DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

Similar documents
SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

MERIT SERIES Downflow

ELITE SERIES Downflow - High Efficiency Blower Motor

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

MERIT SERIES Downflow

MERIT SERIES Downflow

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower

ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

13 GEP A L P - 1 A

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

8+* Bulletin No November 1997

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

RGE 13 A T - 1 A

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

MERIT SERIES Upflow / Horizontal

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

ML 1 80 UH 070 X E 36 B

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Upflow / Horizontal

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

CB X 32 mv

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

ELITE SERIES Upflow / Horizontal - Two-Stage Heat

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

G34M Bulletin #69/ August 2003

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling to 5 Tons GAS FURNACES ML180UHE

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

RG7D 1-Stage Heat Series

ML180UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ. Net Input to 34.8 kw Nominal Add-on Cooling to 17.

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler

FG7T (C and L Series)

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

TECHNICAL SPECIFICATIONS

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

TECHNICAL SPECIFICATIONS

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

G6RC Series TECHNICAL SPECIFICATIONS

ELITE Series Variable Capacity

GHR32Q/V SERIES UNITS

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL

Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2. System

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

G32V. Service Literature G32V SERIES UNITS

GAS FURNACES 90 PLUS COMMUNICATING MODULATING DOWNFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Corp L12 Revised G24M SERIES UNITS

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

PRPDF16 PRODUCT SPECIFICATIONS PRP DF P A SINGLE STAGE GAS VALVE TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Transcription:

PRODUCT SPECIFICATIONS GAS FURNACES SL80DFV DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Blower Bulletin No. 060 November 07 Supersedes August 05 MODEL NUMBER IDENTIFICATION SL 80 DF 070 X V 36 A AFUE - 80% Input - 66,000 to 0,000 Btuh Nominal Add-on - to 5 Tons Unit Type SL = Dave Lennox Signature Collection Stages = Two-Stage AFUE 80 = 80% Configuration DF = Downflow Nominal Gas Heat Input 070 = 66,000 Btuh 090 = 88,000 Btuh 0 = 0,000 Btuh Cabinet Width A = 4-/ in. B = 7-/ in. C = in. Nominal Add-On Capacity 36 = -3 tons 48 = 3-4 tons 60 = 3.5-5 tons Blower V = Variable Blower Motor Low NO x X = Units meet California Nitrogen Oxides Standard (40ng/J) Downflow indoor coils with the same letter designation will physically match the furnace supply air opening.

FEATURES CONTENTS H K Blower Data... 3 Dimensions - Accessories... Dimensions - Unit... 0 I Features... J Gas Heat Accessories... 9 Altitude Derate... 9 Installation Clearances... 9 L Model Number Identification... Optional Accessories... 8 Specifications... 8 B F G M C E D NOTE - SL80DFV FURNACES ARE NOT AVAILABLE IN CANADA! WARRANTY Duralok Aluminized Steel Heat Exchanger - Limited twenty year warranty in residential applications, ten years in non-residential applications. All other covered components - Limited ten year warranty in residential applications, one year in nonresidential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details. APPROVALS Units are certified by AHRI. Units tested and rated according to US DOE test procedures and FTC labeling regulations. Approved by the California Energy Commission and meets California Nitrogen Oxides Standard (NOx) limits of 40 ng/j. ISO 900 Registered Manufacturing Quality System. Blower data from unit tests conducted in Lennox Laboratory air test chamber. SL80DFV / Page APPLICATIONS Input capacities of 66,000, 88,000 and 0,000 Btuh. Energy efficiency (AFUE) of 80%. Compact cabinet for utility room, alcove or closet or attic installation. Lennox add-on indoor coils, high-efficiency air cleaners and humidifiers can easily be added to furnace. Shipped factory assembled with all controls installed and wired. Each unit factory test operated to ensure proper operation. NOTE - FURNACES CANNOT BE TWINNED! Zoning Applications The SL80DFV furnace can be used with the Lennox iharmony Zoning System with the icomfort Communicating Thermostat. The iharmony Zoning System provides direct feedback to the furnace, controlling both airflow and heat output to match the comfort requirements for up to four zones.

