High Capacity Instantaneous Steam Fired Water Heater

Similar documents
Packaged Semi-Instantaneous Steam Fired Water Heater

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

Semi-Instantaneous Indirect Fired Water Heater

Packaged Steam Fired Water Heater

ASME Packaged Indirect Fired Water Heater

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

Light Duty Commercial Electric Water Heater

Indirect Fired Water Heater

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

Shipboard Electric Water Heater

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

FFH Series. Steam Fired Instantaneous Feed Forward Water Heaters

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

ASME Packaged Electric Water Heater

Shipboard Electric Water Heater

Shipboard Electric Water Heater

Tankless On Demand Electric Water Heater

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

Tepid Water Delivery System

ASME and Non-ASME Storage Vessels

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

SECTION DOMESTIC WATER HEATERS

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

DI/RO GAS TANKLESS WATER HEATER

Heat Pump Water Heater

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Commercial Semi-Instantaneous Water Heaters

Flo-Rite-Temp Instantaneous Steam/Water Heater

University of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL

THERMOSTATIC STEAM TRAPS

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

SB Series Brazed Plate Heat Exchanger Installation Manual

SECTION WATER HEATERS

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Flo-Rite-Temp Instantaneous Steam/Water Heater

THE THERMOSTATIC STEAM TRAP

SECTION HEATING BOILERS

SECTION PLUMBING EQUIPMENT

.005 ATMOSPHERIC DEAERATOR

ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

DEAERATORS .005 ATMOSPHERIC DEAERATOR

Water Heaters. Solar Applications

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS. ...world leaders in heat transfer technology

OPERATING AND MAINTENANCE MANUAL FOR BOILER WATER OR HIGH TEMPERATURE HOT WATER (HTHW) POWERED WATER HEATER

Design and Construction Standards SECTION PLUMBING EQUIPMENT

SPH Series. Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters CEMLINE CORPORATION

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

Heat Transfer Packages

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Deaerator. Specifications

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Domestic Pump Condensate Transfer Equipment

University of Delaware

SWH Series. STONESTEEL Packaged Copper Coil Water Heaters Steam/Boiler Water/High Temperature Hot Water Vertical or Horizontal

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source

DIVISION FINNED WATER-TUBE WATER HEATERS

Hydronic Product & Application Catalog

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

EZ Plate Instantaneous

WATER-TUBE POOL HEATERS

HEATING- Heating Accessories RW List Prices Page X - 1. Bronze B&G Circulator Pumps. Iron Body Red Fox B&G Circulator Pump

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

96% COMMERCIAL INDUSTRIAL HEATER. Condensing Gas Water Heating System. Thermal Efficiency

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Silhouette. Feedwater Heater. Boiler Feedwater

THE HARD WATER WATER HEATER

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

WATER-TUBE POOL HEATERS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

OPERATING AND MAINTENANCE MANUAL FOR STEAM FIRED WATER HEATER. ELECTRIC HEATER COMPANY BASE MODEL ST and STH

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Flo-Rite-Temp Installation and Operation Manual IOM-780-N

HEATING- Heating Accessories RW List Prices Page X - 1. Iron Body Red Fox B&G Circulator Pump. Bronze B&G Circulator Pumps

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

.03 ATMOSPHERIC DEAERATOR

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Installation, Operation and Maintenance

INSTANT-FLOW C-MICRO WATER HEATER

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR POINT OF USE STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL PS

DIVISION FINNED WATER-TUBE BOILERS

Transcription:

MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and money during installation All steam operating controls are factory selected, sized and piped Ready for water and steam service connections Heavy Duty Construction On demand water heater eliminates the need for a large storage tank Advanced design requires only 7 Sq.Ft. of floor space All steam controls are located within the steel frame Heat exchanger is ASME Section VIII stamped and registered with the National Board Factory fitted protective shroud covers the heat exchanger for improved safety High Efficiency Helical coil design is up to 40% more efficient than traditional U tube coils No standby heat loss Feed forward blending valve controls hot water to ± 4oF Applications Hotels Office Buildings Hospitals Wash Down Systems Model F Industrial Facilities Laundries Schools The space saving highly efficient F Model instantaneous steam fired water heater. ASME U ASME UM Highly Efficient and Compact Water Heater The Hubbell F Model is a compact, highly efficient, packaged instantaneous steam fired water heater perfect for new or replacement water heating requirements. This highly efficient Hubbell heater requires no large storage tank, is easily installed and requires minimal floor space. Furthermore, the Hubbell F model utilizes a helical coil as its source for heat transfer and is up to 40% more efficient than traditional U tube heaters. When you specify and install a Hubbell steam fired water heater, you will have confidence in knowing the owner will be provided with a long lasting, trouble-free source for hot water. On-Demand Heater Supplies Unlimited Hot Water

Spiral Design Heat Exchanger The heart of the Hubbell Instantaneous Steam fired water heater is a compact, highly efficient and versatile spiral tube heating coil which offers many advantages over a conventional "U" tube design including: No baffles. ASME Section VIII UM standard. Variety of materials available to suit specific applications. 100% counterflow for heat-transfer rates up to 40% greater than equivalent straight tube exchangers. Pressure drop is minimized. Bourdon tube configuration that allows entire assembly to expand and contract without localized stresses. Failure from thermal shock or mechanical process is rare. Compact design for easy maintenance. Parts in stock to prevent long and expensive down times. Blending Valve The temperature regulating device in a Hubbell Instantaneous Steam water heater is a feed forward blending valve designed to assure safe and accurate temperature control of the heated water for an entire range of flow capacities. A purely mechanical operation, the Hubbell blending valve will provide ± 4 o F temperature control without the use of thermostatic sensing devices. Pressure Sensing Line Temperature Control Rod Proportioning Plug With Safety Port How the blending valve works: 1. The proportioning valve plug is constructed from Hastelloy C and is regulated by movement of the neoprene diaphragm, induced by pressure differentials in the sensing head. 2. A sensing line loads the top portion of the diaphragm with supply line cold water pressure while blended water outlet pressure is being sensed below. 3. Flow demand imparts a pressure imbalance above (+) and below (-) the diaphragm resulting in movement of the diaphragm and proportioning plug. 4. The movement aligns ports in the plug with supply ports in the valve body, introducing the correct proportion of hot and cold water. 5. This action automatically generates blended hot water through all rated flow capacities at the chosen preset temperature (± 4 o F). Hot Water In Blended Water Out Cold Water In The integral fail-safe system permits steam travel in the event of plug restriction or parts failure, opening an auxiliary cold water port. Cold water flooding yields cooler water, or when parts fail, no water at all. Temperature is easily adjusted by side-to-side movement of the control rod on the valve body. Stabilization adjustments are made during initial startup by rotation of the control rod. All settings are locked in with a locking ring and set screw. 2

Operational Overview Blending Valve Diaphragm Steam Vent Plug Heat Exchanger Shell Spiral tube heating coil Differential Sensing Head Temperature Control Rod Steam Pressure Gauge Hot Water Exiting Coil Pressure Sensing Line Proportioning Plug Cold Water Entering Coil Cold Water Inlet Connection Incoming Steam Supply Water Temperature/ Pressure Gauge Hot Water Outlet Connection Condensate out to drip trap Condensate out to main trap Note: Domestic water heating applications with steam supply pressure greater than 15 psi require a steam pressure reducing valve as well as a separate steam pressure relief valve to be installed in the incoming steam supply line prior to the heat exchanger shell. Hubbell can supply the pressure reducing valve as an option. Steam pressure relief valve supplied by others. 1. Cold water enters via the inlet piping and branches off to supply both the cold port on the blending valve and the heat exchanger. 2. The cold water passes through the coils in the heat exchanger and is heated by the surrounding steam in the shell. 3. Hot water exits the heat exchanger and enters the hot port on the blending valve. 4. The plug assembly in the blending valve opens the hot and cold ports to provide the precise amount of hot and cold water in order to achieve the desired output temperature water ±4 o F. 5. The heated water exits the unit at the base of the blending valve. 3

