Watson Home Inspection Services, LLC.

Similar documents
Space Coast Home Inspections LLC

Axiom Property Inspections

Inspector Gadget Homes

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

MHI Services Inc. Property Inspection Report

Coast Home Inspection

Extra Mile Inspection, Inc.

Troy's Home Inspection Services LLC

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

Inside Out Home Inspections

Cascade Inspection Services, LLC

Bayshore House Inspections LLC

Jeff Brown Inspections

All In One Home Inspections

Hearth and Homes Inspections, llc

SPS Home Inspections, LLC

Tennessee Valley Property Inspections

Canadian Property Inspections

Final Phase Inspection

FAIRA TRANSPARENCY REPORTS. November 21, 2016

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

FAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017

FAIRA TRANSPARENCY REPORTS SE 265th St, Covington, WA October 10, 2017

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032

FAIRA TRANSPARENCY REPORTS NE 117th Pl, #F8, Kirkland, WA 98034

FAIRA TRANSPARENCY REPORTS S 248th Pl, Des Moines, WA March 12, 2018

RW West Consultants. Property Inspection Report

Bay Wide Commercial and Home Inspection Thackeray Avenue/ Mail address Hayward, Calif TH AVENUE SAN LEANDRO, CALIFORNIA

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017

FAIRA TRANSPARENCY REPORTS th St SE, Lake Stevens, WA June 14 th, 2017

FAIRA TRANSPARENCY REPORTS Alaskan Way, 514, Seattle, WA 98101

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275

FAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017

FAIRA TRANSPARENCY REPORTS nd Ave S, E-2, SeaTac, WA 98198

Excellent Home Inspection Services, LLC

Amendment to the Inspection Report

FAIRA TRANSPARENCY REPORTS rd Pl SE, Maple Valley, WA April 4 th, 2017

FAIRA TRANSPARENCY REPORTS. November 21, 2016

FAIRA TRANSPARENCY REPORTS. March 14 th, 2017

FAIRA TRANSPARENCY REPORTS st Pl SE, Sammamish, WA May 18 th, 2017

FAIRA TRANSPARENCY REPORTS th Dr NE, Lake Stevens, WA April 4th, 2017

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave S, A304, Des Moines, WA March 13, 2018

FAIRA TRANSPARENCY REPORTS. January 27 th, 2017

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

FAIRA TRANSPARENCY REPORTS SE 279th St, Maple Valley, WA March 7, 2018

FAIRA TRANSPARENCY REPORTS NE 178th St, Lake Forest Park, WA May 2 nd, 2017

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109

FAIRA TRANSPARENCY REPORTS SE 240th Pl, Maple Valley, WA June 5th, 2017

Inspector FX Field Forms

FAIRA TRANSPARENCY REPORTS W Manor Pl, #413, Seattle, WA August 25, 2017

FAIRA TRANSPARENCY REPORTS nd Ave SW, Burien, WA October 26 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave S, Auburn, WA June 15 th, 2017

Inspection Report 123 My Street Midland, GA

Michael Newell Consulting

FAIRA TRANSPARENCY REPORTS th Ave SE, Bothell, WA 98012

FAIRA TRANSPARENCY REPORTS Highland Dr, Bellevue, WA 98006

FAIRA TRANSPARENCY REPORTS. July 6, 2016

FAIRA TRANSPARENCY REPORTS Spruce Way, Lynnwood, WA August 21, 2017

FAIRA TRANSPARENCY REPORTS th St SW, 301, Lynnwood, WA May 31 st, 2017

FAIRA TRANSPARENCY REPORTS Stone Ave N, #205, Seattle, WA 98133

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

BISHOP HOME INSPECTIONS, LLC. Phone (269) / Fax (269) / Website: bishophomeinspection.