B C D E F FEATURES HEATING SYSTEM SilentComfort Technology Patent pending burner sound enclosure and extra cabinet insulation reduces operating sound levels. Lennox Duralok Heat Exchanger Assembly Heavy gauge aluminized steel heat exchanger. Crimped seam clamshell type design. Designed for normal expansion and contraction. Minimum resistance to air flow. Heat exchanger has been laboratory life cycle tested in excess of industry standards. Compact size of heat exchanger permits low overall design of furnace cabinet. Inshot Burners Aluminized steel inshot burners provide efficient, trouble-free operation. Burner venturi mixes air and gas in correct proportion for proper combustion. Burner assembly is removable from the unit as a single component for ease of service. SureLight Hot Surface Ignitor Tough, reliable, long-life, trouble-free performance. Silicon nitride ignitor. 0 volt. Cemented to steatite block for protection against current leakage. Ignition leads are constructed of nickel plated copper and are enclosed in high temperature Teflon insulation for dependable operation. Two-Stage Gas Control Valve 4 volt redundant combination two-stage gas control valve combines manual shut off switch (On-Off), automatic electric valve (dual) and gas pressure regulation into a compact combination control. Two- Combustion Air Inducer Heavy duty, permanent split capacitor (PSC) two-speed blower prepurges heat exchanger and safely vents flue products. Dual pressure switches (low fire/high fire) prove blower operation before allowing gas valve to open. Operates only during heating cycle. G H I Flame Rollout Switch Manual reset switch is factory installed on burner box. Switch provides protection from abnormal operating conditions. Limit Controls Automatic reset, primary and secondary limits are accurately located. Primary limit factory installed on vestibule panel on all units, secondary limit factory installed on blower housing. Optional Accessories Altitude Pressure Switch Kit Required on most units for proper unit operation at altitudes from 450 to 0,000 ft. Natural Gas to LPG/Propane Conversion Kit Required for field changeover from natural gas to LPG/ Propane. LPG/Propane to Natural Gas Conversion Kit Required for field changeover from LPG/Propane to natural gas. BLOWER Variable Direct Drive Blower Each blower assembly statically and dynamically balanced. Change in blower speed is easily accomplished by simple DIP switch change on the furnace control. See Blower Performance tables. Blower assembly easily removed for servicing. Variable Blower Motor Variable speed motor maintains specified air volume from 0 though 0.8 in. w.g. (heating) and 0 through.0 in. w.g. () static range. Variable speed operation is achieved by the use of an ECM (Electronically Commutated Motor) motor. Motor is controlled by furnace control. Motor is resiliently mounted. When furnaces are used with the iharmony Zoning System and the icomfort Communicating Thermostat, the blower motor operates from predetermined minimum - maximum air volumes to satisfy zone requirements. SL80DFV / Page 3

FEATURES J CONTROLS SureLight Control (icomfort Communicating) Advanced control communicates information about various operating parameters in the furnace to the optional icomfort Communicating Thermostat to constantly maintain the highest level of comfort and performance available. Auto Configuration - On startup the control automatically sends a description of the unit to the optional icomfort Communicating Thermostat to automatically configure the number of stages and features available. Connections for connecting a conventional heating/ cooling thermostat are also provided on the control. Control also features Innovative AirFlex technology allows custom blower settings based on the application. Thermostat Control - For optimal performance, the use of a high-quality, digital two-stage thermostat with adjustable settings for first stage/second stage, on/off differentials and adjustable stage timers is recommended. Furnace Input Staging Options Thermostat Type Input Staging Available icomfort Communicating Thermostat Two-Stage (Conventional) Single-Stage (Conventional) Two-Stage (65 and 00%) Safety Controls - Flame sensor utilizes flame rectification for safe and reliable operation. Should flame fail to ignite, control will initiate 4 reattempts at ignition before locking out unit operation for 60 minutes. Watchguard type circuit automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance calls for service. Display LED - Seven segment LED displays alphanumeric information related to diagnostics as well as system operation and status. Diagnostic codes are held in non-volatile memory, immune from power interruptions. Holds up to ten diagnostic codes in order of occurrence for recall on demand. Port on blower door allows for easy viewing. Select Thermostat used - Single-Stage or Two-Stage. Two selectable second stage recognition times (7 and minutes) are available on the control when the furnace is used with a single-stage thermostat. When used with a two-stage thermostat, furnace will only initiate second stage operation with a second stage thermostat demand. Heating s - A combination of DIP switch settings allow the following motor speed selection settings within the heating speed selected for fine tuning air volume: Factory default 6%, %, 8% or 4% increase 6%, % or 8% decrease See Blower Performance tables. s - A combination of DIP switch settings allow the following motor speed selection settings within the cooling speed selected for fine tuning air volume: Factory default 0% increase 0% decrease See Blower Performance tables. Blower Ramping ( Mode) - DIP switch settings allow one of four blower speed profiles during cooling operation. Profile A (factory setting) - Motor runs at 50% for 30 seconds, then at 8% for 7-/ minutes, then at 00% (if needed) until demand is satisfied. Once demand is met, motor runs at 50% for 30 seconds, then ramps down to stop. Profile B - Motor runs at 8% for 7-/ minutes and then at 00% (if needed) until demand is satisfied. Once demand is met,motor ramps down to stop. Profile C - Motor runs at 00% until demand is satisfied. Once demand is met, motor runs at 00% for 60 seconds, then ramps down to stop. Profile D - Motor runs at 00% until demand is satisfied. Once demand is met, motor ramps down to stop. Dehumidification (Active or Humiditrol Option) - A jumper on the control control must be clipped to enable active dehumidification and/or operation with a Humiditrol Whole-Home Dehumidification System. A humidity controlling thermostat or device is also required. During a call for cooling, air volume is automatically reduced, forcing humidity removal by the air conditioner or heat pump system. After the humidity has reached the desired set-point the cooling air volume returns to its designed rate. A dehumidification signal from the thermostat reduces the cooling cfm to 70% of the requested cooling cfm. SL80DFV / Page 4

