COOL 1. Service manual

Similar documents
A2, A6 PEK Control Unit

N02 Remote control transmitter

LAF 635/LAF 635R. Instruction manual

Aristo Origo. Feed 3004 Feed Instruction manual

Feed 3004 Feed Aristot. Instruction manual

Origo M12. Feed 304 Feed 484. Instruction manual

A2- A6. Pilot lamp / Laser lamp. Bruksanvisning Brugsanvisning Bruksanvisning Käyttöohjeet Instruction manual Betriebsanweisung

Origo M12. Feed 304 Feed 484. Instruction manual. Valid for serial no. 620-xxx-xxxx, 917-xxx-xxxx

STT 3000 Series STT250 /150 Surge Protection Device Specifications

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

Beckhoff short profile

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

STANDARD T6 (200 C) SENSOR CABLE RANGE

Premium freezers combining functionality, elegance and energy efficiency

Accuracy counts! Sensors with analog output

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

LAF 635. Bruksanvisning Brugsanvisning Bruksanvisning Käyttöohjeet Instruction manual Betriebsanweisung

DESCRIPTION FEATURES WARNINGS APPLICATIONS

For more information on Tarkett go to

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

Installation Instructions

Labeling and Identification Products

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

OneWireless Gauge Reader WGR400 Series Specifications 34-XY July 2009

BFD Light Curtains The new choice for cutting edge safety for industrial doors

PTG, SWT Series. Heat Recovery Systems

International standards used locally worldwide ISO/TC 67

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

LAVASTOVIGLIE DISHWASHER LAVE-VAISSELLE GESCHIRRSPÜLER VAATWASSER LAVAVAJILLAS MÁQUINA DE LAVAR LOUÇA ΠΛΥΝΤΗΡΙΟ ΠΙΑΤΩΝ BULASIK MAKINASI

MVX 2000 Multivariable Pressure Transducer. Specifications 34-SM March Introduction. Proven Sensor Technology. Flow Computer Benefits

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

Future development of the furniture industry A look at the next 3-5 years

Power packs TectoRack. Energy-saving and ecological CO2 power packs

AutoM Click to go to the page. AutoM Auto Shaker Filter

E + M III. Suitable for interfaces. up to CATEGORY 4 per EN E197638

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

Manusa Automatic. Doors. Safety beyond the Standard. EN16005 Power operated pedestrian doorsets. Safety in use. Requirements and test methods.

Shredders from Metso. Lindemann Eta Shred

BUILD the clinic you ve always imagined.

Large variety small footprint

LAVASTOVIGLIE DISHWASHER LAVE-VAISSELLE GESCHIRRSPÜLER VAATWASSER LAVAVAJILLAS MÁQUINA DE LAVAR LOUÇA ΠΛΥΝΤΗΡΙΟ ΠΙΑΤΩΝ BULASIK MAKINASI

PRODUCT INFORMATION. SureSense THE SURE WAY TO DETECT ANY OBJECT. Photoelectric Sensors

Freezer and cooler islands TectoFreeze IS1. Reliable islands for chilled and frozen food

FF-SG Series. Safety light curtain Compact and low-cost unit

NECTOR S Line lighting components. Flexible solutions for your lighting designs

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

CRA24-B3 controlled residential ventilation

Manual de Instrucciones Campanas Extractoras DM-60/ DM-70/ DM-90 Vr. 03. Bedienungsanleitung Dunstabzugshauben DM-60/ DM-70/ DM-90 Vr.

micropac. Personal Gas Detection Instruments

KNX The worldwide STANDARD for home and building control. KNX Association International

Crushers from Metso Recycling. Metso EtaCrush

Signal converters SVE4 Product overview

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

Textile fire protection closures EI 30/90

WELCOME. Elektronische Bauelemente GmbH

FieldLink Cable solutions for Automation & Drives

WELCOME. Elektronische Bauelemente GmbH

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability

TopTechnology. TectoPromo FL2 Aida Versatile serve-over display cabinet for bakery products

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

This document is a preview generated by EVS

EN: This Datasheet is presented by the m anufacturer. Please v isit our website for pricing and availability at ore.hu.