FAIRA TRANSPARENCY REPORTS S 284th Ln, #H204, Federal Way, WA March 12, 2018

FAIRA TRANSPARENCY REPORTS th Ave N, Edmonds, WA January 19 th, 2018

John Sample. Property Address: 123 Main St. Alpharetta GA Inspector: Jason David. Residential Inspector of America, Inc.

FAIRA TRANSPARENCY REPORTS th Ln NE, Issaquah, WA February 1, 2018

FAIRA TRANSPARENCY REPORTS NE 108th St, Redmond, WA April 4 th 2017

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

FAIRA TRANSPARENCY REPORTS S 272nd St, #39, Kent, WA September 1 st, 2017

FAIRA TRANSPARENCY REPORTS th Ave SE, Renton, WA June 13 th, 2017

FAIRA TRANSPARENCY REPORTS Wells Ct S, Renton, WA 98055

26632 Timberlane Dr SE, Covington, WA 98042

FAIRA TRANSPARENCY REPORTS Fairview Ave E, #304, Seattle, WA June 7 th, 2017

FAIRA TRANSPARENCY REPORTS W Villa Monte Dr, Mukilteo, WA August 8 th, 2017

McKinney Inspection Company

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS Harbour Pointe Blvd, #301h, Mukilteo, WA 98275

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)

Patriot Home Inspections

Canadian Property Inspections

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS th St SE, #13A, Auburn, WA January 25, 2018

FAIRA TRANSPARENCY REPORTS SE 41st Ln, E203, Bellevue, WA April 7 th, 2017

Property Description: (1) level condominium in a multi-story building Property age/ size: Built 2006, 1,137 s.f. per listing Occupancy Status: Vacant

FAIRA TRANSPARENCY REPORTS th Pl SE, Covington, WA May 17 th, 2017

Home Inspection Report

FAIRA TRANSPARENCY REPORTS NE 116th Pl, Kirkland, WA April 20 th, 2017

FAIRA TRANSPARENCY REPORTS. 706 N 103rd St, Seattle, WA August 14, 2017

FAIRA TRANSPARENCY REPORTS Bothell Everett Hwy, D304, Bothell, WA February 6, 2018

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015

FAIRA TRANSPARENCY REPORTS. February 28 th, 2018

FAIRA TRANSPARENCY REPORTS Greenwood Ave N, N304, Seattle, WA March 21, 2018

FAIRA TRANSPARENCY REPORTS S 259th St, Des Moines, WA October 2, 2017

FAIRA TRANSPARENCY REPORTS NE 182nd St, C101, Kenmore, WA 98028

Transcription:

Cover Page Watson Home Inspection Services, LLC. Property Inspection Report 16466 Olalee Rd, Apple Valley Ca., 92307 Inspection prepared for: Jesse Owens & Zona Owens Agent: Ofir Andrews - Hamilton Landon Inspection Date: 4/2/2010 Time: 9:30 Age: 18 years Weather: Clear Front of house faces east Inspector: Thomas A. Watson Phone: (760) 985-7051 Fax: (760) 245-3258

Report Summary Report Summary The summary below consists of potentially significant findings. These findings can be a safety hazard, a deficiency requiring a major expenses to correct or items I would like to draw extra attention to. The summary is not a complete listing of all the findings in the report, and reflects the opinion of the inspector. Please review all of the pages of the report as the summary alone does not explain all the issues. All repairs must be done by a licensed &bonded trade or profession. I recommend obtaining a copy of all receipts, warranties and permits for the work done. Interior Areas Page 4 Item: 13 Fireplace Damper closes all the way. On gas log fire places a stop is required on the flue. Recommend installing a stop to prevent flu from closing. Bathroom Page 8 Item: 13 Showers In the inspectors opinion the faucet in the master bath shower is near the end of its useful life and should be replaced by a qualified professional. Kitchen Page 10 Item: 9 Spray Wand The spray wand did not operate when tested. Page 11 Item: 17 Electrical Outlet damaged/not working on right side of sink. Laundry Page 12 Item: 3 Dryer Vent The dryer vent terminates in the garage. Page 12 Item: 5 GFCI No GFCI protection present, suggest installing GFCI protected receptacles for safety. Water Heater Page 15 Item: 10 Strapping The water heater is not strapped. Garage Page 16 Item: 2 Walls Garage drywall ceiling needs to be properly repaired, an access hole has been cut into the garage ceiling to allow access to the attic. This has compromised the firewall. Recommend a qualified professional repair the ceiling. Page 16 Item: 8 Fire Door There is no self-closing device on the door from the house leading to the garage. It is strongly recommended that one be installed in order to protect the residence against garage originated fires. Electrical Page 18 Item: 1 Electrical Panel The sub panel is bonded. Have licensed electrician evaluate. Grounds Page 24 Item: 4 Grounds Electrical Light above front door did not operate at time of inspection. Page 1 of 26

