Model KBF 240 Constant climate chambers with large temperature / humidity range

Similar documents
Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Model KBWF 720 Growth chambers with light and humidity

Model KBWF 240 Growth chambers with light and humidity

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model C 170 CO 2 incubators with hot air sterilization

Constant climate chambers

Constant climate chambers

Constant climate chambers

Constant climate chamber with humidity

Constant climate chamber with ICH-compliant illumination

Environmental simulation chamber for complex alternating climate profiles

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Plant growth chambers

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Constant climate chambers

KMF Environmental test chamber for constant climate

Constant climate chambers

Constant climate chambers. Always the right climate KBF KBF P KBF LQC KMF series

Constant climate chambers

Constant climate chambers

New Generation KBF 240 series

Constant climate chambers

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Safety vacuum drying oven for flammable solvents

Drying and heating chambers. Series ED FD FED FP M

Drying and heating chambers

Vacuum drying oven for non-flammable solvents

BINDER Industrial. Product Catalog

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Vacuum drying VD VDL series

Vacuum drying chambers. VD VDL series

ULTRA.GUARD ultra low temperature freezer

CO₂ incubators. C CB series

VD 53 - Vacuum drying oven for non-flammable solvents

BINDER Product catalog

BINDER Scientific Product Catalog

CO₂ incubators. C CB series

www

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

ECOLOG Data logger series we prove it.

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

NEW GENERATION. Efficient use of valuable space INCUBATORS

STABILITY ICH. ICH Stability Tests

Thermo Scientific Heraeus microbiological incubators An optimal environment for your samples

Stability Chambers & Rooms

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

FITOCLIMA 600 & 1200 STABILITY

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

PROTÉGÉ ZM SINGLE GAS MONITOR

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

ZL Laboratory freezers

FITOCLIMA 600 & 1200 STABILITY

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dräger Polytron 7000 Fixed gas detector

Environmental Chambers

FITOCLIMA 600 & 1200 PHARMA

ENVAIR lab CO2 Tri-Gas Incubator

VACUUM HEATING AND DRYING OVENS Gentle and safe

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Thermo Scientific Heraeus Heating and Drying Ovens

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators

Chromatographic Air circulated Refrigerator, two-door TC 603

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

FitoClima / FitoTerm SOL chambers

incubator, the best in its class

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

ICH110. Climate Chamber. Product specification

ICH260C. Climate Chamber. Product specification

Humidity Chambers HCP

ICH750L. Climate Chamber. Product specification

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

OVENS. All our ovens are tested to meet electrical safety standard IEC EN , this standard provides additional security for laboratories.

N-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features:

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

Dräger Polytron 8310 IR Detection of flammable gases and vapour

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

Laboratory Refrigerator/Deep Freezer TC 802

SD-06AG Laboratory Scale Spray Dryer

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

Shop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.

Controlled Environment Equipment Solutions for the Lab

Environmental Chambers Series: reach-in & benchtop capacities

SHAKING WATER BATHS ENGLISH

SAGV x 1/1 GN 7-12 x 20 COMBI STEAMER FOR GASTRONOMY

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

ECOLOG Datalogger Series

Open Liquid Calibration Baths

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

FROILABO offers a full range of incubators with natural convection, air forced or forced cooling to cover most laboratory applications.

Transcription:

Model KBF 240 Constant climate chambers with large temperature / humidity range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic water and wastewater management Pressure humidification with fast response times MAIN FEATURES Model 240 Model 240 Temperature range: 0 C to 70 C Humidity range: 10 % to 80 % RH APT.line preheating chamber technology Humidity regulation with capacitative humidity sensor and vapor humidification Controller with time-segment programming Tightly-sealed inner door made of tempered safety glass 2 stainless steel racks Access port with silicone plug, 30 mm, left 4 stable castors, two with brakes Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm Computer interface: Ethernet Door heating ORDERING INFORMATION Interior volume [L] Voltage Option model Version Art.-No. Model KBF 240 247 200 230 V 1~ 50/60 Hz Standard KBF240-230V 9020-0269 200 240 V 1~ 50/60 Hz Standard KBF240UL-240V 9020-0270 TECHNICAL DATA Description KBF240-230V KBF240UL-240V Article Number 9020-0269 9020-0270 Performance Data Temperature Temperature range [ C] 0 70 0 70 Temperature uniformity at 25 C [± K] 0.2 0.2 Temperature uniformity at 40 C [± K] 0.3 0.3 Temperature fluctuation [± K] 0.1 0.1 Page 1 / 6

