Excellent ecodan s heating performance, even at low outdoor temperature! INDOOR UNIT. Hydro box ERSC OUTDOOR UNIT

Similar documents
ECODAN ecodan can heat rooms and supply domestic hot water, realising greater comfort and energy saving.

Excellent ECODAN s heating performance, even at low outdoor temperature!

Excellent ECODAN s heating performance, even at low outdoor temperature!

Excellent ecodan s heating performance, even at low outdoor temperature! Small capacity. Packaged type. Small capacity (Under 5kW)* SUHZ-SW45

PACKAGED TYPE. Water heat exchanger is built in the outdoor units. OPTIONAL PARTS LIST. Step Interface 3) Flow Temperature Controller 3)

Central Home Heating and Hot Water Supply

Air to water Heat Pump System

2012 Heating Price List. Price List Heating 1st November Mitsubishi Electric is a market leader in renewable solutions.

Do you want a versatile solution

Air to water Heat Pump System

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

AIR CONDITIONING SYSTEMS

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q ***

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

FLOW TEMP. CONTROLLER 2B (Cased) PAC-IF032B-E

Tel: Heronhill - For all your Toshiba heating and cooling requirements Air to water Heat Pump System

Sweden s leading air source heat pump

Inverter Hot Water Heat Pumps

THE HEAT PUMP CHOICE OF PROFESSIONALS

Samsung Eco Heating System

For safe and correct use, please read this operation manual thoroughly before operating the cylinder unit and the hydrobox.

FLOW TEMP. CONTROLLER 2B (Cased) PAC-IF032B-E

2009 Panasonic Marketing Europe GmbH / All rights reserved

Hot Water Heat Pump Catalogue

HITACHI line up: YUTAKI S 80 Very high water temperature Heat Pump

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

FLOW TEMP. CONTROLLER 3 (Cased) PAC-IF041B-E

AIR-HANDLING UNIT (AHU) DESIGN GUIDELINE

Quick Reference. Air to Water Heat Pump Series 4 Lot 1 Standard & Powerful Types

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

HEAT PUMPS LINE AS AIR TO WATER

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

HT V2 HT Split

Mitsubishi Electric's

Samsung System Air Conditioner Eco Heating System

HEAT PUMPS FOR HEATING AIR-TO-WATER

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

WHY A MHI HEAT PUMP?

FREQUENTLY ASKED QUESTIONS

LZT High efficiency air to water heat pumps with E.V.I. compressors

TOSHIBA AIR CONDITIONING

AQUAHEAT ADVANCE SPLIT

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

LZT High efficiency air to water heat pumps with E.V.I. compressors

PROMATIC WDC Heating controllers Energy under control

PRODUCT LINEUP AIR TO WATER. For RESIDENTIAL. Room Heating & Cooling

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

Split Type System. Air to Water Heat Pump

DESIGN & TECHNICAL MANUAL

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

PUHZ-SHW140YHA PUHZ-SHW230YKA

Bringing a year round comfort solutions to extreme climates

Samsung Air Conditioning

A +++ R32 Daikin Altherma 3 powered by Bluevolution. Why choose Daikin Altherma 3? 65 C

Hot water supply. Indoor unit. Domestic hot water tank. Take thermal energy from atmosphere. Outdoor unit

Natural geothermal energy

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

HEAT PUMPS FOR HEATING AIR-TO-WATER

FLOW TEMP. CONTROLLER [MASTER] (Cased) PAC-IF061B-E PAC-IF062B-E PAC-IF063B-E. FLOW TEMP. CONTROLLER [SLAVE] (Cased) PAC-SIF051B-E

Efficient heating that won t cost the earth

WALL MOUNT COMBINATION GAS HEATER SERIES. HIGH EFFICIENCY HYDRONIC HEATERS WITH BUILT-IN DOMESTIC HOT WATER

FUTURE SOLUTION OF DOMESTIC HEATING. Air to Water

Hot Water Heating Systems

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

DESIGN & TECHNICAL MANUAL

The Benefits Really Add Up

Heat Pump Air Conditioning Systems

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

NUOS RANGE HEAT PUMP WATER HEATERS

SERVICE MANUAL. R410A Outdoor unit [Model Name] SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. December 2013

