Technical Specifications. Schedule 6(i) Electric operated Autoclave (2 Drum)

Similar documents
O P E R A T I N G I N S T R U C T I O N S

O P E R A T I N G I N S T R U C T I O N S

INSTRUCTIONS CertoClav EL

Operating Instructions

AUTOCLAVE STEAM STERILIZERS (BENCH TOP)

Manual Page 1 of 8. Manual. Laboratory autoclave

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

OPERATING INSTRUCTIONS KSG 40/60-2 KSG 50/70-2 KSG 50/80-2 KSG 50/95-2

Operations Manual. Part Number: For Research Use Only

Reach-In. PLanT GROWTh. Reach-In

: 1.5kw/AC220V.50Hz (AC110V 60Hz) : 340*200*30mm (3piece) 400*200*30mm (3 piece)

Steam sterilizer AHS-75-DRY

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

USER MANUAL AND TECHNICAL MANUAL

Classic Media Operating Instructions

CONTENTS AUTOMATIC TRANSFER SWITCHES

AZTECA A LITRE STERILISER

ELECTRIC WATER BOILER

Veterinary Autoclave

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

PRODUCT CATALOG MEDICAL AUTOCLAVE.

TECHNOSKLO Ltd. Držkov

NC SERIES. Bench Top Steam Sterilizers

WITH OMRON E5CC CONTROL


laboratory & sterilization technology

requirements can be equipped with an additional product temperature control probe, and with a printer.

INVITATION FOR QUOTATION. TEQIP-II/2015/RJ1G08/Shopping/25

User Instruction Manual

Tabletop 2340 EA-D Class S Autoclave 19 Litres

DAIHAN New Generation New Steam Sterilizer, Digital Fuzzy Controlled Autoclave

LABORATORY OVENS MODELS INCLUDE: TO-152G & TOH-152G TO-152F & TO-235F DEHYDRATING OVENS MODELS INCLUDE: TD-150F TD-330F TD-500F

Cooled Incubators Series 1, 3 & 4. Instruction Manual

DOUBLE DOOR COMPACT REFRIGERATOR. User Manual MODEL:KSTRC312BW KSTRC312BB

SCHWAN INSTALLATION GUIDE

INSTRUCTIONS MODEL: MFBU WET WELL BAIN MARIE

UV Flame Supervision System

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

FN 032/055/120 DRY HEAT STERILIZERS / OVENS FN 300/400/500 DRY HEAT STERILIZERS / OVENS KD 200/400/700 OVENS EV 018 VACUUM OVEN

DEKO 190 Ward washer-disinfector

Podiaclave+ The PodiaClave+ is specifically designed for the clinic based podiatrists and chiropodists.

N-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features:

OT SERIES. Bench Top Steam Sterilizers

Draft for comments only Not to be cited as East African Standard

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

MANUFACTURERS OF: INSTRUMENTS & SERVICES. Page:01

DENTAL TABLE TOP STERILIZER SERIES S CLASS MODEL : MO-MOST-T24/45/80.

Introducing the latest model in Prestige Medical s first-class range of Advance autoclaves - Advance Pro.

MST sterilizer overview

ESPORTI IMPEX

DOMINATORPLUS ELECTRIC RANGE APPLIANCES INSTALLATION and SERVICING INSTRUCTIONS

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

LOGIC CONTROLLED DEKO 25 EASE OF USE


This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the voltages stated on the data plate.

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

Wilbur Curtis Company, Inc. Service Manual WB-10 Water Boiler

Eligibility Criteria for Participation [Qualification Requirement (QR)]

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

CLINOCLAV steam sterilizer AH-21 L

TENDER DOCUMENT FOR SUPPLY OF EPOXY MIXING & POURING PLANT

FACTORIES ORDINANCE (CAP.

Setting The Standards For A Safer Future

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

Operating instructions

INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PIE CABINET

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

Technical Data Sheet No. JS-SM-40 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER

