SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

Similar documents
A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

Digital Precise Air Control - DPAC

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

Job Name Control Systems Description Date

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

HVAC Controls Upgrades: Requirement Details ( )

Metasys Integrator TITUS Application

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

terminal unit accessories

ADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT. February 29, NO CHANGE: March 8, 2012 / NOT LATER THAN 2:00 PM

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

Selected Laboratory Energy Efficiency Measures

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

I/O ZONE 560/583 USERS GUIDE

Your Home. Jacco & Assoc.

BACnet PTEC Controller VAV 0 to 10V Series Fan and 3- Stage Electric Heat, Application 6657

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

To: Steve Ardolf, MSU Mankato From: Chris Plum, CEE. CC: Tim Ellingson, CEE. Angela Vreeland, CEE Dan Briese, MSU Mankato Date: April 21, 2014.

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP 100% OUTSIDE AIR

Verasys System Operation Overview Technical Bulletin

AIR HANDLING SYSTEM RETRO-COMMISSIONING TRENDING ANALYSIS

Your Home. Jacco & Assoc. Fan on with call for heating or cooling Heating on with call from space thermostat Stage as

American University Design Standards

HVAC Controls Upgrades: Requirement Details ( )

Control Sequence Number

DIGI-VAV APPLICATIONS

ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C

CONTENTS. Installation Guide. VT7200 Series

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

OSU Alumni Center Phase I Implementation Review. Oregon State University 130 Oak Creek Bldg. Corvallis, Oregon

Spartan Peripheral Devices. TE 256S Thermostat Applications

BACnet Points for Single Compressor Water-to- Air Heat Pumps With Hot Gas Reheat Utilizing the FX10 Controller

SECTION SEQUENCE OF OPERATIONS FOR BUILDING CONTROLS

ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

I N STALL AT ION & O PERATIO N MANUAL TA 1/ TA 2 CONTROLLER. Redefine your comfort zone.

AdaptAire. Digital Control System. User Manual

Reference Guide for Microprocessor Controller

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

McQuay Microtech III BACnet MS/TP Application 4181 Point Map

SE7200 Series Installation Guide

Reference Guide for Microprocessor Controller

Document # R01

Single zone RTU, controlled by a programmable thermostat. Single zone RTU, generic description, with power exhauster

MicroTech Self-Contained Air Conditioning System

Florida Department of Transportation

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

AireLogic. Digital Control System. User Manual

Modeling projects that require very tight space temperature control

Reference Guide for Microprocessor Controller

Building Automation System (BAS) Design Criteria

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

MicroTech Rooftop/RMC

10+ HVAC Troubleshooting Tips for Healthcare Facilities Jerry Hirsch JCI Facility O&M Performance Development Manager.

INSTALLATION AND OPERATION MANUAL ANALOG ELECTRONIC CONTROLS VAV TERMINAL UNITS

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER

Case Study: Furman University Charles H. Townes Center for Science. Michael K. Mantai, PE, CCP President System WorCx

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone:

TEC Controller Unit Conditioner - Two-Pipe Fan Coil Cooling or Heating, Application Application Note Building Technologies

1.0 Digital Controller

Dehumidifying with Dedicated Outdoor Air

York 25-Ton VAV Rooftop Unit

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

T7984 A,B,C Electronic Modulating Control Thermostats

IAQ: Re-tuning Commercial Buildings

Application and Instructions for Field Adjustment of the Control (Model FX06) in Digital Control Option D12A, Space Control with Discharge Air Reset

TEC Controller Multiple Compressor Heat Pump with Reversing Valve & Mixed Air Control, Application Application Note

DX-9100 Applications from Engineering Services

BACnet MODBUS N2 LON Description Type Point Description Name # Object Type Register Type ID SNVT # Name SNVT Read Only

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.80

Submitted to. Texas A&M University at Galveston The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B

Prescriptions for Critical Healthcare Cx. John D. Villani, P.E. Associate Grumman/Butkus Associates

TEC Controller Heating & Cooling Heat Pump with Internal Reversing Valve & Mixed Air Control, Application 2072

Zoned Rooftop Systems. Light commercial packaged rooftop systems from Trane

2006 Washington State Nonresidential Energy Code Compliance Form Washington State Nonresidential Energy Code Compliance Forms Revised July 2007

- Data Brochure Universal Reset Module 422

TEC Controller Single Compressor Heat Pump with Reversing Valve Control, Application Application Note Building Technologies

UNT Applications. Using UNT Applications...3. Introduction Key Concepts UNT Controller Applications Fan Coil Units...