Ducted Air Conditioning

PRODUCT LINEUP AIR TO WATER For RESIDENTIAL

OPERATION MANUAL. Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

Simply renewable A ++ A +++ ROTEX air-to-water heat pump

S-Therm Air to Water Heat Pumps

Ecodan Aerocyl Plus-me: Air Source Heat Pump and Stainless Steel Cylinder

WARNING PRECAUTION OF LOW TEMPERATURE

GEYSER kw. General information. Unique selling points

HIWARM COMPACT kw

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

Air to Water Heat Pump

SERVICE MANUAL. R410A Outdoor unit [Model names] SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. September No.OCH526

ECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps.

Owner s Manual AIR TO WATER HEAT PUMP. Hydro Unit HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E

Press. Heat pumps from Viessmann: efficient heat generation with renewable energy and electricity

Starting current with soft starter Fuse protection

WH-UD03HE5 WH-UD05HE5 WH-SDC03H3E5 WH-SDC05H3E5. Destination Europe Turkey WARNING

User Manual. Vanvex Optima 180 Domestic Hot Water. Version

High temperature air-to-water heat pumps

Transcription:

ECODN ecodan can heat rooms and supply domestic hot water, realising greater comfort and energy saving. ecodan Economic, eco conscious next generation heating system Both energysaving and safe for the environment, the Mitsubishi Electric ecodan incorporates a highly efficient heat pump system that captures the heat in the air, a renewable energy resource. Equipped with advanced inverter control, meticulous control assures comfortable heating, and its spacesaving llinone indoor unit is easy to install. These energysaving, high comfort and simple installation characteristics have drawn the ecodan heating system into the spotlight centre stage. Excellent ecodan s heating performance, even at low outdoor! INDOOR UNIT Cylinder unit (Reversible) ERSC EHSC/EHPX EHST0C/EHPT0X OUTDOOR UNIT Split type Packaged type SHW0 SW00/0 SW75 SW0/50 HW/0 W85 W50

Unique technology of ecodan uto daptation ecodan Maximize energy savings while keeping comfort at all times Settings can be performed using an SD card. iming to realise further comfort and energy savings, Mitsubishi Electric is proud to introduce a revolutionary new system control. This is based on data indicating that a drop in the flow improves the coefficient of performance (COP) of the TW system by %. This means that energy savings are dramatically affected by controlling the flow in the system. In conventional system control, the flow is determined based on the preset heat curve depending on the actual outdoor. However, this requires a complicated setting to achieve the optimal heat curve. Heat curve setting (Example) Flow temp. 60 0 If flow is COP is lowered improved % 5 0 Outdoor temp. Mitsubishi Electric s uto daptation function automatically tracks changes of the actual room s and outdoor s and adjusts the flow accordingly. Our more evolutionary uto daptation function measures the room and outdoor, and then calculates the required heating capacity for the room. Simply stated, the flow is automatically controlled according to the required heating capacity, while optimal room is maintained at all times, ensuring the appropriate heating capacity and preventing energy from being wasted. Furthermore, by estimating future changes in room, the system works to prevent unnecessary increases and decreases in the flow. ccordingly, uto daptation maximises both comfort and energy savings without the need for complicated settings. Two Controls simulation on a day Room slightly increases Temperature/ Load Curtain opened Ventilation fan turned on Increase in Lights occupants turned off Changes in room conditions Flow decreases Room decreases Flow slightly increases The flow through the system controlled via conventional heat curve The flow through the system controlled via Mitsubishi Electric s uto daptation function Energy savings Comfort 6:00 :00 8:00 :00 Time Flow temp. Room temp. Temperature setting Outdoor temp. Future room estimation Room temp. (a) Higher than the target room temp. lower the flow temp. Target temp. (b) pproximately same as the target temp. keep the flow temp. (c) Lower than the target room temp. raise the flow temp. Modify the flow by comparing actual and estimated room. points T0 T Future Time llinone & compact Small overall size contributes to easy transportation, installation and maintenance Simplified: ll key functional components are incorporated into the unit. Easy servicing: Relevant parts are located at the front of the unit to access easily. Easy to transport and install using the attached handle both at front and at back (cylinder unit) and also back plate (hydro box unit). Easy to open the packaging without using knife. Compact hydro box unit CONTROL ND ELECTRICL BOX *EXPNSION VESSEL Compact cylinder unit *EXPNSION VESSEL (behind) CONTROL ND ELECTRICL BOX WY VLVE WTER PUMP MNOMETER HNDLES (back) MIN REMOTE CONTROLLER PUMP VLVE *PLTE HET EXCHNGER BOOSTER HETER *PLTE HET EXCHNGER TNK BOOSTER HETER STRINER FLOW SWITCH (behind) PRESSURE RELIEF VLVE (behind) MIN REMOTE CONTROLLER MNOMETER STRINER DJUSTER HNDLE *IMMERSION HETER FLOW SWITCH *Depending on model 5