1. Attendance 2. Home Type 3. Occupancy Inspection Details In Attendance: Client present Client present Buyer Agent present Fully Participated Home Type: Single Family Home Occupancy: Occupied Moderate storage was observed. Page 2 of 26

Interior Areas The Interior section covers areas of the house that are not considered part of the Bathrooms, Bedrooms, Kitchen or areas covered elsewhere in the report. Interior areas usually consist of hallways, foyer, and other open areas. Within these areas the inspector is performing a visual inspection and will report visible damage, wear and tear, and moisture problems if seen. Personal items in the structure may prevent the inspector from viewing all areas on the interior. The inspector does not usually test for mold or other hazardous materials. A qualified expert should be consulted if you would like further testing. 1. Cabinets No deficiencies observed. 2. Ceiling Fans 3. Closets 4. Door Bell Operated normally when tested, at time of inspection. The closet is in serviceable condition. Operated normally when tested. 5. Doors 6. Electrical Missing cover Page 3 of 26

7. Smoke Detectors 8. Window Condition 9. Ceiling Condition 10. Patio Doors 11. Screen Doors 12. Wall Condition 13. Fireplace Operated when tested Materials: Aluminum framed sliding window noted. Materials: There are drywall ceilings noted. The sliding patio door was functional during the inspection. Sliding door screen is functional. Materials: Drywall walls noted. Materials: Family Room Materials: Prefabricated "zero clearance" fireplace noted. Damper was opened and closed several times. Damper closes all the way. On gas log fire places a stop is required on the flue. Recommend installing a stop to prevent flu from closing. Page 4 of 26

Bedrooms The main area of inspection in the bedrooms is the structural system. This means that all walls, ceilings and floors will be inspected. Doors and windows will also be investigated for damage and normal operation. Personal items in the bedroom may prevent all areas to be inspected as the inspector will not move personal items. 1. Locations Locations: Master#1 South East#2&3 North West#4 2. Ceiling Fans 3. Closets Operated normally when tested, at time of inspection. The closet is in serviceable condition. 4. Doors Rod end broken Page 5 of 26

5. Electrical No Arc-Fault Circuit Interrupter (AFCI) protection was installed to protect electrical circuits in bedrooms. Building codes with which new homes must comply require the installation of AFCI protection of all bedroom outlets. This type of protection is designed to detect electrical arcing, which is a potential fire hazard. Although AFCI protection was not required at the time the home was originally constructed, as general knowledge of safe building practices has improved with the passage of time, building standards have changed to reflect current understanding. Consider updating the existing electrical to provide AFCI protection. Arc-fault protection can be provided using either of two methods: 1. Arc Fault Circuit Interrupters (AFCI's) electrical outlets which have this capability built in. 2. AFCI circuit breakers installed at the main electrical panel which provide this protection to all non-afci outlets on the circuit controlled by that AFCI breaker. 6. Floor Condition 7. Smoke Detectors 8. Wall Condition 9. Window Condition 10. Ceiling Condition 11. Patio Doors 12. Screen Doors Flooring Types: Carpet is noted. The smoke detectors operated during the inspection. Materials: Drywall walls noted. Materials: Aluminum framed sliding window noted. Materials: There are drywall ceilings noted. The hinged patio door was functional during the inspection. The seal at the bottom is catching on the carpet and has pulled away, this should be repaired. Page 6 of 26

