GLYCOL CHILLER INSTRUCTIONS IMPORTANT: BEFORE OPERATING PLEASE SEE INSTRUCTIONS ON PAGE 9

Similar documents
GLYCOL CHILLER INSTRUCTIONS IMPORTANT: BEFORE OPERATING PLEASE SEE INSTRUCTIONS ON PAGE 5

Conical Fermenter. Instructions

AACH50 1/2 HP GALLONS (200 TO 1200L) INSTRUCTION MANUAL

INSTRUCTIONS WATER CHILLERS. Active Aqua Chiller, 1/10 HP. Active Aqua Chiller, 1/4 HP. DISTRIBUTED BY

Portable Ice Maker User Guide

Local Air Conditioner

Up to 60 Pint Commercial Grade DEHUMIDIFIER

OVA-EASY ADVANCE. HATCHER User Instructions

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

Dehumidifier/Dryer. Model: EDV Please read the instruction manual before operating. Keep in a safe place for future reference

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

Portable Air-conditioner

RLD-H10P Refrigerant Leak Detector

INSTALLATION and OPERATION INSTRUCTIONS

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Important Notes: Please read carefully before installing your refrigerator.

OVA-EASY ADVANCE. HATCHER User Instructions

Portable Air Conditioner USER MANUAL

SLUSH PUPPiE MACHINE Instructions For Use

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

Portable Air Conditioner

Split Portable Air Conditioner

AC-12200E Portable Air Conditioner

Rev B, 9/2/2009. Kodiak Chiller Overview

Cooler Manual XRC-3012-WA 3000 Watt water to air cooler

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

PORTABLE AIR CONDITIONER

EURO APPLIANCES BY EUROSTYLE GROUP

Technical Training Prodigy Undercounter Cubers. Models CU1526, CU2026 and CU3030

5) Do not start or stop the unit by inserting or pulling out the power plug.

Installation, Operation and Maintenance Manual

REMOTE COOLER AIR COOLED & WATER COOLED

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

Installation and Operation Guide For MCF-49FD, MCF-23FD MCR-49FD, MCR-23FD

Zen Boiling Tap Range

PRE INSTALLATION PROCEDURES

Installation and Operation Guide For

Dehumidifier Owner s Manual Read and save these instructions before use

H-10PM. Refrigerant Leak Detector

HOT TANK INSTALLATION AND OPERATING INSTRUCTIONS. Model #: 5000

OPERATING INSTRUCTIONS

Dehumidifier. Instruction Manual. Model DH-320/A

User manual. Fridge Freezer ZRT18100WA

30-pint Dehumidifier User Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

MeacoDry ABC Range Dehumidifiers

PC20-AMFII / PC40-AMF USER MANUAL

4L Instant Water Boiler Instructions for Use

Portable Air-conditioner Use and Care Manual

POLYMIX PX-IG 2000 Operating Instructions

Ultrasonic Humidifier TALL. Product Manual

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

MeacoClean CA-HEPA 119x5 Air Purifier

RLD-H10G Refrigerant Leak Detectors

Owner's Manual. WS Series. Water Softener

Chiller with BP-1 1/2 oz Pump

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

Automatic Ice Maker. Service Manual VT ICEMAKER 15

Brewmaster Edition Chronical Fermenter 1 Barrel Supplemental Report

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

air conditioner/dehumidifier 9000btu/hr

Ultrasonic Humidifier DROP. Product Manual

Owner s Manual Super-Slim Four-Way Cassette

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

Portable Air Conditioner User Manual

Operation Manual. VWR Vacuum Ovens. (Version 2.0.0) VWR Vacuum Oven , , , ,

20L/D DEHUMIDIFIER Model Number: IG9800

Operation Manual. (Version 1.5.1)

TLC-40 Eco / TLC-50 Eco. User instructions

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

OIL COOLER INSTRUCTION HANDBOOK

IMI CORNELIUS CHILLER

TLC-40 Advance / TLC-50 Advance. User instructions

Operator Guide. Publication No. OI /97-Eng. KODAK Automixer II Plus

VIVA ace Quick Operation Guide

WL380 QUICK START GUIDE

Refrigerant Recovery Machine. Model No Operating Manual

REFRIGERAT A OR USE DF1-15 F ridge

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

Model No: Little Devil II (inc ss)

