planal vertical The ultimate modern statement room, Planal Vertical radiators and exciting, flexible way to make an impression

Similar documents
UK PRICE GUIDE. January Complete with Technical Specifications for ROUND TOP, COMPACT, LST, AND TOWEL RADIATORS

LOW SURFACE TEMPERATURE RADIATORS

Technical Data 04/2005 UK VOGEL & NOOT. compactradiator VOGEL & NOOT. Wärmetechnik

VERTICAL VONOVA & VERTICAL VONOPLAN. 20 VERTICAL VONOVA & VERTICAL VONOPLAN PANEL RADIATORS. VERTICAL VONOVA Type 20. VERTICAL VONOPLAN Type 20.

Heating Emitters. Find the right radiator for each room. Radiators Towel Warmers Towel Warmer Valves 295

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

PANEL RADIATORS DESIGN RADIATORS TOWEL WARMERS.

3RD GENERATION PANEL RADIATORS

T6 - Centrally Connected & VONOPLAN T6.

PLAN KLASIK LINE KLASIK

LST Plus Vertical. Plus Vertical 3 models. Lengths: 560mm, 660mm & 760mm. Outputs: 1335 to 1862 watts, 4555 to 6353 Btu/hr

DESIGNER RADIATORS.

LST STANDARD. Safety Series

Heating. Our range of designer radiators and towel rails, brings fashion and function together beautifully. By Style

LST i PLUS. Safety Series

3RD GENERATION PANEL RADIATOR

07/ OUR COLLECTION OF DESIGNER RADIATORS AND TOWEL RAILS INSPIRE WARMTH AND ELEGANCE IN ANY BATHROOM. HEATING20. guarantees unless otherwise stated

3RD GENERATION PANEL RADIATOR

Sovereign Double CC/DD

THE PERFECT CHOICE FOR YOUR HOME

30 VIENNARAIL DESIGN RADIATORS & TOWEL WARMERS VIENNARAIL.

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

lets you create complement charm captivate

GRANGE CAST IRON RADIATORS COMMERCIAL HEATING SOLUTIONS

CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction

Power flushing and protecting your heating system can increase efficiency by at least 25%.

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER.

DESIGNER RADIATOR RANGE

Installer & User Guide Effective February 2013

Great Dudlands Gisburn Road Sawley BB7 4LH

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

105 Mount Merrion Park, Rosetta Road, BELFAST, BT6 0GA. Viewing by appointment with & through agent

Technical Checklist - Plumbing and Heating Fittings - UK Sizes

Dene Bath Shower Mixer

PRODUCTION SEQUENCES OF PAINT SHOP

(Agent Note: The Lounge and Kitchen combine to create a spacious and versatile living area with three underfloor heating zones).

188 Bangor Road Holywood BT18 0BY. Offers around 595, High Street, Holywood, BT18 9AE Tel: SALES LETTINGS PROPERTY MANAGEMENT

DESIGNER RADIATORS. July

R-RCM & R-RSB SERIES

Soldeu 4 Portsea View Bedhampton Hampshire

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

CG 00 (44)

Union coupling. copper x copper. Cone joint to BS 1010.

Quick response concealed horizontal sidewall sprinkler VK481

Cast Iron Radiators. General Information 2. Block make up 6.

Oaklea Peening Quarter Road, Wittersham, Kent TN30 7NP

Standard Spray concealed horizontal sidewall sprinkler VK481

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

Bath Shower Mixer

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

PANEL RADIATOR RANGE. inside

40 Kilraughts Road Ballymoney BT53 7HL. Viewing by appointment with & through agent

INSTALLATION & TECHNICAL MANUAL

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

DESIGNER PRODUCT GUIDE

Peter Barn. Cross Lane Waddington Clitheroe BB7 3JH

74 Eastern Way, Darras Hall, Ponteland Newcastle Upon Tyne, NE20 9RE

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

mirage standard response concealed pendent sprinkler vk492 (K5.6)

Stoves & Inserts. Gas. continentalfireplaces.com

Viewing by appointment with & through agent

Coin du Soleil 1 Clos du Petit Bois, St Martin s

Finished Excellence. Limited Lifetime Finish Warranty. Armaturen.Accessoires.Interiors.Culture Projects.