Ramp It Up VAV Ramps and Controller Possiblities

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE COOLING-ONLY 100% OUTSIDE AIR VERSION Telephone:

AirTrak. Digital Control System. User Manual. Touchscreen Systems

TC-9102 Applications

CONTROL OPTIONS SPACE HEATING APPLICATIONS MAKEUP AIR HEATING APPLICATIONS PEH, PXH, RDH, REH, RXH, SDH & SHH. Horizontal Split System- Models PDH,

- Data Brochure Universal Reset Module 423

FORM EG2 (502) FlexSys Configured Packaged Rooftop Air Conditioning Units

AdaptAire. Digital Control System. User Manual. Expert Systems

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

COMcheck Software Version Mechanical Compliance Certificate

BAS Point Trend Data Guidance

BES-TECH TECHNOLOGY & SYSTEM INTEGRATION

Transcription:

SEQUENCE OF OPERATION GUIDELINE AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT Document: VAV-HTG rev1 Revision: 1.0 Rev. Date: July 22, 2011 NOTES: 1. THIS SEQUENCE IS INTENDED TO PROVIDE THE DESIGN PROFESSIONAL WITH A BASIC GUIDELINE OF MINIMUM REQUIREMENTS FOR TYPICAL VAV AIR TERMINAL UNITS. THIS SEQUENCE SHALL BE CAREFULLY REVIEWED AND EDITED WITH RESPECT TO APPLICATION-SPECIFIC PROJECT REQUIREMENTS AND PROPOSED MODIFICATIONS SHALL BE REVIEWED WITH FSU STAFF. 2. THE INTENT IS FOR THIS SEQUENCE TO BE INCLUDED IN THE CONTRACT DRAWINGS. 3. USE ZONE OCCUPANCY SENSORS FOR UNOCCUPIED MODE WHENEVER POSSIBLE. COORDINATE WITH ELECTRICAL/LIGHTING DESIGN FOR DUAL USE. 4. REFERENCE STANDARD CONTROL DIAGRAMS IC-16. VAV BOXES WITH HOT WATER REHEAT: PROVIDE THE FOLLOWING FOR ALL AIR TERMINAL UNIT BOXES. 1. ROOM THERMOSTAT WITH INTEGRAL TEMPERATURE SENSOR, INTEGRAL DISPLAY, SLIDING SCALE SETPOINT ADJUSTMENT, AND REMOTE COMMUNICATION PORT. 2. PRESSURE INDEPENDENT VOLUME CONTROL WITH ADJUSTABLE MAXIMUM AND MINIMUM AIRFLOW SETTINGS. 3. CLOSE HOT WATER REHEAT AND RETURN THE VOLUME DAMPER TO A MINIMUM POSITION (25 %) WHEN ASSOCIATED AHU IS OFF. 4. PROVIDE A SUPPLY AIR SENSOR DOWNSTREAM OF THE HEATING COIL FOR USE IN MONITORING OVERALL VAV BOX PERFORMANCE. 5. OCCUPIED MODE SHALL BE DETERMINED BY [SCHEDULE OR LOCAL OCCUPANCY SENSOR]. OCCUPIED MODE 1. THE CONTROLLER SHALL CONTINUE TO MONITOR ROOM TEMPERATURE AND RESET THE CFM SETPOINT UP OR DOWN IN RESPONSE TO COOLING/HEATING DEMAND 2. ON A RISE IN ROOM TEMPERATURE, MODULATE THE AIR DAMPER TOWARDS ITS MAXIMUM CFM SETPOINT UNTIL OCCUPIED CLG SETPOINT HAS BEEN 1