Getinge WD14 Tablo Tabletop washer-disinfector

DEKO Washer-disinfector WASHROOM SYSTEMS

OPERATING & SERVICE PARTS MANUAL HDS-215 COMBINATION SHRINK SYSTEM

Instruction Cum User Manual For EUROLITE

INSTRUCTIONS NACHO WARMER MODELS: 1995 / 1995S

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

FLASH PAK STERILIZATION CONTAINER SYSTEM

OPERATING INSTRUCTIONS

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

Plant Growth Chamber MPGR14

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

SST2200 & Stainless Steel Steam Sterilizers SST1700 &

EZ9Plus & EZ11Plus Instructions on: Operating

STARLINE THE STAR OF KITCHEN-RANGES >> >> >> >> >> >> >> >> >>

PRE AND POST VACUUM CLASS B AUTOCLAVE

LABOKLAV. Autoclaves Made in Germany

Service Manual. Rev.1.0 February 2015 SG-30 P 5510 M

Autoclaves. Steam Autoclaves

REVISION STATUS AMENDED PAGES. Initial release D. All

PERFORM Operating Document

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

AS 50 operating manual, 2013

STERITITE INSTRUCTIONS FOR USE

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

AKOCABLE Heating Cable Solutions Electrical Tracing

OPERATING MANUAL UNIT 8 - WHITEBRIDGE INDUSTRIAL ESTATE STONE STAFFORDSHIRE ST15 8LQ ENGLAND TEL: +44 (0) FAX: +44 (0)

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

DOMINATORPLUS G3151 Fusion Range G3150 usion Boiling Top USERS INSTRUCTIONS

SN210/310/510, SQ510/810C

Transcription:

WEST BENGAL MEDICAL SERVICES CORPORATION LIMITED - GoWB Through United Nations Office for Project Services, 11 Golf Links, New Delhi-110 003 INTERNATIONAL COMPETITIVE BIDDING FOR THE SUPPLY MEDICAL EQUIPMENTS FOR THE HOSPITALS AND MEDICAL COLLEGES OF THE GOVERNMENT OF WEST BENGAL UNOPS IFB No. UNOPS/IPO/WBMSC/EQUIP/01/2010 Amendment III dated November 12, 2010 The following amendments are hereby made to the bid document for the supply of Medical Equipments for the Hospitals and Medical Colleges of the Government of West Bengal, with reference to the above mentioned IFB: Technical Specifications Schedule 6(i) Electric operated Autoclave (2 Drum) 1. Stand-alone bench top autoclave 20 Litres, automatic.single door, self sealing with high-quality silicone gasket 2. Chamber diameter ca 25 cm, depth ca 45 cm. The autoclave should have double wall sheet metal with suitable insulation in between walls. 3. Pre-set automatic cycles for unwrapped instruments, wrapped instruments/packs; 4. Slow exhaust and drying cycles 5. Two automatic programmes, approx: 2,2 bar at 134 degree C and 1,1 bar at 121 degree C. The equipment should have automatic pressure control switch / automatic water control device to ensure that the equipment does not run dry. 6. Panel reports temperature, pressure and time, low-water level, as well as system errors (f.e. door). Temperature display should be digital and pressure display should be analogue. 7. Fit with 5 L water reservoir, manual fill, autonomy for at least 10 cycles 8. Power shut-off upon completion of cycle 9. With 3 removable shelves 10. Double safety door locking device 11. Safety feature protect against over-pressure and over-temperature 12. Audible and visual alert upon cycle interruption or completion 1

13. Unwrapped cycle time: cold 30 min, hot 20 min 14. Control panel with alpha-numerical display and cycle indicators 15. Complete with 3 instruments trays 16. Power requirements: 220 V/50 Hz single phase 17. Power consumption: 3000 W 18. Device is produced by ISO 9001 certified manufacturer 19. Device is safety certified according CE 93/42 or FDA 510k or equivalent Supplied with: 1. 1 x set of 3 matching instrument baskets 2. 1 x set of 3 matching sterilizing drums 3. 1 x roll of sterilization indicator TST control spots 4. 1 x box paper sheets, crepe, for sterilization pack 5. 1 x roll tape, adhesive, for sterilization pack 6. 4 gaskets 7. 1 x spare set of fuses 8. User manual with trouble shooting guidance, in English 9. Technical manual with maintenance and first line technical intervention instructions, in English 10. List of priced accessories 11. List of priced spare parts 12. List with name and address of technical service providers in India 13. Training and installation at end-user site 14. Proposal for full service AMC, year 1 to 5, covering (i) 4 preventive maintenances per year, (ii) on-call technical interventions, spare parts and travel 2

Schedule 6(ii) Autoclave (Single Drum) Features Autoclave should be run on electric power having a dimension of at least 9 diameter and 11 height. It should be made out of best quality aluminum gauze. Locking system should be by turning and fixing lead into groove. There should be a triple safety measure Gasket release, safety valve and steam release. (a) Capacity (b) Sterilizing Temperature Thickness 11 litres Sterilizing temperature should be 120 135 o C Wall thickness of the inner chamber as well as lid should be of minimum 3mm. Power Supply 230+/-10Volts. 50Hz. Standard The apparatus should confirm to applicable IS standard with latest amendments or equivalent international standards covering Markings, Safety requirements with recommendations of safe operations. Schedule 7(i) Drum for autoclave 1. Stainless steel seamless cylindrical sterilizing drum 2. Austenitic stainless steel, composition: 8 to 10% nickel, 18 to 20% chromium 3. Lateral air vents, manually closed after sterilization 4. Thickness steel: 0.8 mm 5. Diameter : 7 +/- 0.5 6. Height : 7 +/- 0.5 7. Device is produced by ISO 9001 certified manufacturer (Certificate to be submitted) 3

