NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Similar documents
E3 Series Broadband System

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

E3 Series Broadband System

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

PIER 4 PHASE 2 RECONFIGURATION PROJECT NO CONTRACT NO

Version 1.0. NetSOLO Broadband Fire Alarm / Emergency Voice Evacuation System Engineer/Architect Specification Part No

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

CHABOT-LAS POSITAS COMMUNITY COLLEGE DISTRICT CHABOT COLLEGE BIOLOGICAL SCIENCES B2100 BUILDING ANNEX BID NO

L-Series, Emergency Communication Devices

ECC-50/100C. Emergency Command Center

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100(E) Emergency Command Center

L-Series, Indoor Strobes and Horn Strobes

MT. SAN JACINTO COMMUNITY COLLEGE DISTRICT

July 14, 1999 DF C-100.

SECTION FIRE ALARM SYSTEMS

SUBMITTAL COVER. Akerman-Practicon

June 10, 2002 DF C S2424

E3 Series Expandable Emergency Evacuation Installation/Operating Manual. Document: Print Date: 6/6/07 Rev: C

L-Series, Indoor Strobes and Horn Strobes

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Gamewell-FCI January 11, 2016 Honeywell Fire Systems 12 Clintonville Road Northford, Connecticut Product Guide Specification

FireFinder XLSV Digital Emergency Voice Alarm / Communication System

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

TrueAlarm Fire Alarm Systems

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

NetSOLO Broadband Network Emergency Voice Evacuation System Installation/Operation Manual

Fire Alarm Devices. Drexel Thrash Laborers Training Center. Supplier: Tri S Controls

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

A World of Solutions

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX TM Series Intelligent Fire Alarm & Network System

Intelligent Fire Detection & Alarm and Mass Notification System.

Bosch EVAX System - High-rise Applications

EST3 Installation and Service Manual

Emergency Communications

Product Guide Specification

SP40S-D. Kingfisher Company, inc. Features: Description:

SAFEPATH Mass Notification System (SPMNS)

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

TrueAlarm Fire Alarm Controls

Desigo TM Fire Safety System A comprehensive fire-protection system

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

E3 Series Classic Installation/Operation Manual. Document /15/10 Rev: I P/N :I ECN

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

ADVANCED TECHNOLOGY, FLEXIBILITY, AND BUILT-IN SURVIVABILITY

Addressable Fire Alarm Control Panel

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S :111

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

SAFEPATH DoD facility communications system & expansion options

E3 Series Broadband Emergency Voice Evacuation System Installation/Operation Manual. Document /15/10 Rev: I P/N :I ECN

Desigo TM Fire Safety System A comprehensive fire-protection system

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

Cerberus PRO A comprehensive fire-protection system

i.net Engineered system solutions for

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Fire Control Panels. Addressable Fire Detection and Control Emergency Voice/Alarm Communications Equipment

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM

WINDOW & HVAC REPLACEMENT PEMBERTON TOWNSHIP BOE REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5450E

16 Zone Voice Evacuation VA & PA Sound System

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

TrueAlert Addressable Notification

INTELLIGENT FIRE ALARM CONTROL PANEL

Voice Alarm. Multifunctional Voice Alarm Systems. certified to EN54

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

A. This Section covers fire alarm systems, including initiating devices, notification appliances, controls, and supervisory devices.

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

Inside a typical. Intelligent Voice Communication System. Mounting Diagram. 2 Cerberus PRO. 252 / 504-point Cerberus PRO fire / voice system

1 UL 864 Compliance. 2 Product Overview. Network Communications Module NCM-W/F Product Installation Document. 1.1 Products Subject to AHJ Approval

NETWORK FIRE ALARM CONTROL PANEL. Features

Booster Power Supply Manual

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

Autonomous control unit

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

Pompano Pet Lodge 930 Northwest 31 st Avenue Pompano Beach, FL 33069

FIREFINDER-XLS CONTROL PANEL

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

MPC-6000 / MPC-7000 / RND-2

FIREFINDER-XLS CONTROL PANEL

ARCHITECT AND ENGINEER SPECIFICATIONS

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

FCI INI-7100 Series Fire Alarm Network Version 1.1 Engineer/Architect Specification Modified June 3, 2004 Part No

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Version /17. Honeywell Gamewell-FCI Honeywell Security and Fire 12 Clintonville Road Northford, CT 06472

LifeAlarm Fire Alarm Controls

A World of Solutions

CATALOG NUMBER. Features. Description

Innovative protection that combines power and flexibility

Solutions for Mass Notification Systems

Versatile. VM Mid-range Life Safety Solutions. S e e. w h a t ' s p o s s i b l e n o w..