Designed for Optimal ZUBDN New Generation (Split type) Improved heating performance more efficiently ZUBDN is equipped with a unique Flash Injection Circuit that enables the system to provide powerful heating in cold regions during the winter months. nd more evolved ZUBDN New Generation incorporates a new compressor that is more efficient, further improving heating performance when outdoor s is low. The rated heating capacity can now be maintained at 5 even including defrost, making it possible to supply comfortable heating in ever more severe environments. Integrated capacity () pprox. % higher than our previous model! 5 0 Nominal capacity can be kept at 5! ZUBDN ZUBDN New Generation 5 0 5 7 0 Outdoorair at intake duct W5 (according to EN 5) Max. possible flow temp. (deg C) 65 60 55 50 5 5/W55 possible! ZUBDN New Generation Ideal for DHW! 0 0 5 0 5 0 5 0 Outdoor temp. Mitsubishi Electric s Flash Injection Technology The Key to High Performance at Low Outdoor Temperatures Flash Injection Circuit ZUBDN New Generation Injection compressor (injection port) Flash Injection Circuit Indoor HEX Power receiver B Outdoor HEX Heat Interchanger (HIC) LEV B LEV Refrigerant flow LEV C Heat interchanger (HIC) Flash Injection Circuit B Injection Compressor The Flash Injection Circuit is an original technology developed by Mitsubishi Electric. heat exchange process at point (heat interchanger) transforms liquid refrigerant into a twophase, gasliquid state and then compresses the gasliquid refrigerant at point B (injection compressor). This circuit secures a enough flow rate of refrigerant for heating when outdoor s are very low. In the ZUBDN New Generation, the Flash Injection Circuit is more powerful by improving the heat interchanger to increase the heatexchangeefficiency and incorporating new injection compressor to increase the compressionefficiency. These two improvements of ZUBDN New Generation ensure reliable, efficient heating operation when outdoor s are very low. 6

