard Conditions for Research Instructions given to TNO, as filed at the Registry of the District Court and the Chamber of Commerce in The Hague shall apply to all instructions given to TNO; the Standard Conditions will be sent on request. Family of Products : Linoleum laminated on HDF board with a cork sheet backing. Purpose : Classification accordance EN 13501:2002. Reaction to fire test, according to: EN ISO 11925-2:2002 Reaction to fire tests for building products, Part 2: Ignitability when subjected to direct impingement of flame (ISO 11925-2:2002). EN ISO 9239 reaction to fire tests for floor coverings, Part 1: Determination of the burning behaviour using a radiant heat source (ISO 9239-1:2002). Tested on particle board.

Results Conclusion : On pages three up to and including six. : floor covering fulfilled the requirements of: EN ISO 11925-2, (Fs <= 150 mm within 20 s.) and EN ISO 9239-1, (critical flux ".5 kw.m 2 ). Class: C FL. Additional classification: s1. Notation: C FL - s1 2/5 Statements : The test results only relate to the behaviour of the test specimens of the examined product under the particular conditions of the test in laboratory conditions; they are not intended to be the sole criterion for assessing the potential fire hazard of the product in use. The method might not be suitable if the product is exposed to much larger flames or heat radiant sources. The validity of this report will expire five years after its issue or directly after alterations or modifications of the examined product(combination)(s) and/or the criteria. This report shall not be reproduced, except in full, without the written approval of the testing laboratory. Projectmanager: Visa: V.Kruys R. Boerboom

Test results: EN-ISO 11925-2:2002 Small burner examination of test : 21 september 2006. Conditioning time, climate : 7 days, 23 ± 2 C and 50 ± 5 % Description of substrate : 6 mm. Fibre cement board, 1800 kg/m 3. Flame application : Surface. Application time : 15 seconds. Surface ignition All test specimens are tested in one direction Total burning time 1 (15 s) 15 15 15 15 15 15 15 15 15 15 Flame tip reaches 150 mm (sec) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Extent (mm) of damaged area, length 35 35 40 35 35 35 35 40 40 35 Extent (mm) of damaged area, width 10 11 10 10 10 10 9 11 11 11 Material melts (y/n) n n n n n n n n n n Shrinks away 2 (y/n) n n n n n n n n n n Glowing 3 (sec) Flaming debris 4 (yes/no) n n n n n n n n n n Ignition of filter paper (y/n) n n n n n n n n n n Conclusion Marmoleum Click floor covering, fulfilled the requirements EN ISO 11925-2 5 (Fs <= 150 mm within of 20 s.). Assessment: Based on the test results and evaluating the criteria for classification according to clause 8 of the EN-ISO 11925-2:2002 the examined Marmoleum Click floor covering proved to be capable of resisting, for a short period, a small flame attack without substantial flame spread. If assessed according to Table 1 of the European classification standard EN 13501-1:2002 Classification standard for building product and building elements the examined product will be classified as follows: Class E. 3/5 1 Inclusive a flame application time of 15 or 30 seconds with surface or edge impingement. 2 Shrinks away from flame without being ignited. 3 The time at which it occurs and its duration. 4 The test shall be terminated if flaming debris is observed. 5 Under conditions of surface flame attack and, if appropriate to the end-use application of the product, edge flame attack.

