IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Similar documents
IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

IR25 Dual Gas Series Datasheet

IR15 Dual Gas Series Datasheet

Lamp Supply (Recommended)

IR1 Single Gas Series Datasheet

VQ500 Series Combustible Gas Detector Elements

IRceL CH4 Methane (CH 4

Technical data sheet TDS0060

PREMIER PLATINUM INFRARED GAS SENSOR

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Technical data sheet TDS0034

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

MICROpeL 75 Combustible Gas Sensor Part Number: PM

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions ***

Integrated IR Datasheet

VQ600 Series Combustible Gas Sensing Head

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Dräger PIR 3000 Detection of flammable gases and vapours

ALTAIR 5X Multigas Detector Product Specification

P R O D U C T D ATA S H E E T

Key Features. General Description

GasAlertMicroClip X3 Specifications

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron 5700 IR Detection of flammable gases and vapours

4) Intrinsic Safety Certification

Approvals, Certificates and Conditions

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

IECEx Certificate of Conform ity

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Dräger Polytron Pulsar 2 Open Path Gas Detector

OLC(T) 100 FIXED GAS DETECTOR

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger X-am 7000 Multi-Gas Detection

Dräger X-am 5000 Multi-Gas Detection

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Dräger PIR 7200 Toxic Gas Detection Transmitter

Inductive slot sensor

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Dräger Polytron 7000 Fixed gas detector

SIL 2. Ultima X Series Gas Monitors CERTIFIED

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

OPTIBAR DP 7060 Supplementary Instructions

SIMRAD GD10 IR GAS DETECTOR

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

ALTAIR 5X Multigas Detector

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Dräger X-am 5000 Multi-Gas Detection

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

3M Oldham OLCT 100. Description. Fixed Gas Detector

Model 144H. Product Data Sheet , Rev DB February Content

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Dräger Polytron 8700 IR Detection of flammable gases and vapors

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Technical Data. Dimensions

Model 144H. Product Data Sheet , Rev DB February Content

IECEx Certificate of Conformity

Rosemount 3490 Series

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

IECEx Certificate of Conformity

Technical Data. Dimensions

SIMRAD GD10PE IR GAS DETECTOR

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Dräger Flame 2500 Flame Detection

Safe Operation Manual. Honeywell IQ Force Gas Detector

Dräger Polytron 5720 IR Toxic Gas Detection

-smartgas- A new low cost infrared gas sensor for domestic and automotive applications

Annubar Flowmeter Series

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

VENTIS PRO SERIES. Product Guide

Dräger X-am 2500 Multi-Gas Detection

Certificate of Compliance

Model D12-IR. Digital Gas Transmitter...

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

Beamex Calibration White Paper. Calibration in hazardous areas

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Technical Data. General specifications. Rated operating distance s n 5 mm

VERSAFLOW VORTEX Supplementary instructions

User s Manual YTA610 and YTA710 NEPSI Certification

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8310 Stationary gas detector (DSIR)

Certificate of Compliance

Transcription:

