Unity DAU Voice Alarm System

Similar documents
CFDAU30 Voice Alarm System

Distributed Amplifier Unit (DAU) (EESDAU100) Emergency Microphone All Call (EMA) (EESEMA) User Operational & Maintenance Manual

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

16 Zone Voice Evacuation VA & PA Sound System

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

PREMIER EVACS 1-16 INSTRUCTION MANUAL: 2-ZONE NETWORKED VOICE ALARM PANEL INSTALLATION MANUAL

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

New Silent Alert Fire Safe System

Installation, Operating and Maintenance Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Installation and user manual for the BiWire / Conventional Repeater Panel

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Control Panel Engineering and Commissioning Instructions

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FIRE ALARM CONTROL PANEL FVC01-08

Intelligent Security & Fire Ltd

USER MANUAL & MAINTENANCE GUIDE OG OO

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Surveyor Envoy-MINI 4

SECURIT 700L PLUS ENGINEERING MANUAL

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Silent Alert Fire Safe System

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

5000 INSTALLATION GUIDE

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Fact File 75. Published Document PD CEN/TS 54-32:2015 Fire detection and fire alarm systems

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

Deaf & Hearing Impaired RadioLINK Alarm System

The EN54 Part 2 and 4 Fire System

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Intelligent Security & Fire Ltd

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Fire Safety Register

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-5

Control Panel User Guide

Conventional Fire Alarm System 2014 V1.2

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

installation & maintenance manual LPCB APPROVED CFP 2/4/8 ZONE FIRE ALARM CONTROL PANEL approved document no. DFU rev 5

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-9

June 10, 2002 DF C S2424

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Fire Alarm Control Panel. System Maintenance and Log Book

Application, Installation, Operation & Maintenance Manual

PROFYRE C8 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

OPERATION AND INSTALLATION MANUAL

Entero Voice Alarm system.

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

OmniCare EVC System. Installation & Commissioning Manual

Smoke Vent Control Panel PCB4 V4 Installation Manual

Model 17A00 Expansion Enclosure

Entero Voice Alarm system. User guide

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

July 14, 1999 DF C-100.

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

FIRE ALARMS EMERGENCY LIGHTS NURSE CALL ACCESS CONTROL GK FIRE & SECURITY LTD, UNIT 1 GREBE RD, PRIORSWOOD IND EST, TAUNTON, TA2 8PZ

IEC Electroacoustic EMERGENCY WARNING SYSTEM. for a maximum of system security 79

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER)

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Vocia VACIE. Reference Guide

OPERATING INSTRUCTIONS VOICE EVACUATION SYSTEM FS-7000 SERIES

STROBE / SOUNDER INTERFACE

VACIE REFERENCE GUIDE REVISION 1.2.6

Excel-EN Conventional Fire Control Panel

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

System 800 Addressable Fire Detection & Alarm System

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

INSPECTION AND TESTING FORM

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Door Release Power Supply

Transcription:

Unity DAU Voice Alarm System User Manual & Log Book Site Name Address Contractor Commissioned

Introduction Voice Alarm (VA) systems are the quickest way to evacuate the public & staff from a building. Following fire detection, automated messages control the flow of people in stairwells and corridors allowing an orderly evacuation without panic. These messages are supplemented by spoken messages from the fire service or management suite confirming the validity and need to leave the building. This positive confirmation speeds evacuation and avoids the "false alarm" mentality reducing the risk of death from fire. Suitability Voice Alarm systems are recommended for all public buildings and multi story buildings over four floors by BS5588. In public buildings it's not possible to fire drill the public, as they visit the premises infrequently, so systems such as Voice alarms save valuable time in evacuating the building. The use of phased messages in multi-story buildings prevents over-crowding in stairwells and at exits, preventing secondary injuries. In phased evacuation, the floor in fire receives the evacuate message, and the floor above & below receive an alert message, preparing them for evacuation. In more complex scenarios the use of multiple alert and evacuate messages can be beneficial, messages telling the evacuees they are going the right way, and messages asking people to make way for people leaving evacuated areas. These additional messages can dramatically speed up the evacuation especially in malls and large airport environments. Product Overview Unity has been developed to replace talking sounders in many voice alarm applications, and is available in several forms. The DAU is a complete VA system in a single wall mount box which is complete with messages, fire interface, dual 30W monitored amplifiers, power supply, monitored battery charger and the ability to connect non monitored paging and music directly. The DAU has been developed to draw the minimum of current in standby conditions and mutes the music when the AC supply fails, the unit then draws 60mA quiescent current allowing the use of 3.2AH commodity SLA batteries for full compliance with BS5839 part 8. Connection to fire alarm systems could not be simpler; Unity DAU has independent Alert and Evacuate inputs, which can be connected to reverse monitored sounder circuits directly. Once activated the fire signals need to be de-latched by the reset input, for retrofit to systems with relays a protected 24V aux supply is available. The speaker lines are monitored using a low current DC system, which is continuous, and works with the music playing. Faults reported are open, short and earth faults. Each speaker fitted to Unity DAU must have a DC blocking capacitor fitted. The use of DC monitoring allows all cable types (MICC and soft skin) to be used with the system. Music sources can be plugged directly into the DAU, and the level of this can be set using a remote DC volume control. When used with a paging microphone, the music ducks and restores gently after paging. Document DCC UND 7002-01 Rev 1 June 2005 Page 2 of 10

