Construction Heat CH-02 (up to 400,000 BTU) Record of Training Curriculum Document

Similar documents
Gas Safety. Syllabus. For 120kW. Class B gas fitter. Certificate of qualification examination

MOBILE FOOD SERVICE EQUIPMENT FIELD APPROVAL SUBMISSION INFORMATION

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

Gas Safety. Syllabus. For. Gas Appliance Service. Certificate of Qualification Examination. (Formerly Class C)

Practical Skills Sign Off Instrument

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER. Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83.

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER

S150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

THC- 355DF (Dual Fuel)

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

WARNING. SPECIFICATIONS: Completely Self-contained Rain Protected Wind Resistant No Electrical Required WARNING FOR OUTDOOR USE ONLY!

Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches. New

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

7 Hazard assessment 8 Worker participation 9 Hazard elimination and control

TERRACE AND PATIO HEATER HLB-2400/ 2650 SERIES

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

Chapter 12 HOT WORK OPERATIONS. Purpose:

Residential/Commercial Gas Condensing Tankless Models

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference)

Click Here To View Item at

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

Commercial Tankless Rack System

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

CHAPTER 15: FIRE PREVENTION & AWARENESS POLICY

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

Commercial Tankless Rack System

TERRACE AND PATIO HEATER

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

1.0 Basic Principles and Practices of Propane Performance-Based Skills Assessment 2016

Using it in an enclosed space can kill you.

positions, side by side, end to end and Tee configurations. and utility pedestals

High efficiency, cast-iron gas boiler

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

City of Leduc Fire Services Indoor Special Event Requirements

Dashley Outdoor Fire Table

Commercial Tankless Rack System

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES

Completed Projects / Projets terminés

Owner s Manual OUTDOOR LIVING PERFECTED TONGA TORCH PORTABLE PROPANE

WATER-TUBE POOL HEATERS

Repeat procedures for other side.

REGISTRATION EXAMINATION, JUNE 2012 LICENSED GASFITTER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

DIVISION FINNED WATER-TUBE BOILERS

Commercial Tankless Rack System

Combustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO

Fire Prevention Plan

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

PAULIN PRODUCTS INDOOR HEATER

WATER-TUBE POOL HEATERS

REGISTRATION EXAMINATION, NOVEMBER 2016 LICENSED GASFITTER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

Mi-T-M carries a full line of portable heaters, built in the same quality tradition you ve come to expect from us.

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

TERRACE AND PATIO HEATER

Installation Instructions

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

WELDING, CUTTING, AND BRAZING SAFETY PROGRAM

L O S S C O N T R O L

Fire Prevention Plan

Accessories. Safety Shut-off Valves. Certifications. Accessories. ASV375NT Safety Shut-off Valve. Combination Gas Control/Valve

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

FOR YOUR SAFETY FOR OUTDOOR USE ONLY PROPANE GAS. Model No. AH2069ODS, AH2063ODS

CYLINDER NOT INCLUDED

PARAFFIN/DIESEL FORCED AIR HEATERS

OPERATING INSTRUCTIONS AND OWNER S MANUAL

DIRECTIVE NO: D-B

DIVISION FINNED WATER-TUBE BOILERS

ASSEMBLY INSTRUCTIONS

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

TAB. Ventless Ethanol Fireplace. User s Manual

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Liquefied Petroleum Gas Facility Written Fire Safety Analysis

Residential Gas Tankless Water Heater

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

PTO50 Outdoor Decorative Fireplace

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

NATURAL GAS MODELS: SGC-36N/SGC-48N/SGC-60N/SGC-72N SGR-24N/SGR-36N BARBECUE - CARE AND USE

Owner's Manual and Instructions

Transcription:

Introduction: This TSSA document defines the required training curriculum content for CH-02 Record of Training programs under Ontario Regulation 215/01(Fuel Industry Certificates). Ontario Training Providers who wish to have their CH-02 training programs accredited by TSSA must submit training programs that meet with the requirements of this curriculum. There is no requirement to follow the order of this curriculum unless otherwise noted, provided all of the content and objectives are met. Ontario Regulation 215/01 CH-02 certificate 48. A person who is the holder of a CH-02 certificate or the holder of a record of training for the purpose may perform the functions of a CH-01 on a construction heater or torch that has an input of 400,000 Btuh or less. O. Reg. 215/01, s. 48; O. Reg. 253/08, s. 29. CH-01 certificate 47. A person who is the holder of a CH-01 certificate or the holder of a record of training for the purpose may activate a propane, natural gas or oil-fired construction heater or torch with an input of any Btuh, and connect it to or disconnect it from piping, tubing, a refuelling appliance, a container or a natural gas meter. O. Reg. 215/01, s. 47. NOTE: The CH-02 ROT Training Program may be divided into two separate programs if desired: CH-02-T (Torch only) and CH-02-C (Construction Heater only). The Accredited Training Provider and the trainee must understand, prior to establishing the training contract, that a CH-02-T only certifies the ROT car holder to operate propane torches, and that the CH-02-C only certifies the ROT card holder to operate construction heaters. The training provider must indicate, on all ROT cards issued, whether the program met the requirements of the complete CH-02, the CH-02-T or the CH-02-C. Theory testing may be done by module or at the completion of the course. Estimated minimum total number of hours for program delivery: 6 hours Page 1

