OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

Similar documents
OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

Owner s Manual PRINTED IN CANADA 05/2009

Quick Start Guide. For product manuals and further installation / operation procedures visit

This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use.

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

INSTALLATION MANUAL. G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida

OWNER S Manual PRINTED IN CANADA 10/2009

G&F Manufacturing Swimming Pool Heat Pump Install & Operations Manual

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061

Owner s Manual for Swimming Pool Heat Pump

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

Heat Pumps. English. Models: M1, M2, M3, M4, M5. User Manual

Surna 25-Ton Chiller Operating & Maintenance Manual

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series

Swimming Pool Heat pump Instruction manual Harmo PAC series (Type ZVWX1017, ZVWX1023, ZVWX1033, ZVWX1042, ZVWX1052, ZVWX1057, ZVWX1062)

G&F Manufacturing Service Manual Version 2.0 April 2010

This manual should be maintained in legible condition and kept adjacent to the heat pump pool heater or in a safe place for future use.

SWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual

OPERATING INSTRUCTIONS

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Owner s Manual & Installation Guide. Model 525S Model 525TI Model 650TI Model 650SC Model 700TI

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Condensing Unit Installation and Operating Instructions

AquaCal Operation Manual

This manual should be maintained in legible condition and kept adjacent to the heat pump pool heater or in a safe place for future use.

SWIMMING POOL & SPA HEAT PUMPS INSTALLATION MANUAL

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

OWNER and INSTALLATION MANUAL

Harmo Powerpack Horizontal Units Installation & instruction manual

OPERATING & MAINTENANCE MANUAL HORIZONTAL WATER SOURCE HEAT PUMP. World class comfort.

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

AquaCal Operation Manual

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

T-Series Air Conditioner T15 Model

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

Q&A 2016 Practical Guide

CHAMPION PUMP OWNER S MANUAL

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

AquaCal Operation Manual

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Installation, Operation, and Maintenance Information

VIGOH55 HEAT PUMP OWNER S!MANUAL! 4438!Muhlhauser!Road!! Suite!600! Hamilton,!OH!45011! 877F278F

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

Series 9350HC, 9353HC, 10353HC, 10354HC and 10355HC

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

40KMC KMQ

Hayward/Summit Heat Pump Troubleshooting Guide Hayward Industries

Swedish design and manufacture since 1967

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

POOL & SPA HEAT PUMP OWNER S MANUAL

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

AquaCal Operation Manual

Horizontal/Side Discharge Condensing Units

Drop-In Refrigeration System

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

INSTALLATION INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE

T-Series Air Conditioner T20 Model

AquaCal Installation Manual

SunBlazer Installation Manual

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

Instruction Manual Item No.: V~, 60Hz

INSTALLATION AND USER MANUAL

THRU-THE-WALL AIR CONDITIONER

ELECTRONIC CONTROL AIR CONDITIONER

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

Bulletin (Jan 2011) And User s Guide

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

AIR CONDITIONER ELECTRONIC CONTROL

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

AQUA LOGIC S MULTI-TEMP Water-Cooled Marine Duty Series chiller

Next Generation Corona Discharge Installation & Operation Manual

AquaCal Installation Manual

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

SLIDER CASEMENT AIR CONDITIONER

Condensing Unit Installation and Operating Instructions

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Instruction Manual Item No.: V~, 60Hz

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

IW-25-2 Dehumidifier Installation & Operations. Manual

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

T-Series Air Conditioner T53 Model

Transcription:

OWNER S MANUAL Vintage Classic HEAT COOL models Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support 888-475-7443 Manufacturing High Quality, High Efficiency Heat Pump Pool Heaters TABLE OF CONTENTS SAFETY CONSIDERATIONS 2 INSPECTION 2 GENERAL INFORMATION 2 INSTALLATION 2 WATER FLOW & CONNECTIONS 2-3 ELECTRICAL CONNECTIONS 4 MODES OF OPERATION 5 WIRING DIAGRAMS 6 ELECTRONIC CONTROL PANEL 7-8 CHEMICAL USE 9 START-UP 10-11 MAINTENANCE 12 TROUBLESHOOTING CHECKLIST 12-13 CALLING FOR SERVICE 14 WARRANTY 15 WARRANTY REGISTRATION 16 MODEL: HEAT & COOL INSTALLATION, OPERATION, MAINTENANCE & SERVICE 1