Gas Stoves & Inserts. Innovative Heating Solutions continentalfireplaces.com

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

Linea Plus. Freestanding. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

LOWLANDS ROAD AVELEY ESSEX RM15 4ED PRICE:- 440,000

Banks House Back Lane Chipping Preston PR3 2QA

FITTING, OPERATION, INSTALLATION & SERVICING INSTRUCTIONS

Air Curtains. For a better working environment. Tel:

The Barn Old Back Lane Wiswell BB7 9BS

The Downs Portsdown Hill Road Cosham

Male elbow, copper x BSP taper male thread

RODGERSANDBROWNE.CO.UK

York Villa Walmersley Road, Bury

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

EDEN. Installation Instructions. Bath shower manual mixer tap INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Mini Tender Section 1.1 External Wall Insulation, Mechanical and Electrical Installation

UNITED KINGDOM BATHROOM SPECIALS

4 Mountpleasant Drive, Newtownards, BT23 4WP. Viewing by appointment with & through agent

675,000. offers around. Chestnut Cottage 165 Bangor Road Craigavad, Holywood, BT18 0ET. 76 High Street, Holywood, BT18 9AE THE AGENTS PERSPECTIVE

Bathroom. Architectural Designer Products EVE COLLECTION

Kinetic. Logic. Astin. THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions. Please retain for future reference

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

INSTALLATION MANUAL SB-AW-SNDBR-X-B

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

x131226_manissa_inset_p10_sw_x131226_manissa_inset_p10_sw 05/03/ :50 Page 1 Heating Products 01

Devon Gardens, Low Fell, NE9 299,950 OIEO

Introducing Arcade s range of exquisitely crafted bathroom pieces, lovingly designed to create a décor that is truly unique.

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

INSTRUCTIONS FOR USE... 2

45 Canterbury Way, Cannock, WS12 3YR

Thermostatic Shower Tower Installation and Operating Instructions

ferroli Boiler Replacement Maxima 35C- Modena HE

Additions and Accessories

Wall Panelling. Finishing Touches. Accessories. Wall panelling See Page 170

Transcription:

planal vertical The ultimate modern statement for your room, Planal Vertical radiators provide a discrete, sophisticated new look and exciting, flexible way to make an impression while efficiency heating your room. 16VPH600 (technical information and valves from p. 31) p. 11

technical specifications & price list P r e m i e r R a n g e p. 31

basic heat-loss calculator According to EN 442, inlet water temperature 75 C, outlet water temperature 65 C, and room temperature is 20 C are assumed and all our heat output figures published in our publications are to EN442. The total heat output of the radiator you choose must compensate for the heat-loss of your room so that it will maintain the interior temperature at 20 C. The following calculation will give you indication of your heat-loss. If you would like to take into all the factors effecting the heat-loss then you must use more complicated heat-loss calculator that you can find at www.aeon.uk.com If you have limited space or very large room, you can always put more than one radiator per room. Preferably you should locate radiators, near windows and doors where heat-loss is highest. Measure your living room in meters : Height _m : Length_m : Depth_m ie : H:2.64m, L:3.65m, D:4.94m Calculate the volume of the room : H x L x D = Cubic meters ie : 2.64 x 3.65 x 4.94 = 47.60 cubic meters Multiply by a coefficient for each desired room temperature : 42 : bedrooms (to achieve 18 C) 52 : bathrooms, wc, living, study, dining etc (to achieve 21 C) ie : living room 52, 47.60 x 52 = 2,475 watts The heat-loss in the living room is 2,475 watts, but there are following factors we need to consider for a better result we need to add 10% for every factor given here below. - Outside walls, if it is corner room two outside walls which means (10% and 10%) - Northern aspect room - Ceiling height more than 2.7m - Excessive large windows - Single glaze - Outside temperature assumed as -1 C, but if you would like to assume -2 C add 10%, -4 C add another 10%, -10 C add another 10% ie : One outside wall, excessive window, 2,475 x 1.1 x 1.1 = 2970 watts or 2554 kcal or 10144 btu the final heat-loss calculation. Heat outputs are based on At:50 C with 75 C inlet / 65 C outlet water and 20 C room temperature. Heat-outputs of chrome multirails are reduced by 20% due to plated finish. Suffix "P" for mirror polished products, "W" for white, "B" for black, "C" for chrome, "P" for polished, "G" for Gold, SS for Stainless Steel 304 and MAT for brushed mat. Pipe centre measurements are incorporating pair of valve distance of 45mm each where applicable. Product Height Width Pipe Overall Heat Output List Price List Price Code Floor to pipe centre Centres Distance mm mm mm mm from wall Btu Watts buckingham DIN Column Chrome Gold 600/CL/250 5BE 951 534 102 320 240 2736 802 507.00 628.00 600/CL/350 7BE 951 634 102 420 240 3999 1172 567.00 707.00 600/CL/500 10BE 951 784 102 570 240 4732 1387 694.00 870.00 600/CL/700 14BE 951 984 102 770 240 6630 1943 899.00 1,117.00 captiva Wall to pipe centre SS-Mat SS-Polished CV30 1750 500 48-58 380 73-83 3979 1165 1,482.00 1,968.00 CV24 1400 500 48-58 380 73-83 3183 932 1,170.00 1,533.00 CV18 1040 500 48-58 380 73-83 2388 699 918.00 1,148.00 Width Pipe centres Buckingham Captiva p. 32 (prices shown exclude VAT)