SD* CRD *SD logo is a trademark of SDC, LLC The ecodan evolution continues! For easier settings and for data loggings Settings can be performed using an SD card. Initial setting for ecodan is now simpler than ever before. The special software enables the required initial settings to be saved to an SD card using a personal computer. System setup is as easy as moving the SD card from the computer to the SD card slot in the indoor unit. Compared to the previous procedure of inputting settings using the main controller at a installation field, a remarkable reduction in setup time has been achieved. Thus, it is ideal way for busy installers. *SD card fanction is only used by installer. inside Printed circuit board Settings can be performed easily and logging operation data in SD card can be confirmed via personal computer. Control and electric box SD card slot SD card SD card Items that can be preset Simply copying the preset data to SD card, same settings are complete in multiple units easily. Initial settings (time display, contact number, etc) settings uto daptation Heat curve Two different s zones Interlocked boiler operation settings Holiday mode settings Schedule timer settings Domestic hot water settings Legionella prevention settings ll items that are set by the main controller can be set via a personal computer. Data that can be stored Operation data up to a month long can be stored on a SD card (GB). Operation time Defrost time ctual Room Flow Return Domestic hot water Outdoor Error record Input signal etc. Stylish, easytoread bright LCD with ergonomically designed intuitive interface Main controller Large screen and backlight for excellent visibility, even in dark environment Multilanguage support ( languages) Can be removed from main unit and installed in remote location (up to 500m) Wide range of convenient functions in response to user demand Functions settings Weekly timer Holiday mode Legionella prevention Error codes and data for serving NEW Two zone control Boiler interlock Floor drying up Quick reading of operation data (7.5 times faster than previous model) Wireless remote controller (optional) Builtin room sensor; easy to place in the best position to detect room Wiring work eliminated Simple design that is easy to operate Remote control from any room without needing to choose an installation location Backlight and big buttons that are easy to operate Domestic hot water boost and cancellation Simplified holiday mode Up to 8 controllers allowed (can be set for zone or individually) PRWR5RE (optional) Receiver Main controller PRWT50RE (optional) Wireless remote controller 7

Two zone control Simultaneously making two different zones assures more comfortable, highly convenient heating Settings can be performed using an SD card. ecodan makes it possible to set two s which are used in two different types heat emitters in a system. The system allows adjustment of s when different room s are required, such as a of 0 for the living room radiator and of 0 for floor heating. dditionally, the scheduling for each zone can be set separately by main controller. Two zones * Pump Mixing control Mixing valve 0 Flow switch Radiator Pump 0 Mixing tank Flow switch Underfloor heating * = Flow controller *Items such as mixing tank, mixing valve, flow switch and pumps are not included and need to be purchased locally. Intelligent boiler interlock No need to replace existing boiler! utomatic switchover enables even more efficient operation Settings can be performed using an SD card. The flexibility of ecodan s intelligent control allows the system to be combined with boiler currently in use. dditionally, this control can judge which heating source (ecodan, or boiler) to be operated according to situations (outdoor, running cost, CO emission level etc.). Customers using a boiler can receive the energysaving performance of ecodan. Intelligent system combining a boiler with ecodan Two zones Room wireless remote controller (option) Electricity *Thermostat (field supply) also can be used. Turning boiler on/off according to operational conditions. Pump Radiator Radiator Other source (Gas, Oil, etc) Mixing tank Boiler *Items such as mixing tank and pump are not included and need to be purchased locally. Multiple unit control Connect up to 6 units utomatic control of multiple units to supply bigger capacity Settings can be performed using an SD card. maximum of 6 ecodan units* can be configured according to the required heating/cooling load of the building. The most efficient number of operating units is determined automatically based on heating/cooling load. This enables ecodan to provide optimal room control, and thus superior comfort for room occupants. lso incorporated is a rotation function that works to balance the running hours without depending on the operation of any one specific unit. If one of the units malfunctions when using Multiple Unit Control, another unit can be automatically operated for backup, thereby preventing system operation from stopping completely. Multiple unit control COP ratio (%) 00 unit units units units 5 units 6 units lways high efficient operation! ON/OFF control + + + + + Total Inefficient operation at low capacity. Multiple unit control One large unit control *Only same models (same capacity) are available. master Main RC Multiple unit control 8

