Sensero-868/915 AC, Sensero-868/915 AC Plus Nr , , ,

Similar documents
BiSens SWR-230V. Installation instructions (translation) Safety instructions. Safety instructions for radio operation

External Wireless Sounder

External Wireless Sounder

TDS 20 R / TDS 30 R / TDS 50 R

Product and Applications Description

Application description

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

User Manual 120/240/300 Outdoor Motion Detector

Operator systems for garage doors Highline 10, 15, 18

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

TCH 2000 E OPERATING MANUAL DESIGNER GLASS CONVECTOR TRT-BA-TCH2000E-TC-001-EN

KNX WS1000 Style. Building Control System. Installation and Operation

EXTERNAL VENETIAN BLIND

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating Instructions!

compact office 24V compact office 24V Lux

Operating instructions

Bosch Smart Home. Motion Detector Instruction Manual

Dohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG

Combivac Operating Instructions Combivac

PresenceLight 180 PresenceLight 360

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Remote alarm unit Art. Nr.:

ST 53.1 User s manual

Consultant Specification AGILE Wireless Fire Detection System

Operation and Maintenance Manual

Alarm System SECURE AS 302

ROBERTS. FM / MW dual alarm clock radio with instant time set. Please read this manual before use

Dusk to Dawn Sensor. Instruction Manual. Connect Series. Model No. JSJSLW801. Version 2

Protégé Eclipse LED Keypad User Manual PRT-KLES

EasyStart Select. Visit for more technical information and downloads. Eberspächer parking heaters

Installation Instructions

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Installation instructions

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren

1 Safety instructions. 2 Device components. Observer 220. Art.-No.: W 220 WW. Operationsmanual

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

Radio fire warning panel SRC 3000

Owners manual animeo Solo

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Radio Frequency Do s & Don ts

TDS 100. EN Operating Manual Electrical Fan Heater

Instructions For Use ENG. LED Magnifier Lamp

TTV 4500 / TTV 4500 HP / TTV 7000

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

Mounting instructions Genius Radio

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

Wind Alarm Instrument

Heart Rate Monitor MODEL: SE128 USER MANUAL

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

Installer: (Name, address, telephone number)

EN Z Subject to change due to technical improvements! Operating instructions

Electronic controllers. Comfort embellishes everyday life

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

CO2 Gas Warning System Assembly and Operating Instructions

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

Long Range Radio Alarm Transmitter

Data sheet. Function description. Benefits

programmable control model installation and setup guide M /11/ Hunter Fan Company

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

INSTRUCTION MANUAL PC255O

WIRELESS THERMO-HYGROMETER Instructions manual Cat. No. WS9070IT+

Weather Station Wetterstation

Original operating instructions Safety switch with guard locking AC901S AC902S

Installer: (Name, address, telephone number)

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Bosch Smart Home. Motion Detector Instruction Manual

Translation of the assembly instructions with operating instructions and technical appendix

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Tubular motor with encoder for awnings series EUROPLUS

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

compact office 24V compact office 24V Lux

User's Manual. and Warranty Information. ThyssenKrupp. ThyssenKrupp Access

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

FlowJam Bulk Flow Detection

Vacu-Mixer. Operating Instructions

Campers Alert TM Portable System Hunters Alert TM Portable System

Operating Manual SEVi 160 Series

FW-KP WIRELESS KEYPAD

Remote control Installation and operating guide

FAZ 3000-DCF DCF module

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Installer: (Name, address, telephone)

Safety. Detection. Control. SAFETY INTERFACES. Safety Interfaces and Relays. Product catalogue. Issue 1

5 On/Off button 6 Function selector switch 7 Symbol - Eco function 8 Symbol - Standard heating function

Long Range Radio Alarm Transmitter

INSTRUCTION MANUAL PC255O

Home Doorway Alert Kit

TECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.