Schedule 7(ii) DRUM FOR AUTOCLAVE 1. Stainless steel cylindrical sterilizing drum 2. Austenitic stainless steel, composition: 8 to 10% nickel, 18 to 20% chromium 3. Lateral air vents, manually closed after sterilization 4. Thickness steel: 0.8 mm 5. Diameter : 10 +/- 1 6. Height : 18 +/- 1 7. Device is produced by ISO 9001 certified manufacturer (Certificate to be submitted) Schedule 8(i) INSTRUMENT STERILIZER (MEDIUM) Material Design Dimensions The sterilizer shall consist of a seamless shell, having a hand-operated lid at the upper end. It shall be designed to operate on electricity, gas or kerosene (heat sources) either independently or in combination, as desired by the purchaser. The nominal inside dimensions of the shell shall be as given below, subject to a tolerance of ±2percent. 430 mm (L) X 200 mm(w) X 150 mm(h) The thickness of the stainless steel sheet used for shell, tray and lid shell be 0.90mm subject to the tolerances on thickness as specified in the relevant Indian standard. However, thickness of shell tray and lid shall not be less than 0.70mm at any place, after drawing and for handle lever, it shall be 3.00mm. the minimum thickness for handle link-connecting the handle lever and lid shall be 1.5mm. The shell shall be pressed to form a seamless container. The rim shall be so formed so as to prevent excessive steam escape. Provision shall be made at the bottom of the shell to place it properly on the table. The lid shall be made seamless, dished and shall be designed to prevent excessive steam escape and restrict the condensate within the shell, but in any case it shall not buckle, warp, or twist with load. The corners shall be rounded to suit those of the shell. The lid shall open fully (between 55 and 85 ) by single operation from its closed position. A provision shall be made to connect the link end of the handle mechanism for simultaneous opening and closing of the tray and lid. At the opening of the lid between 55 and 85 the tray shall be able to come to the top level of the shell. A mechanism connected to the lid shall be such that when the lid is open, a bracket or rest for instruments tray shall bring the seamless tray well out of the water even when the water is at the highest level. The tray bottom shall be perforated to allow 4

Material easy drain-out or entrance of water when the tray is being lifted or lowered in the sterilizer. Handles shall be provided for handling the tray and the tray shall be convenient for fitting in or removal from the sterilizer. When the tray is loaded as given below, with load uniformly distributed, the lid shall close slowly and without bang. The tray shall be of such a design so as to take a total load of Large 40 N. the depth of tray shall be Min 25mm. Functional requirements A drain-out connection shall be provided to facilitate draining of the sterilizer when desired. The tap handle knob and lid operating handle shall be fitted with suitable grips of thermally insulating material. The metal parts under the grips shall be completely covered so as no to come in contact with the operator. Methods of operation of Sterilizer Sterilizers shall be capable of operation on the heat sources detailed in 8.2 to 8.4 as selected by the purchaser and shall satisfy the requirements specified therein. ly operated sterilizers shall have a single-phase, 3pin connection and the loading shall be large 1.5 kw An indicator lamp shall be provided on the sterilizer to indicate by glowing when the instrument is ON. The entire electrical circuit shall be insulated from the sterilizer and the leakage current shall be not more than 210µA or 300µA, when tested in accordance with IS 302: 1979. It shall also be capable of withstanding a high voltage test of 1000V for one minute between any point of supply and earth. The wires used shall be heat resistant and the wiring shall be neatly laid out. The minimum current carrying capacity of wire shall be 15A. Heating Element Heating element shall conform to IS 4159:1983. It shall be of easily replaceable type and fitted with either built-in ejector device or built in thermal cut out system. The heating element shall operate on up to a maximum voltage of 250v singlephase 50 Hz AC. Thermostat Thermostat shall be capable of ensuring boiling water at sea level with a differential of 5 C Finish All stainless steel parts shall be finished smooth and polished bright or strain finish reasonably free from wrinkles and bulges. The brass cock shall be plated chromium over nickel in accordance with service grade No. 2 of IS 4827: 1983 Marking Instruction manual The sterilizers shall be legibly and indelibly marked with the following: a. Identification mark of the manufacturer. b. Wattage, voltage, phase and cycle of electrically operated sterilizers, c. Not to be used in anaesthetizing sites, and d. Instrument does not give sterility Each sterilizer shall be accompanied by any instruction manual which shall contain information regarding instruction, directions and operation of the sterilizer and 5