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining FEATURES * Configured for carbon dioxide (IR11BD, IR21BD), hydrocarbons (,,, ) or acetylene (IR14BD) * Sensing ranges: 2% vol. (optional 5% vol.) for CO 2, 1% LFL (optional 1% vol.) for hydrocarbons * Diffused gas sampling via mesh * Low power * Reference channel for self-compensation * Special gold plated optical/gas cavity for stable signal levels * Operational in varying ambients of temperature, pressure and humidity * Fast response * Rugged stainless steel construction * No moving parts * Resistance to corrosion * Series 4 size to complement miniature catalytic and electrochemical gas sensors * Immunity from poisoning * Reliable fail-safe operation * Low maintenance * Suitable for fixed or portable instrumentation * Series expandable to other gases or vapours * ATEX certified II 2G Ex d IIC Gb (IR1xxx Series) (T a = 72 to +55 8C) * ATEX certified I M1 Ex ia I Ma (IR2xxx Series) (T a = 72 to +6 8C) * IECEx certified Ex d IIC Gb (IR1xxx Series) (T a = 72 to +55 8C) * IECEx certified Ex ia I Ma (IR2xxx Series) (T a = 72 to +6 8C) * CSA certified File 17498 (IR1xxx Series) * UL recognised File E18643 (IR1xxx Series) DESCRIPTION The IR1xxx and IR2xxx Series 1 sensors use the proven nondispersive infrared (NDIR) principle to detect and monitor the presence of gases. With an infrared source and specific filtering on the pyroelectric detectors mounted inside the optical/gas cavity, individual gases or types of gas can be identified and their concentrations determined. (Photograph shows device approximately 2 1 / 2 x actual size) The IR1xxx Series 1 are suitable for reliable monitoring of gas levels in general safety applications where the infrared sensor size is restricted and requires flameproof/explosion-proof certification. The IR11BD is filtered specifically for carbon dioxide, whereas the and are cross-sensitive to a range of hydrocarbons. The covers the wider range but has a slight response to water vapour when the RH is high. The is filtered to a narrower waveband, more specific to methane and shows less response to the water levels typically found in mining applications. The IR14BD is narrowly filtered for acetylene, but has some response to water due to the close proximity of the water absorption bands. For more information, refer to Infrared Gas Sensor Application Note 1. The IR2xxx Series 1 share the same build standard as the IR1xxx Series 1, but are labelled as being intrinsically safe for methane monitoring in mining applications. OPERATION To operate as NDIR gas sensors, the IR1xxx and IR2xxx Series 1 must be interfaced to a suitable transmitter for power supply and for amplifying and processing signals. Sensor outputs require linearisation and compensation for ambient temperature variation (facilitated by the inbuilt thermistor) by algorithms in the system software. This is necessary for sensors to meet their full performance specification. A temperature sensor must be included in the electronics and be positioned close to the gas sensor. Compensation for pressure changes can also be made in an algorithm, provided there is a suitable input from a pressure sensor. SGX Sensortech(IS) Ltd Registered in England No.86777 A1A-IR1xxx_IR2xxx_Ser_1 Version 3, July 29

A set of Application Notes is available from the e2v technologies website, to explain more about NDIR gas sensing and provide advice for the end-user on interfacing sensors and processing signals. Infrared Sensor Application Note 1: Background to NDIR Gas Sensing Infrared Sensor Application Note 2: Signal Processing Infrared Sensor Application Note 3: Software Design Infrared Sensor Application Note 4: Electronics Design Infrared Sensor Application Note 5: Determining Coefficients for Linearisation and Temperature Compensation Infrared Sensor Application Note 6: Advice for Using Infrared Gas Sensors in Mining Applications CERTIFICATIONS IR1xxx Series 1 SIRA Certification Services, EU Notified Body No. 518, have certified the IR1xxx Series 1 under the ATEX Directive, 94/9/ EC, and the IECEx Scheme. Certificate number SIRA 99ATEX1121U certifies it as a flameproof component to EN679-:26 (including amendments A1 and A2) and EN679-1:27. Instructions specific to hazardous area installations apply. See page 5. Certificate number IECEx SIR 4.31U certifies it as a flameproof component to IEC679- Ed. 5 and IEC679-1 Ed. 6. The Canadian Standards Association has issued a component certification for the IR1xxx Series 1 for use as part of an intrinsically safe portable combustible gas detector or housed in a remote sensor housing. It has satisfied the requirements of CSA standard C22.2 No. 3-M 1986. File No. 17498. Underwriters Laboratories Inc. recognise the IR1xxx Series 1 as components in intrinsically safe single- or multi-gas detectors for use in Class 1, Division 1, Groups A, B, C and D hazardous locations. It has satisfied the requirements of UL913, fifth edition. File E18643. IR2xxx Series 1 SIRA Certification Services, EU Notified Body No. 518, have certified the IR2xxx Series 1 under the ATEX Directive, 94/9/ EC, and the IECEx Scheme. Certificate number SIRA 2ATEX215U certifies it as an intrinsically safe component for mining applications, category M1, to EN679-:26 (including amendments A1 and A2), EN679-11:27 and EN533:2. Instructions specific to hazardous area installations apply. See page 5. Certificate number IECEx SIR 3.3U certifies it as a flameproof component to IEC679- Ed. 5 and IEC679-11 Ed. 5. FRACTIONAL ABSORBANCE CURVES These show the sensitivity versus concentration before linearisation for the range of gases. For further explanation, refer to the Infrared Sensor Application Notes. Typical Sensitivity to to 2% vol. Carbon Dioxide (IR11BD, IR21BD).4.3.2.1 781A.5 1. 1.5 2. CO 2 CONCENTRATION (% vol.) Typical Sensitivity to Methane (1% LFL = 5% vol.) (,,, ).12.1.8.6.4.2 1 2 3 4 5 CH 4 CONCENTRATION (% vol.) 8312 HANDLING PRECAUTIONS 1. Do not allow sensors to fall on the floor. This could cause lamp filament breakage, damage to the pins and the gas entrance aperture. 2. Do not apply mechanical force against the gas entrance aperture. 3. Do not immerse sensors in water or other fluids. 4. Protect the gas entrance aperture against dust ingress and sprayed materials. 5. Anti-static handling precautions must be taken. 6. Under no circumstances should the sensor pins be soldered directly to a pcb or wires. Excessive heat could cause irrepairable damage to the pyroelectric detectors. SGX Sensortech(IS) Ltd Registered in England No.86777 A1A-IR1xxx_IR2xxx_Ser_1 Version 3, July 29