DIAPHRAGM VACUUM PUMP LABOPORT N FT.18

Manual de Instrucciones Campanas Extractoras DBE-60/ DBE-70/ DBE-90. Bedienungsanleitung Dunstabzugshauben DBE-60/ DBE-70/ DBE-90

Fire-Resistant. Automatic Doors

Advantages of automatic boiler bottom blowdown

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Certificate of constancy of performance,

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

Expansion vessel in a solar installation. White paper

IWAKI HI-CERA PUMPS V

Multideck cabinet. TectoDeck MD2 e-ventus. A multideck breakthrough in energy efficiency

KNX The worldwide STANDARD for home and building control. KNX Association International

Large variety small footprint

Instruction Manual. Seco. Dry-running Rotary Vane Vacuum Pumps SV 1003 D, SV 1005 D

AERO 20 AERO ENGLISH - Operating Instructions

... Desiccant Cartridges Conventional and Oil Separator Cartridges (OSC) ... products derived from proven Knorr-Bremse Technology. Product Information

STANDARDISATION OF SRF (ISO/TC 300)

CBI 06 QUICK-RELEASE COUPLINGS PLASTIC INDUSTRY APPLICATIONS. Automatic locking. Non spill design. Greater efficiency.

The advantages of closed heating systems. White paper

BA4000 Series Curtain Machine

International Product Compliance and Certifications. Product Safety Consulting, Inc.

.025 Connector Series

Muting function The muting sensors must be able to recognise the passing material (pallets, vehicles, etc.) according to the material's length and spe

maxsys TRIO/DUO BOILER SYSTEM

Forum for European Electrical Domestic Safety FEEDS. Residential Electrical Safety How to ensure progress?


Motor Kit for SW Shutter. Instruction Manual. Motor Kit for SW Shutter. Models: FA2685. Munters Corporation, November 2013 QM1017r6

AX51 with Munters Drive

30th. English. Anniversary Since 1980 RICH. Heat & Cool molding system RICH-2. ZICUL (Chiller) WATER PURIFIER

EN ISO Welding coordination Tasks and responsibilities. Schweißaufsicht Aufgaben und Verantwortung (ISO 14731:2006)

Cable sealing solutions. for hazardous areas

Return loss measurement of fiber optic components

Upright freezer cabinet TectoFreeze VF1 Luxo. High volume freezer line. Heating systems Industrial systems Refrigeration systems

COOL COMBINATION EQUIPMENT PROTECTION SOLUTIONS INDUSTRIAL ENVIRONMENTS

Multidecks TectoDeck MD4 Leho TectoDeck RI4 Leho. Energy efficiency with a system

Operation Manual Part-No

List of nationally authorised medicinal products

BA2702-P Linear Actuator

Transcription:

COOL 1 Service manual 0740 800 210 101102 Valid for serial no. 033-xxx-xxxx

READ THIS FIRST................................................................. 3 TECHNICAL DATA................................................................. 4 WIRING DIAGRAM................................................................. 4 Component description.......................................................... 4 COOL1......................................................................... 5 DESCRIPTION OF OPERATION..................................................... 6 5 Cooling unit................................................................... 6 5AP1:1 Monitoring the coolant flow............................................... 6 5AP1:2 Pump motor and fan ON/OFF............................................ 6 5AP1 Component positions.................................................... 8 SERVICE INSTRUCTIONS.......................................................... 9 What is ESD?................................................................... 9 Service aid...................................................................... 9 INSTRUCTIONS................................................................... 10 SAFETY........................................................................ 10 INSTALLATION................................................................. 10 Installing to welding equipment.................................................. 10 Assembly instructions........................................................... 11 OPERATION.................................................................... 13 Connections and control devices................................................. 13 Coolant connection............................................................. 13 Water flow guard................................................................ 13 MAINTENANCE................................................................. 13 Inspection and cleaning......................................................... 14 Filling the coolant............................................................... 14 Caracteristics................................................................... 15 SPARE PARTS.................................................................... 16 NOTES........................................................................... 17 Rights reserved to alter specifications without notice. TOCe - 2 -