Material Packing routine maintenance and service. It shall contain instruction to use soft water to minimize scaling. As agreed to between the purchaser and the supplier before awarding the contract. Schedule 8(ii) INSTRUMENT STERILIZER (SMALL) Material Design Dimensions The sterilizer shall consist of a seamless shell, having a hand-operated lid at the upper end. It shall be designed to operate on electricity, gas or kerosene (heat sources) either independently or in combination, as desired by the purchaser. The nominal inside dimensions of the shell shall be as given below, subject to a tolerance of ±2percent. 300 mm (L) X 150 mm(w) X 125 mm(h) The thickness of the stainless steel sheet used for shell, tray and lid shell be 0.90mm subject to the tolerances on thickness as specified in the relevant Indian standard. However, thickness of shell tray and lid shall not be less than 0.70mm at any place, after drawing and for handle lever, it shall be 3.00mm. the minimum thickness for handle link-connecting the handle lever and lid shall be 1.5mm. The shell shall be pressed to form a seamless container. The rim shall be so formed so as to prevent excessive steam escape. Provision shall be made at the bottom of the shell to place it properly on the table. The lid shall be made seamless, dished and shall be designed to prevent excessive steam escape and restrict the condensate within the shell, but in any case it shall not buckle, warp, or twist with load. The corners shall be rounded to suit those of the shell. The lid shall open fully (between 55 and 85 ) by single operation from its closed position. A provision shall be made to connect the link end of the handle mechanism for simultaneous opening and closing of the tray and lid. At the opening of the lid between 55 and 85 the tray shall be able to come to the top level of the shell. A mechanism connected to the lid shall be such that when the lid is open, a bracket or rest for instruments tray shall bring the seamless tray well out of the water even when the water is at the highest level. The tray bottom shall be perforated to allow easy drain-out or entrance of water when the tray is being lifted or lowered in the sterilizer. Handles shall be provided for handling the tray and the tray shall be convenient for fitting in or removal from the sterilizer. When the tray is loaded as given below, with load uniformly distributed, the lid shall close slowly and without bang. The tray shall be of such a design so as to take a total load of Large 40 N. the depth of tray shall be Min 25mm. Functional requirements A drain-out connection shall be provided to facilitate draining of the sterilizer when desired. The tap handle knob and lid operating handle shall be fitted with suitable grips of 6

Material Methods of operation of Sterilizer thermally insulating material. The metal parts under the grips shall be completely covered so as no to come in contact with the operator. Sterilizers shall be capable of operation on the heat sources detailed in 8.2 to 8.4 as selected by the purchaser and shall satisfy the requirements specified therein. ly operated sterilizers shall have a single-phase, 3pin connection and the loading shall be large 1.0 kw An indicator lamp shall be provided on the sterilizer to indicate by glowing when the instrument is ON. The entire electrical circuit shall be insulated from the sterilizer and the leakage current shall be not more than 210µA or 300µA, when tested in accordance with IS 302: 1979. It shall also be capable of withstanding a high voltage test of 1000V for one minute between any point of supply and earth. The wires used shall be heat resistant and the wiring shall be neatly laid out. The minimum current carrying capacity of wire shall be 15A. Heating Element Heating element shall conform to IS 4159:1983. It shall be of easily replaceable type and fitted with either built-in ejector device or built in thermal cut out system. The heating element shall operate on up to a maximum voltage of 250v singlephase 50 Hz AC. Thermostat Thermostat shall be capable of ensuring boiling water at sea level with a differential of 5 C Finish Marking Instruction manual All stainless steel parts shall be finished smooth and polished bright or strain finish reasonably free from wrinkles and bulges. The brass cock shall be plated chromium over nickel in accordance with service grade No. 2 of IS 4827: 1983 The sterilizers shall be legibly and indelibly marked with the following: e. Identification mark of the manufacturer. f. Wattage, voltage, phase and cycle of electrically operated sterilizers, g. Not to be used in anaesthetizing sites, and h. Instrument does not give sterility Each sterilizer shall be accompanied by any instruction manual which shall contain information regarding instruction, directions and operation of the sterilizer and routine maintenance and service. It shall contain instruction to use soft water to minimize scaling. Packing As agreed to between the purchaser and the supplier before awarding the contract. All other terms and conditions of the bid document remain unaltered. In case of any further information/clarification, they may contact UNOPS or WBMSC through e-mail at procurementinoc@unops.org or wbmsc@wbhealth.gov.in respectively; individual visits, in person, to UNOPS or WBMSC offices shall not be entertained. All requests for seeking clarification should cite the subject tender and should be received by the deadline indicated for the purpose, above. 7