Test results: EN ISO 9239-1:2002. Radiant Panel test. Test results are noted in the following appendices enclosed. of test : 25 september 2006. Conditioning time, climate : 7 days, 23 ± 2 C and 50 ± 5 % Description of substrate : Particle board. Sampling procedure : by contractor. Age information received; at the time of examination approx. 4 weeks. Description of cleaning used : N/A. Number of tested specimens : 3 + 1. Glued to the substrate : N/A. 4/5 Critical Radiant Flux 6, kw/m 2 6.4 Flashing 7 Transitory flaming 8 Sustained flaming 9 Smoke production; light attenuation, according to DIN 50055. Maximum light attenuation, % 36.4 Curve of the light attenuation over 30 minutes, %.min -1 119.5 Conclusion: floor covering tiles fulfilled the requirements of EN ISO 9239-1:2002, Class: C FL. Additional classification: s1. Classification criteria: Critical flux 10 " # kw.m 2. Smoke production 11, Smoke % # E Remarks: 1. Cleaning procedures to examine the durability of the fire performance shall be in accordance with the procedures specified in the product standards for floor coverings. 2. EN ISO 11925-2, (Fs <= 150 mm within 20 s.) and EN ISO 9239-1, (critical flux " 5 kw.m 2 ) Class: C FL. Additional classification: s1 is equal to the German classification DIN 4102, teil 14: B1. 3. floor covering tiles in accordance with DIN 4102: DIN 4102: B1. -1. 6 Critical heat flux at extinquishment: Incident heat flux (kw/m 2 ) at the surface of a specimen at the point where the flame ceases to advance and may subsequently go out. 7 Existence of flame on or over the surface of the specimen for periods of less then 1 s. 8 Existence of flame on or over the surface of the specimen for periods of between 1 s. and 4 s. 9 Existence of flame on or over the surface of the specimen for periods of more then 4 s. 10 Test duration 30 minutes. 11 Smoke production: s1 = Smoke -1.; s2 = not s1.

Appendix. 5/5 A tested specimen.

Return address: P.O. box 337, 7500 AH Enschede, TNO Centre for Textile Research Ariënsplein 3 7511 JX ENSCHEDE Forbo Flooring Attn. Mr. A. Tijhof Postbus 13 1560 AA Krommenie Report Sponsor : Contractor, manufacturer : Forbo Flooring Product name :. Lot. No. : 66869/3877. Notified Body : No. 336. Description and Composition : Marmoleum Click is produced by laminating linoleum produced in accordance with EN 548 consisting of two-layer homogeneous mixture of linoleum cement, wood flour, limestone and pigments, applied on a fibrous backing, onto a HDF board with a cork sheet backing. Linoleum cement consists of a mixture of linseed oil and/or other vegetable drying oils and rosin. The construction is given by manufacturer: Nominal Thickness, mm : 9.8 Nominal thickness of the independent layers: Marmoleum, mm : 2.0 density, kg/m 2 : ± 2.4 HDF board, mm : 6.8 density, kg/m3 : ± 880.0 Cork sheet, mm : 1.0 density, kg/m3 : ± 220.0 The surface layer of the Marmoleum has a minimum thickness of 0,8 mm. P.O. Box 337 7500 AH Enschede Parking and delivery Van Galenstraat 21 7511 JL ENSCHEDE www.tno.nl T +31 53 486 04 86 F +31 53 486 04 87 Direct dialling +31 (0)75 647 7014 Direct fax +31 (0)75 647 7707 Your reference Your letter of 6-9-2006 Your order of 9-10-2006 The Standard Conditions for Research Instructions given to TNO, as filed at the Registry of the District Court and the Chamber of Commerce in The Hague shall apply to all instructions given to TNO; the Standard Conditions will be sent on request. Family of Products : Linoleum laminated on HDF board with a cork sheet backing. Purpose : Classification accordance EN 13501:2002. Reaction to fire test, according to: EN ISO 11925-2:2002 Reaction to fire tests for building products, Part 2: Ignitability when subjected to direct impingement of flame (ISO 11925-2:2002). EN ISO 9239 reaction to fire tests for floor coverings, Part 1: Determination of the burning behaviour using a radiant heat source (ISO 9239-1:2002). Tested on particle board.