Rev. B. TrueAlert Addressable Controller Application Manual

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

NETWORK EMERGENCY VOICE EVACUATION SYSTEM

TrueAlert Addressable Notification Appliances

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

Transcription:

Voice Evacuation NetSOLO Broadband Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System General The NetSOLO Broadband is a revolutionary advance in fire detection and emergency voice evacuation system design. NetSOLO Broadband employs the proven technology of the 7100 Series fire alarm control panel and expands it to accomplish emergency multi-channel voice evacuation. It is a true peer-to-peer, token passing, networked system capable of supporting up to sixty-four individual nodes. All systems status, control-by-event sequences, audio voice paging, and fire fighter telephone signals are sent between the nodes over just a single pair of wires or fiber-optic cable. Each NetSOLO Broadband node can be spaced along the network a maximum distance of 3,000 feet (914.4 m) over an unshielded twisted-pair of wires or up to an 8dB loss using fiber-optic cable. Built-in isolation at each node permits Style 4, 6, and 7 network configurations. NetSOLO Broadband NetSOLO Broadband is capable of the most sophisticated sequences of operations. The Field Configuration Program (FCP-NetSOLO) is based on Boolean logic statements providing AND, OR, NOT, and XOR logic operators. These operators can be combined to produce additional Boolean operators such as NAND, NOR, XNOR, etc. A comprehensive set of timing functions can also be attached to any input/output logic statement for staggered reset of fan control relays, time-delayed alarm activation, automatic system silence, etc. FEATURES & BENEFITS IBC Seismic Certified All communication signals and control-byevent sequences transmit over a single pair of twisted unshielded wires or fiber-optic cable Distributed Architecture, including Style 7 wiring configurations allow system components to continue normal operation with no loss of function during single line fault conditions Ideal for a wide range of complex system applications including high-rise or campus installations Integrates 7100 NetSOLO Series fire alarm control panels, transponders and INCC command centers to create a complete audio evacuation system with up to sixty-four nodes Offers a network data transfer rate at 625K baud Graphic Network Annunciator (NGA) (optional) Each INCC supports up to sixteen ASM-16 addressable switch modules for a total of 256 switches in which the software can be programmed separately Remote 48 LED Driver Module (ANU-48) (optional) Redundant command centers with microphone and fire fighter s handset easily configured by adding INCCs State-of-the-art digital signal processor (DSP) technology for efficient audio compression and filtering Softwareprogrammable, multichannel digital audio applications Up to 150 watts of audio power (three AM- 50 Series amplifier modules) with an additional 50 watts of standby power in each intelligent network transponder ( CAB- B) cabinet) Each AM-50 Series amplifier module provides two individually activated speaker circuits supplying 50 watts total of power Sixteen message capacity with up to 3 minute duration per Messages easily fieldconfigurable with a laptop computer Advanced Boolean Logic-based programming such as AND, OR, NOT, NOR, time delay, and calendar functions configurable through computer programming

