PIR Cover. Install Guide for PIR Cover for SE7000 Room Controller

Similar documents
SER7300 Series Installation Guide for HVAC FCU Applications

SE7200 Series Installation Guide

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers

PIR Application Guide for the for VT76xxX5x00(X) Series thermostats (Issue Date: November, 2015)

SE7600W Series. Install Guide for Water Source Heat Pump CONTENTS

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide

Fan Coil Unit (FCU) Application Guide

Product Comparison Guide

VT8300 Series Installation Guide 24 Vac Low Voltage

CONTENTS. Installation Guide. VT7200 Series

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

Sensors and Detectors

Ceiling PIR HS presence detector. Product Guide. Overview. Features

VT8600 Series Installation Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller

Honeywell ENERGY SAVINGS KIT

Product Comparison Guide. EnOcean 868MHz wireless devices for SmartStruxure TM solution and SmartStruxure Lite solution

PTAC WIRELESS KITS (DT01*, DS01*, DD01*) INSTALLATION INSTRUCTIONS

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

Omnistat3 Hospitality Energy Management Thermostat

E529 Smart Digital Thermostat Product Guide

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

Duct and Rough Service Carbon Monoxide Sensor

Schneider Electric Guestroom Management Solutions

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

Installation Guide. Ceiling PIR Detector (311) Features and Connections

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Infrared Ceiling Mount Sensor

TC300 Series Digital Fan Coil Thermostat

Infrared Wall Mount Occupancy Sensor

PIR Occupancy & Motion Sensor

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

EBDSPIR-PRM-LV Product Guide

L O D G I N G S Y S T E M S

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

Increased safety and reducing energy consumption with the motion control RPI 01

Installation Instructions

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Document # R01

MSA Flame & Gas Mapping

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

Pyroelectric Infrared Radial Sensor

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

Bryant Evolution Connex Control (SYSTXBBECC01-B) Occupancy Sensing Sequence of Operation

GUARDIAN : AUTOGUARD. User Manual

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

DS160/161 Request To Exit PIR sensors Installation Instructions

DS160/DS161 Request To Exit PIR sensors Installation Instructions

Ceiling Microwave presence/absence detector 12-24V AC/DC

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Wireless Alarm system s manual

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Installation Instructions

Wireless Plug Load Control

Appendix A Equipment Used to Monitor Hotels

Living Space Sensor Touchscreen Covers SXWSCDXSELXX (Touchscreen Display) SXWSCDPSELXX (Touchscreen Display with Occupancy Sensor)

Sensors Explained AUTOMATION

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

LPCMPIRM65 & LPCMPIRDSI65

Operating Instructions

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

Wireless Occupancy Sensor:

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

Intrusion. Outdoor protection perimeter

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Zilog s ZMOTION Detection and Control Family. Featuring PIR Technology

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Wireless Driveway and Intruder Alert

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Infrared Ceiling Mount Sensor

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

TRUST WIRELESS ALARM SYSTEM 200S

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Owner s Manual. Part Number 33CS250-RC

ZMOTION Lens and Pyroelectric Sensor

ETN1000/MIGA - Operating manual

Verasys System Operation Overview Technical Bulletin

Sensor Interface Module Installation/Operation Instructions

Wireless Thermostat (WTS10) Keypad Operation Guide

SPACE DETECTOR SP Presentation

Installation Instructions

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

Transcription:

PIR Cover Install Guide for PIR Cover for SE7000 Room Controller

Overview 2 The acccessory covers with embedded Passive Infra-Red (PIR) motion detector have been specifically designed to work with all compatible SE7000 Series Room Controllers. Any Room Controller compatible with SE-PIR covers uses these7xxxxx5xxx(x) assignment. The 5 identifies the Room Controller base has the necessary onboard polarized PIR connector and functionality added. When equipped with a PIR cover, a SE7000 series Room Controoler provides advanced active occupancy logic, which automatically switches occupancy levels from Occupied to Stand-By, as well as Unoccupied as required by local activity being present or not. Models Available The below table shows which PIR covers are compatible for which model. PIR COVER PART NUMBER DESCRIPTION COMPATIBLE MODEL COV-PIR-FCU-C-5000 PIR cover with Commercial FCU interface SE73x0X5x00(X) COV-PIR-FCU-L-5000 PIR cover with Hotel/Lodging interface SE73x5X5x00(X) COV-PIR-RTU-5000 PIR cover for roof-top thermostats SE76xxX5x00(X) COV-PIR-ZN-5000 PIR cover for zoning thermostats SE7200X5x00(X) Instalation Tips TIP DESCRIPTION EXPLANATION General Installation PIR Connector Polarized connector is located at bottom left hand corner of Room Controller General Installation Security Screw A security screw is provided in the shipping box. This screw should be carefully installed in the intended mounting position located at bottom center of cover. Initial Power Up & Commissioning PIR warm-up period PIR Sensor may take up to 60 seconds after initial warm-up period to detect movement consistent with typical detection pattern. Initial Power Up & Commissioning Visual indication (status of PIR) Visual indication of PIR activity for commissioning shows via blinking LEDs located on the cover under the PIR lens. LEDs stay active while occupant is in field of detection pattern for a period of 30 minutes after initial power up. Safety Electronic controls are static sensitive devices. Discharge yourself properly before manipulation and installing the Room Controller and its accessories. Short circuit or incorrect wiring may permanently damage the device or the equipment. All SE7000 series Room Controllers are to be used only as operating controls. Whenever a control failure could lead to personal injury and/or loss of property, it becomes the responsibility of the user to add safety devices and/or alarm systems to protect against such catastrophic failures.