FEATURES CONTROLS (continued) Dual-Fuel Operation - A jumper on the control must be clipped to enable operation with a single or two-stage heat pump. The indoor blower is started without delay when a call for heat is received. Two-Stage Compressor Operation - A jumper on the control must be clipped to enable operation with a two-stage compressor. The cooling blower speeds for first and second stage cooling will be dictated by the applicable DIP switch settings. Lennox System Operations Monitor Connection - Monitors outdoor unit operation (communicating mode). Blower On/Off Time (Heating) - Blower on time is fixed at 30 seconds, blower off time is adjustable from 60, 90, 0 and 80 seconds (factory setting - 90 seconds). Blower On/Off Time () - For air-conditioning applications, blower on time is seconds following thermostat demand for cooling. See Blower Ramping ( Mode) profiles for various blower off details. Controls evaporator humidity by controlling blower and compressor speed on two-stage outdoor units when used with the icomfort Communicating Thermostat or the ComfortSense 7500 Thermostat. Continuous Blower - Adjustable continuous blower speed is a percentage of the high cooling speed selection. There are four selectable options (via DIP switch settings) of 8%, 38% (default setting), 70% and 00%. Accessory Terminal - One accessory terminal furnished for additional power supply requirements for 0 volt (less than amp) powered air cleaners. One unpowered pair of contacts are provided for humidifier connections and may be connected to 4V or 0V. Control is factory installed in the unit control box. 4 Volt Transformer Furnished and factory installed in control box. 40VA transformer has circuit breaker wired in series. Field Wiring Make-Up Box Furnished for line voltage wiring. Factory installed internally on left side of furnace. Box may be installed internally or externally on either side of furnace. Optional Accessories icomfort S30 Ultra-Smart Thermostat (part of the icomfort Residential Communicating Control System) The icomfort S30 Thermostat recognizes and connects to all icomfort Communicating products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for icomfort Communicating products to simplify system setup. Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Service alerts and reminders sent via text message or e-mail. Dealer Dashboard features online real-time monitoring of installed icomfort Communicating systems. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen. Works with Amazon Alexa-enabled products. Easy to read 7 in. high definition color display (measured diagonally). Conventional outdoor units (not icomfort Communicating) can easily be added and controlled by the icomfort S30 Thermostat. Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 8-gauge standard thermostat wiring. Definition Color Display, Mag-Mount, Smart Hub Controller, wallplate (for retrofit installations) furnished for easy installation. See the icomfort S30 Thermostat Product Specifications bulletin in the Controls section for more information. SL80DFV / Page 5