MODULE 1 Estimated hours:.5 Module Title: Propane; Properties of the Fuel and Related Hazards MODULE 01 01.01 Identify the properties of propane as a vapour and as a liquid as well as the hazards associated with the fuel. Identify the properties of propane as a liquid and as a vapour in terms of: chemical composition (MSDS Information) calorific value boiling and freezing points relative density physical and identifiable characteristics of both liquid and vapour propane uses in industry, home heating and transportation for both liquid and vapour propane expansion between the liquid and vapour states working pressures for appliances Identify the hazardous potential of propane as a liquid and as a vapour frostbite and blinding potential required Personal Protective Equipment for working with propane first aid measures sources of ignition and extinguishing fires carbon monoxide range of flammability explosive potential provide examples of propane related incidents or accidents 01.02 THEORY TESTING Candidates shall perform a written theory test with core elements of each learning objective represented in the test. Page 2

MODULE 2 Estimated hours:.5 Module Title: Legislation and Codes MODULE 02 02.01 Identify the applicable sections of the TSS Act. The TSS Act Identify the role of TSSA in the Fuels Industry and its jurisdictional authority as per the Act 02.02 Identify the applicable requirements of Ontario Regulation 215/01. 02.03 Identify the applicable requirements of Ontario Regulation 212/01. 02.04 Identify the applicable requirements of Ontario Regulation 211/01. Identify the scope of the CH-02 Certificate as per Ontario Regulation 215/01. identify requirement for compliance identify requirement for approval identify the duties of an employer identify the reporting requirements for an accident or occurrence identify the requirements for immediate and nonimmediate hazards identify the duty to maintain equipment in a safe operating condition identify the requirements for regulated activities involving propane identify the duties of an employer identify the certificate required for the handling of propane and the certificates required for various activities involving propane 02.05 THEORY TESTING Candidates shall perform a written theory test with core elements of each learning objective represented in the test. Page 3

MODULE 3 Estimated hours:.5 Module Title: Storage and Handling of Propane Cylinders MODULE 03 03.01 Identify various types of cylinders, their components, markings etc. 03.02 Identify the requirements for safe handling of propane cylinders. 03.03 Identify the B149.2 code items for the storage of cylinders. identify various cylinder types and sizes used for construction purposes identify and describe the construction and component parts of cylinders including valve types, relief valves, fixed liquid level gauge, dip tube identify the required Transport Canada date code and markings on cylinders and the requirement for 10 year recertification identify the requirements for cylinder inspection Identify acceptable and unacceptable methods of transporting and moving cylinders Identify the Code requirements for the location of cylinders on construction sites Including: maximum number of cylinders in a manifold, clearances, storage of empty and full cylinders when not in use 03.05 THEORY TESTING Candidates shall perform a written theory test with core elements of each learning objective represented in the test. Page 4

MODULE 4 Estimated hours: 1.5 Module Title: Appliance and Cylinder Connections MODULE 04 04.01 Demonstrate procedures for connecting cylinders and appliances. identify a variety of common, approved fittings, regulators, hoses and pig tails used to connect propane cylinders in the construction industry demonstrate connection methods for manifolding cylinders, connecting to construction heaters, connecting to torches demonstrate leak testing methods 04.02 THEORY TESTING Candidates shall perform a written theory test with core elements of each learning objective represented in the test. Page 5

MODULE 5 Estimated hours: 2-3 Module Title: Appliance Types and Safe Operation MODULE 05 05.01 Identify and select appropriate construction heater. 05.02 Identify the relevant sections of the B149.1 Natural Gas and Propane Installation Code as they pertain to propane fired construction heaters under 400,000 BTU 05.03 Identify and select appropriate propane fired torches. identify various types of construction heaters under 400 000 BTU: Direct, Indirect, Radiant, Portable and the application types for each identify key components of various construction heater types: gas valves, flame safeguards, igniters, controls review manufacturer s instructions for lighting and operating various construction heaters identify the requirements for complete combustion identify the requirements for combustion air, venting and associated hazards Identify CSA B149.1 Section 7 Code Requirements for Operating Construction Heaters under the following criterion: installation combustion air supply (as per manufacturer instructions) duties of users of construction heaters identify typical propane fired torches; one each of the flame safeguard type and that without the flame safeguard. identify the differences between the two types identify the appearance and operational characteristics of a thermocouple flame safeguard system identify the code requirements for operating a the flame safeguard equipped torch vs a torch not equipped with the flame safeguard 05.04 THEORY TESTING Candidates shall perform a written theory test with core elements of each learning objective represented in the test. Practical 05.05 Light construction heaters and safely operate according to manufacturer s instructions. 05.06 Safely light and operate construction torch according to manufacturer s instructions Candidates shall be tested on safe lighting, shutting down and operation of construction heaters, identifying characteristics of complete and incomplete combustion. demonstrate burner adjustment and procedures to follow when problems are detected Candidates shall be tested on safe lighting, shutting down and operation of construction heaters, identifying characteristics of complete and incomplete combustion. demonstrate burner adjustment and procedures to follow when problems are detected Page 6