READ THIS FIRST Maintenance and repair work should be performed by an experienced person, and electrical work only by a trained electrician. Use only recommended replacement parts. This service manual is intended for use by technicians with electrical/electronic training for help in connection with fault-tracing and repair. Use the wiring diagram as a form of index for the description of operation. The circuit boards are divided into numbered blocks, which are described individually in more detail in the description of operation. Component names in the wiring diagram are listed in the component description. Use the spare parts list as a guide to where the components are located in the equipment. The spare parts list is published as a separate document, see page 16. This manual contains details of design changes that have been made up to and including October 2010. The manual is valid for COOL 1 with serial no. 033-xxx-xxxx The COOL 1 is designed and tested in accordance with international and European standards IEC/EN 60974. On completion of service or repair work, it is the responsibility of the person(s) performing the work to ensure that the product still complies with the requirements of the above standard. CAUTION! Read and understand the instruction manual before installing or operating. ESD CAUTION! STATIC ELECTRICITY can damage circuit boards and electronic components. Observe precautions for handling electrostaticsensitive devices. Use proper static-proof bags and boxes. ck10_00-3 -

TECHNICAL DATA Power consumption Cooling power Equivalent continuous A-weighted sound pressure level Coolant Coolant quantity Maximum flow Maximum pressure Operating temperature Transportation temperature Dimensions lxwxh Weight empty Enclosure class COOL 1 24V DC / 2A 1.3 kw (Rating at 40 K and 1 l/min) < 70 db (A) Ready mixed (50% water and 50% mono-ethylene glycol) 4.5 l 2.0 l/min 4 bar -10 to +40 C -20 to +55 C 610 x 256 x 256 mm 12 kg IP23 Enclosure class The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid objects or water. Equipment marked IP23 is designed for indoor and outdoor use. WIRING DIAGRAM Component description Component Description 5 Cooling unit 5AP1 Circuit board with control electronics 5M1 Pump with motor, 24V DC 5S1 Coolant pressure switch (enclosed in pump 5M1) 5EV1 Cooling fan, 24V DC 5SL1 Flow guard. Monitoring coolant flow (option) 5XP.. Plug connector (Pin) 5XS.. Socket connector (Sleeve) 5XT.. Terminal block ck10_00-4 -

COOL1 ck10_00-5 -

DESCRIPTION OF OPERATION This description of operation describes the function of circuit boards and other components in the equipment. 5 Cooling unit 5AP1:1 Monitoring the coolant flow Circuit diagram for coolant flow guard COOL1 is prepared for optional coolant flow monitoring. Replace the jumper cable 513 with the flow guard sensor, 5SL1, and connect it to terminal block 5XT1 (CN4) on cooling unit board, 5AP1. The sensor switch opens at flow rate < 0.7 l/min. The MMC panel of the system displays fault code 29,(no cooling water flow), if the input to the processor is high. (Measure at point SP3 on 20AP1) Supervision of hoses connection, ELP (ESAB Logic Pump) is not installed in COOL1. 5AP1:2 Pump motor and fan ON/OFF The pump motor, 5M1, and cooling fan, 5EV1, are connected in parallell and powered from the power supply board, 2AP3, in the power source. The power is 25V DC and named 25V_WP in the cooling unit board, 5AP1. An output from the processsor on control board 20AP1 connects input 20XS5:2 (WP2) to 0V. (Measure at point SP1 on 20AP1). Transistor Q2 in cooling unit board, 5AP1, connects pump motor and fan to 0V, and the pump and fan start. The pump, 5M1, has an enclosed coolant pressure switch, 5S1, which switches off the power to the pump motor if the coolant pressure is too high. This can occur if a hose is folded which make flow to fail or stop. The cooling fan however is still powered and running. ck10_05-6 -

Pump motor and fan ON/OFF Circuit diagram for pump motor and cooling fan ck10_05-7 -

5AP1 Component positions Component positions on the cooling unit board, 5AP1. Terminal block CN4 is also named 5XT1 in the diagram. ck10_05-8 -

SERVICE INSTRUCTIONS ESD CAUTION! STATIC ELECTRICITY can damage circuit boards and electronic components. Observe precautions for handling electrostaticsensitive devices. Use proper static-proof bags and boxes. What is ESD? A sudden transfer or discharge of static electricity from one object to another. ESD stands for Electrostatic Discharge. How does ESD damage occur? ESD can cause damage to sensitive electrical components, but is not dangerous to people. ESD damage occurs when an ungrounded person or object with a static charge comes into contact with a component or assembly that is grounded. A rapid discharge can occur, causing damage. This damage can take the form of immediate failure, but it is more likely that system performance will be affected and the component will fail prematurely. How do we prevent ESD damage? ESD damage can be prevented by awareness. If static electricity is prevented from building up on you or on anything at your work station, then there cannot be any static discharges. Nonconductive materials (e.g. fabrics), or insulators (e.g. plastics) generate and hold static charge, so you should not bring unnecessary nonconductive items into the work area. It is obviously difficult to avoid all such items, so various means are used to drain off any static discharge from persons to prevent the risk of ESD damage. This is done by simple devices: wrist straps, connected to ground, and conductive shoes. Work surfaces, carts and containers must be conductive and grounded. Use only antistatic packaging materials. Overall, handling of ESD-sensitive devices should be minimized to prevent damage. Service aid Antistatic service kit Ordering no. 0740 511 001 The kit makes it easier to protect sensitve components from electrostatic discharge. Contents: A conductive mat (size 610 x 610 mm) A 1.5 metre long ground cable with a crocodile clip An adjustable wrist strap and cable with an inbuilt protective resistor Antistatic service kit ck10f2-9 -

