Make-Up Air Systems. Performance. Model DGK, DG, DGX

Similar documents
Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

Indirect Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Models DG and DGX

Modular Supply Make-Up Air Unit

Modular Heating & Ventilating Unit Model IGX-HV

Make-Up Air March 2012

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Direct Gas-Fired Make-Up Air

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Energy Recovery with Cooling and Heating Model ERCH

Energy Recovery with Cooling and Heating

FEATURES AND BENEFITS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air

Direct Fired Heater Model AD Specification

Gas-Fired Indoor and Outdoor Duct Furnaces

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

All the products you need for. Engineered Kitchen Ventilation Systems.

LARGE CAPACITY HEATERS

62DA,DB,DC,DD,DE,DF07-38

Utility and Centrifugal

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

PACKAGED HVAC EQUIPMENT CATALOG

Air Make-Up Units. Product Line Overview & Capabilities

GLOBAL FINISHING SOLUTIONS

The H Series. Pure and Simple Solutions. HTLV Space Heating

Installation, Operation and Maintenance Manual

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

Air Replacement Systems

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

Part # Energy Recovery Ventilators. Model ERCH-HP. General Safety Information

Gas-Fired Indoor and Outdoor Duct Furnaces

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

Installation, Operation and Maintenance Manual **FOR YOUR SAFETY**

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data Performance Data Electrical Data

Desiccant Dehumidifier

Vertical Stack Water Source Heat Pumps

Air Replacement Systems

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

SKYPAK II, 3 Ton Series, gives you a

Installation, Operation and Maintenance Manual

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

THE ULTIMATE ROOFTOP SOLUTION

Air-Handling System Cooling Options

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

SKYPAK II, 3 Ton Series, gives you a

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

for MODEL KSU MAKE-UP AIR UNITS

MSYS 4490 AC Systems

The ultimate fresh air solution.

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

HARTZELL. Tempered Air Heating Equipment. Hartzell Fan, Inc., Piqua, Ohio

Directflow SBDR/SBD SERIES

Installation, Operation and Maintenance Manual

THE RIGHT SPEC. RIGHT NOW.

MODEL PVF INDIRECT GAS FIRED FURNACES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

E-Series Rooftop Units 60 HZ

Would You Bolt A Swamp Cooler To Your DX Rooftop Unit? [not exactly.]

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

GREEN REFRIGERANT R-410A

Installation, Operation and Maintenance Manual

KIC Air Curtains. Technical Guide

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

MODEL DG / DGX (Direct Spark)

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

TYPICAL CPA SPECIFICATIONS

Air-Handling System Cooling Options

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

DCG Commercial. Submittal Data Form

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

48TF GAS HEATING/ ELECTRIC COOLING UNITS

VariCool VAV Engineering Guide

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

PREEVA air handling unit

Installation, Operation and Maintenance Manual

Dry desiccant dehumidification systems. Product guide

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Directflow SBDR/SBD SERIES

MECHANICAL PRODUCTS VOLUME 9

XeteX, Inc. All Rights Reserved.

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

Transcription:

DGK, DG, DGX 96 Make-Up ir Systems Direct Fired Gas Heat DGK-15-25 DG-10-20 -30 DGX-12-22 -32 *DGX with PDX-12-22 -32 est vailable Program 5 Days 10 Days 15 Days * est vailable based on size and capacity DGK, DG and DGX Direct Gas-Fired The DGK, DG and DGX are designed to provide heated make-up air for commercial and industrial applications. The ETL Listed direct gas-fired burner provides a 92% efficient heating system. Installation may be stand-alone or as a combination package with exhaust fan on a common curb. Performance Capacity is 15,000 cfm with up to 2 in. wg static pressure. Heating capacity up to 1,600,000 tu/hr available. Optional Evaporative Cooling - DG and DGX The evaporative cooling section includes a galvanized steel housing with a louvered intake, 2-inch aluminum mesh filters and a stainless steel evaporative cooling module. The evaporative cooling media is Munters CELdek and has a depth of 12 inches for 90% cooling effectiveness. Optional Packaged Direct Expansion (PDX) - DGX only The packaged DX cooling option is designed to cool the kitchen makeup air to a 70-75ºF supply air condition to improve space comfort and enhance employee productivity at an economical first cost. The PDX option includes integral condenser fans, condenser and evaporator coils, thermal expansion valves, and compressors. Standard Construction DGK DG DGX Galvanized steel construction Control center with starter and disconnect Vibration isolation Factory-wired and tested Options and ccessories DGK DG DGX V-bank filters irdscreen weatherhood luminum mesh filtered weatherhood Louvered weatherhood Thru-wall installation 100% outdoor air 80/20 recirculation Variable air volume Discharge temperature control Discharge temperature control with room override Discharge temperature control by external DDC signal Network interface Remote panel Evaporative cooling Packaged direct expansion (PDX) Outdoor air damper Discharge damper Duct liner insulation Double-wall construction Exhaust fan starter Dirty filter sensor Freeze protection Inlet air sensor Variable frequency drive (VFD) Service receptacle uxiliary contacts Gas pressure regulator Roof curb Duct adapter www.greenheck.com Commercial and Industrial Make-Up ir