FEATURES CONTROLS (continued) Optional Accessories icomfort Wi-Fi Thermostat (part of the icomfort Residential Communicating Control System) The icomfort Wi-Fi Thermostat recognizes and connects to all icomfort Communicating products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for icomfort Communicating products to simplify system setup. Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Service alerts and reminders sent via text message or e-mail. Dealer Dashboard features online real-time monitoring of installed icomfort Communicating systems. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen. Easy to read 7-inch color screen (measured diagonally). Conventional outdoor units (not icomfort Communicating) can easily be added and controlled by the icomfort Wi-Fi Thermostat. Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 8-gauge standard thermostat wiring. See the icomfort Wi-Fi Thermostat Product Specifications bulletin in the Controls section for more information. ComfortSense 7500 Touchscreen Thermostat Electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. 4 Heat/ Cool. Auto-changeover. Dual-fuel control with optional outdoor sensor. Controls dehumidification during cooling mode and humidification during heating mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen. Remote outdoor temperature sensor (optional) allows the thermostat to display outdoor temperature. Required in dual-fuel and Humiditrol applications. See the ComfortSense 7500 Product Specifications bulletin in the Controls section for more information. Remote Outdoor Temperature Sensor Used with the icomfort Communicating Thermostat and ComfortSense 7500 thermostat. When installed outdoors, sensor allows thermostat to display outdoor temperature. Sensor is auto-detected when connected to thermostat. NOTE - Sensor is required for Humiditrol applications. NOTE - The outdoor sensor is furnished as standard with icomfort Communicating outdoor units, optional for conventional units. Thermostat Thermostat (icomfort Communicating Thermostat or programmable/non-programmable) is not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book for selection. Optional Accessories Night Service Kit Contains most commonly used service parts: Furnace control Ignitor Flame sensor Gas valve Transformer SL80DFV / Page 6

FEATURES K L M CONTROLS (continued) Universal Service Kit - Switches Kit contains: Primary limits (for each model) Pressure switches (for each model) Flame rollout switches (for each model) Secondary limits (for each model) CABINET Low-profile, narrow width cabinet allows easy installation in downflow applications. Heavy-gauge, cold rolled steel construction. Pre-painted cabinet finish. Flanges provided on return air opening for ease of plenum connection. Fully insulated cabinet with foil faced insulation on sides and back of heating compartment and mat faced insulation in blower compartment. Sealed blower compartment. Inner blower compartment access panel seals blower compartment from air leakage. Cabinet door can be removed without any tools Complete service access. Safety interlock switch automatically shuts off power to unit when inner blower compartment access panel is removed. Gas piping and electrical inlets are provided in both sides of cabinet. FILTER (not furnished) Filter and provisions for external mounting must be field provided. Optional Accessories Downflow Filter Cabinet Filter cabinet mounts directly on top of furnace. A width cabinet includes one filter. B and C width cabinets include two filters. Filter rails are furnished. Front access for servicing. Cleanable filter(s) are furnished. Coil Match-Up All Lennox downflow indoor coils will physically match the furnace supply air opening with the same letter designation (A, B, C, D) as in the furnace model number. Low Leakage Cabinet All models have less than % air leakage and meet ANSI/ASHRAE Standard 93-00 Method of Test for Determining the Air Tightness of HVAC Equipment. Optional Accessories Downflow Combustible Flooring Base Required for heating only units installed on combustible flooring. Not required in add-on cooling applications. See Dimension drawing. SL80DFV / Page 7

SPECIFICATIONS Gas Heating Performance Low Model No. SL80DF070V36A SL80DF090V48B SL80DF090V60C SL80DF0V60C AFUE 80% 80% 80% 80% Input - Btuh 66,000 88,000 88,000 0,000 Output - Btuh 5,000 69,000 70,000 87,000 Temperature rise range - F 35-65 35-65 35-65 35-65 Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane 3.5 / 0.0 3.5 / 0.0 3.5 / 0.0 3.5 / 0.0 Input - Btuh 43,000 57,000 57,000 7,000 Output - Btuh 35,000 46,000 46,000 59,000 Temperature rise range - F 5-55 5-55 5-55 5-55 Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane.7 / 4.9.7 / 4.9.7 / 4.9.7 / 4.9 static - in. w.g. Heating 0.8 0.8 0.8 0.8 Connections in. Indoor Blower Electrical Data.0.0.0.0 Flue connection - in. round 4 4 4 4 Gas pipe size IPS / / / / Wheel nominal diameter x width - in. 0 x 8 x 9 x 0 x 0 Motor output - hp / Tons of add-on cooling - 3 3-4 3.5-5 3.5-5 Air Volume Range - cfm 589-54 830-996 899-73 88-0 Voltage 0 volts - 60 hertz - phase Blower motor full load amps 7.7.8.8.8 Maximum overcurrent protection 5 0 0 0 Shipping Data lbs. - package 30 53 64 73 NOTE - Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. OPTIONAL ACCESSORIES - ORDER SEPARATELY NOTE - FURNACES CANNOT BE TWINNED! CABINET ACCESSORIES A Width Models B Width Models C Width Models Downflow Combustible Flooring Base M59 M60 M6 CONTROLS icomfort S30 Thermostat U67 U67 U67 icomfort Wi-Fi Thermostat 0F8 0F8 0F8 Remote Outdoor Air Temperature Sensor (for dual fuel and Humiditrol ) X658 X658 X658 Discharge Air Temperature Sensor 88K38 88K38 88K38 ComfortSense 7500 Thermostat 3H4 3H4 3H4 3 Remote Outdoor Temperature Sensor (for dual fuel and Humiditrol) DOWNFLOW FILTER KITS X658 X658 X658 4 Downflow Filter Cabinet 5W06 5W07 5W08 NIGHT SERVICE KIT No. and Size of filter - in. () 0 x 0 x () 6 x 0 x () 6 x 0 x Night Service Kit 4C98 4C98 4C98 Universal Safety Kit - Switches 89W9 89W9 89W9 Remote Outdoor Temperature Sensor is used with conventional (non-icomfort Communicating) outdoor units (sensor is furnished with icomfort Communicating outdoor units). Allows the thermostat to display outdoor temperature. Required in dual-fuel and Humiditrol applications. Optional for service diagnostics. 3 Remote Outdoor Temperature Sensor for ComfortSense 7500 Thermostat must be connected directly to the thermostat, Do not connect it to the SureLight control. 4 Cleanable polyurethane, frame-type filter. SL80DFV / Page 8