MANUAL Oil Level Sensor

Transcription:

Sensero-868/915 AC, Sensero-868/915 AC Plus Nr. 28890.0001, 28900.0001, 28890.0901, 28900.0901 Installation instructions (translation) Safety instructions light sensor rain sensor light sensor The instructions must be observed in order to ensure the product can be operated smoothly and safely and its properties can be fully realised. EN wind sensor Underside of the device wind sensor The operator/user must have completely read and understood the instructions. The operator must ensure that the operating instructions are made available to the user in a legible form. The operator must ensure that all safety measures are observed and met. The following safety and assembly instructions apply to the device and not to the accessories and drive. wind potentiometer Failure to observe these can cause physical injury! rain potentiometer Observe all safety instructions! Never install or take into operation devices which are damaged. Only use unmodifi ed and compatible original parts. If the device is opened without permission or used in an improper manner, or if it is incorrectly installed or operated, there is a risk of damage to persons and property. The device contains small parts which can be swallowed. DOWN button STOP button UP button wind sensor alarm-led light LED operating-led light potentiometer twilight potentiometer The Sensero AC is a sun/twilight and wind sensor for sun protection systems. The Sensero AC Plus additionally has a rain sensor. Signal transmission between the Sensero and the receiver is via a radio link. The device will only work in connection with compatible radio receivers from the range of the elero radio system. Manual operation of the system is carried out with a handheld/wall transmitter. This item is not included in the scope of delivery. Transport Should you receive the device in a damaged condition despite proper packaging, you must not put it into operation. Complain about the damage to the transport company immediately. Installation Observe the regulations during installation. The device may only be used by persons who have read and understood the instructions. Operation If transmitters are used for controlling the system, its operating range must stay visible during operation. Keep control systems out of the reach of children and the disabled. Safety instructions for radio operation Observe all safety instructions for radio operation! Only use radio systems which are approved and can be operated without interference. The radio systems must not be operated in areas where there is a heightened risk of interference (e.g. hospitals, airports). The remote control is only approved for devices and systems for which any malfunction of the transmitter or receiver would not result in a risk for persons, animals or property, or if such a risk is covered by other safety equipment. elero GmbH Antriebstechnik Linsenhofer Straße 59-63 D-72660 Beuren Fon: +49 7025 13-01 Fax: +49 7025 13-212 info@elero.de www.elero.com 181109303_EN_0712 We reserve the right to make technical changes

Intended use The operator has no protection whatsoever from interferences by other telecommunication installations and local terminals (e.g. also from radio installations) that are normally used on the same frequency range. The range of the radio signal is limited by statutory regulations and the structural conditions. Only use radio receivers with equipment and units approved by the manufacturer. Using a number of receivers may cause interference. Therefore, maintain a minimum distance of 15 cm between the receivers. Before installing the unit at the specified position, check the proper function of the device and the receiver. Intended use The device must only be used to control awnings, venetian blinds and roller shutters. Third-party devices should only be connected after consultation with your specialised dealer. Other use, or use beyond this is not considered to be use for intended purpose. Exclusion of liability elero GmbH assumes no liability for personal injuries, property damage and fi nancial losses which arise from modifi cations to the device, improper use and a failure to observe the instructions. Liability for material defects is excluded in such cases. Definition of terms In these instructions, the term "device" is used to describe the Sensero. For "down" or "closed" (closing, moving down etc.), "Down" is used; for "up" or "open" (opening, retraction etc.), "Up" is used in accordance with the designation of the buttons. Scope of supply Sensero, 1 wall bracket, 3 dowels, 5 screws, 1 nut Accessories Corner or mast support: Item Number 242690202v Electrical connection WARNING! Risk of injury due to electrocution! Connections must be performed by an authorised specialist! 1. Switch off the mains voltage. 2. Connect the cables of the device according to colour: blue = N black = L 3. Switch on the mains voltage. The green operating LED indicates readiness for operation. Mounting NOTICE! Caution - Very Hot! Risk of burns if touched! The rain sensor is hot when operating! Do not touch the rain sensor! There are several options for mounting. CAUTION! Downwinds on the façade can lead to destruction of the device! The device is not able to detect these winds. Do not mount the device under a jutty. For correct wind measurement, mount the device at the façade in a position that allows it to catch all wind directions. After mounting, remove the red cover cap from the wind sensor. Technical data Operating voltage 230 V/50 Hz Temperature range -20 C to +60 C IP Code IP 44 Radio frequency 868 MHz frequency band Standby consumption 2 W (Sensero AC) 2 to 7 W (Sensero AC Plus) Weight 630 g Dimensions L 205 x W 125 x H 105 mm Wall bracket The device can be fastened to the upper side of the roof or to the façade using the tilting wall bracket. For USA, Canada, Australia, and some South American countries, the following values apply: Radio frequency 915 MHz frequency band EN 2 elero GmbH