SAFETY CONSIDERATIONS Qualified personnel should perform installation, maintenance and service. Make sure all field wiring conforms to the heater specifications and all national and local codes. Disconnect all power sources before performing any maintenance or service to the heater. INSPECTION Immediately upon receipt, inspect cartons and their contents for damage due to transit. Damage, if found, should be noted on delivery papers and a claim filed with the carrier. Also, check unit data plate to make sure you have the proper model, before installing. GENERAL INFORMATION The information in this manual was prepared to assist in the proper installation, operation, maintenance and service of your new heat pump pool heater. Please read the entire manual and follow all instructions. Improper installation and use can result in damage to the heater, unsatisfactory operation, and may void the warranty. Retain this manual for quick reference. INSTALLATION When selecting a location consider the following: Heater must be located outdoors. Minimum of 24 of clearance on access / service side of heater. Minimum of 18 of clearance on all three air intake sides of heater. Minimum of 48 of clearance for air discharge (top of unit). The heater should sit on a solid level surface sufficient above grade to prevent water from entering it, and allowing condensate to drain from base. The length of water piping and electric should be kept to a minimum to avoid capacity loss and decreased efficiency. WATER FLOW & CONNECTIONS Water connections are made at the rear of the heater. Both water in and out are labeled at the water connections. LEFT REAR = WATER IN and RIGHT REAR = WATER OUT. 2 unions are supplied and are made to accept 2 rigid PVC pipe. NOTE: unions can be used for quick drainage of your heater and winterizing. Heater must be piped downstream from filter in the pool return line. Inline chlorinators must be piped downstream from heater. A check valve should be installed between the heater and chlorinator to prevent drain back of the chlorine when the pump is off. A chemical trap may also be piped at least six (6) inches above the height of the chlorinator. 2

When all the plumbing connections are complete, and ample drying time is allowed, run the filter pump and check the entire system for water leaks. Make sure filter is clean and there are no obstructions in the filtering system. Proper water flow is essential to the performance of your heater. The minimum flow rate is 20 GPM. TYPICAL WATER FLOW CONNECTIONS 3

ELECTRICAL CONNECTIONS Field connections must comply with national and local codes. The work must be done by a qualified electrician. Heater must be permanently grounded and bonded. Bonding will drastically reduce the chances of electrolysis, Electrical Corrosion. Use copper conductors only. Disconnect all power sources before performing any work on unit. Standard Power Supply: 208/230-60 1 See unit data plate for specific ampacity. Wiring Main Power Supply 1. Remove the screws from lower left and right side of front cover (service panel). 2. Remove the screws on left side of hinged electrical enclosure. 3. Route weather tight flexible conduit through opening at base of unit. Connect conduit to the bottom of the electrical enclosure using a weather tight fitting. A knockout is provided to accept the weather tight fitting. Mounting conduit directly to the electrical enclosure will ensure a moisture tight seal, extending the life of the heater. 4. Attach grounding conductor to the ground lug provided inside the electrical enclosure (labeled). 5. Install L1 and L2 input conductors to the line side of the main contactor. (See wiring diagrams.) 6. Connect bond wire (at least #8 solid copper wire) from bond lug on right side of coil header panel to pool pump bonding terminal or other suitable location. Install Heat/Cool Switch The switch to change from Heating to Cooling is removed from the electrical enclosure after testing at the factory to prevent damage during shipping. It must be reinstalled in the field at time of installation. REMOTE THERMOSTATS AND CONTROLLERS: see page 6, SET UP MODE. 4

WIRING DIAGRAM FIELD WIRING DIAGRAM NOTES 1. USE COPPER CONDUCTORS ONLY. 2. CONNECT FIELD WIRING IN GROUNDED WEATHER TIGHT CONDUIT, PER RATING PLATE. 3. CONNECT BOND WIRE TO POOL STEEL USING #8 SOLID COPPER WIRE OR LARGER. 4. ALL WIRING MUST CONFORM TO NATIONAL (N.E.C.) AND LOCAL ELECTICAL CODES. 5