Product Height Width Pipe Overall Heat Output List Price Code Floor to pipe centre Centres Distance mm mm mm mm from wall Btu Watts planal - Vertical (*accessories from page 47) White 12VPS200 1200 200 55 150-50 88 871 255 127.32 14VPS200 1400 200 55 150-50 88 1005 294 148.54 16VPS200 1600 200 55 150-50 88 1149 336 163.32 18VPS200 1800 200 55 150-50 88 1292 378 183.89 20VPS200 2000 200 55 150-50 88 1436 420 189.63 12VPH200 1200 200 55-77 150-50 89-111 1892 554 180.75 14VPH200 1400 200 55-77 150-50 89-111 2190 641 210.87 16VPH200 1600 200 55-77 150-50 89-111 2503 733 236.70 18VPH200 1800 200 55-77 150-50 89-111 2815 824 249.88 20VPH200 2000 200 55-77 150-50 89-111 3128 916 271.80 12VPS300 1200 300 55 250-50 88 1306 382 143.73 14VPS300 1400 300 55 250-50 88 1507 441 167.68 16VPS300 1600 300 55 250-50 88 1723 504 187.63 18VPS300 1800 300 55 250-50 88 1938 567 206.86 20VPS300 2000 300 55 250-50 88 2154 630 213.43 12VPH300 1200 300 55-77 250-50 89-111 2838 831 198.53 14VPH300 1400 300 55-77 250-50 89-111 3285 962 231.62 16VPH300 1600 300 55-77 250-50 89-111 3754 1099 260.47 18VPH300 1800 300 55-77 250-50 89-111 4223 1236 276.84 20VPH300 2000 300 55-77 250-50 89-111 4692 1374 318.09 12VPS400 1200 400 55 350-50 88 1741 510 168.09 14VPS400 1400 400 55 350-50 88 2010 588 196.11 16VPS400 1600 400 55 350-50 88 2297 672 234.51 18VPS400 1800 400 55 350-50 88 2584 757 242.79 20VPS400 2000 400 55 350-50 88 2871 841 255.69 12VPH400 1200 400 55-77 350-50 89-111 3784 1108 240.30 14VPH400 1400 400 55-77 350-50 89-111 4380 1282 280.34 16VPH400 1600 400 55-77 350-50 89-111 5005 1465 316.10 18VPH400 1800 400 55-77 350-50 89-111 5631 1648 351.26 20VPH400 2000 400 55-77 350-50 89-111 6257 1832 374.86 12VPS500 1200 500 55 450-50 88 2176 637 195.09 14VPS500 1400 500 55 450-50 88 2512 735 227.61 16VPS500 1600 500 55 450-50 88 2871 841 255.86 18VPS500 1800 500 55 450-50 88 3230 946 281.49 20VPS500 2000 500 55 450-50 88 3589 1051 304.27 12VPH500 1200 500 55-77 450-50 89-111 4730 1385 280.11 14VPH500 1400 500 55-77 450-50 89-111 5474 1603 326.80 16VPH500 1600 500 55-77 450-50 89-111 6257 1832 369.16 18VPH500 1800 500 55-77 450-50 89-111 7039 2060 407.91 20VPH500 2000 500 55-77 450-50 89-111 7821 2289 443.34 12VPS600 1200 600 55 550-50 88 2612 765 224.15 14VPS600 1400 600 55 550-50 88 3015 883 261.51 16VPS600 1600 600 55 550-50 88 3446 1009 336.47 18VPS600 1800 600 55 550-50 88 3876 1135 348.35 20VPS600 2000 600 55 550-50 88 4307 1261 354.09 12VPH600 1200 600 55-77 550-50 89-111 5676 1662 322.74 14VPH600 1400 600 55-77 550-50 89-111 6569 1923 376.54 16VPH600 1600 600 55-77 550-50 89-111 7508 2198 426.10 18VPH600 1800 600 55-77 550-50 89-111 8446 2473 475.34 20VPH600 2000 600 55-77 550-50 89-111 9385 2747 517.04 12VPS700 1200 700 55 650-50 88 3047 892 257.64 14VPS700 1400 700 55 650-50 88 3517 1030 300.58 16VPS700 1600 700 55 650-50 88 4020 1177 339.36 18VPS700 1800 700 55 650-50 88 4522 1324 377.72 20VPS700 2000 700 55 650-50 88 5025 1471 422.20 12VPH700 1200 700 55-77 650-50 89-111 6622 1938 370.91 14VPH700 1400 700 55-77 650-50 89-111 7664 2244 432.73 16VPH700 1600 700 55-77 650-50 89-111 8759 2564 490.57 18VPH700 1800 700 55-77 650-50 89-111 9854 2885 547.68 20VPH700 2000 700 55-77 650-50 89-111 10949 3205 596.31 (prices shown exclude VAT) p. 41