INSTRUCTIONS This chapter is an extract from the instruction manual for the COOL1. SAFETY CAUTION! Read and understand the instruction manual before installing or operating. INSTALLATION The installation must be executed by a professional. Location Position the cooling unit such that its air inlets and outlets are not obstructed. Power supply and control COOL1 is powered and controlled from the power source via socket connector XS4 in the bottom of the power source. The plug connector 5XP1 on top of the cooler is connected to XS4. Installing to welding equipment See assembly instructions on page 11. ck10i1-10 -

Assembly instructions COOL1 + Aristo 300, Aristo 400 or Aristo 500 ck10i1-11 -

Water flow guard (Option) ck10i1-12 -

OPERATION General safety regulations for the handling of the equipment can be found in the instruction manual. Read through before you start using the equipment! Connections and control devices 1 Filling the coolant 2 BLUE connection for coolant from cooling unit 3 Connection RED for coolant (return) to cooling unit. Coolant connection For problem free operation it is recommended that the height from the cooling unit to the watercooled MIG/MAG gun is maximum 8.5 m. Water flow guard The water flow guard blocks the power source if the coolant stops flowing(< 0.7 l/min.). The water flow guard is an accessory. MAINTENANCE Regular maintenance is important for safe, reliable operation. Only those persons who have appropriate electrical knowledge (authorized personnel) may remove the safety plates. CAUTION! All guarantee undertakings from the supplier cease to apply if the customer himself attempts any work in the product during the guarantee period in order to rectify any faults. ck10i1-13 -

Inspection and cleaning WARNING! The mains supply must be disconnected before cleaning! Dust, grinding swarf etc The air stream through the cooling unit carries particles that become trapped in the cooling element, particularly in dirty working environments. This results in reduced cooling capacity. For this reason, blow clean using compressed air at regular intervals. The coolant system - The recommended coolant must be used in the system otherwise clumps can be created that block the pump, water connections or elements. Flushing can only be performed via red water connection. Then drain the tank manually, i.e. empty via the tank's filing hole. Filling the coolant ESAB's coolant is recommended for use. See accessories in instruction manual. Fill with coolant. (The fluid level must not exceed the upper marking but neither must it be below the lower marking) Note! Coolant must be topped up if connecting a welding gun or coolant hoses that are 5 metres in length or longer. When adjusting the water level by topping up, the coolant hoses do not need to be disconnected. The temperature of the coolant must not exceed 70 C CAUTION! The coolant must be handled as chemical waste. ck10i1-14 -

Caracteristics Pump data p = Pump pressure (MPa) Q = Flow rate (l/min) ck10i1-15 -

Cooling caracteristic (at 1 l/min) P = Power (kw) K = Temperature difference between inlet water temperature and ambient temperature (K) SPARE PARTS The spare parts list is published in a separate document that can be downloaded from the internet: www.esab.com Filename Product 0459 839 048 COOL 1 ck10i1-16 -