GAS HEAT ACCESSORIES Input Altitude Pressure Switch Kit Natural Gas to LPG/Propane Kit LPG/Propane to Natural Gas Kit Natural Gas Altitude Orifice Kit LPG/Propane Altitude Orifice Kit 0-4500 ft. 450-7500 ft. 750-0,000 ft. 0-7500 ft. 0-7500 ft. 750-0,000 ft. 750-0,000 ft. 070 No Change No Change 73W36 K5 77W09 73W37 77W 090 No Change No Change 73W36 K5 77W09 73W37 77W 0 No Change No Change 73W35 K5 77W09 73W37 77W HIGH ALTITUDE DERATE NOTE - Units may be installed at altitudes up to 4500 ft. above sea level without any modifications. At altitudes above 4500 ft. units must be derated to match information in the shaded area shown below. NOTE - This is the only permissible derate for these units. Input Gas Manifold Pressure (Outlet) in. w.g. 0-4500 Feet 450-7500 Feet 750-0,000 ft. Natural Gas LPG/Propane Natural Gas LPG/Propane Natural Gas LPG/Propane Low Low Low 070 3.5.7 0 4.9 3.4.6 0 4.9 3.5.7 0 4.9 090 3.5.7 0 4.9 3.0.5 0 4.9 3.5.7 0 4.9 0 3.5.7 0 4.9 3..5 0 4.9 3.5.7 0 4.9 Natural Gas Alitude Orifice Kit required. Low Low Low INSTALLATION CLEARANCES - INCHES (MM) Vent Type Type B Type C Sides 0 inches (0 mm) 0 inches (0 mm) Rear 0 inches (0 mm) 0 inches (0 mm) Top inch (5 mm) inch (5 mm) Front -/4 inches (57 mm) -/4 inches (57 mm) Front (alcove) 4 inches (60 mm) 4 inches (60 mm) Front (service) 4 inches (60 mm) 4 inches (60 mm) Floor Combustible Combustible Flue inch (5 mm) 6 inches (5 mm) NOTE - Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ANSI-Z3.). NOTE - In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ ANSI-Z3.) or applicable provisions of local building codes. Left side requires 4 in. clearance if single wall vent is used on 4-/ in. A width cabinets, and in. clearance on 7-/ in. B width cabinets. Clearance for installation on combustible floor if optional Downflow Combustible Flooring Base is installed between furnace and combustible floor. Not required in add-on cooling applications if installed in accordance with local codes or National Fuel Gas Code ANSI-Z3.. SL80DFV / Page 9

DIMENSIONS - UNIT - INCHES (MM) 3-/8 (79) 9/6 (4) D FLUE OUTLET (Top) B RETURN AIR OPENING 9-7/6 (494) 9/6 (4) 9/6 (4) TOP VIEW A B 9/6 (4) -/ (38) Front Panel 7-3/4 (705) 9-7/6 (494) 9/6 (4) AIR FLOW 33 (838) 5-3/8 (37) Right -3/6 (56) Left ELECTRICAL INLET (Either Side) GAS PIPING INLET (Either Side) 6-5/8 (68) Right 7-/8 (8) Left 3/4 (9) C Supply Air 3/4 (9) 9-/4 (489) Supply Air 3/4 (9) FRONT VIEW SIDE VIEW Model No. A B C D in. mm in. mm in. mm in. mm SL80DF070V36A 4-/ 368 3-3/8 340 3 330 4-3/4 SL80DF090V48B 7-/ 446 6-3/8 46 6 406 6-/4 59 SL80DF090V60C SL80DF0V60C 533 9-7/8 504 9-/ 495 8 03 SL80DFV / Page 0

