BP MAINTENANCE WORK INSTRUCTIONS FREQUENTLY ASKED QUESTIONS

Similar documents
NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

This policy applies to all Hot Work jobs performed on the Calhoun mill property by AbitibiAbitibiBowater employees.

NJSP HMRU. Module 5 B HM Operations 1

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

Hot Work Permit. Can this job be avoided? Is there a safer alternative? Permit No.:

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

1.2 To ensure the safety of all persons working in or occupying a building where a hot work operation is performed.

WELDING, CUTTING, AND BRAZING SAFETY PROGRAM

Facilities and Estates. Hot Works: Standard Operating Procedure. Document Control Summary

To: All SAAS Accredited Certification Bodies Subject: Clarification to Emergency and Health & Safety Requirements in the SA8000 Standard

OH&S WORKPLACE ASSESSMENT INSPECTION CHECKLIST

Safe Operating Procedure

AGT 1 Confined Space. Authorised Gas Tester 1. Scienco Limited. Authorised Gas Tester 1 1

AS/NZS :2008

The Social Accountability International (SAI) Fire Safety Checklist

Electrical Management

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

OUTLINE FOR FIRE PREVENTION ACTIVITY

HOT WORK PERMIT PROCEDURES

HOT WORK SAFETY PROGRAM:

CONTRACTOR WHS HAZARD STANDARD LASER SAFETY EXTERNAL USE ONLY

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

CERTIFICATION SAFETY & BEYOND

Course outline: 442 Capstone G105A UEENEEG105A - Verify compliance and functionality of low voltage general electrical installations

Monitoring Flammable Vapors and Gases in Industrial Processes

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

T.ex Single Gas Detector VISA

Loss Prevention Standard

HeatExchangerSpares.com Ltd HRS Heat Exchangers Ltd HRS Hevac Ltd HRS Hevac Engineering Ltd HRS International Ltd HRS Investments Ltd

RK Combustible Gas Transmitter Operator s Manual

Fire Safety. A TUC guide for trade union activists

Portable Gas Detection Practice

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

THE FIRE SAFETY GUIDE FOR BUSINESS OWNERS

Plumbing, Heating & Gas Industry Course Information

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

Hot Work Program & Operational Guidelines. Environmental Health, Safety and Emergency Management (828)

safe and your operations compliant

Loss Prevention Standard

RK / RK Methane Detector Operator s Manual

Audit Mapping Document

Survey of electrical equipment installed in hazardous areas on tankers

John Jay College of Criminal Justice HOT WORK PERMIT STANDARD OPERATING PROCEDURES

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

IRceL CH4 Methane (CH 4

Compliance Guidance for non-technical managers

Electrical Safety Policy

Safety Systems Review Retail Guidance and specification Version

Fire Risk Assessment. Guidance Notes. Location details. Risk Rating. Assessors. General notes

Fire Policy. Fire Safety Order (2005) Dangerous Substances and Explosive Atmospheres Regulations (2002)

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

Are Your Kitchen Hood Filters Compliant?

Demolition Permit Application (Please print and complete ENTIRE form)

Your specialist partner for total electrical compliance. Electrical Testing

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Fire Safety Audit: Part B - Questionnaire (Questionnaire Devised By Mr.R.R.Nair) Yes No x

Smoke detection in hazardous areas:

RK/ RK Combustible Gas Detector Operator s Manual

POLICY STATEMENT: Policy Number: Section 600 Physical Plant. Date Adopted: May 7, Date(s) Revised: September 4, 2012

Baseline Data Required for AS

Fire Prevention Plan

DUST EXPLOSION CODES AND STANDARDS: Ensuring Regional Compliance and Global Consistency

DSEAR - Requirements

SAFETY EXCELLENCE AWARD 2014 TECHNICAL SUPPORT SAFETY SURVEY FORM FINAL EVALUATION

1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone

Safe working with flammable substances

EQUIPMENT SAFEGUARDING LG Rev 21 Feb 11 Including

INTERNATIONAL STANDARD

FIRE RISK ASSESSMENT Self Assessment

NZQA registered unit standard version 1 Page 1 of 5. Demonstrate knowledge of electrical installations in special situations

Safety standards relevant to Refrigeration, Air-Conditioning and Heat Pump equipment