General The 7100 NetSOLO is a microprocessor-based fire alarm control panel with two analog, addressable signaling line circuits (SLC). Each 7100 is equipped with an Intelligent Network Interface Module for unshielded, twisted-wire and fiber-optic cable (INI-7100 FO). Options include an integral Digital Alarm Communicator Transmitter (DACT) supporting the most popular reporting formats. The Intelligent Network Command Center (INCC) serves as the point of interface between an operator and the system s audio evacuation, fire fighter intercom and building network. The INCC occupies a single address on the NetSOLO Broadband network. A typical INCC assembly consists of the following: An Intelligent Network Interface-Voice Gateway (INIVG) module (fiber-optic or unshielded twistedpair) INI-VGC-UTP (unshielded twisted-pair only) One or more Addressable Switch Modules (ASM-16) Optional Graphic Annunciator (NGA) Remote 48 LED Driver Module (ANU-48) Options include a voice paging microphone and a fire fighter s handset connecting to the INI-VGC. Each INCC can support up to sixteen ASM-16 modules. Each ASM-16 has sixteen push button switches for a maximum capacity of 256 switches per INCC command center. Each switch has three associated LEDs, colored green, yellow, and red. These switches and their LEDs are fully programmable to serve any system function desired. They can control audio speaker circuits, notification appliance circuits, addressable relay outputs, fire fighter phone control circuits. Switches may also be customized for any special application that might be required. Multiple INCCs can be configured into the NetSOLO Broadband network to serve as a completely independent command center for their local area or serve as remote command centers mimicking in part or in whole the function of a main command center. The transponder occupies a single address on the network and provides termination points for the network connection using either a pair of twisted, unshielded wire (12 AWG max.) or fiber-optic cable. The INI-VGX uses advanced Digital Signal Processing (DSP) technology for audio compression and filtering that allows the NetSOLO Broadband to produce the clearest audio possible while conserving the network bandwidth for an instantaneous response. During voice paging and fire fighter communication, background noise is automatically filtered. This feature allows increased audibility and eliminates the need for push-to-talk devices. The INI-VGX can accommodate up to sixteen different messages with a total combined duration of three minutes. Each message can be installed in the field using a laptop computer. Available message options are voice messaging or evacuation tone. The INI-VGX also provides a fire fighter phone riser and addressable signal line circuit that connects to multiple phone jacks or warden stations through as many as sixteen AOM-TELF modules. In addition, the INI-VGX SLC can support up to thirty-two speaker circuits using the AOM-2SF for single channel applications. The CAB-B can contain up to four AM-50 Series amplifiers that produce 50 watts of power @ either 25 V RMS or 70.7 V RMS audio output. Each amplifier includes two separate speaker circuits that can be wired Style Y (Class B) or Style Z (Class A). In addition, each amplifier can broadcast its own tone or message independently of other system amplifiers. Thus, an transponder can produce three audio channels simultaneously. Each transponder can support up to four AM-50 Series amplifiers operating as main amplifiers with one AM-50 Series amplifier used as a fail-safe backup amplifier. The transponder receives its power from a PM-9/ PM-9G nine ampere, filtered, switching power supply providing 24 VDC nominal operating voltage. The PM- 9/PM-9G has an integral standby battery charger capable of recharging up to 55 A/H batteries. The can house up to 12 A/H sized batteries. The Intelligent Network Transponder () acts as a network audio transponder for the NetSOLO Broadband Network. The transponder serves as the point of distribution for the system s audio and fire fighter telephone circuits and occupies a single node along the NetSOLO network. A typical assembly consists of the following: an Intelligent Network Interface-Voice Gateway (INI-VGX) module a PM-9/PM-9G power supply up to four AM-50 Series amplifiers 2

Figure 1 illustrates the NetSOLO Broadband System configuration. 7100 NetSOLO with two notification appliance circuits, each rated 1.7 amps, @ 24 VDC (Class 2 Power-limited) Optional Integral Digital Alarm Communicator Transmitter (DACT) for local or network-wide event reporting Two analog addressable Signaling line circuits For 394 devices (Class 2 Power-limited) Style 6 (Class A ) with optional CAOM Twisted-pair or fiber-optic cable between nodes. (3,000 ft. (900 m) distance with wire Up to 8 db loss fiber-optic. (Class 2 Power-limited) INCC Command Center shown with optional Microphone and FireFighter s Handset, ASM-16 Addressable Switch modules with 16 Programmable, addressable switches, each with three programmable indicating LEDs: (red, green, yellow) Transponder with six independently programmable speaker circuits, each rated 50 watts (Class 2 Power-limited) One signaling line circuit with 16 AOM-TELF and 32 AOM-2SF addressable devices (AOM-TELs shown) Style 4 (Class B ) standard (Class 2 Power-limited) Three simultaneous audio channels. Up to 16 programmable voice messages Fire fighter phone riser (Class 2 Power-limited) Figure 1 NetSOLO Broadband System 3