NOTES notes - 17 -

ESAB subsidiaries and representative offices Europe AUSTRIA ESAB Ges.m.b.H Vienna-Liesing Tel: +43 1 888 25 11 Fax: +43 1 888 25 11 85 BELGIUM S.A. ESAB N.V. Brussels Tel: +32 2 745 11 00 Fax: +32 2 745 11 28 THE CZECH REPUBLIC ESAB VAMBERK s.r.o. Vamberk Tel: +420 2 819 40 885 Fax: +420 2 819 40 120 DENMARK Aktieselskabet ESAB Herlev Tel: +45 36 30 01 11 Fax: +45 36 30 40 03 FINLAND ESAB Oy Helsinki Tel: +358 9 547 761 Fax: +358 9 547 77 71 FRANCE ESAB France S.A. Cergy Pontoise Tel: +33 1 30 75 55 00 Fax: +33 1 30 75 55 24 GERMANY ESAB GmbH Solingen Tel: +49 212 298 0 Fax: +49 212 298 218 GREAT BRITAIN ESAB Group (UK) Ltd Waltham Cross Tel: +44 1992 76 85 15 Fax: +44 1992 71 58 03 ESAB Automation Ltd Andover Tel: +44 1264 33 22 33 Fax: +44 1264 33 20 74 NORWAY AS ESAB Larvik Tel: +47 33 12 10 00 Fax: +47 33 11 52 03 POLAND ESAB Sp.zo.o. Katowice Tel: +48 32 351 11 00 Fax: +48 32 351 11 20 PORTUGAL ESAB Lda Lisbon Tel: +351 8 310 960 Fax: +351 1 859 1277 SLOVAKIA ESAB Slovakia s.r.o. Bratislava Tel: +421 7 44 88 24 26 Fax: +421 7 44 88 87 41 SPAIN ESAB Ibérica S.A. Alcalá de Henares (MADRID) Tel: +34 91 878 3600 Fax: +34 91 802 3461 SWEDEN ESAB Sverige AB Gothenburg Tel: +46 31 50 95 00 Fax: +46 31 50 92 22 ESAB international AB Gothenburg Tel: +46 31 50 90 00 Fax: +46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel: +41 1 741 25 25 Fax: +41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires Tel: +54 11 4 753 4039 Fax: +54 11 4 753 6313 BRAZIL ESAB S.A. Contagem-MG Tel: +55 31 2191 4333 Fax: +55 31 2191 4440 Asia/Pacific CHINA Shanghai ESAB A/P Shanghai Tel: +86 21 2326 3000 Fax: +86 21 6566 6622 INDIA ESAB India Ltd Calcutta Tel: +91 33 478 45 17 Fax: +91 33 468 18 80 INDONESIA P.T. ESABindo Pratama Jakarta Tel: +62 21 460 0188 Fax: +62 21 461 2929 JAPAN ESAB Japan Tokyo Tel: +81 45 670 7073 Fax: +81 45 670 7001 MALAYSIA ESAB (Malaysia) Snd Bhd USJ Tel: +603 8023 7835 Fax: +603 8023 0225 SINGAPORE ESAB Asia/Pacific Pte Ltd Singapore Tel: +65 6861 43 22 Fax: +65 6861 31 95 SOUTH KOREA ESAB SeAH Corporation Kyungnam Tel: +82 55 269 8170 Fax: +82 55 289 8864 UNITED ARAB EMIRATES ESAB Middle East FZE Dubai Tel: +971 4 887 21 11 Fax: +971 4 887 22 63 Representative offices BULGARIA ESAB Representative Office Sofia Tel/Fax: +359 2 974 42 88 EGYPT ESAB Egypt Dokki-Cairo Tel: +20 2 390 96 69 Fax: +20 2 393 32 13 ROMANIA ESAB Representative Office Bucharest Tel/Fax: +40 1 322 36 74 RUSSIA LLC ESAB Moscow Tel: +7 095 543 9281 Fax: +7 095 543 9280 LLC ESAB St Petersburg Tel: +7 812 336 7080 Fax: +7 812 336 7060 Distributors For addresses and phone numbers to our distributors in other countries, please visit our home page www.esab.com HUNGARY ESAB Kft Budapest Tel: +36 1 20 44 182 Fax: +36 1 20 44 186 ITALY ESAB Saldatura S.p.A. Mesero (Mi) Tel: +39 02 97 96 81 Fax: +39 02 97 28 91 81 THE NETHERLANDS ESAB Nederland B.V. Amersfoort Tel: +31 33 422 35 55 Fax: +31 33 422 35 44 CANADA ESAB Group Canada Inc. Missisauga, Ontario Tel: +1 905 670 02 20 Fax: +1 905 670 48 79 MEXICO ESAB Mexico S.A. Monterrey Tel: +52 8 350 5959 Fax: +52 8 350 7554 USA ESAB Welding & Cutting Products Florence, SC Tel: +1 843 669 44 11 Fax: +1 843 664 57 48 ESAB AB SE-695 81 LAXÅ SWEDEN Phone +46 584 81 000 www.esab.com 081016