SET UP MODE WARNING: THE SET UP MODE IS DESIGNED AS AN ADVANCED USER S AND INSTALLATION MENU; THE DIRECTIONS IN THIS SECTION MUST BE FOLLOWED CAREFULLY. AN ERROR IN PROGRAMMING MAY EFFECT THE OPERATION AND PERFORMANCE OF THE HEATER AND MAY RESULT IN UNNECESSARY OR ERRONEOUS SERVICE CALLS. Enter the set up mode by pressing both the UP and DOWN buttons for 5 seconds. Once in the set up mode, you can advance from one screen to another by pressing the SELECT button. The setting within the screen can be adjusted by pressing the UP or DOWN button. To exit the set up mode press both UP and DOWN buttons at the same time for 5 seconds. The following are screens in the SET UP mode: POOL/SPA REMOTE With this setting you can enable or disable the remote capability of switching from pool to spa mode automatically. The use of an external water pressure switch in the spa piping is necessary. A two wire circuit must be connected from the water pressure switch to the terminals marked REMOTE POOL/SPA on the electronic control board. When enabled and the external water pressure switch is closed the control will operate in spa mode, when the switch is opened the heater will operate in pool mode. The default setting is DISABLED. REMOTE THERMOSTAT With this setting you may enable or disable the remote capability. In the POOL MODE, you will have the capability to call for heating or cooling depending in which mode the Heat/Cool switch on the heat pump is set in. In SPA MODE you will have the capability to turn the heating on and off. Enabling the remote thermostat and closing the external switch will call for heating or cooling regardless of the temperature set point. In the case of a remote thermostat where the temperature will be regulated externally, set the SPA temperature to 104 degrees F (40 C) and leave the heat pump controller in the SPA MODE. The heat pump will run only when the remote calls for heating or cooling. The default setting is DISABLED. TIME DELAY With this setting you can adjust the time delay for compressor turn on. When set to 0 the control is in test mode. Test mode will exit automatically after 10 minutes or if power is turned off. Note: control will flash Delay when ever the time delay applies. The default setting is 5. SPA TIMER With this setting you can adjust the time you spend in the spa in which heat is provided. The spa timer can be set Continuous, Off, or for a time interval between 15 minutes and 20 hours in increments of 15 minutes. Default setting is CONTINUOUS. 6

TEMPERATURE SCALE With this setting you have the choice of the displayed temperature in Fahrenheit or Celsius. Default setting is F. DEFROST SELECTION With this setting you can select whether defrosting shall be done in with air flow or by energizing the reversing valve. By pressing either up or down you can toggle between AIR DEFROSTING or REVERSE CYCLE. Default setting is AIR DEFROSTING.. WATER SENSOR CALIBRATION With this setting you can calibrate the water temperature reading. The calibration range is +/- 10 degrees F or +/- 5 degrees Celsius. Default setting is 0. EVAPORATOR SENSOR CALIBRATION With this setting you can calibrate the evaporator temperature reading. The calibration range is+/- 10 degrees Fahrenheit or +/- 5 degrees Celsius. Default setting is 0. ELECTRONIC CONTROL PANEL LCD DISPLAY Displays the actual pool/spa temperature. In select mode displays other parameters. POOL HEAT 85 SELECT/SERVICE KEY Used to select mode of operation and enter service mode. INCREASE KEY DECREASE KEY MODE SELECTION NORMAL MODE When power is applied, the heater will turn on in the last mode in which it was used. User adjustable temperature range will be 50 to 95 degrees in Pool mode and 50 to 104 degrees in Spa mode. 7

When user lowers the set point below 50 degrees F in one of these modes, that mode will be turned OFF. NOTE: AN EXTERNAL SWITCH LOCATED ON FRONT OF THE CONTROL PANEL IS USED TO TOGGLE BETWEEN HEAT AND COOL. POOL MODE HEATING When operating in pool heat mode display will show POOL HEAT on the top line and the actual pool water temperature on the bottom line. FOR EXAMPLE: POOL HEAT 95º To adjust the temperature set point user will press either the Up or DOWN button once. The Display will show POOL TEMPERATURE on the top line and the current set point temperature on the bottom line for 5 seconds (for example: SETPOINT 95F). Adjust the set point by pressing either UP or DOWN until the new set point is reached for heating. The display will revert to POOL HEAT after 5 seconds of inactivity and the new set point will be stored in memory. When the water temperature falls 1 degree below the set point, the control will energize heating mode (compressor) after the time delay has expired. The time delay is necessary to ensure proper water pressure within the pool filter system and to avoid short-cycling the compressor. During heating once the water temperature reaches the set point, compressor is turned off. POOL MODE COOLING When operating in pool cool mode the display will show POOL COOL on the top line and the actual pool water temperature on the second line. FOR EXAMPLE: POOL COOL 70º An external switched located on the front of the control panel is used to toggle between heat and cool. Control will switch to cool mode by closing the switch in which case display will show POOL COOL on the top line and the current temperature on the bottom line. To adjust the temperature point user will press either the UP or DOWN button once. The display will show POOL TEMPERATURE on the top line and the current set point temperature on the bottom line for 5 seconds. Adjust the set point by pressing either UP or DOWN until the new set point is reached for cooling. The display will revert to POOL COOL after 5 seconds of inactivity and the new set point will be stored in memory. When the temperature becomes 1 degree greater than the set point, the control will energize cooling mode (compressor and reversing valve)) after the time delay has expired. During cooling once the water temperature reaches the set point, the compressor is turned off. 8