Combination Packages DG, DGX The Greenheck combination kitchen package simplifies installation and reduces field labor costs. The preengineered design ensures that the supply fan, exhaust fan, curb and combination extension components interface properly. Equally important, Greenheck combination packages are specifically designed to comply with NFP 96. DGK, DG, DGX * maximum 10 ft. min. Combination Package - rrangement DC rrangement DC * Width H10 185.7 35.5 DG H20 204.8 50.0 H30 227.0 58.8 H12 178.5 35.4 DGX H22 243.4 50.0 H32 268.9 65.1 ll dimensions are in inches and include a weatherhood and 2-inch filter section. *ased on largest available CUE exhaust fan. Stand-lone rrangements DGK, DG, DGX The DGK, DG and DGX are available for either downblast (rrangement D) or horizontal (rrangement HZ) discharge. n upblast discharge (rrangement U) is also available on the DGX. Downblast Discharge - rrangement D rrangement D/HZ Width DGK H15 107.4 29.8 31.4 H25 136.0 39.0 49.5 H10 132.3 33.8 28.0 DG H20 148.8 33.8 37.0 H30 162.9 42.5 48.0 H12 131.5 39.0 33.7 DGX H22 174.2 44.9 44.1 H32 191.5 48.7 53.1 ll dimensions are in inches and include a weatherhood and 2-inch filter section. 97 Horizontal Discharge - rrangement HZ Thru-Wall Installation DGX The DGX is available with a pre-engineered, thru-wall installation option, which is ideal when roof penetration is not desirable. Thru-Wall Installation C Thru-Wall Mount C Width H12 28.0 122 39 33.7 DGX H22 41.8 145 44.9 44.1 H32 63.1 160 48.7 53.1 ll dimensions are in inches. Thru-Wall Installation Option includes Weatherhood full downturn design with a generous intake area to minimize intake velocity and moisture entrainment. Thru-Wall Sleeve Filter Section Sleeve provides attachment interface between weatherhood and burner section. ccommodates walls up to 15 inches in depth. luminum mesh media filters outdoor air and strips fine mist from the air. drain pan weeps moisture out the front of the wall sleeve.

DGK, DG, DGX Dimensions for Packaged DX Cooling - DGX only D C Packaged DX Cooling C D E H12 156 33.8 25.5 70 39 DGX H22 212 45 32 87 45 H32 237 52 35.5 99 49 ll dimensions are in inches. E 98

Indirect Fired Gas Heat IGK-05-15 IG-10-20 -30 IGX-12-22 -32 *IGX with PDX-12-22 -32 est vailable Program 5 Days 10 Days 15 Days * est vailable based on size and capacity IGK, IG and IGX Indirect Gas-Fired The IGK, IG and IGX feature an 80% efficient indirect gas-fired furnace(s) which are ETL Listed. Performance Capacities is 15,000 cfm with up to 2 in. wg static pressure. Heating capacity ranges from 75,000 to 1,200,000 tu/hr. Optional Evaporative Cooling - IG and IGX The evaporative cooling section includes a galvanized steel housing with a louvered intake, 2-inch aluminum mesh filters and a stainless steel evaporative cooling module. The evaporative cooling media is Munters CELdek and has a depth of 12 inches for 90% cooling effectiveness. Optional Packaged Direct Expansion (PDX) - IGX only The packaged DX cooling option is designed to cool the kitchen makeup air to a 70-75ºF supply air condition to improve space comfort and enhance employee productivity at an economical first cost. The PDX option includes integral condenser fans, condenser and evaporator coils, thermal expansion valves, and compressors. Standard Construction IGK IG IGX Galvanized steel construction Power vented Control center with starter and disconnect Vibration isolation Factory-wired and tested Direct spark ignition system Insulated double-wall furnace section construction Options and ccessories IGK IG IGX irdscreen weatherhood luminum mesh filtered weatherhood Louvered weatherhood 100% outdoor air Recirculation Variable air volume (VV) Staged control Modulating control Remote panel Network interface Evaporative cooling Packaged DX cooling V-bank filter section Outdoor air damper Discharge air damper Duct liner insulation Double-wall construction Exhaust fan starter Dirty filter sensor Freeze protection Inlet air sensor Variable frequency drive (VFD) Service receptacle uxiliary contacts Gas pressure regulator Roof curb Duct adapter luminum or stainless steel heat exchanger 99 IGK, IG, IGX www.greenheck.com Commercial and Industrial Make-Up ir

