GENYO Series ELECTRIC PUMP CONTROL AND PROTECTION SYSTEM

Similar documents
Ecocirc D5vario DC pumps DIRECT OR BATTERY POWERED FROM 8-24 VOLT, WITH SPEED CONTROL

NEW Lowara ecocirc PRO The new high efficiency domestic hot water PumPs with automatic air venting function and TheRmaL insulation shell

Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY

Pressure booster sets for residential and commercial buildings A COMPLETE RANGE OF SOLUTIONS FOR IMPROVED SYSTEM PERFORMANCE

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC

Lowara ecocirc and ecocirc PREMIUM

Lowara ecocirc and ecocirc PREMIUM

Flygt MAS 711. Monitoring system for Flygt pumps

Flygt 3153, 3171, 3202, 3301, 3315, 5100, Replacing Cooling Liquid In Pumps with Cooling Jackets

Extended Range. PRESFIX Packaged Pressurisation Sets AUTOMATIC MAKE-UP UNITS FOR SEALED HEATING AND CHILLED WATER SYSTEMS.

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

Lenntech. Tel Fax bar. Multistage Pumps.

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

WEDECO Quadron UV System

TECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS

ViscoClock plus AUTOMATIC VISCOSITY MEASUREMENT EASY AND PRECISE

SIMPLEX WEATHERPROOF CONTROL PANELS

Quadron UV Series. Sustainable UV Disinfection with Minimum Footprint

Volute Casing Pumps. Vogel Series LN/L ACCORDING TO EN 733 DE: +41 (0) FR: +41 (0)

Flygt Top-Entry Agitators CONVENIENT AND EFFICIENT

Sewage Pumps. KS - Channel Type Pumps W, WTS - Vortex Type Pumps

Domestic Building Services Product Guide

Affordable efficiency!

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

Domestic Building Services Product Guide

Domestic Building Services Product Guide

Elevator Sump Kits and Components

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

HRV Enthalpy. Catalogue

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

Inline Pumps LR/LMR & LRZ/LMZ, LER & LEZ. Lenntech. Tel Fax

Spektron UV Series SHINING NEW LIGHT ON DRINKING WATER DISINFECTION

OPERATING MANUAL. ba75825e03 12/2015 LR 925/01 LR 925/01-P LR 925/01(-P) ULTRAPURE WATER CONDUCTIVITY MEASURING CELL

Hydronic electric heating

Jabsco Marine Toilets SIMPLY RELIABLE SOLUTIONS FOR EVERY BOAT AND BUDGET

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

Technical Sheet. Heat recovery appliance Renovent Excellent 180 (Plus) Renovent Excellent 180 1

NEW. Lowara e-mp Series. HIGHLY EFFICIENT AND FLEXIBLE MULTISTAGE PUMPS UP TO 1.250kW / 1.700hp. Applications limited only by your imagination

COMMERCIAL HEATING & PLANT

SMOevo Ozone Systems MAXIMIZE THE OZONE. MINIMIZE THE ENERGY.

>>> Rack Environmental Management

Marine Heat Exchangers SALES SERVICE REPAIR

EN aquatech.piovan.com

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

DRAINAGE AND SEWAGE. DRENA-LINE Residential Technology

Systems for central heating

QUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions

ACT-4 AC Electronically Commutated Spherical Motor Centrifugal Pump Kit

The Right Temperature, Always THS Series Modular Thermostats

Edition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL)

Pumpco Sdn. Bhd. Solar Water Heater. 1 of 8 MAIN FEATURES OF SOLARMATE

industrial, safety and security signalling products reference catalogue 2008/9

LS Condensate Removal Pump Installation, Operation and Service Instructions

More Precision. indusensor // Linear inductive displacement sensors

Packaged pump solutions

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar abs) Press. (bar g) (kg)

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

A strong group. For your success.

M7100 Pressure Transducer

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

Level gauges Series LS Level indicator, switch and transmitter for liquids

CAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS

Monticello Pump Services, Inc

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

Constant Water Pressure Systems and Accessories

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Q-SMART MODBUS KIT. Modbus Protocol & Parameters. Cod EN rev.a ed.08/2018. Q-SMART Software Version AE17

Edition 8, From serial no Publ. no OM 5030, Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL)

6800 Design Envelope Booster. Technical overview

Architectural Lighting

Geomembranes that work

MULTIPLE COMPRESSOR SYSTEMS COMPRESSOR PACKAGES ORIGINAL MANUFACTURED EQUIPMENT. Multiple Compressor Systems BA AUS

GRUNDFOS STAINLESS STEEL PUMPS PDF

recooler HP EQKR HEAT PUMP

Electronic timeswitch

CONTROLS FOR ELECTRIC RADIATORS AND TOWEL RAILS

Metso MX. Multi-Action cone crusher

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

USERS MANUAL FOR GAS BOILERS

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

Emerson Superheat Control. The smart solution for your application

LORAIN CIP 4890/48120 DC Power System

TR FLEXMAG 4050 C Electromagnetic flow meter for single use processes

Water and ground source heat pumps 61WG kw. Heating

Industrial cooling systems LT

The POWERTANK. Range A PACKAGED SOLUTION FOR BOOSTING WATER. by Pedrollo Distribution. powertank.co.uk

Product Catalog. Condensate Removal Ice Machine Replacement Evaporative Cooler Accessories. Engineered Products HVAC. Industrial

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Edition 6, From serial no Publ. no Orwak 5030-CE. Operating manual

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

RAK THE OPTIMUM RANGE FROM REFCOOL THE ENERGY REVOLUTION. Industrial chillers - 0 to 200 kw