DIMENSIONS - ACCESSORIES - INCHES (MM) DOWNFLOW FILTER CABINET A WIDTH FURNACES (Single Filter) B AND C WIDTH FURNACES (Two Filters) 0-/ (5) 4-/ (368) 0-/ (5) 7-/ (445) B Box (533) C Box FILTER () (533) FILTERS () 7-/ (445) 54 (37) 50-/ (83 ) 33 (838) 33 (838) FILTER ACCESS DOOR FURNACE FURNACE FILTER ACCESS DOOR NOTE: Return Air Opening (W x D) A Box 3-/ x 9-5/8 (343 x 498) B Box 6-/ x 9-5/8 (49 x 498) C Box 0 x 9-5/8 (508 x 498) SL80DFV / Page

DIMENSIONS - ACCESSORIES - INCHES (MM) DOWNFLOW COMBUSTIBLE FLOORING BASE -/ (38) SUPPLY AIR OPENING DOWN FLOW FURNACE -/ (38) B 9-3/6 (503) -/ (38) 7-/4 (69) -3/6 (554) Front Of Furnace A -/ (38) TOP VIEW SIDE VIEW DOWNFLOW COMBUSTIBLE FLOORING BASE FLOOR OPENING Cabinet Width Catalog Number A B C in. mm in. mm in. mm A M59 6-9/6 4 3-9/6 344 5-3/4 400 B M60 9-9/6 497 6-9/6 4 8-3/4 476 C M6 3-/6 586 0-/6 50 -/4 565 (559) C DIMENSIONS - INCHES (MM) - FURNACE/COIL COMBINED DIMENSIONS Furnace Width 33 (838) Coil Height Overall Height Model Number Coil Width Furnace Width Coil Height Overall Height in. mm in. mm in. mm in. mm CR33-8A-F 7-/ 446 4-/ 368 4-/8 359 47-/8 97 CR33-4A-F 7-/ 446 4-/ 368 4-/8 359 47-/8 97 CR33-4B-F 7-/ 446 7-/ 446 4-/8 359 47-/8 97 CR33-30/36A-F 7-/ 446 4-/ 368 6-/8 40 49-/8 48 CR33-30/36B-F 7-/ 446 7-/ 446 6-/8 40 49-/8 48 CR33-30/36C-F 533 533 6-/8 40 49-/8 48 CR33-48B-F 533 7-/ 446 0 508 53 346 CR33-48C-F 533 533 0 508 53 346 CR33-50/60C-F 4-/ 6 533 3-5/8 600 56-5/8 76 Coil Width SL80DFV / Page

BLOWER DATA SL80DF070V36A BLOWER PERFORMANCE (less filter) 0 through 0.8 in. w.g. (Heating) and 0 through.0 in. w.g. () External Static Pressure Range Heating First Stage Heating - cfm HEATING Second Stage Heating - cfm +4% 065 70 +8% 00 5 +% 960 055 +6% 90 000 Factory Default 860 945 6% 805 885 % 755 830 8% 705 775 First Stage - cfm COOLING Second Stage - cfm Low Medium-Low Medium- Low Medium-Low Medium- + 667 756 87 00 05 0 4 47 Factory Default 68 683 778 94 9 04 5 304 537 69 69 8 800 900 04 69 and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific. Factory default setting. NOTES - The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 9% of the same second stage HEAT. First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 8%, 38%, 70% and 00% of the selected second stage cooling speed - minimum 50 cfm. Lennox iharmony Zoning System Applications - Minimum blower speed is 50 cfm. SL80DF070V36A BLOWER MOTOR WATTS (COOLING) + Setting Factory Default Setting First Stage Motor Watts @ Various External Static Pressures - in. wg. Second Stage 0 0. 0. 0.3 0.4 0.5 0.6 0.7 0.8 0 0. 0. 0.3 0.4 0.5 0.6 0.7 0.8 0.9.0 Low 44 6 74 90 03 9 33 48 66 9 44 66 89 3 4 67 78 98 33 Med-low 46 63 83 96 5 8 44 70 8 38 6 77 9 47 70 88 30 34 363 Med- 66 8 04 7 44 60 75 95 9 85 0 38 66 93 37 349 374 399 43 448 00 3 38 67 9 34 55 7 99 38 354 380 4 434 477 499 58 557 570 Low 34 53 65 78 90 05 8 9 44 89 34 53 78 94 08 9 47 63 73 Med-low 38 57 64 85 98 07 33 47 58 04 5 44 66 9 30 6 67 95 35 Med- 49 7 87 96 35 60 76 97 4 67 84 6 37 56 88 304 36 356 383 70 90 09 3 58 7 0 3 8 45 76 306 33 357 374 403 444 47 489 Low 3 44 56 67 80 9 00 69 86 05 4 40 54 76 96 09 0 4 Med-low 33 45 60 73 89 04 4 3 44 73 89 4 55 75 96 0 4 43 63 Med- 40 54 74 86 06 5 34 4 70 08 8 53 70 96 9 7 53 66 86 36 5 74 85 07 8 49 6 8 0 56 8 08 53 84 305 333 356 374 398 SL80DFV / Page 3