Setting the mode (awning, protection against prying eyes, roller shutter) Awning mode Twilight function is switched off. (Twilight potentiometer is on Off) The awning will be retracted automatically when the current sensor measured value changes from 1 to 0 (late in the evening) or when the current light sensor measured value changes from 0 to 1 (early in the morning). Mast support As an alternative, mount the device to a mast of 27 mm diameter. Corner or mast support Use the corner or mast support to attach the device to the corner of the façade or to the mast. Protection against prying eyes mode The light threshold value must be set to 2 or higher. To keep the blind closed even in the evening, close the blind manually using a hand-held transmitter or an elero timer. The current transitions of the light sensor measured values from 1 to 0 (late in the evening) or from 0 to 1 (early in the morning) will be ignored. The blind will remain closed throughout the night. The travel commands such as tilting position (venetian blind) or ventilation position (roller shutter) will be executed automatically the next day. Roller shutter mode The light threshold value must be set to 2 or higher. Setting the mode (awning, protection against prying eyes, roller shutter) The device can be operated in three different modes. You can select the modes as follows: 1. Turn the wind potentiometer to Function. 2. Keep the UP and DOWN buttons pressed for at least 3 seconds. Press the two buttons until the device is in the desired mode. The fl ashing alarm LED indicates the mode of the device: Red alarm LED fl ashes once Awning mode Red alarm LED fl ashes twice Protection against prying eyes mode Red alarm LED fl ashes 3x Roller shutter mode The set mode is displayed at each radio transmission by the fl ashing of the operating LED (LED fl ashing signal 1x per minute). Turn the rotary potentiometer from Function back to a value selected by you. The awning mode is set as standard in the delivery condition. OEM versions may also be set to a different mode. Wind commands are executed in every mode. The wind interlock is active for 15 to 17 minutes. Support for the roller shutter mode is dependent on the software version of the receiver. If the roller shutter is driven manually by a timer or the twilight function to the lower end position, the light function (driving according to set light value) will be switched off. The current transitions of the light sensor measured values from 1 to 0 (late in the evening) or from 0 to 1 (early in the morning) will be ignored. You can switch on the light function again in several different ways: by means of a manual UP travel command to the upper end position by means of an automatic timer command to the upper end position by using the hand-held transmitter to switch from AUTOMATIC mode to MANUAL mode and back to AUTOMATIC mode. Programming the device The end positions of the drive have been set. One transmitter has been programmed. 1. Move the blind to the centre position. 2. Press and hold the UP/DOWN and P buttons on the handheld/wall transmitter simultaneously for at least 3 seconds. The blind moves up and down for 2 minutes. 3. Press the UP button at the device immediately after the start of upward travel. The drive will stop briefl y. 4. Press the DOWN button at the device immediately after the start of downward travel. The drive will stop. You have successfully programmed the device. elero GmbH EN 3

Programming the device Symbols at the device LED flash signals Alarm LED (red) Light LED (yellow) Operating LED (green) Wind Rain Twilight DOWN button UP button STOP /button Light LED (yellow) shines Light LED (yellow) flashes constantly Alarm LED (red) shines Alarm LED (red) flashes constantly Operating LED (green) goes out once Operating LED (green) goes out twice Operating LED (green) goes out 3x All LEDs flash Light value reached or exceeded, or twilight value reached or undercut Flashes for the duration of the delay time: light value undercut Measured wind value or rain value reached or exceeded Delay time. Wind value or rain value undercut Device transmits in awning mode Device transmits in protection against prying eyes mode Device transmits in roller shutter mode A sensor is defective or wet Setting the threshold values There are rotary potentiometers at the underside of the device. You can set the threshold values in steps using the rotary potentiometers. Light OFF Level 1 Settings 2 to 14 Level 7 Level 15 The light function is switched off Travel down at a low light level Intermediate levels Factory setting Travel down at a high light level Light function The light intensity is measured by the integrated light sensor and compared to the threshold value. The blind is raised. Wind Rain Level 1 Settings 2 to 10 Level 4 Level 11 OFF Level 1 Settings 3 to 14 Level 15 Level 2 Travel up at low wind speed Intermediate levels Factory setting Travel up at high wind speeds The rain function is switched off Travel up at a low rain level Intermediate levels Travel up at a high rain level Factory setting (Sensero Plus) min. 5-7 min. Twilight OFF Level 1 Settings 2 to 13 Level 14 The twilight function is switched off Factory setting Travel down at darkness Intermediate levels Travel down at start of twilight The factory settings for OEM devices may differ from the above. The sun shines on the sensor for no less than 5 to 7 minutes. The measured light value reaches or exceeds the set threshold value. The yellow light LED lights up. After a short delay (5 to 7 minutes), the blind will travel down. The weather situation is changing. The measured light value falls below the set threshold value. EN 4 elero GmbH