The factory-supplied, all welded, heavy duty steel stand is high enough to accommodate the condensate piping and traps, therefore no special field-erected stand is required. Hubbell is committed to increasing operating efficiencies and improving safety features. Therefore, each water heater is supplied with a factory jacketed and insulated heat exchanger. Without this feature, the heat exchanger (with a surface temperature in excess of 200 o F) acts as a radiator and adds to heat loss inefficiencies, and is a severe safety hazard for personnel who may inadvertently come in contact with the surface of the exchanger. The Hubbell water heater will fit through most doorways, for simple and time saving installation. With only 7 square feet of floor space required for installation, compared to conventional storage water heaters the Hubbell water heater will require significantly less mechanical room space. Traps and strainers are factory piped, assembled and tested to save time and money during installation and start-up. Built-in relief valve (water side) set at 165 psi to signal over-pressure condition. General Configuration Model F Water Heater Specifications Orientation: Vertical Installation: Floor Mounted Space Requirement: 7 Sq.Ft. Certification: ASME Section VIII U or UM Waterside WP: 160 psi (max) Shell Material: Ductile Iron Shell Rating 75 psi @ 350 o F Coil Rating 150 psi @ 400 o F Coil Material: Copper Tubing SB75 Coil Size F15 - F90: 0.5" O.D. 18 BWG F105 - F120: 0.625" O.D. 18 BWG Ideal Water Temperature Operating Range: 105-185 o F Main Condensate Trap: F&T Type Drip Trap: Steam Pressure Gauge: Water Gauge: Thermostatic Type 30" Hg - 30 psig 70-270 o F, 0-200 psi 20-120 o C, 0-1400 kpa Frame: Protective Shroud: Insulation: Strainers: Warranty (Standard) Shell: Coil: Steel Angle Iron 20 GA Galvanized Steel 2 Lb. Density Fiberglass Y Cast Iron 20 MESH Screen 5 year 5 year Shipping Weight (Lbs.) F15/F30: 320 F45/F60: 405 F75/F90: 450 F105/F120: 615 Piping Water: Steam: Brass Black Iron 4

Outline Dimensions B Cold Water Inlet C Heat Exchanger See Note 1* Below Top View Protective Shroud With Insulation Blending Valve Steam Inlet A Union Strainer Hot Water Outlet Support Stand Condensate Outlet Drip Trap Union Main Condensate Trap Front View B Side View Model F Dimensional and Connection Sizing F15 F30 F45 F60 Height A 49" 49" 52" 52" 67" 67" 68" 68" Width B 26" 26" 26" 26" 26" 26" 26" 26" Length C 39" 39" 39" 39" 39" 39" 39" 39" Cold Water Inlet (Male NPT) Hot Water Outlet (Female NPT) Steam Inlet (Female NPT) Main Condensat (Trap Size) 1 1 1 1 /2 1 1 /2 2 1 /2" 2 1 /2" 2 1 /2" 2 1 /2" 2" 2" 2" 2" 2 1 /2" 2 1 /2" 2 1 /2" 2 1 /2" 3" 3 " 4" 4 " 4" FLG 4" FLG 4" FLG 4" FLG 1 1 /4" 1 1 /4" 2" 2" 1 1 1 1 1 /2" Drip Trap Size 1 /2" Steam Consumption Formula GPM x 500 x o F T = Lbs./Hr. Steam Latent heat of steam F75 F90 F105 F120 Steam Pressure (psi) 0 2 5 10 15 20 25 30 40 50 Latent Heat 970 966 960 953 946 939 933 929 920 912 Note: 1. Not to be used as a submittal drawing. Steam component locations change with differing steam pressures. 2. A pressure relief valve is required when steam supply pressure is in excess of heat exchanger rating. 5

