our contribution for Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps environmental protection Type SCM PN40

Similar documents
Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

Selfpriming Centrifugal Pumps. Type HZS/HZSA

Centrifugal Pumps with Shaft Sealing and Priming Stage Type HZS / HZSA

Inline-Pumps Type NCV /NCVL

Centrifugal Pumps acc. to EN / ISO 2858 with Shaft Sealing Type NCL

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

Centrifugal Pumps acc. to DIN EN ISO 2858 with Shaft Sealing Type NCL

Series SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec

Horizontal Split Case Pumps Type U

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

MAGNETIC DRIVE PUMPS AMERICA S MOST VERSATILE LINE OF CENTRIFUGAL PUMPS THINK QUALITY...THINK DELIVERY...THINK PRICE

Heavy Duty Process Pumps API 610/ISO 13709

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y SMF. Vertical Submersible Pump

Operation / Installation Instructions NMB. No. 44.NMB.E3.02/11. Original Manual DICKOW PUMPEN KG

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

SIHI multi Modular multistage pumps

Upompe Primeflo XP7 chemical self-priming centrifugal pumps

Combi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

Lenntech. Tel Fax bar. Multistage Pumps.

PRODUCT INFORMATION. Liquid ring vacuum pumps Liquid ring compressors. Series LVP

CR A-F-A-E-HQQE 3x400/ HZ

Technical Parameter: Suction Diameter: 40~250 mm Discharge Diameter: 25~200 mm

Pumps Mixers Aeration Controls Services SCANPUMP SPLIT CASING PUMP Z22.

Experience In Motion. WXH and WXM Utility-Grade Multistage Ring Section Pumps

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

MARLOW PUMPS RECIRCULATION

CAP SERIES SEWAGE AND WASTE WATER PUMPS

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

This label warns for risk of electrical shock when failing to observe.

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

SECTION STEAM CONDENSATE PUMPS

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

CR20-07 A-F-A-E-HQQE 3x400/ HZ

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

380 Series Multi-Stage Centrifugal Pumps

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

TECHNICAL DESCRIPTION

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

CR A-F-A-E-HQQE 3x400/ HZ

Vertical Ring-section Pump WKTB. Type Series Booklet

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

ETP Series - Self Priming Pumps

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

TECHNICAL DESCRIPTION

Chemical Motor Pump Unit BN

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

380 Series Multi-Stage Centrifugal Pumps

SUBMERSIBLE PUMPS For water with particulate matter 2 pole - 50 Hz 2 ranges : SS 304 & SS 316 L

CRN A-F-G-E-HQQE 3x400D 50 HZ

Multifunction pump for handling gaseous liquids in process engineering

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

PREMIUM MAGNETIC-DRIVE SEALLESS CENTRIFUGAL PUMPS DB & SP SERIES

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

CAST IRON IMPELLER B4JRMBH. TYPE B SINGLE STAGE CENTRIFUGAL PUMP Bearing Frame Mount TABLE I

SAM TURBO INDUSTRY LIMITED

FAN ENGINEERING. Sealing of Fan Housings

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump

Submerged Pumps and Expanders with Magnetic Coupling for Hazardous Applications

VRD. Sump pump for polluted liquids

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

K4RH(X) Solids-Handling Pumps

Full-line Product Overview

MCV - MCH - MCHZ Multistage pumps

Pumps SELECTION OF A PUMP

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y HVN. Double Suction, Heavy Duty API 610 Process Pump (BB2)

Specially Designed Waste Water & Sewage Pumps

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

EBARA. Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

CombiPrime Self-priming centrifugal pumps

W+ Pumps. Minimize Life Cycle Costs

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

Pumps Mixers Aeration Controls Services SCANPUMP PROCESS PUMPS, BE SERIES. NO-COMPROMISE PUMPING.

PUMPS & PUMPING SYSTEMS FOR THE CHEMICAL PROCESSING & HEATING & AIR CONDITIONING INDUSTRY

Chemical Pumps Vertical Chemical Pump Type TNP

SL S.S.N.51D

Design And Analysis Of Centrifugal Pump

The sealless FLUX F 424

KRAL Screw Pumps. L Series.

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Transcription:

Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps our contribution for environmental protection Type SCM PN40

General The DICKOW-pump, type SCM, is a selfpriming horizontal side-channel pump with magnetic coupling. The side-channel pump with its high differential head has the advantage of operating more economical than normal centrifugal pumps for low capacities and high heads. Due to these facts, the side-channel pumps are appropriate to solve many pumping problems in chemical and petrochemical industries. The SCM-pump is a heavy duty unit for handling clean liquids without solids. Sealless magnetic driven pumps are designed to improve plants and personnel safety, especially when handling toxic, explosive or other dangerous liquids which react on contact with the atmosphere. For all such services, the static containment shell replaces double acting mechanical seals with external fluid reservoires or barrier fluid circulating systems. Due to the fact that 90% of pump failures and required maintenance are caused by leaking mechanical seals, the sealless design will save maintenance and spare parts costs remarkably. Consider the reduction of the total costs of ownership. The maximum allowable operating temperature is 180 C (356 F), higher temperatures on request. Side-channel impellers / SiC insert rings The rotating star-shaped side-channel impellers are fitted in a chamber between the suction and pressure discs and keyed to the pump shaft in floating position as standard. No hydraulic thrust loads exist. To achieve selfpriming capability, best efficiency and rated differential pressure, tight clearances between the rotating impeller and the stationary discs are required. During operation with properly filled pump, a stable fluid film between the impellers and the discs will center the impeller in the chamber and avoid metallic contact between rotating and stationary parts, seizing of the impellers and decoupling of the magnets. However, at dry running conditions and when handling volatile liquids with low viscosities, this fluid film will not be available or will not offer the required stability to avoid metallic contact and seizing of the impellers. suction disc pressure disc Design The SCM-pumps are single or multistage, sidechannel pumps in heavy duty design with end suction and vertical discharge flanges. Flanges and casings are designed for a working pressure of 40 bar. The containment shells are sized according to operating pressure. The pump shaft is driven via a permanent magnetic coupling. The static containment shell forms a closed system with hermetically sealed liquid end. Diffuser The diffuser is designed as a retaining stage to avoid coasting of the pump at shut down. Sufficient liquid remains in the pump and enables a restart without problems also at operation with geodetic suction heights. impeller SiC-inserts pump shaft To increase availability and to avoid seizing of the impellers in any case, the pumps can be fitted with additional SiC-rings as an option. The SiC-rings are placed in the suction and pressure disc as well as in the impeller hub. The impeller ring will be pushed concentric to the ring in the disc by the spring and the support ring. Metallic contact between the rotating and stationary parts and seizing of the impeller are excluded. wave spring support ring circlip key