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Chapter 12 HOT WORK OPERATIONS. Purpose:

Australian/New Zealand Standard

5.07 Air Replenishment Systems

PLANT RISK ASSESSMENT REPORT

Guide to Membership Assessments

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010

Fire Prevention Plan

MICROpeL 75 Combustible Gas Sensor Part Number: PM

QUALIFICATION, PRE-REQUISITES AND THE CERTIFICATION PROCESS FOR COMPETENCE CERTIFICATION SCHEMES

RK Multi Point Detector Operator s Manual

7 Hazard assessment 8 Worker participation 9 Hazard elimination and control

NZQA registered unit standard 5897 version 3 Page 1 of 5. Design electronic security intruder alarm systems

ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS (EEHA) TESTING STANDARD

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Workplace Health and Safety Hotel Induction Handbook

Alarm Signalling Equipment: Connection Requirements (Victoria) TAN 06. Technical Advisory Note. Version 1 October 2018

UNCONTROLLED IF PRINTED. Issued with the authority of the Chief Commissioner and General Manager of Scouts Australia NSW

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

Contractor Worksheet Underground Fires Major Hazard Standard

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

June 2017 (Updated 18 January 2018) Fire Safety Policy. Peter Webb, Project Manager Compliance First Choice Homes Oldham Limited

DIRECTIVE NO: D-B

Training, Assessment, Consultants for Hazardous & Industrial Areas

ATM DEVICE THEFT & ATM GAS ATTACKS:

RK-05 Combustible Gas Transmitter Operator s Manual

Design & Use of Ground Based Pumps Guidance Document

NECA. Standard for Electrical Safety in the Workplace

Transcription:

BP MAINTENANCE WORK INSTRUCTIONS FREQUENTLY ASKED QUESTIONS The following FAQ was last updated 30/3/2016. This material is guidance only. If any of the content contradicts with requirements within the specific BP authorised work instruction, BP procedures, or legislation then the work instruction, procedure, or legislative requirement shall override this document. EVERYONE HAS THE OBLIGATION AND AUTHORITY TO STOP UNSAFE WORK Q: What deems a person competent to monitor the gas detector after the person trained to MSAPMOHS217A - Gas test atmospheres has completed the Gas Test Checklist? A: This is documented within the Pre-requisites (page 3) of each Work Instruction for which gas testing is a requirement. It states Any person deemed responsible for monitoring a gas detector during the work shall, as a minimum, have received instruction from a person competent in the above course to inform them of the location of the gas detector for monitoring, the alarm settings of the unit, and what to do in the event of an alarm sounding. Q: Do contractors need to provide BP their gas testing qualifications? Some used to upload these to KRS. A: Unless told otherwise by BP Procurement (Kate Atkinson), contractors required to be accredited should continue to follow any contractor accreditation requirements. However, it should be noted that contractor accreditation requirements are separate to Control of Work requirements. Control of Work requirements with respect to gas testing competencies are detailed within the Pre-requisites (page 3) of each Work Instruction for which gas testing is required: Any person conducting gas testing in accordance with this work instruction shall have successfully completed MSAPMOHS217A - Gas test atmospheres Any person deemed responsible for monitoring a gas detector during the work shall, as a minimum, have received instruction from a person competent in the above course to inform them of the location of the gas detector for monitoring, the alarm settings of the unit, and what to do in the event of an alarm sounding. With respect to record keeping of the competencies in the Work Instruction, and any additional competencies such as gas testing that are required within the work instruction, the following Pre-requisite (page 3) exists in each Work Instruction: Persons performing the task shall be trained and competent in this procedure with training records kept by their employer and available for audit on request. The above clause will include requests for evidence of external gas testing qualifications where these are required within the Work Instructions. This is aligned with current practices where BP may ask for evidence of other competencies for work being conducted by contractors for BP (e.g. high risk licences, confined space entry, etc.). BP is planning to increase the verification of work being undertaken to provide assurance that contractors comply with requirements and are managing the risks, irrespective of whether the work is being undertaken under a WPCG Work Clearance, BP Work Instruction, or BP Work Permit.

