EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Similar documents
ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Evaluation for Replacement of R22 as R161 in the Vapour Compression Cycle through Aspen Plus Software

ADVANCES in NATURAL and APPLIED SCIENCES

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

A Comparison Between Refrigerants Used In Air Conditioning

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

A Review on selecting an Eco-friendly Refrigerant alternate to R134a in Domestic Refrigerators

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

CHAPTER 1 INTRODUCTION

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Study of R161 Refrigerant for Residential Airconditioning

CHAPTER 1 INTRODUCTION

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

EXPERIMENTAL INVESTIGATION OF A REFRIGERATOR BY USING ALTERNATIVE ECO FRIENDLY REFRIGERANTS (R600A & HC MIXTURE)

International Journal of Advance Engineering and Research Development

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

JJMIE Jordan Journal of Mechanical and Industrial Engineering

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Journal Impact Factor: 2.114

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

SIMULATION OF POTENTIAL REFRIGERANTS FOR RETROFIT REPLACEMENT

Oyelami S., Bolaji B. O.

Performance and exergy analysis of vapour compression refrigeration system using various alternative of R134a.

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Experimental study of R600a and R436a to replace R134a in a domestic refrigerator and freezer

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

η second law = Second law efficiency

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Theoretical study on a modified subcooling vaporcompression refrigeration cycle using hydrocarbon mixture R290/R600a

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

THEORETICAL INVESTIGATION OF THE PERFORMANCE OF SOME ENVIRONMENT-FRIENDLY REFRIGERANTS IN A SUB-COOLING HEAT EXCHANGER REFRIGERATION SYSTEM

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

DEEPAK PALIWAL, S.P.S.RAJPUT

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Experimental investigation on the performance of air conditioner using R32 Refrigerant

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

Department of MCE, Islamic University of Technology 2. Abstract

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Evaluation of HCFC Alternative Refrigerants

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

Performance Evaluation of Vapour Compression System with R22 and Environment-Friendly Refrigerant

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Refrigerants Retrofit as Alternative for R12 and R134a in Household Refrigerators

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

Sarthak Thakar, 2 R.P.Prajapati 1

Chapter 10. Refrigeration and Heat Pump Systems

A RECENT REVIEW OF REFRIGERANT R-1234YF AND R-1234ZE (E)

R134a Refrigerant in Vapour Compression Cycle: A Review Paper

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Design and Fabrication of Liquefied Petroleum Gas Refrigeration System and Comparison with Domestic Refrigerator

Design of LPG Refrigeration System

Chapter 2. Alternatives to HCFCs and their Characteristics

Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C

TYPICAL INITIAL OUTPUT OF A CO 2 HEAT PUMP

Volume 2, Issue 1 (2014) ISSN International Journal of Advance Research and Innovation

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

Energy Performance of Eco-friendly R152a and R600a Refrigerants as Alternative to R134a in Vapour Compression Refrigeration System

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Thermodynamics I. Refrigeration and Heat Pump Cycles

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

STUDY AND PERFORMANCE ANALYSIS OF ECO-FRIENDLY REFRIGERANT FOR RETROFITTING R22 IN RESPECT TO BANGLADESH

Theoretical analysis of low GWP mixture R600a/ R1234ze as a possible alternative to R600a in domestic refrigerators

EXPERIMENTAL STUDY ON R1234YF HEAT PUMP AT LOW AMBIENT TEMPERATURE AND COMPARISON WITH OTHER REFRIGERANTS

Transcription:

