Chapter 10. Refrigeration and Heat Pump Systems

Similar documents
Thermodynamics II Chapter 5 Refrigeration

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Chapter 9. Refrigeration and Liquefaction

Chapter 11 REFRIGERATION CYCLES

Thermodynamics I. Refrigeration and Heat Pump Cycles

Chapter 11 REFRIGERATION CYCLES

Chapter 11 REFRIGERATION CYCLES. Department of Mechanical Engineering

Week 9. Refrigeration Cycles I. GENESYS Laboratory

Refrigerator and Heat Pump Objectives

Chapter 11. Refrigeration Cycles. Study Guide in PowerPoint

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

Homework Chapter2. Homework Chapter3

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

A Comparison Between Refrigerants Used In Air Conditioning

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

ENSC 388. Assignment #6

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Thermodynamics: Homework A Set 7 Jennifer West (2004)

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

(Refer Slide Time: 00:00:40 min)

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

HFCs or the Old Refrigerants - what is the best Choice?

PLEASE READ AND FOLLOW THESE INSTRUCTIONS

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

CHAPTER 1 INTRODUCTION

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Chapter 10 Lyes KADEM [Thermodynamics II] 2007

CHAPTER 1 INTRODUCTION


A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

R07. Answer any FIVE Questions All Questions carry equal marks *****

Engineering Thermodynamics. Chapter 7

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Natural refrigerants - naturally efficient

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

INSTITUTE OF AERONAUTICAL ENGINEERING

pdfmachine trial version

RAC. Unit 1. Previous year Questions

Chapter 8. Production of Power from Heat

Refrigerants Type Expensive Coefficient of Performance Toxic

UNIT-1 Q.1 Draw P-V and T-s diagram of Reversed Carnot cycle (2M-Apr./May-2009) Q.2 Define Ton of refrigeration and COP. (2M- Nov/Dec-2009)

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2013) 2 / 25 T270 COP R = Q L

Refrigeration Cycles. Refrigerators, Air-conditioners & Heat Pumps. Refrigeration Capacity/Performance. Dr. Md. Zahurul Haq

T270 COP R = Q L. c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2017) 2 / 23 T354

*Corresponding author;

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK

ISSN Vol.08,Issue.21, November-2016, Pages:

Comparative Exergy Analysis of Vapor Compression Refrigeration System Using Alternative Refrigerants

THEORETICAL INVESTIGATION OF THE PERFORMANCE OF SOME ENVIRONMENT-FRIENDLY REFRIGERANTS IN A SUB-COOLING HEAT EXCHANGER REFRIGERATION SYSTEM

Design of LPG Refrigeration System

TYPICAL INITIAL OUTPUT OF A CO 2 HEAT PUMP

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Ammonia. Background on ammonia as a refrigerant

Oyelami S., Bolaji B. O.

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

Refrigeration and Air Conditioning

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Engineering for the Craft Brewer. Lecture 6 Summer 2014

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

Chapter 2. Alternatives to HCFCs and their Characteristics

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

S.A. Klein and G.F. Nellis Cambridge University Press, 2011 = 90 F. compressor. condenser. 5 evaporator 1. evap

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

η second law = Second law efficiency

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

LPG Refrigerator. October 2017 IJIRT Volume 4 Issue 5 ISSN:

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

ADVANCES in NATURAL and APPLIED SCIENCES

Design of a Low capacity Evaporator of a Refrigeration Unit

Performance and exergy analysis of vapour compression refrigeration system using various alternative of R134a.

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Environment Protection Engineering

March 10, 2016 San Joaquin Valley RETA Meeting

Carnot. 2. (a) Discuss the advantages of the dense air refrigeration system over an open air refrigeration system?

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Volume 2, Issue 1 (2014) ISSN International Journal of Advance Research and Innovation

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

高溫熱泵產製蒸汽之低溫廢熱回收. Sep. 6, 2013

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Volume 1, Issue 2 (2013) ISSN International Journal of Advance Research and Innovation

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Transcription:

Chapter 10 Refrigeration and Heat Pump Systems

Learning Outcomes Demonstrate understanding of basic vaporcompression refrigeration and heat pump systems. Develop and analyze thermodynamic models of vapor-compression systems and their modifications, including sketching schematic and accompanying T-s diagrams. evaluating property data at principal states of the systems. applying mass, energy, and entropy balances for the basic processes. determining refrigeration and heat pump system performance, coefficient of performance, and capacity.