Typical Sensitivity to Ethylene (1% LFL = 3% vol.) (,,, ) Typical Sensitivity to Benzene (1% LFL = 1.5% vol.) (, ).25 7944B.1 7945A.2.8.15.1.5.15.3.45.6.75 C 2 H 4 CONCENTRATION (% vol.).6.4.2.3.6.9 1.2 1.5 C 6 H 6 CONCENTRATION (% vol.) Typical Sensitivity to Acetylene (1% LFL = 2.5% vol.) (IR14BD) Typical Sensitivity to Propane (1% LFL = 2.4% vol.) (,,, ).14.12 82B.12.1.8.6.4.2 7952B.24.48.72 C 3 H 8 CONCENTRATION (% vol.).1.8.6.4.2.5 1. 1.5 2. 2.5 C 2 H 2 CONCENTRATION (% vol.) Note Other Fractional Absorbance curves are available from Gas Sensor Engineering at SGX Sensortech. SGX Sensortech(IS) Ltd Registered in England No.86777 A1A-IR1xxx_IR2xxx_Ser_1 Version 3, July 29

TECHNICAL SPECIFICATION Mechanical Dimensions see outline, page 5 Body material Weight Environmental stainless steel 27 g Ambient temperature range: for operation for storage Operational pressure range Humidity range for operation and storage Vibration Ingress protection 72 to +55 8C 725 to +85 8C 7 to 13 hpa to 95% non-condensing complies with EN61779-1 requires extra protection depending on application Electrical DC supply to detectors +3 to +15 V; +5 V recommended Maximum power supply Lamp supply Warm-up time 18 mw 3 to 5 V (6 ma), modulation 4 Hz, 5% duty cycle recommended Note: Applying 45 V will reduce the lamp lifetime 52 s to operate, 53 min. to full specification at 2 8C PERFORMANCE All measurement data taken using: SGX linearisation and temperature compensation algorithms; see Infrared Sensor Application Notes. Lamp modulation.4 5. V, square wave, at 4 Hz and 5% duty cycle. Ambient temperature (2 8C) and pressure (11 hpa). All gases diluted in nitrogen. Note: Any variation from these conditions may affect sensor performance. Sensor type IR11BD, IR21BD,, IR14BD Gas Carbon Dioxide Hydrocarbons Hydrocarbons Acetylene Sensing range Maximum response time (T9) Limits of detector output voltage in nitrogen (x 165 pre-amplifier gain): active channel reference channel Typical % fall in active detector voltage for exposure to stated target gas (reference detector is unchanged) Maximum deviation from linearity 3 ppm 2.% vol. 5.%vol. 1.5 to 3.8 V 32% for 2.% vol. conc. carbon dioxide 1% LFL 1% vol. 1.8 to 6. V 9.5% for 5% vol. conc. methane 52 s +.1% vol. 1% LFL 1% vol. 3.3 to 8.2 V 11% for 5% vol. conc. methane Maximum variation of zero from 72 to +55 8C +1 ppm/8c +2 ppm/8c Resolution (dependent on electronics) 1 ppm 5 ppm Maximum non-reproducibility of zero at 2 8C +1 ppm +5 ppm Maximum non-reproducibility of sensitivity at 2 8C +2 ppm +1 ppm Long-term zero drift/month at 2 8C +1 ppm +5 ppm Response to 9% change in RH at 2 8C (in target gas) MTBF (lamp dependent only) % vol. (in 2% vol.) +.1% vol. (2.5% vol.) +.3% vol. (2.5% vol.) 41 years for 5 V operation, 42 years for 3 V operation 1% LFL 1% vol. 1.5 to 4. V 12.5% for 2.3% vol. conc. acetylene +.5% vol. (2.3% vol.) SGX Sensortech(IS) Ltd Registered in England No.86777 A1A-IR1xxx_IR2xxx_Ser_1 Version 3, July 29