BLOWER DATA SL80DF090V48B BLOWER PERFORMANCE (less filter) 0 through 0.8 in. w.g. (Heating) and 0 through.0 in. w.g. () External Static Pressure Range Heating First Stage Heating - cfm HEATING Second Stage Heating - cfm +4% 360 500 +8% 85 45 +% 0 350 +6% 35 85 Factory Default 075 00 6% 030 0 % 960 050 8% 890 975 First Stage - cfm COOLING Second Stage - cfm Low Medium-Low Medium- Low Medium-Low Medium- + 740 905 040 0 085 330 545 730 Factory Default 690 80 950 0 990 00 400,595 60 745 855 005 895 075 70 460 and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific. Factory default setting. NOTES - The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 9% of the same second stage HEAT. First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 8%, 38%, 70% and 00% of the selected second stage cooling speed - minimum 380 cfm. Lennox iharmony Zoning System Applications - Minimum blower speed is 380 cfm. SL80DF090V48B BLOWER MOTOR WATTS (COOLING) + Setting Factory Default Setting First Stage Motor Watts @ Various External Static Pressures - in. wg. Second Stage 0 0. 0. 0.3 0.4 0.5 0.6 0.7 0.8 0 0. 0. 0.3 0.4 0.5 0.6 0.7 0.8 0.9.0 Low 33 59 77 98 4 66 9 4 97 9 50 88 7 47 67 30 33 365 394 Med-low 64 9 8 39 67 93 5 46 7 56 88 30 69 33 346 377 49 45 49 59 Med- 9 9 50 74 09 40 6 9 39 8 304 36 43 455 473 58 55 607 637 673 36 74 00 36 64 305 34 376 399 44 470 538 566 603 636 69 730 775 84 838 Low 3 50 63 84 04 4 50 68 94 74 03 6 55 83 0 43 64 90 36 349 Med-low 45 74 98 4 40 63 9 6 47 0 55 9 3 46 76 34 35 38 4 458 Med- 6 93 43 73 95 3 60 90 06 36 85 34 369 40 437 483 54 55 590 4 68 0 0 53 8 306 346 33 336 400 445 489 53 558 595 643 660 689 Low 7 38 56 7 88 5 3 50 70 5 78 06 9 55 78 07 9 59 89 3 Med-low 3 54 76 97 7 4 65 87 09 9 47 78 7 44 64 89 3 36 385 Med- 5 76 04 5 53 75 0 58 35 77 08 33 7 3 349 386 47 45 49 78 07 37 55 84 5 46 68 30 47 8 33 365 398 445 483 5 558 58 60 SL80DFV / Page 4