Description KBF240-230V KBF240UL-240V Article Number 9020-0269 9020-0270 Max. heat compensation at 40 C [W] 300 300 Recovery time after 30 seconds door open at 25 C and 60 % RH [min] 4 4 Recovery time after 30 seconds door open at 40 C and 75 % RH [min] 5 5 Performance Data Climate Temperature range [ C] 10 70 10 70 Temperature uniformity at 25 C and 60 % RH [± K] 0.3 0.3 Temperature uniformity at 40 C and 75 % RH [± K] 0.3 0.3 Temperature fluctuation at 25 C and 60 % RH [± K] 0.1 0.1 Temperature fluctuation at 40 C and 75 % RH [± K] 0.1 0.1 Humidity range [% RH] 10 80 10 80 Humidity fluctuation at 25 C and 60 % RH 1,5 ± % RH 1,5 ± % RH Humidity fluctuation at 40 C and 75 % RH 1,5 ± % RH 1,5 ± % RH Electrical data Rated Voltage [V] 200 230 200 240 Power frequency [Hz] 50/60 50/60 Nominal power [kw] 2.1 2.1 Phase (Nominal voltage) 1~ 1~ Measures - Outer dimensions Width net [mm] 925 925 Height net [mm] 1460 1460 Depth net [mm] 800 800 Wall clearance back [mm] 100 100 Wall clearance sidewise [mm] 100 100 Steam space volume [L] 348 348 Measures - Doors Inner doors 1 1 Unit doors 1 1 Measures - Internal Dimensions Width [mm] 650 650 Height [mm] 785 785 Depth [mm] 485 485 Measures Interior volume [L] 247 247 Net weight of the unit (empty) [kg] 4 4 Load per rack [kg] 30 30 Environment-specific data Energy consumption at 40 C and 75 % RH 650 Wh/h 650 Wh/h Sound-pressure level [db(a)] 52 52 Page 2 / 6

CHARTS Climate chart OPTIONS AND ACCESSORIES Designation Description * Art.-No. 30 mm, left 01 8012-0648 30 mm, right 01 8012-0647 30 mm, top 01 8012-0649 Access port with silicone plug Alarm output, zerovoltage Analog output, 4 20 ma BINDER Pure Aqua Service BINDER Pure Aqua Service, accessories Calibration certificate, expanded Calibration certificate, temperature Calibration certificate, temperature and humidity Class 3.3 independent temperature safety device 50 mm, left 01 8012-0653 50 mm, right 01 8012-0652 50 mm, top 01 8012-0650 100 mm, left 01 8012-0515 100 mm, right 01 8012-0514 100 mm, top 01 8012-0651 for temperature (±2 C) and humidity (±5 % RH), accessible via 6-pin DIN socket (max. 24 V - 2.5 A), with audible signal that can be switched off 8012-0615 for temperature and humidity values (output not adjustable) 8012-0614 system for preparation or complete desalination of tap water, containing single-use cartridge, hoses and measuring device 8012-0759 Single-use, replacement cartridge for BINDER Pure Aqua System 6011-0165 for temperature and humidity, each additional measurement at additional points or sets of values 8012-0155 temperature measurement incl. certificate and 27 measuring points at specified temperature 8012-0923 temperature measurement incl. certificate, 15- measuring points at specified temperature 8012-0920 temperature measurement incl. certificate, 9 measuring points at specified temperature 8012-0917 for temperature and humidity, measurement in center of chamber at 25 C / 60 % RH or at specified values 8012-0154 temperature (according to DIN12880) and humidity measurement incl. certificate, 27 temperature measuring points and 1 humidity measuring point, at 25 C / 60 % RH or at specified values 8012-0924 with visual alarm (DIN 12880) 8012-0610 * Notes See last page Page 3 / 6

Designation Description * Art.-No. Converter, voltage to operate the device at a nominal voltage of 120 V 1 ph 60 Hz 8009-0821 Data Logger Kit Data Logger Kit, software T 220: temperature logging from -90 C to 220 C 19 8012-0715 TH 70/70: temperature and humidity logging from -40 C to 70 C and 0 % to 100 % RH and additional combination sensor for recording environmental conditions 19 8012-0717 TH 70: temperature and humidity logging from -40 C to 70 C and 0 % to 100 % RH 19 8012-0716 LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) 19 8012-0821 Door lock lockable door handle 8012-0584 RS232/RS422-115V RS232/RS422-230V RS422-230V USB / RS422 RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit 120 V, 60 Hz option model 8012-0557 RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit 230 V, 50/60 Hz option model 8012-0556 RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit 230 V, 50/60 Hz option model 8012-0380 RS 422 cable set and RS 422 / USB interface converter for connection to 10-way plug distributor or for connection to a unit (USB-powered converter) 8012-0665 Interior lighting 230 V, 15 W option model 02 8012-0116 Interior socket coverable, with associated LEMO connector (nominal voltage, max. 500 W, max. 90 C, protection class IP67) 07 8012-0640 Lockable controller keyboard Lockable controller keyboard with key-operated switch 8012-0609 Magnetic Pouch (A4) insert pouch with magnetic strip 1007-0065 ph-neutral detergent concentrated, for gentle remove of residual contaminants; 1 kg 1002-0016 Pt 100 temperature sensor additional Pt 100, with flexible cable installed with external connection, incl. 6-pin DIN socket 8012-0637 Rack stainless steel 6004-0101 Rack, accessories set of 4 fasteners for additional security 8012-0620 Rack, reinforced stainless steel, with 1 set of 4 fasteners, max. load 70 kg 8012-0638 RS 422 interface RS 422 interface, cable (15 m) RS 422 interface, cable (50 m) in place of Ethernet, for communication software 8012-0641 modular plug distributor for 10 RS 422 interfaces 8012-0295 RS 422 connection cable (15 m) between plug distributor and RS 422 interface 5023-0036 RS 422 extension cable (50 m) between interface converter and unit or RS 232 / RS 422 plug distributor 5023-0117 Shelf, perforated stainless steel 6004-0040 Shelf, reinforced Software positioned at bottom level, max. load 67 kg, with additional attachment for operation of shaking device, stirring device or roller bottle system APT-COM communications software 8012-0639 version 2 to 3, GLP edition 19 9053-0016 version 3, BASIC edition 19 9053-0014 version 3, GLP edition 19 9053-0015 version 3, STANDARD edition 19 9053-0013 APT-COM communications software, price: for free version 3, GLP DEMO Edition 19 9053-0008 Water supply set external, consisting of fresh- and waste-water containers (20 liters each), cabling and pump 8012-0643 * Notes See last page Page 4 / 6