Q: Can I use a battery operated hand tool that has a spark within it under WI-MT-003 Use of Battery Operated Hand Tools? A: A Hot Work Permit is required for all hot work that involves the use of or creation of flames, sparks or energy discharge inside hazardous areas. This type of work includes burning, welding, grinding, air arcing, soldering, open flame, stress relieving, preheating or any similar activity that creates an uncontrolled ignition source. A key word here is uncontrolled. Some hand tools may have the potential for sparks within it. These may be used under the work instruction (if not one of the examples listed above as requiring a permit). It is considered that equipment that creates sparks in an uncontrolled way, e.g. grinders and other similar tools, poses a higher risk of ignition (e.g. of any residual fuel in the area) and therefore must be authorised by a Hot Work Permit. The work instruction may only be used for spark potential activities. This type of work includes battery-powered equipment (not certified for use in classified hazardous areas) such as: electrical test equipment, cordless drills, inspection and survey tools, digital cameras, hand-held instruments. Note also this work instruction only applies to battery operated hand tools, and not to mains powered equipment or other plant that may be electrically powered. Due to the potential diversity of such equipment and the energy they may store or generate, at present these are also considered higher risk than battery operated hand tools. Hot Work Permits are required for mains powered equipment and any battery operated equipment that is not a hand tool. Q: What gases are the gas detectors testing for? A: As the gas testing associated with WI-MT-002 and 003 are with respect to the risk of a flammable atmospheres rather than for a particular atmospheric contaminant that may pose a health risk, the gas detectors will need to test for (as a minimum) LEL, and O2. These fields are required on the Gas Test Checklist that is required to be completed in support of the work instruction. If your company JSA/SWMS identifies other risks requiring testing, e.g. CO from exhaust emissions (if applicable) then this would be still required by your own risk assessment associated with the work. Such risks are considered Task Hazards and are outside the scope of the work instruction. As such they are not required on the Gas Test Checklist to ensure safe use of the equipment in the hazardous area with respect to site and process hazards.

Q: In regards to the training, does it need to be professional training? A: Training should be conducted in accordance with your BP Accredited company processes to ensure that it is implemented sustainably and to a level sufficient to ensure that personnel are competent in the work instructions. Verification by BP will be conducted to confirm personnel in the field are competent and compliant. Contractors should have their own existing verification/audit processes of their own work to ensure your own workers are competent and compliant in not just this but other requirements of both your own organisation, BP or local legislation. This should provide feedback as to whether training implemented is adequate. BP does not mandate that all training shall be conducted by a person with a Certificate IV in Training and Assessment, for example our Issuing Authority training is presently not. However, the specific gas testing training module is specified in the work instructions to which it is relevant (WI-MT-002 and 003) shall be conducted by a registered training organisation (RTO) approved to deliver this unit of competency. These can be found at http://training.gov.au/ Q: Do I still need a hot work permit? A: If you are trained and competent in the Work Instruction/s relevant to your work, and you comply with all the requirements including the scope, equipment, and controls (including gas detection and the associated recognised training prescribed) then you do not need a BP Hot Work Permit. A WPCG work clearance is still utilised to authorise the work and communicate it to the site representative. NOTE: If you are not using the work instruction, or you are not trained in it, or you want to vary some of the scope or controls required, then you need a Hot Work Permit for all Hot Work in the Hazardous area. Q: If I am experienced in the use of a gas detector, do I still need the training prescribed? A: Yes you do. This gives BP assurance of your level of competence. It is not practical or sustainable for BP to directly review every single contractor s experience, skills and competence. This nationally recognised training provides BP assurance, and gives you and your organisation the same level of assurance of your competency and the quality of training provided to you. As it is nationally recognised, it is also typically transferrable to other work for other organisations that you may service.

