Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Similar documents
Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Portable Evaporative Air Cooler Safety & Maintenance Guide User tips and safety instructions

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Portable Air Conditioner User Manual

EVAPORATIVE AIR COOLER SERVICE MANUAL

Dehumidifier Owner s Manual Read and save these instructions before use

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER'S MANUAL Read and save these instructions before use.

Portable Air Conditioner User Manual Read and save these instructions before use

Thanks for shopping with Improvements! Evaporative Air Cooler with Adjustable Flow Valve Item #437979

OWNER'S MANUAL. 101-Pint Commercial Indoor Portable Evaporative Cooler. Model: SF-48LB. Read and save these instructions before use

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

If you have any problems with this product, please call BEFORE returning it to your retailer.

Please read all these instructions carefully before using this product.

Operating Instructions

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

JMATEK North America LLC Mahwah, New Jersey USA Phone: Web:

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

CONTENTS 1 SAFETY INSTRUCTIONS.. 2 FEATURES AND OPERATION... 3 PARTS LIST AND INSTALLATION. 4 CONTROL PANEL AND SETTINGS...

Arctic EVAPORATIVE COOLER USER MANUAL

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

EVAPORATIVE AIR COOLER Instruction Manual

10L Evaporative Cooler with Timer

40cm Pedestal Fan with Remote Control

EVAPORATIVE COOLER W

EVAPORATIVE AIR COOLER

PORTABLE AIR CONDITIONER

2.4kW Ceramic Heater Model: DHCER24SW

Reverse Cycle Split System Air Conditioner

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

Evaporative Cooler 10 litre

5) Do not start or stop the unit by inserting or pulling out the power plug.

PORTABLE AIR CONDITIONER


Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

AF-1000 Series. Evaporative Cooler. OWNER S MANUAL v1.0. Read and save these instructions.

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Contents. Functions READ AND SAVE THIS INSTRUCTION MANUAL. Air Cooler. Model SF-608R

Honeywell Portable Air Conditioners. A compact, easy to use portable cooling solution.

Stand Fan. English. Owner s Guide. Model F R

PERSONAL Ultrasonic Cool Mist Humidifier

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

Air Conditioner Features...8 Operating Instruction Care and Cleaning...17 Before You Call...18 Major Appliance Limited Warranty...

Scan the below QR code to download Smart Flame

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

Air Purification System. Instruction Book CLI-AP20

OWNER'S MANUAL DIGITAL OIL FILLED RADIATOR HEATER WITH REMOTE CONTROL ITEM NO.: MG-MTOH907L. 120V ~ 60Hz 1500W

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ

ENGLISH INSTRUCTION MANUAL PLM 9KE-410 /12KE-410 /15KE-410 PLUS HEATER VERSIONS

EC111W. Portable Evaporative Cooler. OWNERS MANUAL v1.1. Read and save these instructions.

AF-1000 Series Evaporative Cooler OWNERS MANUAL

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

With Remote Control. English. Model

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

Mood Light and Nature Sound Alarm Clock

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

PORTABLE EVAPORATIVE COOLER EC111B OWNER S MANUAL

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

ULTRASONIC MIST FAN 80W A GILMAN GROUP BRAND

Owner's Manual TABLE OF CONTENTS

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Mobile Evaporative Cooler. Use & Care Guide MC18M INDEX

Portable Air Conditioner Instruction Manual

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

Trotec PAC FT 2600 Portable air conditioner

Portable Air Conditioner USER MANUAL

OWNER S GUIDE TYPE A TYPE C TYPE B TYPE E TYPE F TYPE D COOL FAN OFF. CA Series << FAN SPEED COOL FAN AUTO SLEEP TIMER FAN SPEED

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

EVAPORATIVE COOL MIST HUMIDIFIER Instruction Manual

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Service Manual. Model Number: DWOP20R. UL Part Number

ACCESSORIES INCLUDED

Instruction Manual. Portable Air Conditioner

DIGITAL QUARTZ INFRARED HEATER. Model No.: SPP1500SBH

10,000 BTU Portable Air Conditioner

Please read and keep manual to ensure safe and effective use of this Appliance HOUSEHOLD USE ONLY

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Amazon Decorative Electric Fireplace with On Screen Display

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

Ultrasonic Humidifier

Ultrasonic Humidifier DROP. Product Manual

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

Transcription:

Portable Evaporative Air Cooler User Manual Read and save these instructions before use Product video: www.honeywellaircoolers.com/products/co30xe www.jmatek.com E-mail: usinfo@jmatek.com Model: CO30XE