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

Mobile Air Conditioner Instruction Manual Model TC-N9KM

SPECIFICATIONS PART NAME

OPERATING INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Progress plus Instruction manual

DOMESTIC STEAM GENERATOR Installation Instructions

COMMERCIAL GRADE UNDER COUNTER REFRIGERATION RANGE

Operator s Manual. Histology Bath

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

USER MANUAL HD SERIES. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704 HD5.

INSTALLATION and OPERATION INSTRUCTIONS

Trotec PAC FT 2600 Portable air conditioner

Transcription:

GLYCOL CHILLER INSTRUCTIONS IMPORTANT: BEFORE OPERATING PLEASE SEE INSTRUCTIONS ON PAGE 9

CONTENTS Key features...p.1 Product contents...p.1 Safety information...p.2 Maintenance...p.2 How it works...p.5 Set up and preparation...p.5 Mixing and filling glycol...p.5 Preparing cooling connections...p.6 Connecting the chiller to a fermenter...p.6 Operating and using the chiller...p.7 Setting glycol temperature...p.7 Setting fermenter temperature...p.8 Connecting more than one fermenter...p.8 Troubleshooting...p.9

KEY FEATURES LED displays. 6 L (1.6 US Gal) glycol tank. Cools a Grainfather Conical Fermenter to a minimum temperature of 4-6 C (39-43 F)*. Connect up to four fermenters and ferment each one at a different temperature. Glycol temperature controller. 3 pin power connections for fermenters. The R600a refrigerant used is an environmentally friendly replacement for other refrigerants causing no effects to the ozone layer or the greenhouse effect. * Minimum temperature will vary based on external factors such as ambient room temperature, the number of fermenters connected and other environmental conditions. A B * C D E INCLUDES A 1 x Glycol Chiller B 1 x wall outlet power cord (with plug based on country of sale) C 2 x couplers (with self-sealing hose connections) D 2 x 2 m (6.5 ft) hoses E 1 x Glycol Funnel ALSO SHOWN (not included): *1 x M12 power cord (taken from Conical Fermenter) 01.

SAFETY INFORMATION 1. When transporting, keep level and lift from the base. 2. Never tip the unit on its side or upside down. This will void the warranty as it will damage the electronics. 3. Always operate on a flat surface in a well ventilated environment. 4. Keep the sides of the unit where the vents are clear of any objects as it requires uninterrupted air flow to operate. 5. Avoid getting any liquid on the controls area. 6. Always use monopropylene food grade glycol. Seek glycol manufacturers specifications for more information. 7. When transporting, keep level and lift from the base. MAINTENANCE: 1. Turn off chiller before cleaning. 2. Regularly clean the air inlet & outlet using a soft brush. 3. DO NOT clean the stainless steel or plastic casing with a wire brush or steel wool. 4. Use water or washing liquid that does not contain alkali or chlorine. 5. DO NOT spray water onto ventilation louvers. 6. Regularly check the glycol mixture level to make sure it is not too low. For optimal performance it is recommended to replace the glycol mixture every 6 months at minimum. PRODUCT NAME: GLYCOL CHILLER Rated: 300W - 3.0A max 220-240V ~ 50Hz 110-120V ~ 60Hz Dimensions (mm) - 390W x 405D x 656H Total Weight - 28.3 Kg (63 lb) Made in China 02. Z988

03.

Control your fermentation temperature accurately. Every time. Temperature control is one of the most crucial elements for producing a good quality beer. It needs to be regulated and stable throughout the whole fermentation process to ensure the yeast doesn t get stressed and ferments correctly to get the right flavour profile. With the ability to individually control the temperature of up to four Grainfather Conical Fermenters, each with their own fermenting schedules, the Grainfather Glycol Chiller is the perfect addition to your brewery to ensure superior results. 04.