SPA MODE HEATING When operating in spa mode display will show SPA HEAT on the top line and the actual spa water temperature on the second line. EXAMPLE: SPA 104º To operate in SPA mode user will press the POOL/SPA button (center hand button) once. After pressing the POOL/Spa button, the display will show SPA TEMPERATURE on the top line and the current temperature set point on the bottom line for 5 seconds. Adjust the set point by pressing either UP or DOWN until the new set point is reached for spa heating. The display will revert back to SPA HEAT and the current spa temperature after 5 seconds of inactivity and the new set point will be stored. When the spa water temperature falls 1º F below the set point, the control will energize spa heating mode (compressor) after the time delay has expired. During heating once the water temperature reaches the set point, the compressor turns off. CHEMICAL USE Water quality must be checked regularly and maintained within recommended limits at all times. Failure to maintain the proper water quality will greatly reduce the life of your heater. Never add chemicals directly into skimmer. Automatic chlorinators must be piped downstream from the heater. A check valve must be installed between the chlorinator and heater to prevent raw chlorine from draining back into the heater. A chemical trap may be piped at least six (6) inches above the chlorinator. See piping diagram B. Always maintain the following water quality requirements: PH LEVEL 7.4 to 7.8 CHLORINE CONCENTRATION 1 to 5 PPM TOTAL ALKYALINITY 100 to 200 PPM CALCIUM HARDNESS 100 to 300 PPM 9

START-UP Before proceeding with this section make certain all plumbing connections are airtight and leak free. Flow rates should not exceed 70 GPM maximum. Use of an external bypass is necessary at 70 GPM and above. Minimum flow rate is 20 GPM. Turn filter pump time clock to the ON position and set filter pump hours. For initial heating, the pool heater and filter pump may need to run continuously until your desired temperature is reached. After initial heating is achieved, the heater will run only to maintain your desired temperature. Turn power supply to heater ON. The control panel will light up and display either POOL HEAT OFF or the actual pool water temperature. Select POOL TEPERATURE SETPOINT or SPA TEMPERATURE SETPOINT and set your desired water temperature by scrolling either up or down. If your programmed water temperature is above the actual water temperature and the 5 minute time delay is satisfied the compressor will start. NOTE: Each time the compressor turns off; it is protected by a 5 minute anti-cycling delay. INITIAL HEATING Initial heating may require you to run your heater and filter pump continuously for at least 24 hours, or more, depending on the following factors: Temperature difference between actual water temperature and desired water temperature. Size of pool. Ambient air temperature, the cooler the air temperature the longer the heating time. Heat loss (evaporative, convective, radiative and conductive). A pool cover / solar blanket may reduce initial heating time by up to 50 percent. Reducing Heat Loss - Pool Cover / Solar Blanket We highly recommend the use of a pool cover / solar blanket. Covering your pool is the single most cost effective means of reducing heat costs from 50 to 70 percent. Heating a pool without a cover is like heating a house without a roof. They also reduce the amount of maintenance costs. By reducing evaporation, covers reduce the quantity of chemicals needed. 10

Because evaporation accounts for about 70 percent of pool heat loss, the beneficial effect of using a pool cover /solar blanket can be dramatic. Wind Speed Reduction Reducing wind velocity at the water surface reduces convective and evaporative losses. Fences, trees, hills, or tall hedges close to the pool perimeter are effective windbreaks. Locate these obstructions to take maximum advantage of their effectiveness as windbreaks, without shading the pool surface from the sun. Defrost Cycle The heat pump pool heater has automatic defrost. When the outdoor temperature drops below 40 F, frost may start to form on the evaporator coil. Frost buildup will be heaviest on humid days when the temperature is between 35-40. During the defrost cycle, the display will show DEFROSTING to indicate that the unit is defrosting. During this time the fan is running and the compressor is inactive. Internal Protection Analyzers The heater is equipped with internal devices to monitor and protect the integrity of the unit. Should an abnormal condition occur, these devices will interrupt the operation of the unit and may display the appropriate code on the control panel. LOW WATER FLOW: Indicated by FLO, HIGH REFRIGERANT PRESSURE, or 3 HPS STRIKES LOCKOUT on the control panel. The heater is designed to run efficiently above twenty (20) GPM. If there is insufficient water flow, the unit will shut down, protecting the compressor. The usual causes for these conditions are a dirty pool water filter, a restriction in the return line (i.e. skimmer), or improper valve positioning. NO WATER FLOW: Indicated by LOW FLOW on the control panel. When the filter pump is off, or if the water flow to the heater is interrupted during the heating mode, the internal water pressure switch will shut down the unit. When normal water flow resumes, the heater will automatically restart itself. Other analyzer codes include: FL3, LP3, LP, dpo, PO, dpc, Pc, PLE, CSE and SPi. The TROUBLESHOOTING CHECKLIST on page 11 goes into detail on these analyzers codes. 11