Vapor-Compression Refrigeration Cycle Most common refrigeration cycle in use today There are four principal control volumes involving these components: Evaporator Compressor Condenser Expansion valve Two-phase liquid-vapor mixture All energy transfers by work and heat are taken as positive in the directions of the arrows on the schematic and energy balances are written accordingly.

The Vapor-Compression Refrigeration Cycle The processes of this cycle are Process 4-1: two-phase liquid-vapor mixture of refrigerant is evaporated through heat transfer from the refrigerated space. Process 1-2: vapor refrigerant is compressed to a relatively high temperature and pressure requiring work input. Process 2-3: vapor refrigerant condenses to liquid through heat transfer to the cooler surroundings. Process 3-4: liquid refrigerant expands to the evaporator pressure. Two-phase liquid-vapor mixture

The Vapor-Compression Refrigeration Cycle Engineering model: Each component is analyzed as a control volume at steady state. The compressor operates adiabatically. The refrigerant expanding through the valve undergoes a throttling process. Kinetic and potential energy changes are ignored.

The Vapor-Compression Refrigeration Cycle Applying mass and energy rate balances Evaporator Q in Q m (Eq. 10.3) The term is referred to as the refrigeration capacity, expressed in kw in the SI unit system or Btu/h in the English unit system. A common alternate unit is the ton of refrigeration which equals 200 Btu/min or about 211 kj/min. in = h 1 h 4

The Vapor-Compression Refrigeration Cycle Applying mass and energy rate balances Compressor Assuming adiabatic compression Condenser Expansion valve Assuming a throttling process W c m Q m out = = h h 4 = h 3 2 h 2 h 1 h 3 (Eq. 10.4) (Eq. 10.5) (Eq. 10.6)

The Vapor-Compression Refrigeration Cycle Performance parameters Coefficient of Performance (COP) Carnot Coefficient of Performance (Eq. 10.7) (Eq. 10.1) This equation represents the maximum theoretical coefficient of performance of any refrigeration cycle operating between cold and hot regions at T C and T H, respectively.

Features of Actual Vapor-Compression Cycle Heat transfers between refrigerant and cold and warm regions are not reversible. Refrigerant temperature in evaporator is less than T C. Refrigerant temperature in condenser is greater than T H. Irreversible heat transfers have negative effect on performance. Back of Refrig. Keep Ice Cream Cold

Features of Actual Vapor-Compression Cycle The COP decreases primarily due to increasing compressor work input as the temperature of the refrigerant passing T refrigerant through the evaporator is reduced relative to the temperature of the cold region, T C. temperature of the refrigerant passing T refrigerant through the condenser is increased relative to the temperature of the warm region, T H.

Features of Actual Vapor-Compression Cycle Irreversibilities during the compression process are suggested by dashed line from state 1 to state 2. An increase in specific entropy accompanies an adiabatic irreversible compression process. The work input for compression process 1-2 is greater than for the counterpart isentropic compression process 1-2s. Since process 4-1, and thus the refrigeration capacity, is the same for cycles 1-2-3-4-1 and 1-2s-3-4-1, cycle 1-2-3-4-1 has the lower COP.

Isentropic Compressor Efficiency The isentropic compressor efficiency is the ratio of the minimum theoretical work input to the actual work input, each per unit of mass flowing: work required in an isentropic compression from compressor inlet state to the exit pressure (Eq. 6.48) work required in an actual compression from compressor inlet state to exit pressure

Actual Vapor-Compression Cycle Example: The table provides steady-state operating data for a vapor-compression refrigeration cycle using R-134a as the working fluid. For a refrigerant mass flow rate of 0.08 kg/s, determine the (a) compressor power, in kw, (b) refrigeration capacity, in tons, (c) coefficient of performance, (d) isentropic compressor efficiency. State 1 2s 2 3 4 h (kj/kg) 241.35 272.39 280.15 91.49 91.49

Actual Vapor-Compression Cycle State 1 2s 2 3 4 h (kj/kg) 241.35 272.39 280.15 91.49 91.49 (a) The compressor power is W c W c kg = 0.08 s = m ( h h1) 2 kj (280.15 241.35) kg (b) The refrigeration capacity is Q in = m ( h h4) 1 1kW 1kJ/s = 3.1 kw Q in = 0.08 kg s (241.35 91.49) kj kg 1ton 211kJ/min 60 s min = 3.41 tons