3. WHEN THE ZONE TEMPERATURE IS BETWEEN THE COOLING SETPOINT AND THE HEATING SETPOINT, THE ZONE DAMPER SHALL CONTROL TO ITS MINIMUM OCCUPIED AIRFLOW (ADJ.). HOT WATER REHEAT REMAINS CLOSED. 4. ON A CONTINUED FALL IN ROOM TEMPERATURE, CONTINUE DELIVERING THE SCHEDULED MINIMUM AIR FLOW AND, INCREASE THE HOT WATER REHEAT OUTPUT PROPORTIONALLY UNTIL THE OCCUPIED HTG SETPOINT HAS BEEN UNOCCUPIED MODE (BASED ON SCHEDULE OR LOCAL OCCUPANCY SENSOR) ASSOCIATED AHU IS SCHEDULED OFF 1. THE AIR DAMPER SHALL REMAIN AT ITS MINIMUM 25% POSITION AND THE ELECTRIC HEAT SHALL REMAIN OFF. 2. IN THE EVENT THE AHU IS ENABLED DURING UNOCCUPIED HOURS (DUE TO A NIGHT SETBACK CALL FOR COOLING OR HEATING), THE BOX SHALL CONTROL ACCORDING TO THE OCCUPIED MODE DESCRIBED ABOVE USING THE OCCUPIED SETPOINTS. 3. THE BAS SHALL POLL THE VARIOUS ZONES AND, BASED ON A PRESET REQUEST QUANTITY TARGET (INITIALLY SET AT 2), ACTIVATE THE AHU WHEN THE ASSOCIATED QUANTITY TARGET HAS BEEN REACHED. 4. UPON ACTIVATION OF THE AHU BASED ON OCCUPANCY SENSORS, THE ASSOCIATED AHU SHALL BE TEMPORARILY ACTIVATED AND THE TERMINAL UNIT SHALL RESUME NORMAL OCCUPANCY MODE CONTROL. DEACTIVATION OF ALL LOCAL OCCUPANCY SENSORS SHALL RETURN THE TERMINAL UNIT TO ITS UNOCCUPIED STATE AND CAUSE THE ASSOCIATED AHU TO SHUT DOWN. 5. TERMINAL UNIT AND ASSOCIATED AHU SHALL REMAIN OCCUPIED AND ACTIVE FOR A MINIMUM OF 1 HR (ADJUSTABLE). ASSOCIATED AHU RUNS CONTINUOUSLY. 1. ON A RISE IN ROOM TEMPERATURE, MODULATE THE AIR DAMPER TOWARD ITS MAXIMUM CFM SETPOINT UNTIL THE UNOCCUPIED CLG SETPOINT HAS BEEN 2. ON A FALL IN ROOM TEMPERATURE MODULATE THE AIR TOWARDS ITS UNOCCUPIED MINIMUM CFM SETPOINT. ON A CONTINUED FALL IN ROOM TEMPERATURE, INCREASE THE HOT WATER REHEAT OUTPUT PROPORTIONALLY UNTIL THE UNOCCUPIED HTG SETPOINT HAS BEEN OCCUPIED CLG SETPOINT 74 F (ADJUSTABLE) OCCUPIED HTG SETPOINT 70 F (ADJUSTABLE) UNOCCUPIED CLG SETPOINT 78 F (ADJUSTABLE) UNOCCUPIED HTG SETPOINT 68 F (ADJUSTABLE) VAV BOXES WITH ELECTRIC REHEAT: PROVIDE THE FOLLOWING FOR ALL AIR TERMINAL UNIT BOXES. 1. ROOM THERMOSTAT WITH INTEGRAL TEMPERATURE SENSOR, INTEGRAL DISPLAY, SLIDING SCALE SETPOINT ADJUSTMENT, AND REMOTE COMMUNICATION PORT. 2

