OIL SEPARATORS APPLICATIONS

Similar documents
SOLENOID VALVES FOR REFRIGERATING SYSTEMS

DEHYDRATORS AND FILTERS

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

Dehydrators and Filters

CHECK VALVES INSTALLATION

PWM expansion valves 2028

Accumulators - Suction Line

Tube-in-tube heat exchanger Type HE

TURBOIL (welded) / TURBOIL-F (flanged)

REFRIGERATION PRODUCTS

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

Filter Driers with Replaceable Core

Check valve Types NRV and NRVH

This chapter is devided into two sections:

Manual Barrel-Dosing Pump BDP

Fundamentals of Refrigeration Part 2 Refrigeration 1

64 bar. DCY-P6 / 64 bar (928 psig) Anti-acid filter driers 1.9. subcritical. Refrigeration & Climate Components Solutions.

HANDBOOK REFRIGERATING SYSTEM PROTECTORS. Ed REFRIGERATING SYSTEM PROTECTORS DP-ED 01/ ENG 1

THERMAL SOLUTIONS COAXIAL HEAT EXCHANGERS WKE, WKC

Pressure Enthalpy Charts

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

General information on refrigerant controllers

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

STARBOX - CONDENSER UNITS

Technical Development Program

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A5 - A6 - A7 - A7,5 - A8 - A9 - A10

EN aquatech.piovan.com

INSTRUCTION AND MAINTENANCE MANUAL

RD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

CO2 TRANSCRITICAL BOOSTER SYSTEMS

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Liquid Distributor Type RD

kw COOLING kw HEATING

RCY. Filter drier receiver units 4.1. Refrigeration & Climate Components Solutions. n Applications

VCYL. Liquid sight glasses 9.1 NEW. Refrigeration & Climate Components Solutions. Max WP 46 bar and multi-fluids (G1 or G2) n Applications

PDF Created with deskpdf PDF Writer - Trial ::

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

HVAC Fundamentals & Refrigeration Cycle

Energy Use in Refrigeration Systems

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A)

DDNCY (Temporary use)

30GN FLOTRONIC II AIR-COOLED CHILLERS

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

Low Pressure Sight Glass Up to 35 bar MWP Type SG

Tube-in-tube heat exchanger Type HE

y Small dimensions. Easy to install in refrigerated counters or cold rooms

Refrigerant Transfer and Compressor Damage

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Refrigeration Systems

Suction Accumulators. Introduction. Suction Accumulators

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

F Series - Refrigeration dryers

APPLICATION and INSTALLATION

30GT FLOTRONIC AIR-COOLED CHILLERS

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Compressed air preparation Compressed air storage Moisture management. Catalog #1

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

500 EX Fusion Compressor Series

for Valve Types P-H-M-V-W-D-A

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Refrigeration Systems and Accessories

AIR COOLED CONDENSING UNIT

Refrigerant Glide and Effect on Performances Declaration

Carnot. 2. (a) Discuss the advantages of the dense air refrigeration system over an open air refrigeration system?

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

General Characteristics SM185S3QC. Dimensions. Terminal box. Electrical Characteristics. Recommended Installation torques

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

Compressors, Chillers & Condensers

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

Danfoss scroll for refrigeration LGWP MLZ/LLZ Evolution A (with POE Oil) for parallel applications

Installation and Operating Instructions. -Suction Gas Heat Exchanger-

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Operating Manual Oil Water Separator CSD3 - CSD160 Version: 12/2013/DE

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

HVAC Water chiller selection and optimisation of operation

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

Customers. The core of our innovation. Feeding&Conveying Drying Dosing Temperature Control Refrigeration. Granulation

Danfoss scroll for refrigeration LLZ013 to low temperature

Performance of an Improved Household Refrigerator/Freezer

The High-efficiency Water-cooled Chiller "H series"

Refrigeration Cycle Demonstration Unit R634

Ammonia. Background on ammonia as a refrigerant

Refrigeration Cycle Demonstration Unit R633

R718 TURBO CHILLERS AND VACUUM ICE GENERATION TWO APPLICATIONS OF A NEW GENERATION OF HIGH SPEED, HIGH CAPACITY R718 CENTRIFUGAL COMPRESSORS

Performance investigation of Air-conditioning system using ejector as expansion device

Refrigerator/Heat pump

The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder.

