Analysis Report

Similar documents
Analysis Report

Vescom bv Sint-Jozefstraat AV Deurne Nederland

Analysis Report

BCTC CARPET TECHNICAL CENTRE

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

BS EN ISO : 2010

Report VNLF Test Report

TFI Report Reaction to fire test

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS EN ISO : 2010

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

TFI Report Classification

BS EN ISO : 2010

~~oeti. Report VN71 O Classification Report. Reference

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Test Report: ICL/CR15/11/087

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

~,oeti. Report VN Classification Report. Reference

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

New European Fire Testing Classification for Construction Products

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

CE TYPE EXAMINATION CERTIFICATE

Reaction to fire classification report No C-rev.1

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Additional reaction to fire classification report No H

Reaction to fire classification report No C

MEDIUM-DENSITY HOUSING # 7. Fire safety

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Test Report: ICL/H18/9039 Rev 1

Fire Testing of Foams

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

Classification of Fire Performance of Wall and Ceiling Lining Materials

IMO Resolution MSC 61(67): Annex 1: Part 2

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

TFI Report Classification

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

Fire Protection Scover

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Centrum stavebního inženýrství a.s.

Report Classification Report on Burning Behaviour

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

FIRST-CLASS IN TRAINS

Report on First Revision June 2014 NFPA 101

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Report VNNF Test Report

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

CLASSIFICATION REPORT

TEST REPORT DATE: TEST NUMBER: DESCRIPTION OF TEST SAMPLE

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

FRANCE M & F RANKING ACCORDING TO NF F

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

Report on Public Input June 2014 NFPA 101

CERTIFICATE OF APPROVAL No ME 5085

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

~ 0."0... DESCRI PT ION OF TEST SAM PLE

Additional Reaction to Fire Classification Report

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Centrum stavebního inženýrství a.s.

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

Review Fire Test Report

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Classification report

Annex of the certificate (Page 1/5) Accreditation Scope

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

Fire Safety Fire Resistant Building Components

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

Centexbel. General certification regulations. Construction products

Benefiting Government, Industry and the Public Through Innovative Science and Technology. Barry L. Badders, Jr. P.E.

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

SHAW CONTRACT DESCRIPTION OF TEST SAMPLE

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

Fire Retardant Textile Coatings Requirements, Challenges, Solutions. ECC on fire retardant coatings 13&14/03/ Berlin

Copy of article submitted to Fire Safety Engineering for publication January/February 2009

First Revision No. 6-NFPA [ Section No. 2.2 ]

Contact person Date Reference Page Richard Johansson P (2) Fire Research

Annex to the Accreditation Certificate PL according to DIN EN ISO/IEC 17025:2005

Materials Testing by Gregory Havel

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

Report Test Report

ISO 2685 INTERNATIONAL STANDARD. Aircraft Environmental test procedure for airborne equipment Resistance to fire in designated fire zones

Fire Test Methods ASTM NFPA UL ISO IEC

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

CATALYST INSPIRATIONAL TUFTED CARPET COLLECTION

Transcription:

Forbo Flooring Coral nv Dhr. Jan van Galen Postbus 17 1560 AA KROMMENIE Nederland Your notice of Your reference Date 08-02-2016 23-02-2016 Analysis Report 16.00634.08 Required tests : Identification number T1602405 Information given by the client Coral Welcome 3200 Date of receipt 08-02-2016 Kristina De Temmerman Order responsible This report runs to 6 pages and may be reproduced, as long as it is presented in its entire form, without written permission of Centexbel. The results of the analysis cover the received samples. Centexbel is not responsible for the representativeness of the samples. In assessing compliance with the specifications, we did not take into account the uncertainty on the test results. CENTEXBEL textile competence centre www.centexbel.be www.vkc.be Inrichting erkend bij toepassing van de besluitwet van 30-01-1947 Établissement reconnu par application de l'arrêté-loi du 30-01-1947 GENT Technologiepark 7 BE-9052 Zwijnaarde, Belgium phone +32 9 220 41 51 fax +32 9 220 49 55 gent@centexbel.be GRÂCE-HOLLOGNE Rue du Travail 5 BE-4460 Grâce-Hollogne, Belgium phone +32 4 296 82 00 g-h@centexbel.be KORTRIJK Etienne Sabbelaan 49 BE-8500 Kortrijk, Belgium phone +32 56 281828 fax +32 56 281830 info@vkc.be VAT BE 0459.218.289 IBAN BE44 2100 4729 6545 BIC GEBABEBB