HOW IT WORKS This product cools a Grainfather Conical Fermenter to a minimum optimal temperature of 4-6 C (39-43 F)*. The cold glycol can be used keep the beer in a fermenter at a desired temperature. The glycol chiller includes a pump with 4 connections to make it possible to connect and control the temperature of up to four 30 L (8 US Gal) Grainfather Conical Fermenters in total. Please see page 8 for further information. SET UP AND PREPARATION IMPORTANT Make sure the chiller has been standing upright for 24 hours before turning it ON. Arrange and place the Glycol Chiller close to your fermenters so that all connections can be made without the need to move the unit again. MIXING AND FILLING GLYCOL IMPORTANT Please follow mixing instructions exactly as instructed below. Any variance in the mix ratio can result in damage to the chiller s pump while under operation. The glycol tank is made to hold 6 L (1.5 US Gal) of monopropylene glycol mixture. To make the mixture you will need to combine 50% glycol and 50% water. - 3 L (0.8 US Gal) of glycol - 3 L (0.8 US Gal) water NOTE: Please ensure when mixing you use a clean vessel free from any foreign matter. Then use the included Grainfather Glycol Funnel with mesh filter to transfer mixture into the chiller. As contaminants have the potential to cause blockages. 1. Open the cap on the top of the glycol chiller. Using the included Grainfather Glycol Funnel with mesh filter, add glycol mixture to the tank. 2. Replace and tighten the cap. NOTE: It is important to always make sure there is enough glycol in the tank. Always make sure the float in the glycol tank reaches the max line, if it is noticeably below this line then you need to fill more glycol mixture. It is important to look at this level at least once a week and when connecting to additional fermenters (refer to page 8). Factors such as water evaporation can also affect the level of this mixture. For optimal performance choose to replace the glycol mixture every 6 months at minimum. Fill glycol here 05.

PREPARING COOLING CONNECTIONS A cooling connection kit is included with your Glycol Chiller (see page 1). This consists of brass couplers and hoses. Firstly, connect the couplers to the fermenter: 1. Take the threaded section of the coupler and connect it to one side of the Grainfather Conical Fermenter. Make sure it is screwed in tightly. Use a spanner if necessary. 2. Connect the other end of the coupler to the section you just used by pushing the spring-loaded sleeve back and sliding it over. 3. Repeat these steps on the other side of the fermenter. It is possible to cut the hoses shorter if necessary; this will also increase maximum cooling efficiency. Place the chiller and fermenter in their final place, measure and cut the hoses accordingly. CONNECTING THE CHILLER TO A FERMENTER On the back panel of the Glycol Chiller are the connections for the hoses. You can connect up to four fermenters to the chiller. The output connections from the chiller are silver in colour and the return connections are gold. The buttons on the front of the chiller labelled 1,2,3,4, match up to the connections on the back labelled accordingly. 1. Make sure the unit is turned off. 2. On the back panel of the chiller locate the glycol mixture output connections; these are silver in colour. Connect the blue hose to the first silver connector labelled with number 1. This hose then connects to the coupler on the fermenter that is attached in the lowest position. 3. The glycol inlet connection is where the glycol is returned to the chiller to cool back down; these are gold in colour. Connect the red hose to the glycol return inlet connection labelled with number 1. This hose then connects to the coupler on the fermenter that is attached in the highest position. 4. The Chiller will provide power to all fermenters that are connected. Connect the M12 power cord from your Grainfather Conical Fermenter to this connection under number 1. 06.