Figure 2 illustrates the NetSOLO Broadband System configuration. NODE 7 7100 Initiating Control Devices Typical for SLC No. 2 if used NODE 6 Local Annunciators LCD-7100 (max. 5) Global display for all network events if set to Region 0. One SLC, (16 AOM-TELFs & 32 AOM-2SFs) One phone riser 6 Speaker appliance circuits 150 watts max w/50 watts standby NODE 8 3,000 ft. (max.) between nodes using wire 8 Db loss (max.) between nodes using fiber-optic cable NODE 5 NODE 4 One SLC, (16 AOM-TELFs & 32 AOM-2SFs) 7100 Initiating Control Devices Typical for SLC No. 2 if used One phone riser 6 Speaker appliance circuits 150 watts max w/50 watts standby Connect if wired Class A, Style 6 or 7 only 7100 NODE 1 Optional Integral DACT Initiating Control Devices Typical for SLC No. 2 if used Local annunciators, LCD-7100 (Max. 5) Global display for all network events if set to Region 0 NODE 3 One SLC, (16 AOM-TELFs & 32 AOM-2SFs) One phone riser NODE 2 6 Speaker appliance circuits 150 watts max w/50 watts standby Figure 2 Node Connections 4

ORDERING INFORMATION Part Number Description INCC Intelligent Network Command Center INI-VGC Command Center Voice Gateway INI-VGC-UTP Voice Gateway for fiber-optic and unshielded twisted-pair wire ASM-16 Programmable Switch Module (occupies single slot of inner door) NGA Network Graphic Annunciator ANU-48 Remote LED Driver INCC-IDT Inner door w/one double slot for INCC-TEL fire fighter handset and 4 single slots INCC-ID Inner door w/6 single slots INCC-CABR INCC backbox (black) with red outer door 19 W x 19 H x 4 D (48 W x 48 H x 10 D cm) Optional Accessories ANU-48 Remote LED Driver INCC-TEL Fire Fighter Telephone Handset (requires INCC-IDT Inner Door) INCC-MIC Paging Microphone Module (occupies one single slot of Inner Door) INCC-BP Command Center Blank Face Plate (occupies one single slot of Inner Door) Intelligent Network Transponder -VGX Transponder Voice Gateway PM-9/PM-9G 9 ampere Power Supply AM 50 Series Amplifiers: AM-50-25 50 Watt amplifier @ 25 VRMS output AM-50-70 50 Watt amplifier @ 70.7VRMS output ORDERING INFORMATION Part Number Cabinets: -CAB -CABR CAB-B Description Backbox with Black Door 19 W x 19 H x 4 D (48 W x 48 H x 10 D cm) Backbox with Red Door 19 W x 19 H x 4 D (48 W x 48 H x 10 D cm) Enclosure louvered door and -CAB-B Mounting Plate 19 3/8 W x 19 3/8 H x 4.5 D (49 W x 49 H x 11 D cm) Note: For additional information on the cabinets, refer to the E3 Series Cabinets Data Sheet (Part Number: 9020-0649). Seismic Battery Bracket Kits Part Number Description 90518 NetSOLO NS- 7 A/H Seismic Battery Bracket Kit NetSOLO 7100 7 A/H Seismic Battery Bracket Kit 90519 NetSOLO NS- 12 A/H Seismic Battery Bracket Kit Note: For information on the types of Seismic Battery Bracket Kits available and the Seismic Battery Bracket Kit Part Numbers, refer to the following documents: Seismic Battery Bracket Installation Guide, P/N: 53839 E3 Series Cabinets Data Sheet, P/N: 9020-0649 5

NetSOLO Broadband Technical Specifications SPECIFICATIONS Detailed product specifications may be found in the following documents: 9020-0542: INCC Intelligent Network Command Center Data Sheet 9020-0531: NetSOLO Data Sheet 9020-0541: Intelligent Network Transponder Data Sheet TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 49 C/32 120 F and at a relative humidity 93% ± 2% RH (non-condensing) at 32 C ± 2 C (90 F ± 3 F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 27 C/60 80 F. STANDARDS The E3 Series Broadband System is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S1869 FM Approved: 3025415 MEA FDNY: 6077 CSFM: 6911-1703:0116 City of Chicago Approved: 7165-1703:125 City of Denver Approved ISO 9001 Certification For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewellfci.com/en-us/ documentation/pages/ Listings.aspx NetSOLO, E3 Series and Gamewell-FCI are registered trademarks of Honeywell International Inc. UL is a registered trademark of Underwriter s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-todate and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information Learn more about Gamewell-FCI s NetSOLO Broadband and other products available by visiting www.gamewell-fci.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com 9020-0551 I 09/17 2017 Honeywell International Inc.