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Product Data Sheet Refrigeration Dryer DFX

SEMI-HERMETIC SCREW COMPRESSORS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

ISSN Vol.08,Issue.21, November-2016, Pages:

Transcription:

OIL SEPARATORS APPLICATIONS The oil separators, shown in this chapter, are classified Pressure vessels in the sense of the Pressure Equipment Directive 97/23/EC, Article 1, Section 2.1.1 and are subject of Article 3, Section 1.1 of the same Directive. They are designed for installation on commercial refrigerating systems and on civil and industrial conditioning plants, which use refrigerant fluids proper to the Group II (as defined in Article 9, Section 2.2 of Directive 97/23/EC and referred to in Directive 67/548/EEC). The advantages of the oil separator on the discharge line of a compressor in a refrigeration system are confirmed by many years of experience. The oil separator intercepts the oil mixed with compressed gas and returns it to the crankcase of the compressor thus assuring an efficient lubrication of its moving parts. Furthermore, the oil separator maintains a high coefficient of condenser and evaporator performance by almost completely removing oil deposits from their exchange surfaces. When a very high temperature at the end of the compression stage leads to the formation of oil vapours, a separator with a capacity exceeding the values shown in the table should be used. Moreover, the oil separator, damping the valves pulsations, reduces system noise with an open or semi-hermetic compressor. Finally, the use of an oil separator leads to: a longer life of the compressor; a better performance of the whole system with consequent energy saving; a quieter operation by reducing pulsations. Table 1 and 2 show the technical data relating to the working conditions of oil separators. separators series 5540 are closed type and they cannot be dismantled from the system, except cutting the piping. The body is manufactured from steel pipe of adequate thickness. Flanges and cover are also made of steel. Either threaded connections of separators series 5520 or solder connections of separators series 5540 are manufactured, machining, with steel bar EN 10277-3 11S Mn Pb 37 + C. The internal device is simple in order to assure a trouble-free long operation. Appropriate metallic screens, placed on the inlet and outlet, rapidly reduce gas speed, and create the conditions required for the separation of the oil from the refrigerant. A float operated needle valve, set on the bottom of the vessel, return the oil to the crankcase of compressor. The bottom also includes a chamber that collects all metallic debris. A permanent magnet holds these impurities to avoid they stop or damage the operation of needle, moved by floating. CONSTRUCTION Castel manufactures two types of oil separators: separators series 5520 can be overhauled for maintenance and can be replaced from the system. They are equipped with threaded connections, which can mate to the connections type 5590 (to be ordered separately) 84