2. PRESSURE INDEPENDENT VOLUME CONTROL WITH ADJUSTABLE MAXIMUM AND MINIMUM AIRFLOW SETTINGS. 3. PROVIDE SCR VARIABLE CONTROL OF ELECTRIC HEAT STRIP. 4. DISABLE ELECTRIC HEAT AND RETURN THE VOLUME DAMPER TO A MINIMUM POSITION (25 %) WHEN ASSOCIATED AHU IS OFF. 5. PROVIDE A SUPPLY AIR SENSOR DOWNSTREAM OF THE HEATING COIL FOR USE IN MONITORING OVERALL VAV BOX PERFORMANCE. 6. OCCUPIED MODE SHALL BE DETERMINED BY [SCHEDULE OR LOCAL OCCUPANCY SENSOR]. OCCUPIED MODE 1. THE CONTROLLER SHALL CONTINUE TO MONITOR ROOM TEMPERATURE AND RESET THE CFM SETPOINT UP OR DOWN IN RESPONSE TO COOLING/HEATING DEMAND 2. ON A RISE IN ROOM TEMPERATURE, MODULATE THE AIR DAMPER TOWARDS ITS MAXIMUM CFM SETPOINT UNTIL OCCUPIED CLG SETPOINT HAS BEEN 3. WHEN THE ZONE TEMPERATURE IS BETWEEN THE COOLING SETPOINT AND THE HEATING SETPOINT, THE ZONE DAMPER SHALL CONTROL TO ITS MINIMUM OCCUPIED AIRFLOW (ADJ.). ELECTRIC HEAT IS DISABLED. 4. ON A CONTINUED FALL IN ROOM TEMPERATURE, CONTINUE DELIVERING THE SCHEDULED MINIMUM AIR FLOW AND, INCREASE THE ELECTRIC HEATER OUTPUT PROPORTIONALLY UNTIL THE OCCUPIED HTG SETPOINT HAS BEEN UNOCCUPIED MODE (BASED ON SCHEDULE OR LOCAL OCCUPANCY SENSOR) ASSOCIATED AHU IS SCHEDULED OFF 1. THE AIR DAMPER SHALL REMAIN AT ITS MINIMUM 25% POSITION AND THE ELECTRIC HEAT SHALL REMAIN OFF. 2. IN THE EVENT THE AHU IS ENABLED DURING UNOCCUPIED HOURS (DUE TO A NIGHT SETBACK CALL FOR COOLING OR HEATING), THE BOX SHALL CONTROL ACCORDING TO THE OCCUPIED MODE DESCRIBED ABOVE USING THE OCCUPIED SETPOINTS. 3. THE BAS SHALL POLL THE VARIOUS ZONES AND, BASED ON A PRESET REQUEST QUANTITY TARGET (INITIALLY SET AT 2), ACTIVATE THE AHU WHEN THE ASSOCIATED QUANTITY TARGET HAS BEEN REACHED. 4. UPON ACTIVATION OF THE AHU BASED ON OCCUPANCY SENSORS, THE ASSOCIATED AHU SHALL BE TEMPORARILY ACTIVATED AND THE TERMINAL UNIT SHALL RESUME NORMAL OCCUPANCY MODE CONTROL. DEACTIVATION OF ALL LOCAL OCCUPANCY SENSORS SHALL RETURN THE TERMINAL UNIT TO ITS UNOCCUPIED STATE AND CAUSE THE ASSOCIATED AHU TO SHUT DOWN. 5. TERMINAL UNIT AND ASSOCIATED AHU SHALL REMAIN OCCUPIED AND ACTIVE FOR A MINIMUM OF 1 HR (ADJUSTABLE). ASSOCIATED AHU RUNS CONTINUOUSLY. 1. ON A RISE IN ROOM TEMPERATURE, MODULATE THE AIR DAMPER TOWARD ITS MAXIMUM CFM SETPOINT UNTIL THE UNOCCUPIED CLG SETPOINT HAS BEEN 3

2. ON A FALL IN ROOM TEMPERATURE MODULATE THE AIR TOWARDS ITS UNOCCUPIED MINIMUM CFM SETPOINT. ON A CONTINUED FALL IN ROOM TEMPERATURE, ENERGIZE THE ELECTRIC HEATER IN STAGES UNTIL THE UNOCCUPIED HTG SETPOINT HAS BEEN OCCUPIED CLG SETPOINT 74 F (ADJUSTABLE) OCCUPIED HTG SETPOINT 70 F (ADJUSTABLE) UNOCCUPIED CLG SETPOINT 78 F (ADJUSTABLE) UNOCCUPIED HTG SETPOINT 68 F (ADJUSTABLE) 4

VAV # POINT TYPE ALARM TYPE: IC-16 CONDITION SHORT NAME POINT DESCRIPTION UNITS EQUIP HIGH LOW ANALOG DIGITAL ALARM LIMIT LIMIT bbb_rmxxxx_ahxxx_boxxx_flw SUPPLY AIR FLOW CFM X X X bbb_rmxxxx_ahxxx_boxxx_dmp SUPPLY AIR DAMPER %OPEN X bbb_rmxxxx_ahxxx_boxxx_rhv REHEAT VALVE OUTPUT %OPEN X bbb_rmxxxx_ahxxx_boxxx_sa SUPPLY AIR TEMPERATURE DEG F X X X bbb_rmxxxx_ahxxx_boxxx_os OCCUPANCY STATUS OCC/UNOCC X bbb_rmxxxx_ahxxx_boxxx_zt ZONE TEMPERATURE DEG F X X X bbb_rmxxxx_ahxxx_boxxx_sp ZONE TEMPERATURE SETPOINT DEG F X bbb_rmxxxx_ahxxx_boxxx_or TEMPORARY OCCUPANCY OVERRIDE OCC/UNOCC X INTEGRATED POINT NOTES 5