BLOWER DATA SL80DF090V60C BLOWER PERFORMANCE (less filter) 0 through 0.8 in. w.g. (Heating) and 0 through.0 in. w.g. () External Static Pressure Range Heating First Stage Heating - cfm HEATING Second Stage Heating - cfm +4% 540 695 +8% 465 65 +% 390 530 +6% 30 450 Factory Default 45 365 6% 70 85 % 095 05 8% 00 0 First Stage - cfm COOLING Second Stage - cfm Low Medium-Low Medium- Low Medium-Low Medium- + 5 50 400 590 585 770 000 75 Factory Default 00 35 85 445 40 60 845,050 900 005 55 80 305 395 645 875 and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific. Factory default setting. NOTES - The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 9% of the same second stage HEAT. First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 8%, 38%, 70% and 00% of the selected second stage cooling speed - minimum 450 cfm. Lennox iharmony Zoning System Applications - Minimum blower speed is 450 cfm. SL80DF090V60C BLOWER MOTOR WATTS (COOLING) + Setting Factory Default Setting First Stage Motor Watts @ Various External Static Pressures - in. wg. Second Stage 0 0. 0. 0.3 0.4 0.5 0.6 0.7 0.8 0 0. 0. 0.3 0.4 0.5 0.6 0.7 0.8 0.9.0 Low 8 09 35 54 90 5 43 69 9 97 9 69 34 35 403 44 465 503 54 57 Med-low 7 4 75 04 7 5 85 308 340 99 39 388 43 466 495 549 586 645 669 705 Med- 43 83 08 47 83 3 35 385 43 45 50 5 587 633 664 705 765 794 848 879 09 46 9 39 370 40 447 490 55 689 70 783 86 890 938 995 03 07 04 3 Low 63 9 4 39 6 86 6 4 70 44 83 7 48 86 307 354 386 4 459 498 Med-low 8 4 59 95 3 47 74 308 45 94 33 369 40 445 486 53 559 604 Med- 48 8 4 79 304 33 356 33 366 4 468 497 546 588 69 664 707 748 55 94 6 60 96 334 363 393 434 48 535 574 604 655 74 76 86 85 877 94 Low 53 76 0 39 66 84 09 38 7 49 80 03 35 69 94 37 349 387 4 Med-low 68 94 0 37 66 93 9 39 66 54 87 9 58 9 39 365 386 44 458 49 Med- 88 7 44 69 04 7 5 8 33 5 54 98 355 38 47 459 503 54 580 604 4 56 83 08 39 67 304 36 359 36 395 436 484 50 568 64 643 686 7 746 SL80DFV / Page 5

BLOWER DATA SL80DF0V60C BLOWER PERFORMANCE (less filter) 0 through 0.8 in. w.g. (Heating) and 0 through.0 in. w.g. () External Static Pressure Range Heating First Stage Heating - cfm HEATING Second Stage Heating - cfm +4% 645 80 +8% 565 70 +% 485 635 +6% 405 545 Factory Default 35 460 6% 45 370 % 70 85 8% 090 95 First Stage - cfm COOLING Second Stage - cfm Low Medium-Low Medium- Low Medium-Low Medium- + 055 30 365 55 500 755 95 0 Factory Default 975 5 50 400 360 585 770 960 895 005 30 45 5 405 595 760 and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific. Factory default setting. NOTES - The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 9% of the same second stage HEAT. First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 8%, 38%, 70% and 00% of the selected second stage cooling speed - minimum 450 cfm. Lennox iharmony Zoning System Applications - Minimum blower speed is 450 cfm. SL80DF0V60C BLOWER MOTOR WATTS (COOLING) + Setting Factory Default Setting First Stage Motor Watts @ Various External Static Pressures - in. wg. Second Stage 0 0. 0. 0.3 0.4 0.5 0.6 0.7 0.8 0 0. 0. 0.3 0.4 0.5 0.6 0.7 0.8 0.9.0 Low 78 0 8 44 7 00 8 44 64 7 96 43 84 3 360 39 48 45 494 58 Med-low 08 35 6 9 3 4 69 95 34 68 94 35 376 44 466 505 554 58 604 645 Med- 46 80 03 38 7 305 334 358 396 373 44 459 504 59 575 64 680 7 747 80 8 9 54 9 37 365 40 436 479 50 557 596 660 75 763 85 869 9 96 993 Low 6 87 08 5 48 73 96 39 35 65 94 3 67 305 30 346 38 4 457 Med-low 87 5 35 58 89 8 36 64 85 95 6 70 3 347 377 4 455 494 530 56 Med- 4 40 73 0 4 50 83 3 339 90 335 358 40 450 497 58 565 6 640 677 48 86 07 46 8 307 354 375 40 395 438 484 55 559 608 659 7 745 776 86 Low 47 67 94 08 8 40 7 93 06 34 6 9 4 38 59 95 3 349 379 Med-low 67 9 4 34 5 80 06 6 47 47 8 0 45 80 3 347 376 404 445 476 Med- 94 6 4 67 98 0 4 59 88 07 36 84 30 356 39 4 473 494 535 573 8 46 76 0 48 85 33 337 80 35 356 398 444 478 50 559 607 67 669 SL80DFV / Page 6

REVISIONS Sections Document Description of Change Revised icomfort -enabled to icomfort Communicating. icomfort -enabled no longer means communicating with the advent of the E30 and M30 thermostats. Visit us at www.lennox.com For the latest technical information, www.lennoxpros.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 07 Lennox Industries, Inc.