MAINTENANCE WARNING: DISCONNECT ELECTRICAL POWER TO UNIT BEFORE STARTING ANY MAINTENANCE TO PREVENT SERIOUS INJURY FROM SHOCK. Protecting your Heater Keep your pool filter system clean and free of restrictions to ensure proper water flow. Check water chemistry regularly. Misuse of chemicals will cause permanent damage to your heater and other pool equipment. Manufacturers can void warranties for damage as a result of poor water quality. Free airflow is essential. Keep the evaporator coil clean and free of weeds, leaves, glass clippings, dirt and other debris that will decrease the airflow. Keep fences and shrubs away from air inlets (sides and back of heater). Frequent rinsing of the evaporator with fresh water will remove build up from its surface. Always spray the coil gently with a regular garden hose being careful not to bend aluminum fins. Regular cleaning of the cabinet will improve its appearance and extend the life of the finish. Winterizing When the heater is exposed to freezing temperatures, it is essential that all water within the unit be properly drained. When water freezes, it expands, damaging piping. Turn thermostat settings to OFF. Turn filter pump to OFF. Turn power to unit OFF (i.e. pull disconnect or turn circuit breaker OFF). Disconnect water inlet and outlet unions at the back of the unit. Be careful not to lose rubber o-rings. Flush the heater piping out with fresh water to remove any residual chemicals. Use low-pressure air or vacuum to remove water that has accumulated inside the piping of the heater. TROUBLESHOOTING CHECKLIST Check to see that the electrical power is on. Reset breakers, or replace fuses if necessary. Check to be sure the electric control panel is set properly. The desired temperature must be set above the actual pool or spa temperature for the heater to run. Check to make sure the evaporator coil has enough clearance and that there are no restrictions to its airflow. Certain ambient air conditions may cause the heater to go into defrost mode, displayed on the control panel as AIR DEFROSTING or REVERSE CYCLE. 12

NOTE: IT IS NORMAL FOR WATER TO DRIP FROM THE DRAINHOLES AT THE BASE OF THE HEATER. THE UNIT PRODUCES CONDENSATE WHEN IT OPERATES. Analyzer Codes FAILURE LOCK-OUT: This feature is for the protection of the heater. If the same failure occurs three (3) times within an hour, the control will not allow the unit to restart, and shall display the appropriate code (i.e., 3 LPS STRIKES LOCKOUT, or 3 HPS STRIKES LOCKOUT ). The reset to normal conditions can be accomplished by pressing any button on the control touch pad. LOW FLOW (Little or No Water Flow) The pump is not running. The filter is dirty or clogged. Shortage of water to pump - air leak. Undersized pump. Valves not in correct position. Filter in backwash mode. Water pressure switch needs adjustment, or is defective. HIGH REFRIGERANT PRESSURE (Compressor High Pressure) Low water flow to heater. Defective high-pressure switch. LOW REFRIGERANT PRESSURE (Compressor Low Pressure) Evaporator coil dirty. Fan motor not running. Low refrigerant pressure. Defective low-pressure switch. EVAPORATOR SENSOR MALFUNCTION Evaporator temperature sensor connection opened or shorted. Check for cut or loose sensor wiring or defective sensor. WATER SENSOR MALFUNCTION Water temperature sensor connection open or shorted. Check for a short in sensor wiring or defective sensor. DEFROSTING or REVERSE CYCLE Heat pump in defrost cycle. 13

CALLING FOR SERVICE Please eliminate any water flow problems before calling for service. If you are unable to contact the installing agent, please go to www.aquacomfort.com/service-and-support/ to contact AQUA COMFORT TECHNOLOGIES LLC. A factory representative will assist you or your serviceman over the phone. SERVICE PERFORMED WITHIN THE WARRANTY PERIOD MUST BE APPROVED BY AQUA COMFORT TECHNOLOGIES, LLC. PRIOR TO SERVICE BEING PERFORMED AND ONLY BY A AQUA COMFORT TECHNOLOGIES AUTHORIZED TECHNICIAN. SEE WARRANTY FOR DETAILS. Please have the following ready before calling: MODEL #: SERIAL #: DATE OF INSTALLATION: NAME OF OWNER: ADDRESS: CONTACT #: NATURE OF PROBLEM: 14