Actual Vapor-Compression Cycle State 1 2s 2 3 4 h (kj/kg) 241.35 272.39 280.15 91.49 91.49 (c) The coefficient of performance is β = ( h ( h 1 2 h 4 h 1 ) ) (241.35 91.49)kJ/kg β = = 3.86 (280.15 241.35)kJ/kg

Actual Vapor-Compression Cycle State 1 2s 2 3 4 h (kj/kg) 241.35 272.39 280.15 91.49 91.49 (d) The isentropic compressor efficiency is η c = ( W / m ) c W c / m s = ( h ( h 2s 2 h h 1 1 ) ) (272.39 241.35)kJ/kg ηc = = 0.8 = 80% (280.15 241.35)kJ/kg

p-h Diagram The pressure-enthalpy (p-h) diagram is a thermodynamic property diagram commonly used in the refrigeration field.

Selecting Refrigerants Refrigerant selection is based on several factors: Performance: provides adequate cooling capacity cost-effectively. Safety: avoids hazards (i.e., toxicity). Environmental impact: minimizes harm to stratospheric ozone layer and reduces negative impact to global climate change.

Refrigerant Types and Characteristics Global Warming Potential (GWP) is a simplified index that estimates the potential future influence on global warming associated with different gases when released to the atmosphere.

Refrigerant Types and Characteristics Chlorofluorocarbons (CFCs) and Hydrochlorofluorocarbons (HCFCs) are early synthetic refrigerants each containing chlorine. Because of the adverse effect of chlorine on Earth s stratospheric ozone layer, use of these refrigerants is regulated by international agreement. Hydrofluorocarbons (HFCs) and HFC blends are chlorine-free refrigerants. Blends combine two or more HFCs. While these chlorine-free refrigerants do not contribute to ozone depletion, with the exception of R-1234yf, they have high GWP levels. Natural refrigerants are nonsynthetic, naturally occurring substances which serve as refrigerants. These include carbon dioxide, ammonia, and hydrocarbons. These refrigerants feature low GWP values; still, concerns have been raised over the toxicity of NH 3 and the safety of the hydrocarbons.

Ammonia-Water Absorption Refrigeration Absorption refrigeration systems have important commercial and industrial applications. The principal components of an ammonia-water absorption system are shown in the figure. Absorber coolant

Ammonia-Water Absorption Refrigeration The left-side of the schematic includes components familiar from the discussion of the vapor-compression system: evaporator, condenser, and expansion valve. Only ammonia flows through these components. Absorber coolant

Ammonia-Water Absorption Refrigeration The right-side of the schematic includes components that replace the compressor of the vaporcompression refrigeration system: absorber, pump, and generator. These components involve liquid ammonia-water solutions. Absorber coolant

Ammonia-Water Absorption Refrigeration A principal advantage of the absorption system is that for comparable refrigeration duty the pump work input required is intrinsically much less than for the compressor of a vapor-compression system. Absorber coolant

Ammonia-Water Absorption Refrigeration Specifically, in the absorption system ammonia vapor coming from the evaporator is absorbed in liquid water to form a liquid ammonia-water solution. The liquid solution is then pumped to the higher operating pressure. For the same pressure range, significantly less work is required to pump a liquid solution than to compress a vapor (see discussion of Eq. 6.51b). Absorber coolant

Ammonia-Water Absorption Refrigeration However, since only ammonia vapor is allowed to enter the condenser, a means must be provided to retrieve ammonia vapor from the liquid solution. This is accomplished by the generator using heat transfer from a relatively hightemperature source. Absorber coolant

Ammonia-Water Absorption Refrigeration Steam or waste heat that otherwise might go unused can be a costeffective choice for the heat transfer to the generator. Alternatively, the heat transfer can be provided by solar thermal energy, burning natural gas or other combustibles, and in other ways. Absorber coolant

Vapor-Compression Heat Pump Systems The objective of the heat pump is to maintain the temperature of a space or industrial process above the temperature of the surroundings. Principal control volumes involve these components: Evaporator Compressor Condenser Expansion valve

The Vapor-Compression Heat Pump Cycle Performance parameters Coefficient of Performance (Eq. 10.10) Carnot Coefficient of Performance (Eq. 10.9) This equation represents the maximum theoretical coefficient of performance of any heat pump cycle operating between cold and hot regions at T C and T H, respectively.