Page 2/6 Reference: T1602405 - Coral Welcome 3200 Information given by the client Product standard Production batch/piece number Date of carpet finishing FR treated FR-surface treatment Type of manufacture Use-surface Substrate, support Backing layer Total mass Pile thickness Total thickness Surface structure 18585 01-02-2016 yes no Tufted PA 6 Fibre fleece PES Vinyl 3900 g/m² 5.7 mm 8.5 mm Cut pile Notified body No: 0493

Page 3/6 Reference: T1602405 - Coral Welcome 3200 Reaction to fire tests Ignitability of building products subjected to direct impingement of flame - Single-flame source test Product standard Classification of textile floor coverings in accordance with EN 14041 (2004) 4.1.4 The textile floor coverings listed in Table 2, in the end uses identified in the table, are classified without further testing (CWFT) in the classes shown and do not require testing in respect of these end uses and classes. Table 2 Classes of reaction to fire for textile floor coverings, classified without further testing Floor covering type 1 EN product standard Class 3 Floorings Non-FR machine-made wall-to-wall carpets and pile carpet tiles 2 EN 1307 Efl Non-FR needled textile floor coverings without pile 2 EN 1470 Efl Non-FR needled textile floor coverings with pile 2 EN 13297 Efl 1) Floor covering glued or loose laid over a Class A2-s1,d0 substrate 2) Textile floor coverings having a total mass of max. 4.8 kg/m², a minimum pile thickness of 1,8 mm (ISO 1766) and - a surface of 100% wool - a surface of 80% wool or more 20% polyamide or less - a surface of 80% wool or more 20% polyamide/polyester or less - a surface of 100% polyamide - a surface of 100% polypropylene and if with SBR-foam backing, a total mass of > 0.780 kg/m². All polypropylene carpets with other foam backings are excluded. 3) Class as provided for in Table 2 in the Annex to Decision 2000/147/EC. Classification Class Efl

Page 4/6 Reference: T1602405 - Coral Welcome 3200 Reaction to fire tests for floorings - Determination of the burning behaviour using a radiant heat source Date of ending the test Standard used Product standard Deviation from the standard Conditioning 22-02-2016 EN ISO 9239-1 (2010) - 23 C, relative humidity 50% Minimum 14 days or until constant mass is achieved The test results relate to the behaviour of the test specimens of a product under the particular conditions of the test: they are not intended to be the sole criterion for assessing the potential fire hazard of the product in use. Test specimen Substrate Mounting Cleaning Fibre cement board - density (1800 ± 200) kg/m³ Stuck down with Eurocol 540 Specimens have not been cleaned

Radiant heat flux Flame spread distance (cm) Width Length #2 #3 Average 10 min < 20 min < 17 14 30 min < 19 14 Flame time 12 min 35 s 23 min 45 s 12 min 35 s 13 min 15 s Analysis Report 16.00634.08 Page 5/6 Heat flux * kw/m².0 9.6 10.8 10.4 10.3 * Heat flux at the time of flame extinguishment or after a test duration of 30 minutes. Fire classification in accordance with Class EN ISO 925-2 or CWFT EN ISO 9239-1 (test duration = 30 min) Bfl Efl heat flux 8,0 kw/m² Cfl Efl heat flux 4,5 kw/m² Dfl Efl heat flux 3,0 kw/m² Smoke production: Light attenuation Maximum (%) Width Length 14 #2 13 #3 21 Average Total (%.min) 45 81 59 88 76 Additional classification in accordance with smoke production 750%.min s1 smoke production > 750%.min s2

Page 6/6 Reaction to fire classification : Bfl / s1 Glued on a non-combustible substrate* * End use substrates of classes A1 or A2-s1,d0 (ISO 13238:2010 5.2.2) Limitations This classification document does not represent type approval or certification of the product. Performed under accreditation in the fire lab under the responsibility of Nathan De Kock