Priorities The Unity DAU has six fixed priorities for the inputs as follows:- 1. Fire Microphone, this is the highest priority input on the system, designed to be used by the controlling officer. 2. Message Generator, this has three messages, all messages latch until reset from either the front panel recessed button, or from the cancel button on the fire microphone or by the RESET input from the Fire alarm input. Messages are prioritised in the following order: a. EVAC- Triggered from the fire alarm interface or from the fireman s microphone, top priority message. b. ALERT- Triggered from the fire alarm interface or from the fireman s microphone, second priority message. c. TEST- Triggered from the front panel or from the fireman s microphone, this is the lowest priority message. 3. Page Input, this is the fifth priority input, designed for non-emergency functions such as reception paging. 4. Music Input, this is the lowest priority input and automatically selected when no other input is exerting a priority, if not used turn the level control on the front panel fully anticlockwise. Operation The Unity DAU is fully automatic in operation; the only user controls available once the unit has been commissioned are the front panel Reset and Test buttons. Pressing the test button will broadcast the test message to the speaker circuits and latch until the Reset button is pressed. The Unity DAU has fully compliant fault monitoring when correctly installed and commissioned, if any status indicators are illuminated YELLOW (except the Message ACCESS Led) call service to investigate the cause of the fault, this should be indicating a Sounder or Voice alarm fault on the Fire Alarm Panel. Maintenance. It is a requirement of BS5839pt8 that a maintenance agreement be in place for Voice Alarm systems, the maintenance schedule should be as follows. Weekly: Monthly: Quarterly: Yearly: Broadcast the test message to all zones, and check speaker operation, microphones should be checked for operation if fitted, record results in the site log. Trigger the fire alarm system when the building is empty and check the Evacuate message broadcasts, record results in the site log. Engineer Call to check system operation. Engineer Call to check system operation and check Battery Health. 5 Yearly: Engineer Call to check system operation and replace the batteries. Document DCC UND 7002-01 Rev 1 June 2005 Page 3 of 10

Indications and Controls Supply Section Indicators AC Indicates healthy AC mains available. DC Indicates the battery supply is available. Fault Either the AC supply or DC supply is unavailable, or a fuse has ruptured. Amplifier Section Indicators (both channels are identical and independent) Open Short Earth Access Section. Fire Mic Message Paging Music The DAU cannot see both end of line resistors for this amplifier channel. The DAU has detected a short on this amplifier channel. The DAU has detected an earth fault on this amplifier channel. Lights green when the fireman s microphone is activated. Lights when a stored message is playing, Green for test, Yellow for the Alert Message and RED for the Evacuate message. Lights green when the paging microphone is in use. Lights green when the music channel is open, (no other inputs in use). Test Reset Fault Section. General Fire Mic Message This is a recessed push button, pressing this starts the test message broadcasting to the speakers. This recessed push button cancels any message playing (this will not cancel messages triggered from the fire alarm if the trigger is still active) the message always plays to the end of the current cycle once Reset. This lights when the DAU detects any fault in its operation. Lights if there is any fault with the fireman s microphone or cables to the microphone. Lights if the message store in the DAU has detected a corruption. Level Controls Fire Mic Message Page Music Sets the Level of the fireman s Microphone, capped after commissioning. Sets the level of the stored messages in the Unity DAU, capped after commissioning Sets the level of the paging microphone input to the DAU Sets the level of the music to the Speakers. Document DCC UND 7002-01 Rev 1 June 2005 Page 4 of 10

