Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

Similar documents
Global Water Instrumentation, Inc.

ELP21LU3-LF-HLOL THREE CHANNEL

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

RAM3 Remote Alarm Module

LMA LINE MONITOR ALERT USER S MANUAL

ESP TECHNOLOGIES LIMITED

Model A1600 Series Annunciator

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

DEMA 830 Laundry Master TM Installation Instructions

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Instruction Manual WARNING

Controllers. Instruction Manual WARNING

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

GAS MONITOR Model Model

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

OPERATING INSTRUCTIONS

Model A1700 Series Annunciator

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

Beacon 800 Gas Monitor Operator s Manual

Installation, Operation, Maintenance, Spare Parts, and Exploded Views Guide

OPERATION AND MAINTENANCE MANUAL ELC-810 AUTOMATIC WATER LEVEL CONTROLLER. AquatiControl Technology

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

CA5000 Liquid CO 2 Freezer Backup System

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Propane Fume Detection System With Solenoid Valve Control

Model 9001, Alarm

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

Remote Alarm Panels Features

Model 4001 Series Single Channel Controller

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

introduction Submittal Data Sheet CENTRA-GUARD POINT LEAK DETECTION

Propane Fume Detection System

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Mark 25 Ultrapure Water Conductivity Analyzer

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

INSTALLATION AND INSTRUCTION MANUAL

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

SIMPLEX WEATHERPROOF CONTROL PANELS

Propane Fume Detection System With Solenoid Valve Control

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

INSTRUCTION MANUAL A131 High Level Audible Warning System

Product Specifications Warning Light Control Cabinet

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

GasSens. Hydrogen Peroxide Monitor. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

VA301C CONTROLLER WITH BACnet OPTION

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Model 405 AIRGARD Fume Hood Monitor

FlowMark Model Mark-II-SC Installation Operation Manual. EPA Est.#: FL-1

M O D E L S FIREGARD BV EXTENDED PERFORMANCE RELEASE DEVICE

NXM2G Installation and Operating Manual

Deluxe Discharge Alarm

EOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #

Series M22 Signaling Beacons and Alarms

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

Owner s Manual RD432-0 Chemical Controller

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Beacon 410A Gas Monitor Operator s Manual

Model 9001, Alarm

21-light Remote Annunciator. Owner s Manual

Product Specifications Warning Light Control Cabinet

4 & 8-POINT ANNUNCIATORS Instruction Manual

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

FW-RA-LED Remote Multiplex Annunciator Panels

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Single Station Remote Alarm

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

MACHO POP Instruction Manual Model 2554EX, 2554BCX

Centro-Matic Automated Lubrication Systems System Controls

Safe T Net 210. Instruction Manual Part Number Mar2010

Control Panel For Water Wash Hoods AM2

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

Transcription:

JWB Company Leak Detection System Leak Minder Model: LDA-1 www.jwbcompany.net Instruction Manual

JWB Company For Support and Service: 65 August Avenue Wolcott, CT 06716 (203) 879-6959 (203) 879-7299 FAX www.jwbcompany.net jwbcompany@aol.com Model: LDA-1 Serial #

Model Leak Minder LDA-1 Leak Detection System Instructions Please read all instructions BEFORE installation 1) LDA-1-Checklist of Materials a) leak detection system in PVC enclosure with alarm horn, strobe light and silence button b) leak detection probe with 16 feet of cable 2) Operation- The leak detection system will sound a loud speaker/horn and flash a bright red strobe light when a switch signal is detected from the leak detection probe. Leak Detection System Installation 1) The leak detection system comes with 2 NPT male process connection that mounts to the top of the tank. 2) FIRST. Drop the leak detection probe into the vessel that you wish to be monitored for leakage. Feed the cable through the 2 NPT connector and terminate at the probe terminal in the center bottom of the board. The are marked +ve (black wire) and ve (white wire). Be sure to terminate the wires to the proper termination. 3) SECOND. If utilizing the auxiliary relay feature wire in to the terminal marked Relay. You have a choice of a normally open (NO) or normally closed (NC) contact. Relay is rated at 120 VAC/5A. You will have to make a hole in the enclosure housing to run the alarm relay wires to an external device such as a PLC or control system. 4) THIRD. Wire in the AC power to the far left terminals labeled 120VAC. Unit requires 110 VAC primary power. 5) Testing- The leak detection system has been factory tested for proper operation. However if you wish to test the system before you install the probe simple dip the leak detection probe in a cup of water. The alarm horn and strobe light will activate. To deactivate remove the leak detection probe from the water. You may silence the alarm horn by pressing the silence button on the bottom left hand side of the enclosure. The strobe light will continue to flash if liquid is present. Unit automatically resets when liquid is no longer present. 6) Should the leak detection probe fail, be disconnected or the interconnection cable is cut the strobe light will illuminate solid, however the horn will not activate.

Leak Detection Wiring Diagram Schematic Close up view Alarm Alarm Relay Contact (if used) Left Terminal: Normally Closed (NC) Center Terminal: Common (C) Right Terminal: Normally Open (NO) Leak Probe Terminal Wire white wire to (-) Wire black wire to (+) Lamp Terminal Prewired from factory White wire to (N) Black wire to (L) User Replaceable Fuse 1A, slo blo AC/115 VAC Power Terminal Wire neutral power to (N) Wire line power to (L) Center terminal is not used

Leak Detection Enclosure Leak Detection Probe Specifications 1) Output (optional): Form C Contact NO/NC (5A @ 120 VAC) 2) Operating Voltage: 115 VAC 3) Visual Alarm: Strobe light with red lens (approx. 1 Hz) -note: lamp will activate solid if probe is not connected or if probe fails 4) Audible Alarm: 95 db, 2900 Hz sounder 5) Enclosure: PVC, NEMA 4X weather resistant with 2 NPT male process connection 6) Weight: 2.5 lbs without sensor 7) Fuse: 1A slo blo type, 5 X 20 mm 8) Leak probe: conductance type, 16 feet of cable (longer lengths available) completely potted and sealed for submergence. 9) One year factory warranty Warranty Policy JWB Company warrants equipment of its own manufacture to be free from defects in material and workmanship, under normal conditions of use and service, and will replace any component found to be defective, on its return to JWB Company within one year of its original purchase. A RMA (return material authorization) is required as well as the serial number of the unit. Transportation charges to and from the factory are the responsibility of the purchaser. JWB Company also assumes no liability, expressed or implied, beyond its obligation to replace any defective component involved. Such warranty is in lieu of all other warranties, expressed or implied.