Programming the device After a delay of 15 to 17 minutes, the blind will travel up. The yellow light LED fl ashes during the delay time. Use the HAND/AUTO switching function at the programmed hand-held/wall transmitter to enable or disable the light function. Checking the light function (test mode) The blind is raised. In the test mode the delay times are shortened from minutes to seconds. In this way, the travel movements of the system can be tested when the set threshold value is exceeded or undercut. 1. Press and hold the UP button for at least 3 seconds until the green operating LED fl ashes. WARNING! Risk of injury by downwards travel of awning, roller shutter, or venetian blind! The test mode is active for 5 minutes. This time cannot be shortened. Keep away from the operating range of the system. 2. Shine a torch on the light sensor. A) The set light value is reached or exceeded. B) Less light. The set light value is now undercut. The yellow light LED shines. The blind travels down immediately. The yellow light LED flashes and goes out after 15 seconds. The blind travels up after 15 seconds. You can repeat the operation as often as you want within 5 minutes. Wind function The wind speed is measured by the integrated wind sensor and compared to the threshold value. The wind signal is an emergency signal, hence the wind function is always active. The blind is retraced. The measured wind value exceeds the set threshold value; the wind signal is triggered. Blocked for 15 to 17 min. The blind moves up and remains raised for a minimum of 15 to 17 minutes. Red alarm LED shines. The travel keys at the device are blocked. The red alarm LED fl ashes during the delay time. As long as the system is blocked, it is not possible to move the blind down via a hand-held transmitter. The block will be cancelled after the actual wind value has undercut the threshold for 15 to 17 minutes. Checking the wind function (test mode) The blind is raised. In the test mode the delay times are shortened from minutes to seconds. In this way, the travel movements of the system can be tested when the set threshold value is exceeded or undercut. 1. Press and hold the UP button for at least 3 seconds until the green operating LED fl ashes. WARNING! Risk of injury by downwards travel of awning, roller shutter, or venetian blind! The test mode is active for 5 minutes. This time cannot be shortened. Keep away from the operating range of the system. 2. Use the hand-held transmitter to bring the blind to the centre position. 3. Blow on the wind sensor. A) The set wind value is reached or exceeded. B) Blow with less force. The set wind value is now undercut. Red alarm LED shines. The blind travels up immediately. The red alarm LED fl ashes for 15 seconds. You can repeat the operation as often as you want within 5 minutes. Rain function The integrated rain sensor in the Sensero AC Plus measures the rain volume and compares it to the threshold value. elero GmbH EN 5