SATK 30 heat interface unit

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

2. General information Page Warnings Page Technical characteristics Page Installation Page Front panel Page 7

FTA200-A REMOTE ALARM PANEL

JET, PERIPHERAL TURBINE, HORIZONTAL MULTISTAGE & CENTRIFUGAL PUMPS + ELECTRONIC PRESSURE CONTROLLERS & WATERGATE PRO RS ABOVE GROUND PUMPS

Transcription:

GENYO Series ELECTRIC PUMP CONTROL AND PROTECTION SYSTEM

Electric pump control and protection system 02

Applications. Domestic pressure boosting (single and multi-family dwellings) Small irrigation and gardening Civil water systems (bathing establishments, campgrounds, sporting facilities) Xylem introduces Genyo, the new range of compact electronic devices, pressure/ flow switches for control and protection of electric pumps. Genyo is controlled by an electronic circuit and is composed of a diaphragm and counteracting spring system integrated with flow and pressure sensors. Genyo enables automatic control of pump start-up and shutdown based on actual water demand, preventing any pressure fluctuations at delivery points with constant operating point. Genyo integrates multiple system controls into a single device. Benefits. Protection against dry running integrated in the device No maintenance required (a convenient alternative to traditional diaphragm surge tanks) Quick and easy installation Compact size Stable pressure without fluctuations at constant operating point Back-up tank to compensate for small leaks or drips in the hydraulic system (patented system) Limited flow resistance For GENYO 16A model only. Automatic restart in case of water failure Adjustable starting pressure 03

Product range. GENYO 8A GENYO 16A Model Accessories included Max current Start pressure GENYO 8A/F12 Pressure gauge 8A Fixed start P: 1.2 bar GENYO 8A/F15 Pressure gauge 8A Fixed start P: 1.5 bar GENYO 8A/F22 Pressure gauge 8A Fixed start P: 2.2 bar GENYO 16A/R15-30 Pressure gauge 16A Adjustable start P: 1,5 3,0 bar * Version with Power Supply Cable / Plug and Motor Cable also available (for technical details, see Technical Specifications section) Suitable for use with both surface and submersible electric pumps 04

Construction characteristics. LARGE PASSAGEWAY for lower flow resistance SPRING made of bichromate Treated steel LIQUID END MATERIAL Made of non-toxic fibreglassreinforced thermoplastic material DIAPHRAGM AND SEALS of special natural rubber for higher protection (ip 65) PATENTED STORAGE SYSTEM Permitting the storage of an adequate water reserve in a limited space ELECTRONIC BOARD For control, protection and connections SENSORS Made of highly resistant thermoplastic material containing hermetically inserted ultrasonicwelded magnets NON-RETURN VALVE Integrated into one of the sensors with magnet LED INDICATORS GREEN LED: POWER presence of power supply RED LED: FAILURE indicates an alarm condition YELLOW LED: ON indicates the pump is running MANUAL RESTART PUSHBUTTON to restart the pump after failure INTEGRATED PRESSURE GAUGE Range: 0-10 bar POWER SUPPLY CABLE AND PLUG / MOTOR CABLE only on version with cables 05

Product range. GENYO 8A. Power supply voltage: single phase 220-240V Frequency: 50/60 Hz Max current: 8A inductive Protection class: IP 65 Fixed start pressure: F12: 1.2 bar F15: 1.5 bar F22: 2.2 bar Operating temperature: 0-60 C Max pressure: 10 bar Max flow rate: 10 m 3 /h (see flow resistance diagram) Manual restart Inlet-outlet connections: R1 Pressure gauge (0 10 bar) Power supply cable and plug /motor: H07RN-F 3G1 - L = 1.5 m with Schuko* plug / H07RN-F 3G1 L = 0.5 m with cableheads (on version with cables) * UK, AU plug available on request GENYO 16A. Power supply voltage: single phase 220-240V Frequency: 50/60 Hz Max current: 16A inductive Protection class: IP 65 Adjustable start pressure (by means of special screw): R15-30 from 1,5 to 3,0 bar Operating temperature: 0 60 C Max pressure: 10 bar Max flow rate: 10 m 3 /h (see flow resistance diagram) Automatic restart Inlet-outlet connections: R1 Pressure gauge (0 10 bar) Power supply cable and plug /motor: H07RN-F 3G1.5 - L = 1.5 m with Schuko* plug / H07RN-F 3G1.5 L = 0.5 m with cableheads (on version with cables) * UK, AU plug available on request 06

Standards and markings. Suitable for use with potable water (French ACS approval and according to D.M. 06/04/2004 n. 174) In compliance with Directive 2002/95/CE (RoHS) According to 2006/95/EC (Low Voltage Directive) According to 2004/108/EC (EMC Directive) EN 60730-2 - 6, EN 61000-6 - 2:2005, EN 61000-6 - 3 :2001 C-Tick approval Dimensional data. GENYO 8A GENYO 16A Flow resistance diagram. GENYO 8A GENYO 16A 07

What can Xylem do for you? Xylem 'zīl m 1) The tissue in plants that brings water upward from the roots; 2) a leading global water technology company. We re approximately 12,700 people unified in a common purpose: creating innovative solutions to meet our world s water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to xyleminc.com. LOWARA S.r.l. Unipersonale Via Vittorio Lombardi, 14 36075 Montecchio Maggiore Vicenza - Italy Tel. (+39) 0444 707111 Fax (+39) 0444 492166 e-mail: lowara.mkt@xyleminc.com www.lowara.com www.completewatersystems.com cod. 191000761 - P02/13 Lowara is a trademark of Xylem Inc. or one of its subsidiaries. Lowara reserves the right to make modification without prior notice.