Important Safety Information This Equipment must only be installed and maintained by suitably skilled and competent person. This Equipment is defined as Class 1 in EN60065 (Low Voltage Directive) and must be EARTHED. CAUTION WARNING WARNING WARNING WARNING INDOOR USE ONLY SHOCK HAZARD- ISOLATE BEFORE OPENING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE THIS UNIT MUST BE EARTHED NO USER SERVICABLE PARTS Each exchange unit requires a 3A spur, returning to a breaker clearly marked Voice Alarm DO NOT TURN OFF. If the units are distributed around a site it is essential all units are on the same mains phase, as they are classified TEN 230V, powering from different phases can mean a 440V potential can be present in a unit during a major fault incident. Anti-static handling guidelines Make sure that electro-static handling precautions are taken immediately before handling PCBs and other static sensitive components Before handling any static-sensitive items, operators should get rid of any electrostatic charge by touching a sound safety earth, such as a radiator. Always handle PCBs by their sides and avoid touching any components. PCBs should be stored in a clean, dry place that is free from vibration, dust and excessive heat. Storing the PCBs in a suitable cardboard box will also guard them against mechanical damage. Document DCC UND 7002-01 Rev 1 June 2005 Page 5 of 10

Batteries The Unity DAU requires 2 number 12V 3.2AH sealed lead acid batteries to provide backup power in the event of mains failure as defined in BS5839pt8 for 24 hours standby and 30 minutes operation. For 72hour standby and 1 hour operation 2 number 12V 17AH batteries are required, these will need to be fitted in an external battery enclosure, the monitored charger in the Unity DAU is capable of charging and monitoring these batteries. Safety Information: Sealed Lead acid batteries contain sulphuric acid which can cause burns if exposed to the skin, the low internal resistance of these batteries means large currents will flow if they are accidentally short circuited, causing burns and a risk of fire- exercise caution when handling batteries. Power Up Procedure: Always apply mains power before connecting batteries, do not commission Unity DAU on batteries, as the high inrush current required by the power supply may rupture the battery fuse. Always connect the Positive (Red +) terminal first. Power Down Procedure Disconnect the batteries before removing the mains power; always remove the negative (Black terminal) first. Caution Speaker circuits carry 100V AC Disconnect before servicing to prevent Shock hazards Speaker Circuits on Unity are DC monitored. Suitable speakers for Unity MUST have a thermal fuse to disconnect the speaker if it is in the area in fire and a DC blocking capacitor fitted, typically the capacitor is 2.2uF 250V DC. NOTE! If music is to be broadcast on the Unity DAU an appropriate PRS Licence should be obtained within the UK. The Unity DAU is designed and manufactured in the UK by Current Thinking Ltd, Unit 91 Silver Briar Enterprise Park East, Sunderland, SR5 2TQ. www.current-thinking.com info@current-thinking.com Document DCC UND 7002-01 Rev 1 June 2005 Page 6 of 10

Certificate of Commissioning for a Unity DAU Voice Alarm System to BS5839 pt 8 (1988) and BSEN60849 (1988). Site Name Address Contractor Address Areas Covered In accordance with 28.6 of BS 5839 : Part 8 : 1998, the installation has been inspected and been found to be in accordance with the recommendations of this code except for the following: In accordance with 28.6 of BS 5839 : Part 8 : 1998: a) subclause 28.3, the insulation of cables and wires has been tested, b) subclause 28.4, the earthing has been tested, and c) subclause 28.5, the entire system has been tested for satisfactory operation. The system is accepted in good working order and, in accordance with BS5839: Part 8, 1988, record drawings, operating instructions and a system log book have been supplied and received. Attention has been drawn to the recommendations concerning user's responsibilities, particularly those concerned with routine attention and test procedures. Engineer Date Position Signature: Document DCC UND 7002-01 Rev 1 June 2005 Page 7 of 10

Site Specific Information: Fire Microphone Location Fire Alarm Panel Location Paging Microphone Location Music Source Location Remote Volume Location Speaker Circuits Cable ID Circuit Area Served Power 1A (W) Earth (Ω) End of line Location 2A 1B 2B Document DCC UND 7002-01 Rev 1 June 2005 Page 8 of 10

Log Book Page 1 Date Event or Work Done Engineer Company Signature DAU commissioned Document DCC UND 7002-01 Rev 1 June 2005 Page 9 of 10

Log Book Page Date Event or Work Done Engineer Company Signature Copy this page as many times as required Document DCC UND 7002-01 Rev 1 June 2005 Page 10 of 10