Split type specifications Indoor unit <Cylinder unit> EHST0CVM6HB EHST0CYMHB EHST0CTMHB EHST0CVMB Type Iersion heater Expansion vessel Solar circuit Dimensions HWD Product weight (empty) kg 8 8 8 5 Type of installation Heater Booster 0/Single/50 00/Three/50 0/Three/50 0/Single/50 heater 6 (//6) (/6/) (/6/) 6 6 0 6 Iersion 0/Single/50 0/Single/50 0/Single/50 heater 6 6 6 Domestic Volume (net) L hot water tank Material Operating ambient condition* Target Room range Flow DHW Legionella prevention Sound level (SPL) db () EHST0CVM6B EHST0CYMB EHST0CVM6EB EHST0CYMEB EHST0CVM6SB only 60055680 7 7 8 Floor standing 0/Single/50 0/Single/50 6 (//6) 6 00/Three/50 (/6/) 6 0/Single/50 6 (//6) 6 00/Three/50 (/6/) 6 0/Single/50 6 (//6) 6 00 Stainless steel 0~5 0~0 5~60 0~60 Max 70 8 *The environment must be frostfree. <> Type EHSCVMB EHSCVM6B EHSCYMB EHSCTMB only EHSCVM6EB EHSCYMEB ERSCVMB and Cooling Expansion vessel Dimensions HWD 8005060 8605060 Product weight (empty) kg 5 5 5 5 5 Type of installation Wall mounted 0/Single/50 Heater Booster heater 0/Single/50 0/Single/50 6 (//6) 00/Three/50 (/6/) 0/Three/50 (/6/) 0/Single/50 6 (//6) 00/Three/50 (/6/) 0/Single/50 6 6 Domestic hot water tank Volume (net) Material L 6 6 6 6 Operating ambient condition* Target range / Cooling Room Flow Cooling Cooling 0~5 0~5 0~5 0~5 0~0 5~60 0~5 0~5 0~5* N/ 5~5 DHW 0~60 Legionella prevention Max 70 Sound level (SPL) db () 8 * The environment must be frostfree. * Low outdoor cooling is not allowed (minimum 0). Outdoor unit Dimensions HWD Product weight (7/W5) COP Power input (/W5) COP Power input Sound level (SPL) Sound level (PWL) kg db () db () PUHZ SW0VH (BS) 60080000.0.80 0.85.00..5 5 6 PUHZ SW50VH (BS) 60080000 6.00..57 5.00.7.68 6 6 PUHZ PUHZ PUHZ PUHZ PUHZ PUHZ PUHZ SW75VH (BS) SW00V/YH (BS) SW0V/YH (BS) SHW80VH SHWV/YH SHW0YH SHW0YK* * 500 75 50500 8 / 0 50500 8 / 0 50500 0 50500 0/ 50500 80500 8 VH : 0/Single/50 YH : 00/Three/50 8.00.0.8 7.50.0.06 5 6.0.5.57 0.00..00 5 70 6.00.0.0.00..70 5 7 8.00.65.7 8.00.55.5 5 6.0.6.5.0..5 5 70.00..8.00.6.70 5 70.00.65 6.0.00.7.60 5 76 Note: based on EN 5 (Circulation pump input is not included.). It may differ according to the system configuration. * PUHZSHW0YK can not be connected to ecodan indoor unit. * The performance data is obtained when plate heat exchanger (CH 700) are connected.