Maintenance CAUTION! Caution - Very Hot! Risk of burns if touched! The rain sensor is hot when operating! Do not touch the rain sensor! The blind is retraced. The measured rain value exceeds the set threshold value. 2. Use the hand-held transmitter to bring the blind to the centre position. 3. Moisten the rain sensor. The set rain value is reached or exceeded. Stop moistening the rain sensor. The set rain value is now undercut. Red alarm LED shines. The blind travels up immediately. The red alarm LED fl ashes for 15 seconds. You can repeat the operation as often as you want within 5 minutes. Deleting a programmed sensor (Not possible in the Function position). Press the UP and DOWN buttons simultaneously for at least 3 seconds. The green operating LED goes out briefl y. The device is now deleted from all receivers within range. Maintenance The device must be freely accessible and must not be overgrown by vegetation. The device is maintenance-free, however the cover must be cleaned from time to time using a moist cloth. 15-17 min. sensor drying phase The blind moves up and remains raised for 15 to 17 minutes. Red alarm LED lights steadily. The travel keys at the device are blocked. The red alarm LED fl ashes during the delay time. After 15 to 17 minutes, the drive may be retracted via the automatic transmitter. Retracting via the hand-held transmitter is possible at any time. If the blind was retracted via a transmitter within the blocked period (15 to 17 minutes), automatic raising of the system in case of rain will be possible at the earliest one hour after retraction. Checking the rain function (test mode) Only available with AC Plus. The blind is retraced. In the test mode the delay times are shortened from minutes to seconds. In this way, the travel movements of the system can be tested when the set threshold value is exceeded or undercut. 1. Press and hold the UP button for at least 3 seconds until the green operating LED fl ashes. WARNING! Risk of injury by downwards travel of awning, roller shutter, or venetian blind! The test mode is active for 5 minutes. This time cannot be shortened. Keep away from the operating range of the system. Disposal CAUTION! Caution - Very Hot! Risk of burns if touched! The rain sensor is hot when operating! Do not touch the rain sensor! After fi nal utilisation, dispose of the device pursuant to the applicable regulations. Troubleshooting Fault Cause Remedy The blind travels up automatically in manual mode No travel command can be issued via the hand-held transmitter The blind does not travel up when it is windy. The wind or rain alarm is active. The rain sensor is dirty. Poor radio connection Voltage supply is interrupted. The wind alarm is active. The batteries in the handheld transmitter are flat. Motor has no power supply or is overheated WIND threshold value is set incorrectly Wait until the delay time has elapsed (15 minutes). Clean the rain sensor. Change the position of the device. Check the voltage. Wait until the delay time has elapsed (15 minutes). Change battery Check power supply or allow motor to cool down. Adjust the WIND threshold value. EN 6 elero GmbH

Repair Fault Cause Remedy The blind doesn t travel down in response to sunshine The device cannot be programmed to recognize the receiver The blind doesn t travel down in response to darkness The blind travels down when it is windy. All LEDs fl ash The LIGHT threshold value is not exceeded. Wind alarm is active Rain alarm is active Roller shutter mode is not supported by the receiver. The transmitter is set to MANUAL mode. Poor radio connection Light sensor is dirty Device is already programmed Poor radio connection The twilight threshold value is set incorrectly. The twilight function is not supported by the receiver. Device is improperly programmed Wind sensor is wet; device is defective Adjust the LIGHT threshold value Wait until the delay time has elapsed (15 minutes). Wait until the delay time has elapsed (15 minutes). Change the mode Set the transmitter to AUTOMATIC mode. Change the position of the device. Clean light sensor Delete the device and re-program it Change the position of the device. Adjust the twilight threshold value. Use a different receiver. Delete the device and re-program it Allow the wind sensor to dry Repair Please contact your dealer if you have any queries. elero GmbH EN 7

EC Declaration of conformity EC-DECLARATION OF CONFORMITY We hereby declare that the following mentioned product/s meet/s the standards of the European Community. Product designation: ProLine 2 Lumo-868 all versions Lumero-868 / -915 all versions Aero-868 / -915, Aero-868 / -915 Plus, Aero-868 / -915 AC all versions Sensero-868 / -915 AC, Sensero-868 / -915 AC Plus all versions Description: Sun, dusk, wind and rain sensors with bidirectional and unidirectional radio-based sensor system. Can be used in conjunction with controllers for opening and closing roller shutter and other shading systems as well as other actuators. The conformity of the above mentioned products with the relevant health and safety requirements is taken into account by the following directives and standards: EMC Directive 2004/108/EC EN 61000-6-2:2005, EN 61000-6-3:2001 EN 60730-1:2000, EN 60730-2-7:1991 Low Voltage Directive 2006/95/EC EN 60335-1:2002 R&TTE Directives 1999/5/EC ETSI EN 301 489-3 V1.4.1 ETSI EN 300 220-2 V2.1.2 RoHS Directive 2002/95/EC Beuren, 05.07.2012 Ralph Trost -CE Manager-, -Representative documentation - www.elero.com