Sectional drawing suction shaft suction and temperature magnetic drive antifriction suction casing impeller diffuser sleeve pressure disc pressure casing monitoring coupling bearing bracket rotor bearing drive shaft NPSH- drain PTFE side-channel sleeve thrust driven values graphite foil impeller bearing bearing rotor sleeve pump intermediate cont. shell magnetic containment bearing shaft flange protection coupling shell Standard materials: Suction- and disch.casing, diffuser GGG40.3, 1.4408 Suction- and pressure disc GGG40.3, 1.4408 (G-X5 CrNiMo 18.10) Suction impeller GG25, 1.4408 (G-X5 CrNiMo 18.10) Side-channel impellers 1.4457 (G-X25 CrNiMo 25.9) Sleeve bearing, shaft sleeve Thrust bearing Bearing bracket Containment shell SiC dry safe coated SiC GGG40 2.4610 (Hastelloy C-4) Pump shaft 1.4021 (X20 Cr13), 1.4571 (X10 CrNiMoTi 18.10) Permanent magnet Cobalt Samarium S m2 CO 17

Suction- and pressure discs The suction- and pressure discs are sealed to the atmosphere by confined O-rings with metal to metal fit, to prevent blow outs. In the shaft area, floating graphite impregnated PTFE-inserts are located in the discs to reduce shaft deflection and wear. The differential head is built up in the sidechannel of the pressure disc. Internal circulation When the pump is in operation, it generates eddy currents which heat up the containment shell and the product in the magnet area. This heat is dissipated by an internal circulation. The circulation flow is led from discharge through the magnet area and the pump shaft to the suction disc of the last stage. Pump shaft The rigid pump shaft is carried by sleeve bearings, positioned in the pumped liquid.the generous dimensioned shaft diameter reduces deflection and ensures minimum torsional loads. Outer ball bearings The outer rotor with the drive shaft is positioned in generously dimensioned grease lubricated ball bearings. Sleeve bearings, shaft sleeve The stationary sleeve bearings, the rotating shaft sleeve and the thrust bearing are made of pure wear resistant SiC. The shaft sleeves are fitted to the pump shaft by metallic tolerance rings to avoid thermal stress. Suction impeller / NPSH-values To achieve low NPSH-conditions, a centrifugal impeller with enlarged eye area is located on suction side. The NPSH-values are based on water at 20 C (65 F). When handling boiling liquids, the required liquid level on suction side can be reduced to approximately 50% of these NPSH-values. Magnetic coupling The single elements of the multipolar magnetic coupling are manufactured of a permanent magnet material "Cobalt Samarium Rare Earth" with unlimited lifetime. The internal magnets are completely encapsulated, no contact with liquid. Energy is transmitted to the hermetically sealed liquid end by a bank of external magnets passing motive force through the containment shell to a bank of internal magnets. Inner and outer magnet rings are locked together by magnetic forces and work as a synchronous coupling. The inner magnet ring transmits the required torque direct to the impeller. Overload of the magnetic coupling and slipping will not affect demagnetization. Temperature monitoring Connections for temperature monitoring of the internal circulation flow and the containment shell surface are available as standard. For critical service conditions, we recommend the mag-safe monitoring device. Containment shell protection The clearances between the drive rotor and the bearing bracket, respectively the motor support lantern, and between the drive magnets and the containment shell are arranged such that rubbing of the magnets on the containment shell will be avoided even in the case of worn out ball bearings. Monitoring devices for the containment shell protection are available on request. Dry running protection Due to the tight clearance between the sidechannel impellers and the stage discs, the standard pump design will not tolerate any kind of dry running. Level monitoring in the suction line at flooded conditions is recommended. At selfpriming conditions with suction lift, an optoelectronic level detector can be fitted in the diffuser to monitor the required liquid level in the pump. The design with additional SiC-rings can also accept dry running for limited time. Motor load monitoring can protect the pump at dry running condition. Hazardous area Together with the required Ex-drive motors, the SCM-pumps can be applied in hazardous area Group II, Category 2. The pumps meet the basic safety and health requirements of Explosionproof Directive 94/9 EC and Machinery Directive 98/37 EC and are suitable for plants with increased safety requirement.

Performance range SCM Performance curves of the individual pump sizes, also for 1750 rpm, with NPSH-values and power consumption, are available on request. Issue 08.08 Technical changes reserved. Printed in Germany. 060-09.08 S&W DICKOW PUMPEN KG Postfach 1254 84465 Waldkraiburg Germany Tel. ++ 49 86 38 6 02 0 Fax ++ 49 86 38 6 02 200 + 6 02 201 info@dickow.de / export@dickow.de www.dickow.de