6 Recovery Rate Chart Recovery Rates in GPM Base Model F15 F30 F45 F60 F75 F90 F105 F120 For domestic water heating applications optimum performance (±4 F) is achieved when the steam pressure in the heat exchanger shell is 15 psi or less. Therefore, if the steam supply pressure is greater than 15 psi a pressure reducing valve is used to reduce the steam pressure in the heat exchanger shell to a maximum of 15 psi. For typical process or general applications with less stringent temperature control requirements (±8 F) up to 35 psi steam pressure in the heat exchanger shell may be utilized. If incoming steam supply pressure is greater than 35 psi a pressure reducing valve is used to reduce steam pressure in the heat exchanger shell to a maximum of 35 psi. Supplied domestic water pressure needs to exceed steam pressure F In/out Temp. Steam Supply Pressure (psi) Steam Supply Pressure (psi) 40-120 14 15 15 15 12 15 16 16 40-140 10 11 12 14 11 14 15 15 40-160 8 9 10 11 10 12 13 13 40-180 7 8 9 10 9 11 12 12 60-120 15 15 15 15 14 18 19 19 60-140 12 13 14 15 13 16 17 17 60-180 8 9 10 11 10 12 13 13 40-120 27 30 30 30 24 30 33 33 40-140 20 22 24 27 22 28 30 30 40-160 16 18 20 22 19 24 26 26 40-180 15 17 19 21 17 22 23 23 60-120 30 30 30 30 28 35 38 38 60-140 23 25 27 30 25 31 34 34 60-180 21 22 23 24 19 24 26 26 40-120 41 45 45 45 36 45 50 50 40-140 33 38 41 44 33 42 45 45 40-160 26 31 33 35 29 36 39 39 40-180 16 17 19 21 26 32 35 35 60-120 45 45 45 45 43 54 58 58 60-140 40 42 44 45 38 47 51 51 60-180 22 25 29 33 29 36 39 39 40-120 54 60 60 60 48 60 66 66 40-140 46 54 58 60 44 56 60 60 40-160 34 41 44 46 38 48 52 52 40-180 21 23 25 28 34 43 46 46 60-120 60 60 60 60 57 73 78 78 60-140 57 59 60 60 50 62 68 68 60-180 29 33 39 44 38 48 52 52 40-120 68 75 75 75 60 75 84 84 40-140 58 68 73 75 55 70 75 75 40-160 43 51 55 58 48 60 65 65 40-180 26 29 31 35 43 53 58 58 60-120 75 75 75 75 72 90 97 97 60-140 71 74 75 75 63 78 85 85 60-180 36 41 49 55 48 60 65 65 40-120 81 90 90 90 72 90 99 99 40-140 69 81 87 90 66 84 90 90 40-160 51 61 66 69 57 72 78 78 40-180 31 34 37 42 51 64 69 69 60-120 90 90 90 90 86 111 118 118 60-140 85 88 90 90 75 93 102 102 60-180 43 49 58 66 57 72 78 78 40-120 95 105 105 105 84 105 118 118 40-140 81 95 102 105 77 98 105 105 40-160 60 72 77 81 67 84 91 91 40-180 37 40 44 49 60 74 81 81 60-120 105 105 105 105 101 126 136 136 60-140 100 103 105 105 88 109 119 119 60-180 51 58 68 77 67 84 91 91 40-120 108 120 120 120 96 120 132 132 40-140 92 108 116 120 88 112 120 120 40-160 68 82 88 92 76 96 104 104 40-180 42 46 50 56 68 85 92 92 60-120 120 120 120 120 115 149 158 158 60-140 114 118 120 120 100 124 136 136 60-180 58 66 78 88 76 96 104 104