Q: Do I still need a Ground Disturbance Certificate or a Ground Disturbance Checklist? A: You do not need a Ground Disturbance Certificate or a Ground Disturbance Checklist IF you are trained and competent in the Work Instruction WI-MT-004, and comply with all the requirements including scope, equipment and training. A Ground Disturbance Certificate or a Ground Disturbance Checklist remains required for non-routine tasks and any other tasks not within the scope of WI-MT-004, or if you wish to deviate from any requirements of WI-MT-004, or if you are not trained in the work instruction. Note if you are using battery operated equipment within the hazardous zone to drill into concrete or use of a battery operated service locator under WI-MT-004 then you also need to use WI-MT-003 and comply with all requirements including the external gas testing qualifications. Q: Why don t I need a permit of certificate for this work anymore? A: Permits are for non-routine work, or work that is not considered low risk. A separate stream of work (low risk routine work) may be controlled with a documented risk assessed procedure authorised by BP (i.e. a BP Work Instruction). BP has now authorised the use of some work instructions for specific routine maintenance and construction tasks that have been assessed as low risk if the controls required within the work instruction are implemented, and the person is trained in the work instruction. Within these work instructions the WPCG work clearance remains as the method to communicate to the site representative and have them authorise the work at the work site. A specific task may still be escalated to a Work Permit or Certificate if it is deemed necessary to safely control the work. EVERYONE HAS THE OBLIGATION AND AUTHORITY TO STOP UNSAFE WORK Q: There is no cross reference from the Gas Test Checklist to my JSA. Why not? A: The existing WPCG Work Clearance Form must reference the contractor JSA, the work instruction and the job number. The Gas Test Checklist also requires the Job No. to cross reference to the WPCG form as the WPCG form itself does not have a number. Referencing a WPCG form number would possibly have been better but that does not exist. This way there is an auditable trail between the Gas Test Checklist and the WPCG Form (via the Job No.); and direct cross referencing on the WPCG form of both the work instruction and the JSA. Through this, all these documents (WPCG form, work instructions, JSAs, and Gas Test Checklist) have an auditable trail to cross reference between each other.

Q: With regard to the new Retail Work Instruction Use of Battery Operated Hand Tools in Hazardous Zone, it says that one of the pre-requisites is that the person carrying out these works must have successfully completed MSAPMOHS217A. We have already completed RIIWHS202D which includes a component on using a gas detector, and have also done BA training with Fire and Rescue, are we able to carry out works under this new Work Instruction without doing the MSA module? A: No. You must complete MSAPMOHS217A as specified. The BA and Rescue training is not relevant to gas testing. Also, the RII Confined Space Course, whilst a nationally recognised unit of competency, is significantly different with respect to training in gas testing. Elements and Performance Criteria for each unit: RIIWHS202D - Enter and work in confined spaces only lists the following relevant element: 2.2 Ensure that the atmosphere is tested and monitored for harmful elements MSAPMOHS217A - Gas test atmospheres requires 1. Prepare for gas testing. 1.1 Determine type of gas/atmosphere to be tested. 1.2 Select and calibrate equipment in accordance with procedures. 1.3 Determine gas testing regime/sampling pattern required. 1.4 Identify hazards from possible atmosphere contaminants. 1.5 Implement hazard control measures, including use of appropriate personal protective equipment. 2. Test gas. 2.1 Use gas testing equipment to test gas as required. 2.2 Interpret and report readings. 2.3 Monitor gas on an ongoing basis as required. 2.4 Take required action(s) if readings are unacceptable. 3. Maintain equipment. 3.1 Clean and maintain gas testing equipment in accordance with procedures. 3.2 Inspect and fault find monitoring equipment in accordance with procedures. 3.3 Return gas testing equipment to required location and in required condition. 3.4 Maintain records of tests and results in accordance with procedures.