Bathroom Bathrooms can consist of many features from jacuzzi tubs and showers to toilets and bidets. Because of all the plumbing involved it is an important area of the house to look over. Moisture in the air and leaks can cause mildew, wallpaper and paint to peel, and other problems. The home inspector will identify as many issues as possible but some problems may be undetectable due to problems within the walls or under the flooring.. 1. Locations Locations: Master Bathroom Guest bathroom Full bath 2. Cabinets 3. Ceiling Condition 4. Counters 5. Doors 6. Electrical 7. GFCI 8. Exhaust Fan 9. Floor Condition 10. Heating No deficiencies observed. Materials: There are drywall ceilings noted. Solid Surface tops noted. No major system safety or function concerns noted at time of inspection. No major system safety or function concerns noted at time of inspection. GFCI in place and operational The bath fan was operated and no issues were found. Materials: Carpet is noted. Ceramic tile is noted. Central heating and cooling noted in this room. At the time of the inspection, all appeared to be functioning and in serviceable condition. 11. Mirrors Page 7 of 26

12. Plumbing 13. Showers 14. Shower Walls Faucet needs to be replaced In the inspectors opinion the faucet in the master bath shower is near the end of its useful life and should be replaced by a qualified professional. Caulking needed around perimeter. Caulking needed around perimeter. Water damage Page 8 of 26

15. Bath Tubs 16. Enclosure Caulking needed around perimeter. The shower enclosure was functional at the time of the inspection. 17. Sinks 18. Toilets 19. Window Condition Materials: Aluminum framed sliding window noted. Page 9 of 26

Kitchen The kitchen is used for food preparation and often for entertainment. Kitchens typically include a stove, dishwasher, sink and other appliances. 1. Cabinets No deficiencies observed. 2. Counters 3. Dishwasher 4. Garbage Disposal 5. Cook top condition 6. Oven & Range No discrepancies noted. operated Operated - appeared functional at time of inspection. Electric cook top noted. All heating elements operated when tested. Oven(s) operated when tested. 7. Sinks 8. Drinking Fountain 9. Spray Wand The spray wand did not operate when tested. 10. Hot Water Dispenser 11. Soap Dispenser Page 10 of 26

12. Vent Condition 13. Window Condition Materials: Recirculating Recommend cleaning filter regularly for fire safety. Materials: Garden style window noted. 14. Floor Condition 15. Plumbing 16. Ceiling Condition 17. Electrical 18. GFCI Materials: Vinyl squares (tiles) are noted In the inspectors opinion the floor is near the end of its useful life due to. Materials: There are drywall ceilings noted. Outlet damaged/not working on right side of sink. GFCI in place and operational 19. Wall Condition Outlet is broken needs to be replaced Materials: Drywall walls noted. Page 11 of 26

1. Locations 2. Cabinets 3. Dryer Vent Laundry Locations: In the garage area No deficiencies observed. The dryer vent terminates in the garage. 4. Electrical 5. GFCI 6. Gas Valves 7. Floor Condition The dryer vent terminates in the garage. No GFCI protection present, suggest installing GFCI protected receptacles for safety. functional Materials: Bare concrete floors noted. 8. Plumbing Page 12 of 26