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22 Ameya P. Shrivastava 1, Choudhari Chandrakishor S. 2 1,2 Mechanical Department, AISSMS College of Engineering, Pune 411001, (India) ABSTRACT HCFC s are to be phased out in the near future according to some International treaties, like Montreal protocol and Kyoto agreement, due to their negative impact on earth s environment. HCFC-22 is the most widely used refrigerant in air conditioning and commercial appliances and causes ozone depletion, hence need to phase out earlier. This paper discusses the theoretical aspects of HC-290 (propane) as a potential substitute for HCFC- 22. Earlier, HC-290 was neglected with contention that flammable fluids are not safe to be used as refrigerants. But, with the technological development, refrigeration industry has started working on flammable refrigerants and hence propane can be effectively employed. Theoretical analysis shows that the thermo physical properties and environmental properties of HC-290 is much better than HCFC-22 hence making it feasible for replacement. Keywords: Alternative refrigerants, HC290, HCFC22, Refrigeration. I. INTRODUCTION With increasing recognition of environment protection, a great deal of attention has been devoted to the negative environmental effect of CFCs and HCFCs refrigerant. Based on scientific findings, regulatory requirements and market pressure, the governing selection criteria for the new alternative refrigerants are changing. New long term alternative refrigerant should have not only zero ODP but it should have low GWP value initially 150 or less with old requirements of suitability, safety, and material compatibility. At the same time it should have short (but not too short) atmospheric life. Most important, new alternative must offer high efficiency to reduce indirect contribution to the greenhouse effect.in refrigeration and air-conditioning industries, HCFC22 is the most widely used refrigerant. Complying with the Montreal Protocol, R22 must be phased out in developed and developing countries as early as possible. The problems of the depletion of ozone layer and increase in global warming caused scientists to investigate more environmentally friendly refrigerants than HFC refrigerants for the protection of the environment such as hydrocarbon (HC) refrigerants of propane, isobutene, n-butane, or hydrocarbon mixtures as working fluids in refrigeration and air conditioning systems. Accordingly, few environment friendly refrigerants has been recommended by most researchers and refrigerant manufacturers and applied in actual equipment to replace R22. From the recommended refrigerant alternatives, propane is most effective and compatible refrigerant. Propane (R290) is an eco-friendly hydrocarbon refrigerant which has very low Global Warming Potential (GWP) and zero Ozone Depletion Potential (ODP) also it has no direct impact on the greenhouse effect. It has excellent thermal performance, low price, and is compatible with general 739 P a g e

machinery lubricants and structural material. It has excellent thermodynamic properties leading to high energy efficiency and low charges allow smaller heat exchangers and piping dimensions. II. EVALUATION OF REFRIGERANTS R22 and R290 2.1 Thermo Physical Properties Molecular weight of HC-290 is lower than molecular weight of R22 by 49%. Latent heat of evaporation of HC- 290 is 82% higher than R22 at normal boiling point. This indicates that per KW of cooling capacity, charge required of HC-290 is less by about 55% than that of R22. Also due to higher heat capacity, discharge temperature of HC-290 will be lower compared to HCFC-22. Normal boiling point of HC-290 is slightly higher than that of HCFC-22. Saturated pressure of HC-290 is slightly lower than that of HCFC-22. Lower saturation pressure of refrigerant allows ease in manufacturing of refrigeration system that too at low cost. The critical temperature of a refrigerant decides the performance of a refrigerant under high ambient conditions. Performance of refrigerants with lower critical temperature decreases fast with increase in ambient temperature than the refrigerants having higher critical temperature. This factor is of more importance in countries like India. Critical temperature of HC-290 is slightly higher than that of HCFC-22. Table 1: Thermo physical properties of R22 and R290. Refrigerant R22 R290 Molecular Weight 86.47 44.10 Normal B.P. 0 C ~40.75 ~42.2 Critical Temp. Tc 0 C 96.2 96.7 Critical Press MPa 4.99 4.25 Latent heat of Evap kj/kg 233.7 425.4 2.2 Environmental characteristics Atmospheric life of R-290 is very less, i.e. almost 99% as that of R-22 which means it will sustain in environment for very less time and hence it is environment friendly. HC-290 is a non-ozone depleting refrigerant whereas R22 is a non-zero ODP refrigerant. GWP value of HC-290 is 20, which is very low value compared to R22. Table 2: Environmental characteristics of R22 and R290. Refrigerant R22 R290 Atm. life (Years) 11.9 0.041 ODP(R11=1) 0.055 0.000 GWP 100yr(CO2=1) 1700 20 740 P a g e