Optional parts <Indoor unit> Parts name Specification Cylinder unit Wirelss remote controller Wirelss receiver s Iersion heater Joint pipe Contents PRWT50RE PRWR5RE PCSETSE PCTH0E PCTH0TKE PCTH0HTE PCIH0VE For room temp. For buffer and zone (flow and return temp.) For tank temp. For boiler (flow and return temp.) Ph PCSH0RJE PCSH50RJE For PUHZSW0/50VH (BS) ø.5 For PUHZSW0/50VH (BS) ø5.88 ø6.5 ø.70 EHST0C VM6HB EHST0C YMHB EHST0C TMHB EHST0C VMB EHST0C VM6B EHST0C YMB EHST0C VM6EB EHST0C YMEB EHST0C VM6SB EHSC VMB EHSC VM6B EHSC YMB EHSC TMB VM6EB EHSC YMEB EHSC ERSC VMB <Outdoor unit> Parts name Power inverter ZUBDN PUHZ PUHZ PUHZ PUHZ PUHZ PUHZ PUHZ PUHZ PUHZ SW0VH(BS) SW50VH(BS) SW75VH(BS) SW00V/YH(BS) SW0V/YH(BS) SHW80VH SHWV/YH SHW0YH SHW0YK * Connector for drain hose heater signal output PCSE60RE ir discharge guide PCSG58SGE PCSG5SGE PCSG6SGE ir protection guide PCSG56GE PCSH6GE PCSH5GE PCSG6DSE PCSH7DSE Centralised drain pan PCSG6DPE PCSG6DPE Control/Service tool PCSK5ST * PUHZSHW0YK can not be connected to ecodan indoor unit. <Interface/Flow controller> Parts name Description Power inverter ZUBDN PUHZ PUHZ PUHZ PUHZ PUHZ PUHZ PUHZ PUHZ PUHZ SW0VH(BS) SW50VH(BS) SW75VH(BS) SW00V/YH(BS) SW0V/YH(BS) SHW80VH SHWV/YH SHW0YH SHW0YK step control interface PCIF00E* 0 s w/o case * * * * * * * * * PCIF0BE w/ case Flow controllers PCIF00E* 0 s w/o case * * * * * * * * * PCIF0BE w/ case PCIF0BE w/ case System controllers PCIF05BE w/ case PCSIF05BE w/ case s PCTH0E * PCIF00E and PCIF00E are only for manufacturer s preloading. * PCTH0E is required. Parts name Contents Q ty ir discharge guide PCSG58SGE ir discharge guide Support (For the upper and lower sides) Support (For right and left) ttachment screw (50) ttachment screw (0) Spacer 8 ir discharge guide ir protection guide PCSG5SGE PCSG6SGE PCSG56GE PCSH6GE PCSH5GE PCSG6DSE PCSH7DSE ir discharge guide ttachment screw (55) Spacer ir discharge guide Support Screw (55) Washer Spring washer Front plate Side plate Side plate Connecting plate Mounting screw (0) Mounting screw () Washer (for screw ) ir guide Mounting screw (55) Washer Spring washer ir guide Mounting screw (55) Washer Spring washer Drain cap (ø) Heat insulator Band Drain cap (ø/ø) Heat insulator Band 6 6 6 5 8 7 8 Parts name Contents Q ty Centralised drain pan PCSG6DPE Centralised drain pan PCSG6DPE Centralised drain pan Control/Service tool step control interface Flow controllers System controllers s PCSK5ST PCIF00E PCIF0BE PCIF00E PCIF0BE PCIF0BE PCIF05BE PCSIF05BE PCTH0E PCTH0HTE PCTH0TKE Control/Service Tool cable (5m) cable (5m) cable (0m) SD memory card cable (0m) SD memory card for buffer and zone (flow and return temp.) for tank temp. for boiler (flow and return temp.) * One carton contains 0 s. * Two thermistors per package: 0 packages per carton * One thermistor per package: 0 packages per carton 0* 0* 0* 0* 0* 0