Q: Does WI-MT-002 Entry of Mobile Plant into Hazardous Areas include the use of generators? A: No. Mobile Plant covered by this Work Instructions, does not include portable equipment such as generators. (Powered) Mobile Plant is defined in the Model WHS regulations, Victorian OHS regulations, and in a bulletin from the WA regulator (in lieu of no definition in their regulations). This is as follows: powered mobile plant means plant that is provided with some form of self-propulsion that is ordinarily under the direct control of an operator. The intent of not including all other plant in this work instruction is: Addressing efficiencies of the highest frequency, low risk routine maintenance activities as the highest priority. The ability to quickly turn off the ignition source as there is an operator situated at the controls when in operation (unlike some other equipment like a generator which may be nearby but not within arm s reach). Hierarchy of control: maintain the current incentive to locate this equipment outside the hazardous area under the lower requirements associated with a typical WPCG work clearance. This eliminates the ignition source from the hazardous area. Q: What gas detectors does BP require? A: BP does not mandate a particular make and model of gas detector. To be used to conduct the gas testing associated with completion of the Gas Test Checklist is does need to be rated for the hazardous area in which it will be used, within current calibration and bump tested prior to use. AS/NZS 60079.29.2:2008 Explosive atmospheres Part 29.2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen is available to support your selection decision. BP presently supplies BP employee Issuing Authorities with the Impact Pro, manufactured by Honeywell and supplied locally through ThermoFisher. If you are considering purchasing (or hiring) your own gas detectors here are some points to consider, other than the obvious things to check like hazardous area rating, alarms (visible and audible), and gas sensors in the unit: If you are considering purchasing (or hiring) your own gas detectors here are some points to consider, other than the obvious things to check like hazardous area rating, alarms (visible and audible), and gas sensors in the unit: What calibration gas do you require? The Impact Pro has an advantage here over most models as you can calibrate for LEL on methane and then change the calibration curve electronically to octane (typically representative of petrol). On most models you should choose a calibration gas bottle with a gas with similar LEL calibration curve to the materials you wish to detect. This may be something like Pentane or Hexane which have similar curves to Octane but are less readily available and likely higher cost in comparison to methane. Methane (typically used) may not be representative without using correction factors. The recently issued BP Work Instructions require 0% LEL. This provides greater assurance to BP in the event contractors calibrate a unit other than the Impact Pro with methane. When calibrated on methane the unit may read low (by a factor typically between 1.5 and 3) if testing for presence of petrol vapour (e.g. octane). We have not mandated in the Work Instructions with which gas the unit has been calibrated or the use of correction factors on readings calibrated with methane (i.e. 0%LEL x 3 is still 0%LEL). Does it have a pump or ability to affix one? This is not mandatory for the Work Instructions but would be needed for use with the initial issue of BP Work Permits at

times to test in vessels, pits and drains prior to BP authorised Issuing Authorities issuing a Hot Work Permit or Confined Space Entry Permit. Or is it a passive unit than has no such pump capability? How rugged is the unit? Impact Pro has shown it can withstand a lot. Impact Pros have lasted over 10 years. Many cheaper units may only last a couple of years. Weight. They can vary. Impact Pro is mid-range. Others are significantly heavier, some a smaller and much lighter. Servicing. Can you readily service yourself to change sensors when required by the manufacturer? Again, an advantage it seems for Impact Pro where it has a design that enables you to change the sensor cartridge more readily if you wish to do it yourself. Most other units would need to be sent back causing some delays and additional costs (possibly even the purchase of spare units to cover whilst the others are being serviced). How easy is it to calibrate? (calibrate, not just bump test) What support do you get to be shown how to do this? Or do you need to send it away to be calibrated every 6 months? At what cost? Again, does this mean you would need to buy an additional unit to use during the period you have sent it away? How long do sensors last? Often common duration across different models, but may vary. Parts can be expensive and supply can be slow. Some units you simply buy a new one when sensors expire rather than incur a similar cost for sensor replacement and calibration. Can you bump test to confirm operation prior to use? This is required by the Gas Test Checklists associated with BP Work Instructions, and Gas Test Certificates associated with BP Hot Work Permits and BP Confined Space Permits. It is strong recommended by AS/NZS 60079.29.2:2008 Explosive atmospheres Part 29.2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen. If it can be calibrated, but cannot be bump tested, this type of instrument may be what AS600079.29.2:2008 refers to as a Small, hand-held apparatus that may be used for leak-detection or spot checks, rather than for use in a multi-role mode so as to include leak detection, spot checking and local area monitoring functions. If they are unable to comply with the BP requirement to be bump tested they cannot be utilised to perform testing associated with BP Gas Test Checklists or Gas Test Certificates. If you can t bump test or calibrate it then it may fundamentally be a personal monitor rather than gas detector. Some of these you just turn on and it lasts for a year or two without verification of accuracy other than a self-diagnostics without gas injection. Some units such as those worn for H2S in some industries (like Bitumen plants) are like this but these are typically not used to gas test the area prior to work, but are supplementary confirmation of safe levels of exposure at the worker breathing zone. Such instruments cannot be utilised to perform testing associated with BP Gas Test Checklists or Gas Test Certificates.