Typical PIR Lens Detection Pattern 3 Typical detection pattern for the PIR cover is illustrated below. 140 O Side view 60 O 15 O 25 O 25 O 15 O 15 O 15 O 20 ft 16 ft 13 ft 13 ft 16 ft 20 ft (6 m) (5 m) (4 m) Top view (4 m) (5 m) (6 m) 20 ft (6 m) Fresnel lens beam and detection field Forward movement Lateral movement 140 O 20 ft (6 m) 20 ft (6 m) Top view

Deployment 4 It is recommended to install the Room Controller as close to a door as possible (but not so as to be blocked by the door), or in an area with high occupant movement. Ideally the Room Controller should be installed 5 feet (1.5 meters) above the floor surface to ensure maximum detection range is achieved. As well, Room Controller placement should ensure the occupant crosses the lens beam in a perpendicular path within the prescribed detection zone. Example of Recommended Deployment The below shows Room Controllers installed in ideal locations for two rooms. The examination room shows one Room Controller installed adjacent to the door. In this area of the room, occupant traffic is high and ensures the occupant will almost always cross the PIR detection path laterally and within the detection range. The waiting room shows one Room Controller installed beside a door in the middle of the room. As shown in the diagram below, occupant traffic is high in several areas of the room including the entrance, waiting room, access to the door and activity around the reception desk. Moreover, for each case aforementioned, occupant movement almost always moves lateral to the PIR, which ensures detection by the PIR, as well as respecting the PIR detection range of 20 feet (6 meters) at 140, and 16 feet (5 meters) between 15 to 30 laterally. Recommended Installation

5 Example of Non-Recommended Deployment The below shows four Room Controllers (two for each room) installed in non-ideal locations for the two rooms. The examination room shows one Room Controller installed in a low traffic area near the door, and a second Room Controller installed on the wall directly opposite the door. For the Room Controller installed in the corner wall near the door, the PIR could be blocked by the opened door, thereby restricting PIR detection. For the second Room Controller installed opposite the door, the PIR detection could fall outside the specified detection zone, while at the same time most occupant movement may not respect lateral crossing patterns for PIR detection. The waiting room shows one Room Controller installed near the entrance, and a second Room Controller installed beside the reception area. For the Room Controller installed at the entrance, the opening/closing of the door creates high probability the PIR would get blocked, and therefore, occupancy going undetected. For the Room Controller installed beside the reception area, occupant traffic could fall outside the detection zone, while the receptionist would often be below the 5 foot recommended installation height for the Room Controller. Non-Recommended Installation

Installation 6 This procedure shows how to install the PIR cover. PIR COVER 1. Remove security screw on bottom of current Room Controller cover. 2. Open by pulling on bottom side (Fig. 1). Fig. 1 3. Locate male polarized PIR connector at bottom left corner (Fig. 2). Fig. 2 4. Hinge new PIR thermostat cover into position (Fig. 3). Fig. 3 5. Insert polarized connector into PIR female connector located on thermostat base (Fig. 4). 6. Snap PIR thermostat cover into place and re-install the security screw. 7. Set appropriate parameter settings. Refer to Install Guide. Fig. 4

7 PIR LED STATUS The PIR covers have two green status LEDs behind the PIR lens used for diagnostic purposes during commissioning or servicing. The LEDs are used to indicate local movement detected by the PIR cover according to the following: The status LEDs will only start functioning to indicate movement 1 minute after the initial power up of the Room Controller (24 Vac). The status LEDs will stop functioning to indicate movement 30 minutes after the initial power up of the Room Controller (24 Vac). LEDs location on PIR cover under the main sensor lens

Technical Support 8 For any issues with SmartStruxure Solution or SmartStruxure Lite, contact Schneider Electric Technical Support according to your region. AMERICAS +1-(978)-975-9508: Andover, MA, USA, 8:30am - 5:00pm (EST) +1-(800)-830-1274: Carrollton, TX, USA, 8:00am - 5:00pm (CST) +1-(888)-444-1311: Rockford, IL, USA, 8:00am - 5:00pm (CST) EUROPE +44-1628-741-147: London, England, UK, 8:00am - 4:30pm (GMT) +46-40-38-69-00: Malmö, Sweden, 8:00am - 4:15pm (CET/CEST) ASIA PACIFIC Contact Technical Support at https://ecobuilding.schneider-electric.com/support