Heat/AC The heating, ventilation, and air conditioning and cooling system (often referred to as HVAC) is the climate control system for the structure. The goal of these systems is to keep the occupants at a comfortable level while maintaining indoor air quality, ventilation while keeping maintenance costs at a minimum. The HVAC system is usually powered by electricity and natural gas, but can also be powered by other sources such as butane, oil, propane, solar panels, or wood. The inspector will usually test the heating and air conditioner using the thermostat or other controls. For a more thorough investigation of the system please contact a licensed HVAC service person. 1. Heater Condition Materials: Location: The furnace is located in the garage Materials: Gas fired forced hot air 2. Heater Base 3. Venting 4. Gas Valves 5. Refrigerant Lines The heater base appears to be functional. Metal single wall chimney vent pipe noted. Gas shut off valves were present and functional. No defects found. 6. AC Compress Condition Compressor Type: electric Location: The compressor is located on the exterior grounds. Appeared functional at the time of inspection, however it was not tested due to temp. 7. Air Supply 8. Registers The return air supply system appears to be functional. 9. Filters Location: Located inside heater cabinet. Poor type of filter installed Page 13 of 26

10. Thermostats Digital - programmable type. Page 14 of 26

1. Base 2. Heater Enclosure 3. Combusion Water Heater The water heater base is functional. The water heater enclosure is functional. The combustion chamber appears to in functional condition. 4. Venting 5. Water Heater Condition Heater Type: gas Location: The heater is located in the exterior closet. Tank appears to be in satisfactory condition -- no concerns. 6. TPRV Appears to be in satisfactory condition -- no concerns. 7. Gas Valve functional 8. Plumbing 9. Overflow Condition 10. Strapping Materials: copper No deficiencies observed at the visible portions of the supply piping. Materials: copper Appears to be in satisfactory condition -- no concerns. The water heater is not strapped. Page 15 of 26

1. Roof Condition 2. Walls 3. Anchor Bolts Garage Materials: Roofing is the same as main structure. Materials: Concrete tiles noted. No major system safety or function concerns noted at time of inspection. Garage drywall ceiling needs to be properly repaired, an access hole has been cut into the garage ceiling to allow access to the attic. This has compromised the firewall. Recommend a qualified professional repair the ceiling. 4. Floor Condition 5. Rafters & Ceiling Materials: Bare concrete floors noted. Same as the main house. 6. Electrical 7. Exterior Door Appeared functional, at time of inspection. 8. Fire Door There is no self-closing device on the door from the house leading to the garage. It is strongly recommended that one be installed in order to protect the residence against garage originated fires. 9. Garage Door Condition Materials: Roll-up door noted. Maintenance repairs needed Garage vehicle door hardware damaged or missing. Page 16 of 26

Maintenance repairs needed 10. Garage Door Parts The garage door is missing some of its hardware. We recommend contacting a qualified contractor to repair the door. 11. Garage Opener Status Screw drive opener noted. 12. Garage Door's Reverse Status 13. Ventilation 14. Vent Screens 15. Cabinets Gable louver vents noted. Attic fan appears to be controlled by a thermostat; no operational test was performed. Suggest verification of performance prior to closing. Vent screens noted as functional. No deficiencies observed. 16. Counters 17. Wash Basin Page 17 of 26

1. Electrical Panel 2. Main Amp Breaker Electrical Location: Main Location: South side of the house. Location: Sub Panel Location: Located in the garage. No major system safety or function concerns noted at time of inspection at main panel box. The sub panel is bonded. Have licensed electrician evaluate. 200 amp 3. Breakers in off position 0 4. Cable Feeds 5. Breakers There is an underground service lateral noted. Materials: Copper non-metallic sheathed cable noted. All of the circuit breakers appeared serviceable. Page 18 of 26

1. Roof Condition 2. Flashing 3. Chimney Roof Materials: Inspected from ladder. Materials: Concrete tiles noted. No major system safety or function concerns noted at time of inspection. No major system safety or function concerns noted at time of inspection. 4. Spark Arrestor 5. Vent Caps 6. Gutter No major system safety or function concerns noted at time of inspection. Page 19 of 26