Vapor-Compression Heat Pump System The method of analysis for vapor-compression heat pumps closely parallels that for vapor-compression refrigeration systems. Example: A vapor-compression heat pump cycle with R-134a as the working fluid maintains a building at 20 o C when the outside temperature is 5 o C. The refrigerant mass flow rate is 0.086 kg/s. Additional steady state operating data are provided in the table. Determine the (a) compressor power, in kw, (b) heat transfer rate provided to the building, in kw, T H = 293 K (20 o C) (c) coefficient of performance. T C = 278 K (5 o C) State 1 2 3 h (kj/kg) 244.1 272.0 93.4

Vapor-Compression Heat Pump System State 1 2 3 h (kj/kg) 244.1 272.0 93.4 T H = 293 K (20 o C) T C = 278 K (5 o C) (a) The compressor power is W c W c = m ( h h1) kg = 0.086 s 2 kj (272.0 244.1) kg 1kW 1kJ/s = 2.4 kw (b) The heat transfer rate provided to the building is Q out = m ( h h3) 2 Q out = 0.086 kg s (272.0 93.4) kj kg 1kW 1kJ/s = 15.4 kw

Vapor-Compression Heat Pump System State 1 2 3 h (kj/kg) 244.1 272.0 93.4 T H = 293 K (20 o C) T C = 278 K (5 o C) (c) The coefficient of performance is Q out 15.4 kw γ = = = W 2.4kW c γ 6.4 Comment: Applying Eq. 10.9, the maximum theoretical coefficient of performance of any heat pump cycle operating between cold and hot regions at T C and T H, respectively is TH 293 K γ max = γ max = = 19.5 293 K 278 K T H T C

Brayton Refrigeration Cycle The working fluids of vapor-compression systems undergo liquid-to-vapor phase change. In Brayton refrigeration systems the working fluid remains a gas throughout. The Brayton refrigeration cycle is the reverse of the Brayton power cycle introduced in Sec. 9.6 as shown in the figure.

Brayton Refrigeration Cycle The processes of this cycle are Process 1-2: the refrigerant gas, which may be air, enters the compressor at state 1 and is compressed to state 2. Process 2-3: The gas is cooled by heat transfer to the warm region at temperature T H. Process 3-4: The gas expands through the turbine to state 4, where the temperature, T 4, is well below T C. Process 4-1: Refrigeration of the cold region is achieved through heat transfer from the cold region to the gas as it passes from state 4 to state 1, completing the cycle. The work developed by the turbine assists in driving the compressor.

Brayton Refrigeration Cycle The coefficient of performance of the cycle is (Eq. 10.11)

Automotive Air Conditioning using Carbon Dioxide Owing to its low GWP of 1, carbon dioxide, CO 2, is under consideration for use in automotive airconditioning systems. The schematic shows such a CO 2 -charged airconditioning system. It combines aspects of gas refrigeration with aspects of vapor-compression refrigeration.

Automotive Air Conditioning using Carbon Dioxide The processes of this cycle are Process 1-2: CO 2 vapor enters the compressor at state 1 and is compressed to state 2. Process 2-3: The CO 2 vapor is then cooled to state 3 by heat transfer to the ambient at temperature T H. Process 3-4: The CO 2 next passes through the interconnecting heat exchanger, where it is further cooled to temperature T 4 < T H.

Automotive Air Conditioning using Carbon Dioxide Process 4-5: The CO 2 expands through the valve to state 5, where it is a two-phase liquid-vapor mixture at T 5 < T C, the passenger cabin temperature, and then enters the evaporator. Process 5-6: As the CO 2 passes through the evaporator, it is vaporized by heat transfer from the passenger cabin. Process 6-1: Finally, CO 2 vapor passes through the heat exchanger, where its temperature is increased to T 1, completing the cycle.

Automotive Air Conditioning using Carbon Dioxide The states visited in the cycle are shown on the T-s diagram: (Critical Temperature of CO 2 )

de dt cv Vi = Q W + m i ( ui + + gzi ) m 2 2 e ( u e + V 2 e 2 + gz e ) de cv dt =! Q cv!! W cv +!m i (h i + V 2 i 2 + gz )!!m (h + V 2 e i e e 2 + gz ) e Two-phase liquid-vapor mixture