Packaged type specifications Indoor unit <Cylinder unit> EHPT0XVMHB EHPT0XVM6HB EHPT0XYMHB EHPT0XTMHB EHPT0XVM6B EHPT0XYMB Type only Iersion heater Expansion vessel Dimensions HWD 60055680 Product weight (empty) kg 5 5 5 Type of installation Floor standing 0/Single/50 Heater Booster heater 0/Single/50 0/Single/50 00/Three/50 0/Three/50 0/Single/50 00/Three/50 6 (//6) (/6/) (/6/) 6 (//6) (/6/) 6 6 6 6 0 6 Iersion heater 0/Single/50 0/Single/50 0/Single/50 0/Single/50 Domestic hot water tank Volume (net) Material L 6 6 6 6 00 Stainless steel Operating ambient condition* Target range DHW Room Flow 0~5 0~0 5~60 0~60 Legionella prevention Max 70 Sound level (SPL) db () 8 *The environment must be frostfree. <> Dimensions Product weight (empty) Type of installation Heater Booster heater Domestic hot water tank Volume (net) Material Operating ambient condition* Target range Room Flow DHW Legionella prevention Sound level (SPL) Type Expansion vessel HWD kg L db () EHPXVMB 0/Single/50 6 EHPXVM6B only 8005060 Wall mounted 0/Single/50 0/Single/50 6 (//6) 6 0~5 0~0 5~60 8 EHPXYMB 00/Three/50 (/6/) 6 *The environment must be frostfree. Outdoor unit PUHZ W50VH (BS) PUHZ W85VH (BS) PUHZ HWYH (BS) PUHZ HW0VH (BS) PUHZ HW0YH (BS) Dimensions HWD 70500 500 50000 50000 50000 Product weight kg 6 7 8 8 (7/W5) COP 5.00.0 VH : 0/Single/50 YH : 00/Three/50.00.8.0..00.5.00.5 (/W5) Power input COP.0 5.00..5 8.50.7.5.0...00...00. Power input.57.68.60.50.50 Sound level (SPL) db () 6 8 5 5 5 Sound level (PWL) db () 6 66 67 67 67 Note: based on EN 5 (Circulation pump input is included.). It may differ according to the system configuration.

Optional parts <Indoor unit> Parts name Specification Cylinder unit Wirelss remote controller PRWT50RE EHPT0X VMHB EHPT0X VM6HB EHPT0X YMHB EHPT0X TMHB EHPT0X VM6B EHPT0X YMB EHPX VMB EHPX VM6B EHPX YMB Wirelss receiver PRWR5RE s PCSETSE For room temp. PCTH0E For buffer and zone (flow and return temp.) PCTH0TKE For tank temp. PCTH0HTE For boiler (flow and return temp.) Iersion heater PCIH0VE Ph EHPT accessories for UK PCWK0UKE <Interface/Flow control> Parts name Power inverter ZUBDN Connector for drain hose heater signal output PCSE60RE ir discharge guide PCSG5SGE ir protection guide PCSH6GE PCSG6DSE Centralised drain pan PCSG6DPE PUHZ W50VH(BS) PUHZ W85VH(BS) PUHZ HWYH(BS) PUHZ HW0VH(BS) PUHZ HW0YH(BS) <Outdoor unit> Parts name step control interface Flow controllers System controllers s * PCIF00E and PCIF00E are only for manufacturer s preloading. * PCTH0E is required. Description Power inverter ZUBDN PCIF00E* PCIF0BE PCIF00E* PCIF0BE PCIF0BE PCIF05BE PCSIF05BE PCTH0E 0 s w/o case w/ case 0 s w/o case w/ case w/ case w/ case w/ case PUHZ W50VH(BS) * * PUHZ W85VH(BS) * * PUHZ HWYH(BS) * * PUHZ HW0VH(BS) * * PUHZ HW0YH(BS) * * Contents Parts name ir discharge guide ir protection guide Centralised drain pan step control interface Flow controllers Contents Q ty Parts name Contents Q ty PCSG5SGE ir discharge guide System controllers PCIF05BE ttachment screw (55) Spacer PCSH6GE ir guide Mounting screw (55) cable (0m) Washer SD memory card Spring washer PCSIF05BE PCSG6DSE Drain cap (ø) 5 Heat insulator cable (0m) Band 8 SD memory card PCSG6DPE Centralised drain pan s PCTH0E for buffer and zone (flow and return temp.) 0* PCIF00E PCIF0BE 0* PCTH0HTE PCTH0TKE for tank temp. for boiler (flow and return temp.) 0* 0* PCIF00E PCIF0BE PCIF0BE cable (5m) cable (5m) 0* * One carton contains 0 s. * Two thermistors per package: 0 packages per carton * One thermistor per package: 0 packages per carton