1. Access Access at hallway ceiling Attic 2. Structure 3. Ventilation 4. Vent Screens 5. Duct Work 6. Electrical 7. Attic Plumbing Gable louver vents noted along with dormer vents. Vent screens noted as functional. functional most not accessible due to insullation ABS plumbing vents 8. Insulation Condition Materials: Fiberglass batts with kraft paper facing noted. Loose fill insulation noted. Depth: Insulation averages about 6-8 inches in depth Insulation appears adequate. 9. Chimney 10. Exhaust Vent functional Page 20 of 26

1. Doors 2. Window Condition 3. Eaves & Facia 4. Exterior Paint Exterior Areas Appeared in functional and in satisfactory condition, at time of inspection. Components appeared in satisfactory condition at time of inspection. No major system safety or function concerns noted at time of inspection. Peeling paint observed, suggest scraping and painting as necessary. 5. Stucco Page 21 of 26

1. Slab Foundation Foundation Concrete slab not visible due to floor coverings. 2. Foundation Perimeter No deficiencies were observed at the visible portions of the structural components of the home. 3. Anchor Bolts The anchor bolts were not visible. Page 22 of 26

Grounds 1. Driveway and Walkway Condition Materials: Concrete driveway noted. Driveway in good shape for age and wear. No deficiencies noted. 2. Grading No major system safety or function concerns noted at time of inspection. 3. Vegetation Observations Prune or remove any plants that are in contact or proximity to home to eliminate pathways of wood destroying insects. Prune or remove any plants that are in contact or proximity to home to eliminate pathways of wood destroying insects. 4. Grounds Electrical No major system safety or function concerns noted at time of inspection. Light above front door did not operate at time of inspection. Page 23 of 26

5. GFCI Missing cover GFCI receptacles are in good condition. 6. Main Gas Valve Condition Materials: north side Meter located at exterior. All gas appliances have cut-off valves in line at each unit. No gas odors detected. 7. Plumbing 8. Water Pressure North side of house Materials: Copper piping noted. 50 Page 24 of 26

9. Pressure Regulator Pressure regulator noted. Valve handle broken 10. Exterior Faucet Condition Location: Front of structure North side of house. East side of house Appears Functional. 11. Patio and Porch Condition Materials: Rolled roofing noted. Each hole should have a lag bolt Needs paint Page 25 of 26

Residential Earthquake Hazards Report Yes No N/A Don't Know Yes No N/A Don't Know Yes No N/A Don't Know 1. Is the water heater braced, strapped, or anchored to resist falling during an earthquake? 2. Is the house anchored or bolted to the foundation? 3. If the house has cripple walls: a. Are the exterior cripple walls braced? Yes No N/A Don't Know Yes No N/A Don't Know Yes No N/A Don't Know Yes No N/A Don't Know Yes No N/A Don't Know Yes No N/A Don't Know Yes No Don't Know Yes No Don't Know b. If the exterior foundation consists of unconnected concrete piers and posts, have they been strengthened? 4. If the exterior foundation, or part of it, is made of unreinforced masonry, has it been strengthened? 5. If the house is built on a hillside: a. Are the exterior tall foundation walls braced? b. Were the tall posts or columns either built to resist earthquakes or have they been strengthened? 6. If the exterior walls of the house, or part of them, are made of unreinforced masonry, have they been strengthened? 7. If the house has a living area over the garage, was the wall around the garage door opening either built to resist earthquakes or has it been strengthened? 8. Is the house outside an Alquist-Priolo Earthquake Fault Zone (zones immediately surrounding known earthquake faults)? 9. Is the house outside a Seismic Hazard Zone (zone identified as susceptible to liquefication or landsliding)? EECUTED BY: (Seller) (Seller) Date I acknowledge receipt of this form, completed and signed by the seller. I understand that if the seller has answered ìnoî to one or more questions, or if seller has indicated a lack of knowledge, there may be one or more earthquake weaknesses in this house. (Buyer) (Buyer) Date Page 26 of 26