OPERATING AND USING THE CHILLER 1. Plug the power cord into the back of the Glycol Chiller and the other end into a wall socket. 2. Turn the power to the chiller on by pressing the power button on the front panel, the button will light up red. 3. The fermenter will now get its power from the glycol chiller via the M12 power cord that was included with your fermenter. 4. If the Glycol Chiller is plugged in and switched on, the fermenter will also turn on if plugged in correctly to the chiller. NOTE: The chiller will provide power to the fermenter/s via the M12 power cord that was included with your fermenter. You do not need to use the wall plug on the fermenter once connected to the Glycol Chiller. TEMPERATURE CONTROL NOTE: Please read this thoroughly first before use. We have configured the unit to the optimal settings, as to provide the best cooling efficiency from the chiller to a fermenter for ANY required fermentation temperature. We highly recommend to not change these settings, as this could result in poor cooling performance and in extreme cases the glycol mixture may even freeze, which has the potential to cause damage to the chiller unit. If your controller is required to be reset please see below the factory settings and method to complete this. OFF TEMPERATURE = -2.8 C (-19.3 F) ON TEMPERATURE = -2.0 C (-18.8 F) 1. Press and hold the OK button to unlock the controller. 2. Press the Off temp button. 3. Use the Up/Down buttons to set the temperature (see above). 4. Repeat with the On temp button. 5. Press and hold the OK button to lock the controller again. 07.

SETTING FERMENTER TEMPERATURE 1. Set the desired fermenting temperature on the Grainfather Conical Fermenter s controller. 2. Press the number button on the glycol chiller that corresponds to the outlets that will be in use. 3. The fermenter will now signal to the glycol chiller if it needs any additional glycol. NOTE: The chiller will provide power to the fermenter/s via the M12 power cord that was included with your fermenter. You do not need to use the wall plug on the fermenter once connected to the Glycol Chiller. CONNECTING MORE THAN ONE FERMENTER The glycol chiller can allow up to four 30 L (8 US Gal) Grainfather Conical Fermenters to be connected at one time. When connecting more than one fermenter, repeat the connection steps (see page 6) for each additional fermenter that needs to be connected by matching the remaining connections labelled from 2-4. Then complete the following: 1. Top up the glycol tank for each additional fermenter connected. Every time an additional fermenter is connected, add 300 ml (10 fl oz) of glycol/water mixture into the glycol tank to compensate for this. See page 5 for mixing ratios. 2. Check that each fermenter is plugged into the correct connections. Take care to make sure that each fermenter is plugged into the correct numbers on the glycol chiller. It is a good idea to label the fermenter and hoses to the matching number on the glycol chiller to avoid any confusion. Note: For safety reasons if the glycol level is too low, the pump will automatically switch off and the power button on the chiller will flash. When this happens, refill the glycol tank to its recommended level (see page 5 and point 3 above) to restart the pump. 08.

IMPORTANT - PLEASE READ We have configured the unit to the optimal settings, as to provide the best cooling efficiency from the chiller to a fermenter for ANY required fermentation temperature. We highly recommend to not change these settings, as this could result in poor cooling performance and in extreme cases the glycol mixture may even freeze, which has the potential to cause damage to the chiller unit. Please see page 7 for further details. After operating the Glycol Chiller with the Grainfather Conical Fermenter, please take care when disconnecting the cooling hose couplers from the fermenter as the glycol/water mixture may flow out of the lower coupler that is attached to the body of the fermenter. We recommend using a thoroughly cleaned container that can hold at least 300 ml (10 US fl oz) to collect the liquid. NOTE: If choosing to reuse the glycol mixture collected, make sure it is clean and free from contaminants/particles. Please see page 5 for further information. TROUBLESHOOTING PROBLEM CAUSE TROUBLESHOOTING Unable to start normally Failed to cool or cooling speed is low Unable to supply glycol mixture to the fermenter Temperature controller warning Code: E1 Temperature controller warning Code: E2 Wall outlet error Failed to press power switch Power switch failure The temperature set by the temperature controller was too high The ventilation inlet/outlet were blocked Connecting lines were clogged or bent Failed to start the correct pump Connected the hoses to the wrong inlets/outlets Low liquid level of glycol mixture in the tank Power connection cable is not connected to fermenter correctly Thermometer probe failure Interference with memory data of the temperature controller Detach from wall power socket and plug-in again Press power switch and the indicating lamp will start shining Contact your after-sales services Reset the temperature (see page 7) Clean and clear blockage Check pipelines Press the correct pump power switch Recheck hose connections Add more glycol mixture (refer to page 8) Check whether the power cable connection is tightly screwed in Please contact your after-sales service Turn off the power supply for five minutes and then restart 09.

Reorder: 10233 Version: 3_T www.grainfather.com 06. 01.