SERVICES Designation Description * Art.-No. Installation services Installation and set up of unit at operating location, connect to existing connections 13, DL100300 Instruction unit function instructions for operation and programming of the controller DL100700 Preventive maintenance Preventive maintenance Execution of equipment inspection according to maintenance plan 14, DL200400 Calibration services Calibration temperature and humidity including certificate, one measuring point in center of chamber at 25 C / 60 % RH or at specified values DL300301 Temperature and humidity measurement according to DIN12880 including certificate (27 temperature measuring points and 1 humidity measuring point, at 25 C / 60 % RH or at specified values) DL300427 Temperature measurement temperature measuring points and 1 humidity measuring point including certificate, temperature measuring points and 1 humidity measuring point in center of chamber, at 25 C / 60 % RH or at specified values DL3003 Temperature measurement 27 temperature measuring points and 1 humidity measuring point including certificate, 27 temperature measuring points and 1 humidity measuring point in center of chamber, at 25 C / 60 % RH or at specified values DL300327 Temperature measurement 9 temperature measuring points and 1 humidity measuring point including certificate, 9 temperature measuring points and 1 humidity measuring point in center of chamber, at 25 C / 60 % RH or at specified values DL300309 Validation services Execution of IQ/OQ in accordance with qualification folder 15,, 20 DL420300 Execution of IQ/OQ/PQ in accordance with customer's requirement, price: on request 15, DL440500 Qualification folder IQ/OQ Qualification folder IQ/OQ/PQ * Notes See last page supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ 15,, 20 8012-0867 15, 8012-0955 Page 5 / 6

NOTES 01 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge. 02 UL mark is not granted when this option is used. 03 Heat resistant only to max. 200 C. 04 Only available on units rated for 230 V. 05 Attention: The pump is delivered separately. The electric connection for the pump (230 V/1~/50 Hz) must be carried out by an authorized electrician. 06 Heating-up time may increase as a result of the lower heat conductivity. 07 The additional heat input may affect the temperature behavior. 08 The pump (packaged separately) is ready for connection. 09 Not in conjunction with the optional access port, door with window and interior lighting. 10 Not available on 23-liter units. 11 Not available on 23- or 53-liter units. 12 Only available on units rated for 230 V or 400 V. 13 Installation and connections take place at unit location; transport within the company only upon consultation. 14 We recommend a BINDER service contract (see the chapter on BINDER Service) to cover unit inspections, calibrations and validations. 15 OQ according to Yellow Paper = completed factory validation documentation of all OQ checklists. 16 Sensor calibration is performed in an accredited calibration laboratory. 17 Calibration is performed according to the BINDER factory standard. Quoted prices do not include travel costs. Please refer to the chapter on BINDER Service for travel costs for your region. Quoted prices for services performed in Switzerland do not include a country-specific added fee (available on request). 19 For additional accessories, refer to the Process documentation chapter. 20 When ordering IQ/OQ qualification folders and associated IQ/OQ execution on one order, we offer a 15 % discount for both items. When ordering IQ/OQ/PQ qualification folders and associated IQ/OQ/PQ execution on one order, we offer a 15 % discount for the item of the IQ/OQ/PQ folder. 21 ATEX conformity: Pumping chamber (pumped gases): II 2G IIC T3 X Environment with inert purge gas: II 2G IIB T4 X Environment without inert purge gas: II 3G IIB T4 X Motor: II 2G Ex d IIB T4 Gb

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.