2.3 Safety characteristics For the development of HC-290, flammability and toxicity are very important parameters due which it was neglected alternative for so many years. R290 is classified under A3 safety class as per ASHRE34-2010 due to this it has been avoided. But it has good thermo physical properties which is similar to R22, hence can be effectively used with taking proper care of leakage factor during operation. The European standard EN378 gives the safety requirements for the use of flammable refrigerants in various applications. As per the EN378 and ASHRAE15, the charge limit is about 8g/m 3 for R290. Toxicity safe index for HCFC22 and R290 are similar. Table 3: Safety characteristics of R22 and R290. Refrigerant R22 R290 LFL by mass kg/m 3-0.075 LFL by volume % - 2.1 Burning velocity cm/s - 46 Combustion heat MJ/kg - 50.3 Toxicity ppm 1000 1000 Safety class A1 A3 2.4 Evaluation of refrigerants R22 and R290 R290 is environment friendly and it has many similar properties compared to R22 except flammability. As compared to R22, propane has higher refrigeration effect and power output along with lower discharge temperature. It has zero ODP and GWP of about 20. Hence, R290 (propane) can be a better alternative as a replacement to R22. III. PROPERTY COMPARISON BETWEEN R290 AND R22 Various physical and chemical properties of Propane (R290) and R22 are compared graphically, in which, variation in evaporating temperature is considered over a range of -35 o C to 70 o C. All the basic thermo physical properties of both the refrigerant are obtained from REFROF software. These properties were systematically evaluated in both liquid and vapour state and then formulated in an excel sheet. Based on this, the various property comparison graphs are shown below- 741 P a g e

3.1. Variation in specific heat (Cp) with temperature: Figure 1: Temperature vs Liquid Cp. Figure 2: Temperature vs Vapour Cp. 3.2. Variation in Thermal Conductivity with Temperature Figure 3: Temp. vs Liquid Thermal conductivity. conductivity. Figure 4: Temp. vs Vapour Thermal 742 P a g e

3.3. Variation in Viscosity with Temperature: Figure 5: Temperature vs Liquid Viscosity. Figure 6: Temperature vs Vapour Viscosity. 3.4. Variation in Density with Temperature Figure 7: Temperature vs Liquid Density. Figure 8: Temperature vs Vapour Density. 3.5. Variation in Pressure with Temperature Figure 9: Temperature vs Saturation Pressure 743 P a g e

IV.THEORETICAL INVESTIGATION OF PERFORMANCE OF VAPOUR COMPRESSION CYCLE WITH HC290 AND HCFC22 In this study, a theoretical investigation of the performance of the vapour compression cycle with refrigerant HC290 and HCFC22 is carried out. For performance analysis of these two refrigerants, an ideal vapour compression refrigeration system is used. Performance parameters such as Pressure ratio (PR),discharge temperature, refrigerating effect (RE), compressor work, Coefficient of performance (COP), volumetric refrigeration capacity (VRC) and power (P) are investigated for various evaporating temperatures ranging between -30 0 C to 15 0 C and constant condensation temperature of 45 0 C. For cycle performance determination some assumptions are made as ideal vapour compression cycle is considered. Some of the important assumptions are: 10 o C superheating and 5 o C sub cooling, negligible pressure drops and heat losses to the surrounding, expansion is isenthalpic and compression is isentropic. Following equations are used for cycle analyse. Pressure ratio = (1) Compressor work done (kj/kg) = (2) Refrigerating effect (kj/kg) = (3) Volumetric refrigeration Capacity (VRC) = ρ i.re (4) COP = RE/P (5) Using these above equations, all the performance parameters of a standard vapour compression cycle were calculated and results are represented in the following graphs- Figure 10: Pressure ratio Vs Temperature Figure 11: Discharge Temp. Vs Temperature 744 P a g e

Figure 12: Refrigerating effect Vs Temperature Figure 13: Compressor work Vs Temperature Figure 14: COP Vs Temperature Figure 15: VRC Vs Temperature V. RESULTS AND DISCUSSIONS Cycle performance of a refrigeration system, to a large extent, depends on thermo physical properties of a refrigerant. In this paper, thermo physical properties and theoretical performance of HFC290 is compared with HCFC22, which is to be phased out in coming years. In property comparison, figure 1 and 2 show that liquid and vapour specific heat of R290 is almost 53% and 67% higher than that of R22 respectively. From figure 3 and 4, it can be observed that liquid and vapour thermal conductivity is 10.5% and 40% higher whereas, figure 5 and 6 shows that liquid and vapour viscosity are 42% and 34.5% lower for R290 than that of R22 respectively. Figure 7 and 8 shows that liquid and vapour density is 58.5% and 50.5% lower whereas figure 9 shows that saturation pressure is 3.5% lower for R290 than that of refrigerant R22 respectively. In theoretical study, pressure ratio, discharge temperature, refrigerating effect (RE), isentropic compression work, coefficient of performance (COP), volumetric refrigeration capacity (VRC) and power per ton are investigated and plotted against varying temperature as shown in figure 6 to 12 for ideal refrigeration cycle. Temperature range is 745 P a g e