IGK, IG, IGX Dimensions for IGK, IG 10 ft. min. * maximum 34 inches Stand-lone - rrangement D/HZ Combination Package - rrangement DC rrangement D/HZ Width H05 39.8 92.5 31.6 IGK H15 39.8 92.5 40.1 ll dimensions are in inches and include a weatherhood and 2-inch filter section. rrangement DC * Width H10 182 48 IG H20 183 52.5 H30 181 52.5 ll dimensions are in inches and include a weatherhood and 2-inch filter section. *ased on largest available CUE exhaust fan. 100 Dimensions for IGX * maximum 10 ft. min. Stand-lone - rrangement D/HZ Combination Package - rrangement DC rrangement D/HZ Width H12 127.1 39 44.6 IGX H22 155.1^ 45 44.6+ H32 172.3^ 48.7 52.2 ll dimensions are in inches and include weatherhood and 2-inch filter section. rrangement DC * Width H12 174 44.6 IGX H22 224.3^ 44.6+ H32 249.4^ 52.2 ll dimensions are in inches and include a weatherhood and 2-inch filter section. *ased on largest available CUE exhaust fan. ^ The dimension is for units with only one furnace. dd 33.1 inches for each additional furnace. + Furnace section width is 44.6 inches for furnaces sizes 350 MH or less. Width is 53.9 inches for furnaces greater than 350 MH.

Dimensions for Packaged DX Cooling - IGX only D C Packaged DX Cooling C D E H12 151.8 44.1 29.1 73.2 39 IGX H22 192.2 44.1 32.1 86.3 45 H32 216 52.2 35.3 100.1 48.7 ll dimensions are in inches. IGK, IG, IGX E 101

KSFD, KSF 102 est vailable Program 5 Days KSFD Direct Drive and KSF elt Drive - Untempered KSFD and KSF are designed to provide untempered make-up air for commercial and institutional kitchens. Installation may be stand-alone or on a combination curb with model CUE exhaust fan. Performance variety of blowers provide airflow capacities as high as 10,500 cfm with static pressures up to 2 in. wg. Standard rrangements KSFD and KSF have a compact design available with a horizontal discharge (arrangement HZ) or a downblast discharge (arrangement D). Installation may be as a stand-alone supply fan or a combination package with exhaust and supply fan on a common curb. Combination Packages The Greenheck combination package simplifies installation and reduces field labor costs. The pre-engineered design ensures that the supply fan, exhaust fan, curb and combination extension components interface properly. Equally important, Greenheck combination packages are specifically designed to comply with NFP 96. Kitchen Fan Control Center (KFCC) Prewired in compliance with the National Electrical Code, the KFCC simplifies field wiring, thereby reducing installation time and mistakes. The control center is a NEM Type 1 panel for mounting indoors. It is designed to interlock with the fire suppression system. Kitchen Supply Control Panel (KSCP) The KSCP offers safety and reliability for remote operation. The standard NEM Type 1 housing allows the panel to be mounted indoors. The panels can be provided with an optional kitchen hood light switch. Options and ccessories KSFD KSF Kitchen fan control center (KFCC) Kitchen supply control panel (KSCP) Roof curb Combo curb Duct adapter Damper Speed controller Extended weatherhood Horizontal or downblast discharge www.greenheck.com Kitchen Systems Make-Up ir

Dimensions for KSFD, KSF Stand-lone - Standard Weatherhood rrangement D Width H05 40.8 14.5 19.8 H08 40.8 14.5 36.8 H15 80.3 22.3 31.8 H25 99.3 29.5 40.0 KSFD, KSF rrangement D rrangement HZ rrangement HZ Width H05 31.5 18.5 19.8 H08 31.5 18.5 36.8 H15 71.0 25.3 31.8 H25 81.3 34.0 40.0 Stand-lone - Extended Weatherhood rrangement D Extended Weatherhood Option rrangement D Width H05 130.0 18.5 19.8 H08 124.8 18.5 36.8 H15 145.3 25.3 31.8 H25 152.5 34.0 40.0 103 3 ft. Vertical Separation Combination Package - Standard Weatherhood * rrangement D3 3 feet rrangement D3 * Width* H05 70.0 25.0 H08 82.3 36.8 H15 131.5 42.8 H25 159.8 50.0 * Maximum dimension. ased on largest available CUE exhaust fan. 10 ft. Horizontal Separation Combination Package - Extended Weatherhood * rrangement DC 10 ft. min. rrangement DC * Width* H05 159.3 25.0 H08 166.3 36.8 H15 196.5 42.8 H25 212.8 50.0 * Maximum dimensions. ased on largest available CUE exhaust fan. ll dimensions are in inches. Consult your representative for dimensional data when the evaporative cooling option is selected.