OUTLINE (All dimensions in millimetres; see note 1) 5. 5. +.6 19. 113.8 7811D 4. 3 5 8. 2 1 4 6 11.5 +.5 1. CHAMFER.2 x 458 12. (EXCLUDING LABEL) Pin Connection 1 + V DC detector supply 2 Lamp 3 Lamp return 4 Active detector output 5 Reference detector output 6 V input Outline Notes 1. Body dimensional tolerances +.1 mm. Pin dimensional tolerances as indicated. 2. IR1xxx Series 1 and IR2xxx Series 1 sensors are designed to press-fit into pcb sockets. The end-user should choose a socket to accommodate the full sensor pin length. This will ensure a stable mechanical location as well as good electrical contact. e2v technologies recommend the Wearns Cambion type 45-1813-1-3- single-pole solder mount socket with through hole, or a suitable equivalent. INSTRUCTIONS SPECIFIC TO HAZARDOUS AREA INSTALLATIONS (Ref. EU ATEX Directive 94/9/EC, Annex II, 1..6) 1. The IR1xxx Series 1 and IR2xxx Series 1 Gas Sensing Heads are component-approved only and may not be used as stand-alone items in a hazardous area without further protection. 2. The IR1xxx Series 1 and IR2xxx Series 1 Gas Sensing Heads shall be protected in service. The Sensing Head shall be mounted in a protective enclosure such that an impact of 7 J in accordance with EN679-:26 clause 23.4.3.1 from any direction shall not cause the impact head to make contact with the Sensing Head. 3. The thermal resistance of the IR1xxx Series 1 and IR2xxx Series 1 Gas Sensing Heads does not exceed 25 K/W; this shall be taken into account when considering its surface temperature and the temperature classification of the equipment into which it is to be incorporated. 4. The IR1xxx Series 1 and IR2xxx Series 1 Gas Sensing Heads have not been assessed as a safety device (EHSR 1.5). 5. There are no user-serviceable parts in the component. 6. The end-user/installer shall be aware that the certification of the IR1xxx Series 1 and IR2xxx Series 1 Gas Sensing Heads relies on the following materials used in its construction, which are suitable for most common applications: Enclosure................ Stainless steel Mesh.................. Stainless steel Bushing................. Epoxy resin In accordance with the Note in EN679-:26 clause 6.1(a), the end-user/installer shall inform the manufacturer of any adverse conditions that the IR1xxx Series 1 and IR2xxx Series 1 Gas Sensing Heads may encounter. This is to ensure that the IR1xxx Series 1 and IR2xxx Series 1 Gas Sensing Heads are not subjected to conditions that may cause degradation of these materials. 7. The IR1xxx Series 1 Gas Sensing Head is only certified for use in ambient temperatures between 72 and +55 8C and should not be used outside this range. 8. The IR2xxx Series 1 Gas Sensing Head is only certified for use in ambient temperatures between 72 and +6 8C and should not be used outside this range. 9. The maximum input power of the IR1xxx Series 1 Gas Sensing Head shall not exceed 2.5 W. 1. The IR2xxx Series 1 is a galvanically isolating device with infallible separations between the lamp and detector circuits up to 1 V. The IR2xxx Series 1 has the following safety description: Lamp Circuit:............. U i = 7.2 V Detector Circuit:........... U i = 1 V Lamp + Detector Circuits.... P i = 2.71 W 11. The IR2xxx Series 1 Head is dust-proof (IP5x) but offers no protection against the ingress of water. Where protection in excess of IP5 is required, the apparatus into which the IR Head is installed shall provide the necessary ingress protection. SGX Sensortech(IS) Ltd Registered in England No.86777 A1A-IR1xxx_IR2xxx_Ser_1 Version 3, July 29