PARTS DESCRIPTION (1) (10) (8) (14) (7) (2) (3) (12) (11) (4) (6) (9) (13) (5) 1) Control Panel 2) Handle 3) Louvers 4) Water Tank 5) Power Cord & Plug USE & OPERATION CONTROL PANEL 6) Casters 7) Ice Compartment Lid 8) Rear Grill 9) Water Level Indicator 10) Remote Control 11) Detachable Water Tank Latch 12) Water Fill Door 13) Drain Plug 14) Water Regulator WARNING -- READ AND SAVE THE AIR COOLER SAFETY & MAINTENANCE GUIDE AND USER MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY DAMAGE AND/ OR IMPAIR ITS OPERATION AND VOID THE WARRANTY. IN CASE THERE IS ANY INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH VERSION AND ANY OTHER LANGUAGE VERSION OF THE CONTENT OF THIS MATERIAL, THE ENGLISH VERSION SHALL PREVAIL. Icons on Display Screen Low water level in tank Cool Fan speed Low speed Medium speed FUNCTION BUTTONS POWER Press the button to turn the unit on. The cooler will start automatically at medium speed. After a few seconds the speed will switch to low. To turn the unit off, press the button again. SPEED Press the SPEED button repeatedly to change the speed between High - Medium - Low. The indicator light will show the selected speed: High Medium Low High speed Swing Timer Natural COOL Press the COOL button until is illuminated on the display screen. This activates evaporative cooling. The water pump will operate and you will feel the cooler air after the Honeycomb Cooling Media is completely wet. When the is not illuminated on the display screen, the unit switches to a fan only mode, without evaporative cooling. EN 1

USE & OPERATION (CONTINUED) FUNCTION BUTTONS (CONTINUED) WARNING: Please ensure sufficient water is in the water tank otherwise you may hear a Low Water Alarm and the cooler will start in a Fan only mode without evaporative cooling. TIMER Press the TIMER button until the desired time duration setting is selected. When the set time has passed, the unit will automatically turn off (unit remains in Standby mode until power cord is unplugged from electrical socket). The TIMER function allows you to program the unit for up to 7.5 hours of use. SWING Press the SWING button until is illuminated on the display screen. The louvers will begin to move left to right automatically. Vertical Air Flow - You can manually adjust the louvers to change vertical air flow. NATURAL Press the NATURAL button until is illuminated on the display screen. The fan will randomly change between High, Medium and Low speeds to mimic a natural breeze. ROOM COOLING AND HUMIDIFYING LOUVER MOVEMENT In cooling mode, Honeywell Air Coolers provide cool, moist air through the evaporation of water. There is a manual Water Regulator knob located in the ice compartment of the unit. This allows you to adjust the amount of water pumped over the Honeycomb Cooling Media, thus helping to control cooling and humidification levels. When the Water Regulator is set to MIN, the water pump distributes a minimal amount of water to the Honeycomb Cooling Media. This results in less water evaporation and reduces the cooling effect. Water Regulator MAX MIN When the Water Regulator is set to MAX, the water pump distributes the maximum amount of water to the Honeycomb Cooling Media. This results in maximum water evaporation and greater cooling performance. REMOTE CONTROL POWER SPEED SWING TIMER COOL NATURAL POWER SPEED COOL SWING TIMER NATURAL : ON / OFF : Low / Medium / High : Controls cooling or fan option : Controls the motion of the louvers : Controls the Timer function for automatic off : Turns on Natural mode Note: The remote control requires AAA (2 x 1.5V) batteries for replacement. Open the battery compartment at the back of the remote control and insert the batteries inside. Care must be taken to insert the batteries according to the correct polarity (+ / ) markings shown inside the battery compartment. Always point the remote control signal transmitter towards the unit when operating. Make sure that the signal path is not obstructed. Remove the batteries if the unit is not going to be used for an extended period of time. Do not drop the remote control. Do not mix different types of batteries such as alkaline, carbon-zinc, or rechargeable batteries. EN 2