Heating Coil Steam Shell F Model Optional Equipment NOTE: Other optional features are available, please consult factory if required. 1. Double wall tubing with leak detection port and U-Tube design 2. Tubing materials: Standard is copper. Optional materials are Admiralty, 90/10 Copper-Nickel, Stainless Steel (Type 304 or 316), Other: Note: Tubing materials other than copper will exhibit lower maximum capacities. To determine actual capacity, multiply the GPM rating on page 6 by the following: 0.95 Admiralty 0.81 90/10 Copper-Nickel 0.81 Stainless Steel 1. Shell construction: Standard is Ductile Iron. Optional materials are Cast Steel, Cast Bronze, 90/10 Copper-Nickel, Stainless Steel (Type 304 or 316), Other: Note: Cast steel shell ratings: 150psi @ 400 F Recirculation Packages (pump by others): 1. Fixed temperature ( o F) 3-way diverting valve, one (1) 1" globe valve, and two (2) 1" check valves are shipped loose for in-the-field installation. Model F Number Designation Operating Controls 1. In order to limit the steam pressure in the heat exchanger shell a steam pressure reducing valve is factory supplied and shipped loose for in-the-field installation. 2. Single solenoid safety system opens the sensing line to the blending valve in order to limit the hot water output in the event of an over temperature condition. Requires 5 Amp, 120 Volt service. 3. Double solenoid safety system opens the sensing line to the blending valve as well as closing the steam supply to the heat exchanger in the event of an over temperature condition. Requires 5 Amp, 120 Volt service. 4. All steam components (traps, strainers) shall be Cast Steel construction. 5. If water hardness exceeds 120 ppm, scale buildup can reduce efficiency. A factory packaged Klean-Koil Kit TM with built-in connections will allow for quick and easy in-place cleaning of the coil to remove these deposits thereby avoiding long periods of down time and expensive maintenance costs. 6. Optional temperature control to ±3 F of set temperature. 7. All 316 Stainless Steel blending valve and 316SS water piping. 2. Same as Option 1 except the 3-way diverting valve has an adjustable range. 3. The 3-way diverting valve is factory fitted and piped to the water heater. Please note: optional equipment may impact overall dimensions and weight. Please request submittal drawing from factory. CS RN Step 1 Base Model Number: F15 F30 F45 F60 F75 F90 F105 F120 Step 2 Coil: CS = Copper (Standard) AD = Admiralty CN = 90/10 Copper-Nickel SS = Stainless Steel (Specify type) Example: F30CSRN - H An instantaneous steam fired water heater with a F30 base recovery rating, copper tubing heating coil, ductile iron heat exchanger shell, with a steam pressure reducing valve factory supplied to limit the steam pressure to 15 psi maximum. Step 3 Shell: RN = Ductile Iron (Standard) SS = Stainless Steel (Specify type) ST = Cast Steel CN = Copper-Nickel CB = Cast Bronze Step 4 Options: A = Recirculation package Please specify if fixed or adjustable range and if shipped loose or factory installed on heater. C = Single solenoid safety system D = Double wall heating coil (U-Tube design) F = Double solenoid safety system H = Steam pressure reducing valve factory supplied K = Klean-Koil Kit TM factory supplied for in-place coil cleaning Option Note Any and all optional equipment for a water heater must be called out in the written specifications. A model number in and of itself does not necessarily reflect all optional equipment selected. 7