Results Conclusion : On pages three up to and including six. : floor covering fulfilled the requirements of: EN ISO 11925-2, (Fs <= 150 mm within 20 s.) and EN ISO 9239-1, (critical flux ".5 kw.m 2 ). Class: C FL. Additional classification: s1. Notation: C FL - s1 2/5 Statements : The test results only relate to the behaviour of the test specimens of the examined product under the particular conditions of the test in laboratory conditions; they are not intended to be the sole criterion for assessing the potential fire hazard of the product in use. The method might not be suitable if the product is exposed to much larger flames or heat radiant sources. The validity of this report will expire five years after its issue or directly after alterations or modifications of the examined product(combination)(s) and/or the criteria. This report shall not be reproduced, except in full, without the written approval of the testing laboratory. Projectmanager: Visa: V.Kruys R. Boerboom

Test results: EN-ISO 11925-2:2002 Small burner examination of test : 21 september 2006. Conditioning time, climate : 7 days, 23 ± 2 C and 50 ± 5 % Description of substrate : 6 mm. Fibre cement board, 1800 kg/m 3. Flame application : Surface. Application time : 15 seconds. Surface ignition All test specimens are tested in one direction Total burning time 1 (15 s) 15 15 15 15 15 15 15 15 15 15 Flame tip reaches 150 mm (sec) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Extent (mm) of damaged area, length 35 35 40 35 35 35 35 40 40 35 Extent (mm) of damaged area, width 10 11 10 10 10 10 9 11 11 11 Material melts (y/n) n n n n n n n n n n Shrinks away 2 (y/n) n n n n n n n n n n Glowing 3 (sec) Flaming debris 4 (yes/no) n n n n n n n n n n Ignition of filter paper (y/n) n n n n n n n n n n Conclusion Marmoleum Click floor covering, fulfilled the requirements EN ISO 11925-2 5 (Fs <= 150 mm within of 20 s.). Assessment: Based on the test results and evaluating the criteria for classification according to clause 8 of the EN-ISO 11925-2:2002 the examined Marmoleum Click floor covering proved to be capable of resisting, for a short period, a small flame attack without substantial flame spread. If assessed according to Table 1 of the European classification standard EN 13501-1:2002 Classification standard for building product and building elements the examined product will be classified as follows: Class E. 3/5 1 Inclusive a flame application time of 15 or 30 seconds with surface or edge impingement. 2 Shrinks away from flame without being ignited. 3 The time at which it occurs and its duration. 4 The test shall be terminated if flaming debris is observed. 5 Under conditions of surface flame attack and, if appropriate to the end-use application of the product, edge flame attack.

Test results: EN ISO 9239-1:2002. Radiant Panel test. Test results are noted in the following appendices enclosed. of test : 25 september 2006. Conditioning time, climate : 7 days, 23 ± 2 C and 50 ± 5 % Description of substrate : Particle board. Sampling procedure : by contractor. Age information received; at the time of examination approx. 4 weeks. Description of cleaning used : N/A. Number of tested specimens : 3 + 1. Glued to the substrate : N/A. 4/5 Critical Radiant Flux 6, kw/m 2 6.4 Flashing 7 Transitory flaming 8 Sustained flaming 9 Smoke production; light attenuation, according to DIN 50055. Maximum light attenuation, % 36.4 Curve of the light attenuation over 30 minutes, %.min -1 119.5 Conclusion: floor covering tiles fulfilled the requirements of EN ISO 9239-1:2002, Class: C FL. Additional classification: s1. Classification criteria: Critical flux 10 " # kw.m 2. Smoke production 11, Smoke % # E Remarks: 1. Cleaning procedures to examine the durability of the fire performance shall be in accordance with the procedures specified in the product standards for floor coverings. 2. EN ISO 11925-2, (Fs <= 150 mm within 20 s.) and EN ISO 9239-1, (critical flux " 5 kw.m 2 ) Class: C FL. Additional classification: s1 is equal to the German classification DIN 4102, teil 14: B1. 3. floor covering tiles in accordance with DIN 4102: DIN 4102: B1. -1. 6 Critical heat flux at extinquishment: Incident heat flux (kw/m 2 ) at the surface of a specimen at the point where the flame ceases to advance and may subsequently go out. 7 Existence of flame on or over the surface of the specimen for periods of less then 1 s. 8 Existence of flame on or over the surface of the specimen for periods of between 1 s. and 4 s. 9 Existence of flame on or over the surface of the specimen for periods of more then 4 s. 10 Test duration 30 minutes. 11 Smoke production: s1 = Smoke -1.; s2 = not s1.

Appendix. 5/5 A tested specimen.