Height inches Height mm Watts Btu planal vertical single-vps 47.2 56.1 63.0 70.9 78.7 1200 1400 1600 1800 2000 1596 1842 2108 2371 2634 5454 6293 7200 8099 8998 REF. HEAT OUTPUTS TO EN442 = T 60C - PER METER LENGTH: PLANAL VERTICAL SINGLE - VPS FRONT VIEW REAR REAR VIEW planal vertical single plus-vph 47.2 56.1 63.0 70.9 78.7 1200 1400 1600 1800 2000 3471 4018 4566 5163 5737 11858 13724 15599 17636 19597 REF. HEAT OUTPUTS TO EN442 = T 60C - PER METER LENGTH: CONCEALED WALL BRACKETS PLANAL VERTICAL SINGLE PLUS - VPH FRONT VIEW REAR REAR VIEW 1035 32 20 40 962 85 962 1087 22 44 8 1067 12 10 YEAR GUARANTEE: each radiator is individually tested and supplied complete with a 10 year guarantee against and defects caused by faulty materials and manufacture. All radiators are tested to 13 Bars before despatch to guarantee a working pressure of 10 Bars. QUALITY: all radiators are manufactured under BS EN ISO 9000 quality system accepted by BSI. MATERIAL: conform to BS1449, Part 1 and are manufactured from 1.20mm cold rolled steel. INSTALLATION: each radiator is supplied with concealed brackets, 1/2 self jointing air-vents and plugs in the protective heavy duty packaging. For maximum efficiency radiators should be fixed at not outside the measurements given on the drawings herein from finished floor level. Bottom opposite end connections pipe positioning guide for manual valve allow 35mm to centre of pipe. For TRV valve allow 45mm to centre of pipe. To prevent damage to radiator it is strongly recommended during installation to leave protective packaging on radiator by simply removing lug protectors and pre-cut tapping connection. FINISH: each radiator is degreased and finished by being electrostatically powder coated with epoxy polyester stove enamel after an application of water based primer. Thereafter they are oven baked to provide outstanding surface which requires no further painting to a high gloss finish in white enamel (RAL 9016) WATER TREATMENT: on completion of the installation the system should be properly flushed and filled in accordance with the British Standard Code of Practice for the Treatment of Water in Domestic Hot Water Central Heating System BS7593 IMPORTANT Please read the following points carefully before installing your ultraheat radiator: DO make sure that you have a good design and layout of your central heating system as this will ensure satisfactory functioning of the system in general and the radiators in particular. DO vent your system properly. Leaks and corrosion problems are usually due to excess air getting into the system. DO pay attention that the drain points are really at the lowest points in the system. DO make absolutely certain that the system is thoroughly flushed before it is commissioned. Rinse out all metal, flux and other foreign residues, the cause of pin-holing. DO avoid over pumping the system, which causes negative pressure aeration, one of the most common causes of corrosion. DO add an approved chemical inhibitor as an additional safeguard, but remember that it is no substitute for good installation practice. DO observe the above basic rules. Not only will you protect guarantee, but you will have years of trouble-free service from your radiators. - DUE TO POLICY OF CONTINUED IMPROVEMENT IN BOTH DESIGN AND PERFORMANCE OF THE PRODUCTS, THE RIGHT IS RESERVED TO ALTER ANY DETAILS CONTAINED IN THIS BROCHURE WITHOUT NOTIFICATION. - VPH IS SUPPLIED WITH TOP GRILL SIDE PANELS WHERE VPS IS JUST THE PANEL WITH NO TOP GRILL AND SIDE PANELS. -APPROVED AND REGISTERED ACCORDING TO DIN - NF AND ALSO CONFIRM TO ISO AND BS EN 442. - ALL ULTRAHEAT RADIATORS ARE MANUFACTURED UN DER A BS EN ISO 9002 : 1994 QUALITY AYATEM APPROVED BY BSI. - ALL PRICES ARE SUBJECT TO VAT. p. 42 (prices shown exclude VAT)