SELECTING THE SIZE OF AN OIL SEPARATOR The selecting of an oil separator should be done comparing the characteristics of the installed compressor, establishing: inlet connection must agree with the discharge diameter of the compressor refrigerant flow capacity with fixed working conditions (saturated discharge temperature saturated suction temperature, eventually liquid subcooling, sucked vapour overheating). This is necessary to define the gas speed referred to the cross section of oil separator, assigned an end compression temperature. It is advisable the above-mentioned speed doesn t exceed 0,5 m/s, to avoid great swirl phenomena. Table 2 has being written following this principle. Generally, fixed the following data: refrigerating capacity of compressor, type of refrigerant and working conditions, the volumetric capacity Q, of compressed gas, is given by: Q = P [m 3 /s] with: H v g P = refrigerant flow capacity kw] H = heat content differential, see diagram (fig. 1). [kj/kg] v g = specific volume of compressed gas, separator inlet (fig. 1). [m 3 /kg]. Fig. 1 Check of gas speed, referred to the cross section of oil separator, is given by: v = Q S [m/s] with: S = gross cross section of shell separator [m 2 ] INSTALLATION The oil separators type 5520 and 5540 should be installed in the discharge line between the compressor and the condenser mounted securely in a vertical position and reasonably close to the compressor. To prevent the return of refrigerant from condenser, during the off cycle of the system, it s advisable to install a check valve between the condenser and oil separator outlet connection. Oil separator performs best when operating at or near the compressor discharge temperature. In location the oil separator, choose a position to avoid, as far as possible, chilling of the shell, which may result in condensing of liquid within the separator. If this is not possible, it is advisable to supply the separator with the better solutions (insulation, strap heater, others) to prevent the refrigerant in the system from condensing in the shell. Before the oil separator is installed, either one 5520 or one 5540, an initial charge of oil should be added to it. Refer to general characteristics of oil separators or to instruction sheet for the proper amount of oil. Oil pre-charge is very important, failure to pre-charge separator sump may result in damage to the oil return float mechanism. Use the same type of oil that is in the compressor crankcase. Acting as the lay out of refrigerating system, the return line may be run from the oil fitting to: the compressor crankcase; the suction line upstream the compressor or upstream the receiver, if present; the oil reservoir if oil control system is being used. A sight glass may be installed in the oil line, in a position that oil is flowing through the tube, to check the correct working of the oil separator. OIL SEPARATORS 85

IN OUT IN OUT outlet outlet inlet steel plate inlet steel plate steel ball oil return tube steel ball oil return tube steel needle permanent magnet steel needle permanent magnet 5540 5520 TABLE 1: General Characteristics Solder Connections ODS ODM ODS (1) Couple of solder connections IN / OUT Oil connection [SAE Flare] Oil addition [kg] Max. differential pressure [bar] min. TS [ C] max. PS [bar] Risk Category according to PED 1/2" 3/4" 1" 1/4" 0,4 / 0,5 I 5540/M 2.1/8" 54 3/8" 0,6 / 0,7 21 10 + 130 32 II 1/4" 0,4 / 0,5 I 5590/M (1) The dimensions of the separator's connections must agree with the discharge diameter of the compressor 86

Separator Connections Soder Connections 1/2" ODS TABLE 2: Dimensions and Weights Dimensions D 1 D 2 H 1 H 2 H 3 H 4 280,0 Weight [g] 4175 OIL SEPARATORS 123,0 367,0 4910 5030 8,0 58 5845 5540/M 2.1/8" 54 3,5 17,5 471,0 481,0 90 9550 339,0 61,0 400,0 6865 5590/M 123,0 154,0 394,0 67,0 92,0 461,0 486,0 79 7675 5590/.. Gasket H1 H1 H2 H4 H4 H3 D2 M10 M10 5520 D1 5540 D1 87

of solder connections TABLE 3: Refrigerant Flow Capacity Refrigerant Capacity (1) [kw] R134a R22 R404A R407C Evaporating Temperature [ C] 20 + 5 20 + 5 20 + 5 20 + 5 5,3 6,1 6,4 7,9 6,4 8,8 6,0 8,0,4 18,9 19,7 24,5 19,9 27,3 21,3 22,2 27,7 22,5 30,8 21,0 27,8 21,2 23,9 24,3 27,4 25,4 28,6 31,5,6 25,7 28,9,2 27,0,8 5540/M 33,1 38,0 49,3 40,1 54,9 37,6 49,6,5 48,8 50,9 63,4 51,5 70,6 48,3 63,7,4 18,9 21,3 19,7 22,2 24,5 27,7 19,9 22,5 27,3 30,8 21,0 27,8 21,2 23,9 24,3 27,4 25,4 28,6 31,5,6 25,7 28,9,2 27,0,8 5590/M 26,5 30,4 39,5 32,1 44,0 30,0 40,0 (1) Refrigerant flow capacity with a condensing temperature of + 40 C and normal overheating values of vapour sucked by compressor. No liquid subcooling. Maximum pressure drop of 0,15 bar 88