USE & OPERATION (CONTINUED) REMOTE CONTROL (CONTINUED) Do not mix old and new batteries. Do not recharge the battery. Exhausted batteries are to be removed from the product and safely disposed of as per local regulations. Do not dispose of batteries in fire. Batteries may explode or leak. WARNING: Caution for ingestion of the small battery. Keep away from children and animals. COOLER LOCATION Make sure to position the air cooler correctly before you set up and start using the product. Please refer to the COOLER LOCATION section of the separate Safety & Maintenance Guide. FILLING WITH WATER CAUTION: Unplug the unit from the electrical power outlet before emptying or refilling the water tank. Open the Water Fill Door located on the side of the unit. The Water Level Indicator is located at the side of the unit. Refill the water tank when water level is low. Do not fill water above the "Max." water level mark to avoid water droplets collecting on the louvers. Check the water level in the tank before running the COOL function. Make sure that the water in the tank is above the minimum water level mark. Running the unit in COOL mode with inadequate water may cause pump failure. Note: The water capacity refers to the total volume of water that can be contained within the air cooler water tank and water distribution system. The water capacity in the tank at the Max. indicator level may be lower than the actual water capacity of the air cooler. Water Fill Door Ice Compartment Note: If ice is available, you may add ice in the top ice compartment to enhance the cooling performance. WARNING: Do not fill water tank with dirty water or salt water. This can damage the unit and Honeycomb media. LOW WATER ALARM The unit is equipped with a low water sensor. In Cooling Mode, when water in the tank is below the minimum level, you will hear a beeping sound and the will flash continuously. The unit will automatically pause evaporative cooling. Refill the water tank to deactivate the alarm in cooling mode. First switch OFF the unit and unplug from the power outlet. Fill the water tank with water above the minimum water level mark. Plug in and switch ON again. To deactivate the alarm and continue using the unit as a fan (without evaporative cooling), switch the unit OFF and then ON again. The Low Water Alarm will not activate in Fan only mode. The Low Water Alarm will sound again if the COOL function is activated while the water tank is still empty. EN 3

USE & OPERATION (CONTINUED) CLEANING & DRAINING THE WATER TANK Below are instructions on how to clean and maintain your air cooler. If the cooler will not be used for a long period of time, please refer to the STORAGE & MAINTENANCE GUIDELINES located in the separate Safety & Maintenance Guide. WARNING: Before cleaning the unit, switch the unit OFF and disconnect from the electrical socket. Move the unit to a location where the water can be drained. Remove the cap from the Drain plug located at the bottom of the unit. Allow the tank to empty. Refill the water tank with clean water and drain it completely. Refill the water tank with clean water, up to the maximum level. Use a damp cloth to remove the dirt and dust from the surface of the unit. Never use corrosive elements or chemicals to clean this product. When the product is not in use, store the unit in a dry place out of direct sunlight. CLEANING THE CARBON DUST FILTER* AND HONEYCOMB COOLING MEDIA The appliance is supplied with a Carbon Dust Filter* & Honeycomb Cooling Media. The Carbon Dust Filter* and Honeycomb Cooling Media are located inside the Rear Grill. See Figure 1 for instructions on how to remove them from the unit for cleaning and maintenance. Do not run the unit in COOL mode with stale water in the tank. You must empty the water tank and refill with fresh water, especially if the tank has not been cleaned in a long time. The cleaning frequency for the Honeycomb media depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow. Draining the water tank and refilling with fresh water at least once a week will help reduce mineral deposits. If mineral deposits remain on the Honeycomb Cooling Media, the media should be removed and washed under fresh water. The media should be cleaned every two months or sooner, depending on your needs. For best results allow the Honeycomb Cooling Media to dry after each use by turning off the cool function 15 minutes before turning the unit off. Figure 1: Honeycomb Cooling Media Honeycomb Frame Carbon Dust Filter Removing the Carbon Dust Filter*/ Honeycomb Cooling Media: Rear Grill Horizontal Bar 1. Remove all the screws from the Rear Grill of the Air Cooler. 2. Carefully pull out the rear grill from the cooler. 3. Slide out the Carbon Dust Filter* and clean with water. 4. The Honeycomb Cooling Media is secured on the Honeycomb Frame by a Horizontal Bar that is fixed in place by two screws. Remove these two screws to release the Horizontal Bar and slide the Honeycomb out of the frame. 5. Replace or clean media with water and a damp cloth as needed. WARNING: DO NOT operate the Air Cooler when the Rear Grill or Honeycomb Frame is removed from the Air Cooler, or if there is a loose-fitting Rear Grill or Honeycomb Frame. Doing so can cause serious injury or dangerous electrical shock. *Applicable for models with Carbon Dust Filter only. EN 4

TECHNICAL SPECIFICATIONS Model CO30XE Voltage 110-120V Frequency 60Hz Ampere 2.4A Wattage 288 W Cooling Media Honeycomb Product Dimension 458 (W) x 352 (D) x 856 (H) mm 18.0 (W) x 13.8 (D) x 33.7 (H) in Net Weight 11.3 kg / 24.9 lbs ELECTRICAL WIRING DIAGRAM For USA Outdoor Models Only. This appliance is equipped with a GFCI plug. Press the TEST button and then the RESET button once every month to ensure proper operation. Version: 110-120V/60Hz BU

JMATEK North America LLC Mahwah, New Jersey 07495 USA Phone: 1-800-474-2147 Email: usinfo@jmatek.com Web: www.jmatek.com 2016 JMATEK Limited. All rights reserved. The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representations or warranties with respect to these products. This product is manufactured by Airtek Int'l Corp. Ltd. (subsidiary of JMATEK Ltd.)