Master Specification: Model F Job Name engineer Representative contractor GENERAL Provide a quantity of instantaneous steam fired water heater(s) Model no. as manufactured by HUBBELL, Stratford, CT. The water heater(s) shall be factory assembled, packaged and ready for service connections. The entire unit shall be factory supplied with the necessary structural support stand to raise the heater the proper distance off the ground to allow for immediate installation in the field. The unit must be designed and fabricated in strict conformance with the ASME code Section VIII UM, Division I and stamped, certified, and registered with the National Board of Boiler and Pressure Vessel Inspectors. The heating coil and all other water carrying components shall be rated for 150 psi (225 psi TP) working pressure. The unit shall not contain any storage capacity nor require the use of thermostatic control devices or a temperature/pressure relief valve. The heater(s) shall be capable of maintaining the set temperature within ±4 o F over a flow range of a few percent to 100% rated capacity. HEATING COIL The water heater shall be rated to heat GPM of water from o F to o F when supplied with psig of steam to the heater. The heating coil shall be constructed of single wall ( Optional Specification: Double Wall ) copper tubes ( Optional Specifications: Admiralty, 90/10 Copper-Nickel, Stainless Steel [Type 304 or 316] ) spirally wound and brazed/welded into the manifold. No baffles or other supports shall be used in the shell. The coil must be capable of being removed for inspection and service without breaking any threaded steam or water connections or removing the unit from its installed position. HEAT EXCHANGER The heat exchanger shall be Ductile Iron ( Optional Speci ication: Cast Steel, Cast Bronze, 90/10 Copper-Nickel, Stainless Steel (Type 304 or 316) construction and shall be factory insulated to improve efficiency and reduce heat loss. The heat exchanger shall also be encased in a heavy gauge galvanized steel shroud to protect personnel from accidental contact with the exterior of the heat exchanger. OPERATING CONTROLS The water heater shall be supplied with all steam condensate controls factory assembled, piped and tested, including a drip trap, main condensate trap, and strainers. The heater(s) shall incorporate an integral safety system which automatically suppresses over-temperature conditions without the use of electrically operated devices. A steam pressure gauge (30" Hg - 30 psig) and a combination water temperature/pressure gauge (70-270 o F, 0-200 psi) are supplied and shipped loose for in-the-field installation. A steam pressure reducing valve (shall, shall not) be provided by the factory to limit the steam supply pressure in the heat exchanger shell to a maximum of 15 psi ( Optional Specification: psi ). The pressure reducing valve shall be Cast Iron ( Optional Specification: Cast Steel ) construction and shipped loose for in-the-field installation. In addition, the water heater may be supplied with the following optional features: Option Recirculation package including one (1) 1" 3-way diverting valve, one (1) 1" globe valve, and two (2) 1" check valves. Please specify: Diverting valve is (fixed or adjustable) temperature range type. Recirculation package components (shall or shall not) be factory piped and assembled on the water heater. Option Single solenoid safety system factory assembled to open the sensing line to the blending valve and thereby closing the blending valve in the event water temperature exceeds the hi-limit set point. Please specify automatic or manual reset type. Requires 120 volt, 5 amp electrical service. Option Double solenoid safety system closes the steam supply to the heat exchanger in addition to closing the blending valve. Requires manual resetting. Requires 120 volt, 5 amp electric service. Option Heat exchanger coil supplied with a factory packaged Klean-Koil TM System for quick in the field removal of mineral deposits in the coil. System includes factory installed coil connections for acid cleaning, acid pump with connections, acid holding container and 1 gallon of acid cleaner. Option A steam pressure relief valve rated at psi. WARRANTY The water heater shall be guaranteed for a period of five (5) years Non-Pro Rated from date of shipment.( Optional Specification: ten (10) year Non-Pro Rated Warranty ). Specifically, the coil assembly shall carry an unconditional, Non-Pro Rated five (5) year guarantee from failure due to thermal shock, mechanical failure, or erosion. Additionally, the heat exchanger shell shall be warranted against all failures for the same five (5) year period. All other components including the blending valve and components shall be warranted for a period of one (1) year against failure due to defects in materials or workmanship. Committed to continuous improvement... Continuing research results in product improvement; therefore specifications are subject to change without notice. For the most updated information, consult the factory directly. The Electric Heater Company P.O. Box 288 Stratford, CT 06615-0288 Phone: 203-378-2659 Fax: 203-378-3593 info@hubbellheaters.com www.hubbellheaters.com [Rev B]