considered from -30 C to 15 C and condensation temperature at 55 C. Figure 10 shows that pressure ratio decreases with increase in operating temperature. For R290, pressure ratio is slightly higher compared to R22. The difference in pressure ratio decreases from 13.3% to 4.2% with increase in evaporator temperature in the given range. Figure 11 shows that discharge temperature of a refrigerant decreases with increase in evaporating temperature. Discharge temperature for R290 is lower than that of R22 by 11% to 3.4%. Figure 12 and figure 13 shows that refrigerating effect and compressor work for R290 is 41.5% and 51.5% higher than that of R22 at evaporating temperature of -5 o C. Figure 14 show that COP for R290 is higher than that of R22 by 18.6% to 14% in the varying temperature range with increase in temperature. From figure 15 it can be seen that, volumetric refrigerating capacity increases with temperature. It is lower for R290 compared to R22. VI. CONCLUSION Evaluation of thermo physical properties showed that R290 is far better than R22, i.e. it has high specific heat and thermal conductivity & low viscosity and density values. Theoretical cycle performance of both the refrigerants for the varying temperature range of -30 C to 15 C shows that R290 is a promising alternative refrigerant to R22. Refrigerating effect is higher and discharge temperature is lower for R290 compared to R22. Though, COP value for R290 is slightly lower, but it can be improved by specially designing a refrigeration system for it. Hence, it can be concluded that refrigerant R290 is an excellent replacement for refrigerant R22 for medium temperature REFERENCES [1] Khalid A. Joudi, Qusay R. Al-Amir, Experimental Assessment of residential split type air-conditioning systems using alternative refrigerants to R-22 at high ambient temperatures, Energy Conversion and Management 86 (2014) 496 506. [2] B.O. Bolaji, Z.Huan, Ozone depletion and global warming: Case for the use of natural refrigerant a review, Renewable and Sustainable Energy Reviews 18 (2013) 49 54. [3] Tingxun Li, Indoor leakage test for safety of R-290 split type room air conditioner, International Journal of Refrigeration 40 (2014) 380-389. [4] M. Mohanraj, S. Jayaraj, C. Muraleedharan, Environment friendly alternatives to halogenated refrigerants A review, International Journal of Greenhouse Gas Control 3 (2009) 108-119. [5] A.S. Dalkilic, S. Wongwises, A performance comparison of vapour-compression refrigeration system using various alternative refrigerants, International Communications in Heat and Mass Transfer 37 (2010) 1340 1349. [6] E. Halimic, D. Ross, B. Agnew, A. Anderson, I. Potts, A comparison of the operating performance of alternative refrigerants, Applied Thermal Engineering 23 (2003) 1441 1451. [7] Adri_an Mota-Babiloni, Joaquı n Navarro-Esbrı, Angel Barrag_an-Cervera, Francisco Mol_es, Bernardo Peris, Gumersindo Verdu, Commercial refrigeration - An overview of current status, International Journal of Refrigeration 57 (2-15) 186-196. 746 P a g e

[8] Eric Granryd, Hydrocarbons as refrigerants - an overview, International Journal of Refrigeration 24 (2001) 15-24. [9] B. Saleh, M. Wendland, Screening of pure fluids as alternative refrigerants, International Journal of Refrigeration 29 (2006) 260 269. [10] Mao-Gang He, Xin-Zhou Song, Huan Liu, Ying Zhang, Application of natural refrigerant propane and propane/isobutene in large capacity chest freezer, Applied Thermal Engineering 70 (2014) 732e736. 747 P a g e